Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.295
Filtrar
1.
Jt Dis Relat Surg ; 35(2): 340-346, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727113

RESUMO

OBJECTIVES: The aim of this study was to investigate the effects of adding hexagonal boron nitride at four different concentrations to polymethylmethacrylate (PMMA) bone cement, which is commonly used in orthopedic surgeries, on the mechanical properties and microarchitecture of the bone cement. MATERIALS AND METHODS: The study included an unaltered control group and groups containing four different concentrations (40 g of bone cement with 0.5 g, 1 g, 1.5 g, 2 g) of hexagonal boron nitride. The samples used for mechanical tests were prepared at 20±2ºC in operating room conditions, using molds in accordance with the test standards. As a result of the tests, the pressure values at which the samples deformed were determined from the load-deformation graphs, and the megapascal (MPa) values at which the samples exhibited strength were calculated. RESULTS: The samples with 0.5 g boron added to the bone cement had significantly increased mechanical strength, particularly in the compression test. In the group where 2 g boron was added, it was noted that, compared to the other groups, the strength pressure decreased and the porosity increased. The porosity did not change particularly in the group where 0.5 g boron was added. CONCLUSION: Our study results demonstrate that adding hexagonal boron nitride (HBN) to bone cement at a low concentration (0.5 g / 40 g PPMA) significantly increases the mechanical strength in terms of MPa (compression forces) without adversely affecting porosity. However, the incorporation of HBN at higher concentrations increases porosity, thereby compromising the biomechanical properties of the bone cement, as evidenced by the negative impact on compression and four-point bending tests. Boron-based products have gained increased utilization in the medical field, and HBN is emerging as a promising chemical compound, steadily growing in significance.


Assuntos
Cimentos Ósseos , Compostos de Boro , Força Compressiva , Teste de Materiais , Polimetil Metacrilato , Compostos de Boro/química , Compostos de Boro/farmacologia , Polimetil Metacrilato/química , Cimentos Ósseos/química , Teste de Materiais/métodos , Porosidade , Estresse Mecânico
2.
Biomed Phys Eng Express ; 10(4)2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38744248

RESUMO

Evaluating neutron output is important to ensure proper dose delivery for patients in boron neutron capture therapy (BNCT). It requires efficient quality assurance (QA) and quality control (QC) while maintaining measurement accuracy. This study investigated the optimal measurement conditions for QA/QC of activation measurements using a high-purity germanium (HP-Ge) detector in an accelerator-based boron neutron capture therapy (AB-BNCT) system employing a lithium target. The QA/QC uncertainty of the activation measurement was evaluated based on counts, reproducibility, and standard radiation source uncertainties. Measurements in a polymethyl methacrylate (PMMA) cylindrical phantom using aluminum-manganese (Al-Mn) foils and aluminum-gold (Al-Au) foils and measurements in a water phantom using gold wire with and without cadmium cover were performed to determine the optimal measurement conditions. The QA/QC uncertainties of the activation measurements were 4.5% for Au and 4.6% for Mn. The optimum irradiation proton charge and measurement time were determined to be 36 C and 900 s for measurements in a PMMA cylindrical phantom, 7.0 C and 900 s for gold wire measurements in a water phantom, and 54 C and 900 s at 0-2.2 cm depth and 3,600 s at deeper depths for gold wire measurements with cadmium cover. Our results serve as a reference for determining measurement conditions when performing QA/QC of activation measurements using HP-Ge detectors at an AB-BNCT employing a lithium target.


Assuntos
Terapia por Captura de Nêutron de Boro , Lítio , Aceleradores de Partículas , Imagens de Fantasmas , Controle de Qualidade , Lítio/química , Terapia por Captura de Nêutron de Boro/métodos , Humanos , Aceleradores de Partículas/instrumentação , Reprodutibilidade dos Testes , Polimetil Metacrilato/química , Nêutrons , Ouro/química , Alumínio/química , Água/química , Radiometria/métodos , Radiometria/instrumentação , Dosagem Radioterapêutica
3.
Int J Mol Sci ; 25(9)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38732100

RESUMO

The use of temporary resin for provisional restorations is a fundamental step to maintain the position of prepared teeth, to protect the pulpal vitality and the periodontal health as well as the occlusion. The present study aimed at evaluating the biological effects of two resins used in dentistry for temporary restorations, Coldpac (Yates Motloid) and ProTemp 4™ (3M ESPE ™), and their eluates, in an in vitro model of human gingival fibroblasts (hGFs). The activation of the inflammatory pathway NFκB p65/NLRP3/IL-1ß induced by the self-curing resin disks was evaluated by real-time PCR, Western blotting and immunofluorescence analysis. The hGFs adhesion on resin disks was investigated by means of inverted light microscopy and scanning electron microscopy (SEM). Our results suggest that hGF cells cultured in adhesion and with eluate derived from ProTemp 4™ (3M ESPE ™) resin evidenced a downregulation in the expression of the inflammatory mediators such as NFκB p65, NLRP3 and IL-1ß compared to the cells cultured with Coldpac (Yates Motloid) after 24 h and 1 week of culture. Furthermore, the cells cultured with ProTemp 4™ (3M ESPE ™) after 24 h and 1 week of culture reported a higher cell viability compared to the cells cultured with Coldpac (Yates Motloid), established by MTS cell analysis. Similar results were obtained when hGFs were placed in culture with the eluate derived from ProTemp 4™ (3M ESPE ™) resin which showed a higher cell viability compared to the cells cultured with eluate derived from Coldpac (Yates Motloid). These results highlighted the lower pro-inflammatory action and improved cell biocompatibility of ProTemp 4™ (3M ESPE ™), suggesting a better performance in terms of cells-material interaction.


Assuntos
Resinas Compostas , Fibroblastos , Gengiva , Interleucina-1beta , Polimetil Metacrilato , Humanos , Fibroblastos/efeitos dos fármacos , Fibroblastos/metabolismo , Gengiva/citologia , Resinas Compostas/farmacologia , Resinas Compostas/química , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Interleucina-1beta/metabolismo , Proteína 3 que Contém Domínio de Pirina da Família NLR/metabolismo , Células Cultivadas , Fator de Transcrição RelA/metabolismo , Adesão Celular/efeitos dos fármacos
4.
J Dent ; 145: 104993, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38657724

RESUMO

OBJECTIVES: This study aimed to compare the physical and mechanical properties of four denture base materials: Polyan IC (PA), milled polymethylmethacrylate (PMMA), three-dimensional (3D)-printed resin (3DP), and SR Ivocap (SR). METHODS: Ninety-six samples were prepared and divided into four groups as follows. Group A consisted of 3DP (Asiga DentaBASE, Asiga) fabricated using a manufacturer-recommended 3D printer (Asiga Pro 4k, Asiga). Group B comprised milled PMMA (MP) (Ivotion Base, Ivoclar Vivadent). Group C included PA (BredentSenden), meanwhile, group D involved SR (Ivoclar VivadentSchaan). Cuboid samples (65 mm x 10 mm x 2.5 mm) were used for biaxial flexure strength testing in a universal testing machine (UTM). Cylindrical samples of 20 mm x 40 mm were used for compressive strength testing in a UTM. Additionally, cuboid samples (65 mm x 10 mm x 2.5 mm) were used for Vickers surface hardness testing in a microhardness tester. disk samples (10 mm x 2.5 mm) were employed for color stability testing both in a coffee solution and Coca-Cola, using a digital spectrophotometer. Statistical analyses were performed using one-way analysis of variance and Tukey's post hoc analysis (α=0.05). RESULTS: MP demonstrated superior compressive strength (p = 0.002) and color stability compared to that exhibited by 3DP (p < 0.001) while displaying similar flexure strength (p = 0.336) and hardness (p = 0.708). MP and PA displayed similar compressive strength (p = 0.081), flexure strength (p = 0.159), and color stability in coke (p = 0.071). However, MP had reduced hardness (p < 0.001) and color stability in coffee (p < 0.001). Moreover, MP demonstrated a higher compressive strength (p < 0.001) than that displayed by SR. However, the flexure strength, hardness, and color stability were similar (p > 0.05). Furthermore, 3DP exhibited comparable compressive strength (p = 0.334) to that of PA but demonstrated significantly lower flexure strength (p = 0.005), hardness (p < 0.001), and color stability (p < 0.001) compared to PA. In comparison to SR, PA had a higher compressive strength (p < 0.001), hardness (p = 0.001), and color stability in coffee (p < 0.001), although they demonstrated similar (p > 0.05) flexure strength and color stability in coke. CONCLUSIONS: The MP and PA demonstrated superior compressive strength than that exhibited by the other materials tested. The tested materials had similar flexure strengths, except for PA which demonstrated superiority over the 3DP. Among all tested materials, PA exhibited the highest hardness, while the 3DP was the least color-stable. CLINICAL SIGNIFICANCE: Considering the mechanical properties and color stability, Polyan and milled polymethylmethacrylate are preferred for complete denture fabrication. However, the limited repairability and complex handling of Polyan should be considered.


Assuntos
Cor , Materiais Dentários , Bases de Dentadura , Dureza , Teste de Materiais , Polimetil Metacrilato , Propriedades de Superfície , Polimetil Metacrilato/química , Materiais Dentários/química , Força Compressiva , Resinas Acrílicas/química , Impressão Tridimensional , Humanos , Estresse Mecânico , Análise do Estresse Dentário , Resistência à Flexão
5.
ANZ J Surg ; 94(4): 724-732, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38572937

RESUMO

INTRODUCTION: Surgical glove perforation has been linked to a double-fold increased risk of surgical site infection. Infection in the context of arthroplasty can have devastating consequences. In orthopaedics, use of polymethyl methacrylate (PMMA) bone cement is commonplace, and the impact on glove strength and perforation risk is not fully understood. This study aimed to examine the resistance to perforation and thickness of gloves following PMMA exposure, in accordance with the International Organization for Standardization (ISO) standard for glove integrity. METHODS: Pairs of gloves were separated and randomly sorted into exposure and control groups. Twenty pairs of latex and 40 pairs of polyisoprene gloves were used. Exposure group glove cuffs were in contact with cement from a single surface of the glove for 13 min as cement cured. Force to perforation and glove thickness were tested in accordance with ISO guidelines. RESULTS: Latex gloves were found to have a significantly increased force to perforation following PMMA exposure (10.26 Newtons (N) vs. 9.81 N, P = 0.048). Both polyisoprene under- and over-gloves were shown to have no significant change in strength to perforation post exposure (9.69 N vs. 9.83 N, P = 0.561, and 10.26 N vs. 10.65 N, P = 0.168, respectively). All groups were over the ISO standard minimum strength of 5 N. CONCLUSIONS: Exposure of latex and polyisoprene surgical gloves to PMMA bone cement does not appear to increase glove perforation risk and rather may improve natural rubber latex glove strength. This study supports the use of latex and polyisoprene surgical gloves in procedures that involve the handling of PMMA bone cement.


Assuntos
Luvas Cirúrgicas , Ortopedia , Humanos , Polimetil Metacrilato/efeitos adversos , Cimentos Ósseos/efeitos adversos , Látex
6.
J Mater Chem B ; 12(18): 4389-4397, 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38623831

RESUMO

A robust and easily manufactured high-strength and long-term release hydrazone-based isoniazid acrylic (HIA) bone cement is reported. The mechanical strength of HIA bone cement is similar to that of normal polymethyl methacrylate (PMMA) bone cement, far surpassing that of traditional isoniazid-containing antibiotic-loaded bone cement (INH bone cement). Isoniazid is connected to the bone cement through bioorthogonal hydrazone chemistry, and it possesses release properties superior to those of INH bone cement, allowing for the sustained release of isoniazid for up to 12 weeks. In vivo and in vitro studies also indicate that HIA cement exhibits better biocompatibility than INH bone cement. The results of this study not only signify progress in the realm of antimicrobial bone cement for addressing bone tuberculosis but also enhance our capacity to create and comprehend high-performing antimicrobial bone cement.


Assuntos
Cimentos Ósseos , Hidrazonas , Isoniazida , Isoniazida/química , Isoniazida/farmacologia , Cimentos Ósseos/química , Animais , Hidrazonas/química , Hidrazonas/farmacologia , Antituberculosos/química , Antituberculosos/farmacologia , Antituberculosos/administração & dosagem , Camundongos , Liberação Controlada de Fármacos , Polimetil Metacrilato/química , Teste de Materiais , Materiais Biocompatíveis/química , Materiais Biocompatíveis/farmacologia
7.
Biomed Mater ; 19(4)2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38653261

RESUMO

Artificial bone graft with osteoconductivity, angiogenesis, and immunomodulation is promising clinical therapeutics for the reluctant healing process of bone defects. Among various osteogenic substitutes, polymethyl methacrylate (PMMA) bone cement is a quit competitive platform due to its easy deployment to the bone defects with irregular shape and biomimetic mechanical properties. However, the biologically inert essence of PMMA is reliant on the passive osseointegration and cannot provide sufficient biologic cues to induce fast bone repair. Bioactive glass could serve as an efficient platform for the active osteogenesis of PMMA via ionic therapy and construction of alkaline microenvironment. However, the direct of deployment of bioactive glass into PMMA may trigger additional cytotoxicity and hinder cell growth on its surface. Hence we incorporated ionic therapy as osteogenic cue into the PMMA to enhance the biomedical properties. Specifically, we synthesized core-shell microspheres with a strontium-doped bioactive glass (SrBG) core and hydroxyapatite (HA) shell, and then composited them with PMMA to introduce multifunctional effects of HA incorporation, alkaline microenvironment construction, and functional ion release by adding microsphere. We preparedxSrBG@HA/PMMA cements (x= 30, 40, 50) with varied microsphere content and evaluated impacts on mechanical/handling properties, ion release, and investigated the impacts of different composite cements on proliferation, osteogenic differentiation, angiogenic potential, and macrophage polarization. These findings provide new perspectives and methodologies for developing advanced bone biomaterials to promote tissue regeneration.


Assuntos
Cimentos Ósseos , Durapatita , Microesferas , Osteogênese , Polimetil Metacrilato , Estrôncio , Cimentos Ósseos/química , Polimetil Metacrilato/química , Osteogênese/efeitos dos fármacos , Porosidade , Estrôncio/química , Animais , Camundongos , Durapatita/química , Materiais Biocompatíveis/química , Teste de Materiais , Proliferação de Células/efeitos dos fármacos , Osseointegração/efeitos dos fármacos , Diferenciação Celular/efeitos dos fármacos , Cerâmica/química , Vidro/química , Humanos , Substitutos Ósseos/química
8.
Biosens Bioelectron ; 257: 116312, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38657380

RESUMO

Pre-eclampsia (PE) is a life-threatening complication that occurs during pregnancy, affecting a large number of pregnant women and newborns worldwide. Rapid, on-site and affordable screening of PE at an early stage is necessary to ensure timely treatment and minimize both maternal and neonatal morbidity and mortality rates. Placental growth factor (PlGF) is an angiogenic blood biomarker used for PE diagnosis. Herein, we report the plasmonic fiber optic absorbance biosensor (P-FAB) strategy for detecting PlGF at femtomolar concentration using polymethyl methacrylate (PMMA) based U-bent polymeric optical fiber (POF) sensor probes. A novel poly(amidoamine) (PAMAM) dendrimer based PMMA surface modification is established to obtain a greater immobilization of the bioreceptors compared to a linear molecule like hexamethylenediamine (HMDA). Plasmonic sandwich immunoassay was realized by immobilizing the mouse anti-PlGF (3H1) on the U-bent POF sensor probe surface and gold nanoparticles (AuNP) labels conjugated with mouse anti-PlGF (6H9). The POF sensor probes could measure PlGF within 30 min using the P-FAB strategy. The limit-of-detection (LoD) was found to be 0.19 pg/mL and 0.57 pg/mL in phosphate-buffered saline and 10× diluted serum, respectively. The clinical sample testing, with eleven positive and eleven negative preeclamptic pregnancy samples, successfully confirmed the accuracy, reliability, specificity, and sensitivity of the P-FAB based POF sensor platform, thereby paving the way for cost-effective technology for PlGF detection and its potential for pre-eclampsia diagnosis.


Assuntos
Técnicas Biossensoriais , Dendrímeros , Ouro , Nanopartículas Metálicas , Fibras Ópticas , Fator de Crescimento Placentário , Pré-Eclâmpsia , Pré-Eclâmpsia/diagnóstico , Pré-Eclâmpsia/sangue , Gravidez , Feminino , Humanos , Dendrímeros/química , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Fator de Crescimento Placentário/sangue , Ouro/química , Nanopartículas Metálicas/química , Limite de Detecção , Imunoensaio/métodos , Imunoensaio/instrumentação , Tecnologia de Fibra Óptica/instrumentação , Animais , Camundongos , Polimetil Metacrilato/química
9.
Clin Exp Dent Res ; 10(2): e842, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38597122

RESUMO

OBJECTIVE: To investigate the effect of common beverages on four currently used provisional restoration materials: Protemp®4, Integrity®, polymethyl methacrylate (PMMA) block, and acrylic resin. Flowable resin composite is included as a control group. MATERIALS AND METHODS: Each material was formed into disks of 10-mm diameter and 4-mm thickness (N = 40) by loading the material into acrylic molds. The exposed surface in the mold was covered using a glass slide to prevent an oxygen inhibition layer, and polymerization then proceeded. The solidified disks were placed in distilled water for 24 h. These samples (n = 8) were then immersed for 14 days in one of four different beverages: water, orange juice, cola, and coffee. Changes in color dimension, hardness, and roughness were observed and then analyzed using two-way repeated analysis of variance. RESULTS: The provisional materials had more obvious changes in all three color dimensions than the flowable resin composite. Integrity showed the biggest changes, followed by acrylic resin and PMMA block, whereas Protemp had the smallest changes. The hardness of all the materials significantly decreased after immersion in any of the beverages for 14 days. There were no changes in surface roughness when the materials were immersed in distilled water. The surface roughness of the PMMA block significantly decreased in orange juice whereas that of Integrity and acrylic resin significantly increased in cola. CONCLUSION: Different kinds of provisional materials had different degrees of staining due to their composition. Moisture had a significant influence on the hardness of materials, and the acidity of cola significantly roughened the surface of the provisional materials.


Assuntos
Bebidas , Polimetil Metacrilato , Resinas Acrílicas , Café , Água
10.
Phys Med Biol ; 69(11)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38657638

RESUMO

Objective. Prompt gamma timing (PGT) uses the detection time of prompt gammas emitted along the range of protons in proton radiotherapy to verify the position of the Bragg peak (BP). Cherenkov detectors offer the possibility of enhanced signal-to-noise ratio (SNR) due to the inherent physics of Cherenkov emission which enhances detection of high energy prompt gamma rays relative to other induced uncorrelated signals. In this work, the PGT technique was applied to 3 semiconductor material slabs that emit only Cherenkov light for use in a full scale system: a 3 × 3 × 20 mm3TlBr, a 12 × 12 × 12 mm3TlBr, and a 5 × 5 × 5 mm3TlCl.Approach. A polymethyl methacrylate (PMMA) target was exposed to a 67.5 MeV, 0.5 nA proton beam and shifted in 3 mm increments at the Crocker nuclear laboratory (CNL) in Davis, CA, USA. A fast plastic scintillator coupled to a photomultiplier tube (PMT) provided the start reference for the proton time of flight. Time of flight (TOF) distributions were generated using this reference and the gamma-ray timestamp in the Cherenkov detector.Main results. The SNR of the proton correlated peaks relative to the background was 20, 29, and 30 for each of the three samples, respectively. The upper limit of the position resolutions with the TlCl sample were 2 mm, 3 mm, and 5 mm for 30k, 10k, and 5k detected events, respectively. The time distribution of events with respect to the reference reproduced with clarity the periodicity of the beam, implying a very high SNR of the Cherenkov crystals to detect prompt gammas. Background presence from the neutron-induced continuum, prompt gammas from deuterium, or positron activation were not observed. Material choice and crystal dimensions did not seem to affect significantly the outcome of the results.Significance. These results show the high SNR of the pure Cherenkov emitters TlBr and TlCl for the detection of prompt gammas in a proton beam with current of clinical significance and their potential for verifying the proton range. The accuracy in determining shifts of the BP was highly dependent on the number of events acquired, therefore, the performance of these detectors are expected to vary with different beam conditions such as current, pulse repetition, and proton bunch width.


Assuntos
Raios gama , Terapia com Prótons , Fatores de Tempo , Terapia com Prótons/instrumentação , Tálio , Lutécio/química , Prótons , Polimetil Metacrilato/química
11.
Lab Chip ; 24(10): 2721-2735, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38656267

RESUMO

We report the generation of ∼8 nm dual in-plane pores fabricated in a thermoplastic via nanoimprint lithography (NIL). These pores were connected in series with nanochannels, one of which served as a flight tube to allow the identification of single molecules based on their molecular-dependent apparent mobilities (i.e., dual in-plane nanopore sensor). Two different thermoplastics were investigated including poly(methyl methacrylate), PMMA, and cyclic olefin polymer, COP, as the substrate for the sensor both of which were sealed using a low glass transition cover plate (cyclic olefin co-polymer, COC) that could be thermally fusion bonded to the PMMA or COP substrate at a temperature minimizing nanostructure deformation. Unique to these dual in-plane nanopore sensors was two pores flanking each side of the nanometer flight tube (50 × 50 nm, width × depth) that was 10 µm in length. The utility of this dual in-plane nanopore sensor was evaluated to not only detect, but also identify single ribonucleotide monophosphates (rNMPs) by using the travel time (time-of-flight, ToF), the resistive pulse event amplitude, and the dwell time. In spite of the relatively large size of these in-plane pores (∼8 nm effective diameter), we could detect via resistive pulse sensing (RPS) single rNMP molecules at a mass load of 3.9 fg, which was ascribed to the unique structural features of the nanofluidic network and the use of a thermoplastic with low relative dielectric constants, which resulted in a low RMS noise level in the open pore current. Our data indicated that the identification accuracy of individual rNMPs was high, which was ascribed to an improved chromatographic contribution to the nano-electrophoresis apparent mobility. With the ToF data only, the identification accuracy was 98.3%. However, when incorporating the resistive pulse sensing event amplitude and dwell time in conjunction with the ToF and analyzed via principal component analysis (PCA), the identification accuracy reached 100%. These findings pave the way for the realization of a novel chip-based single-molecule RNA sequencing technology.


Assuntos
Nanoporos , Ribonucleotídeos/química , Ribonucleotídeos/análise , Temperatura , Polimetil Metacrilato/química
12.
Environ Sci Pollut Res Int ; 31(20): 28890-28904, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38564126

RESUMO

Inappropriate disposal of plastic wastes and their durability in nature cause uncontrolled accumulation of plastic in land/marine ecosystems, also causing destructive effects by bioaccumulating along the food chain. Microplastics may cause chronic inflammation in relation to their permanent structures, especially through oxidative stress and cytotoxic cellular damage, which could increase the risk of cancer development. The accumulation of microplastics in the liver is a major concern, and therefore, the identification of the mechanisms of their hepatotoxic effects is of great importance. Polymethyl methacrylate (PMMA) is a widely used thermoplastic. It has been determined that PMMA disrupts lipid metabolism in the liver in various aquatic organisms and causes reproductive and developmental toxicity. PMMA-induced hepatotoxic effects in humans have not yet been clarified. In our study, the toxic effects of PMMA (in the range of 3-10 µm) on the human liver were investigated using the HepG2/THP-1 macrophage co-culture model, which is a sensitive immune-mediated liver injury model. Cellular uptake of micro-sized PMMA in the cells was done by transmission electron microscopy. Determination of its effects on cell viability and inflammatory response, oxidative stress, along with gene and protein expression levels that play a role in the mechanism pathways underlying the effects were investigated. The results concluded that inflammation, oxidative stress, and disruptions in lipid metabolism should be the focus of attention as important underlying causes of PMMA-induced hepatotoxicity. Our study, which points out the potential adverse effects of microplastics on human health, supports the literature information on the subject.


Assuntos
Microplásticos , Estresse Oxidativo , Polimetil Metacrilato , Humanos , Polimetil Metacrilato/toxicidade , Microplásticos/toxicidade , Células Hep G2 , Estresse Oxidativo/efeitos dos fármacos , Técnicas de Cocultura , Fígado/efeitos dos fármacos
13.
ACS Sens ; 9(5): 2455-2464, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38687557

RESUMO

In this study, we demonstrate whole blood immunoassays using a microfluidic device optimized for conducting rapid and multiplexed fluorescence-linked immunoassays. The device is capable of handling whole blood samples without any preparatory treatment. The three-dimensional channels in poly(methyl methacrylate) are designed to passively load bodily fluids and, due to their linearly tapered profile, facilitate size-dependent immobilization of biofunctionalized particles. The channel geometry is optimized to allow for the unimpeded flow of cellular constituents such as red blood cells (RBCs). Additionally, to make the device easier to operate, the biofunctionalized particles are pretrapped in a first step, and the channel is dried under vacuum, after which it can be loaded with the biological sample. This novel approach and design eliminated the need for traditionally laborious steps such as filtering, incubation, and washing steps, thereby substantially simplifying the immunoassay procedures. Moreover, by leveraging the shallow device dimensions, we show that sample loading to read-out is possible within 5 min. Our results also show that the presence of RBCs does not compromise the sensitivity of the assays when compared to those performed in a pure buffer solution. This highlights the practical adaptability of the device for simple and rapid whole-blood assays. Lastly, we demonstrate the device's multiplexing capability by pretrapping particles of different sizes, each functionalized with a different antigen, thus enabling the performance of multiplexed on-chip whole-blood immunoassays, showcasing the device's versatility and effectiveness toward low-cost, simple, and multiplexed sensing of biomarkers and pathogens directly in whole blood.


Assuntos
Técnicas Analíticas Microfluídicas , Humanos , Imunoensaio/métodos , Imunoensaio/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Eritrócitos/química , Dispositivos Lab-On-A-Chip , Polimetil Metacrilato/química
14.
Bone Joint J ; 106-B(5): 435-441, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688480

RESUMO

Aims: Refobacin Bone Cement R and Palacos R + G bone cement were introduced to replace the original cement Refobacin Palacos R in 2005. Both cements were assumed to behave in a biomechanically similar fashion to the original cement. The primary aim of this study was to compare the migration of a polished triple-tapered femoral stem fixed with either Refobacin Bone Cement R or Palacos R + G bone cement. Repeated radiostereometric analysis was used to measure migration of the femoral head centre. The secondary aims were evaluation of cement mantle, stem positioning, and patient-reported outcome measures. Methods: Overall, 75 patients were included in the study and 71 were available at two years postoperatively. Prior to surgery, they were randomized to one of the three combinations studied: Palacos cement with use of the Optivac mixing system, Refobacin with use of the Optivac system, and Refobacin with use of the Optipac system. Cemented MS30 stems and cemented Exceed acetabular components were used in all hips. Postoperative radiographs were used to assess the quality of the cement mantle according to Barrack et al, and the position and migration of the femoral stem. Harris Hip Score, Oxford Hip Score, Forgotten Joint Score, and University of California, Los Angeles Activity Scale were collected. Results: Median distal migration (y-axis) at two years for the Refobacin-Optivac system was -0.79 mm (-2.01 to -0.09), for the Refobacin-Optipac system was -0.75 mm (-2.16 to 0.20), and for the Palacos-Optivac system was -1.01 mm (-4.31 to -0.29). No statistically significant differences were found between the groups. Secondary outcomes did not differ statistically between the groups at the two-year follow-up. Conclusion: At two years, we found no significant differences in distal migration or clinical outcomes between the three groups. Our data indicate that Refobacin Bone Cement R and Palacos R + G are comparable in terms of stable fixation and early clinical outcomes.


Assuntos
Artroplastia de Quadril , Cimentos Ósseos , Prótese de Quadril , Humanos , Masculino , Feminino , Estudos Prospectivos , Artroplastia de Quadril/métodos , Artroplastia de Quadril/instrumentação , Idoso , Pessoa de Meia-Idade , Análise Radioestereométrica , Falha de Prótese , Desenho de Prótese , Medidas de Resultados Relatados pelo Paciente , Idoso de 80 Anos ou mais , Polimetil Metacrilato
15.
J Proteome Res ; 23(5): 1810-1820, 2024 May 03.
Artigo em Inglês | MEDLINE | ID: mdl-38634750

RESUMO

Liquid chromatography-tandem mass spectrometry (LC-MS/MS) is a widely employed technique in proteomics research for studying the proteome biology of various clinical samples. Hard tissues, such as bone and teeth, are routinely preserved using synthetic poly(methyl methacrylate) (PMMA) embedding resins that enable histological, immunohistochemical, and morphological examination. However, the suitability of PMMA-embedded hard tissues for large-scale proteomic analysis remained unexplored. This study is the first to report on the feasibility of PMMA-embedded bone samples for LC-MS/MS analysis. Conventional workflows yielded merely limited coverage of the bone proteome. Using advanced strategies of prefractionation by high-pH reversed-phase liquid chromatography in combination with isobaric tandem mass tag labeling resulted in proteome coverage exceeding 1000 protein identifications. The quantitative comparison with cryopreserved samples revealed that each sample preparation workflow had a distinct impact on the proteomic profile. However, workflow replicates exhibited a high reproducibility for PMMA-embedded samples. Our findings further demonstrate that decalcification prior to protein extraction, along with the analysis of solubilization fractions, is not preferred for PMMA-embedded bone. The biological applicability of the proposed workflow was demonstrated using samples of human PMMA-embedded alveolar bone and the iliac crest, which revealed anatomical site-specific proteomic profiles. Overall, these results establish a crucial foundation for large-scale proteomics studies contributing to our knowledge of bone biology.


Assuntos
Polimetil Metacrilato , Proteômica , Espectrometria de Massas em Tandem , Proteômica/métodos , Humanos , Polimetil Metacrilato/química , Espectrometria de Massas em Tandem/métodos , Proteoma/análise , Cromatografia Líquida/métodos , Osso e Ossos/química , Osso e Ossos/metabolismo , Inclusão do Tecido/métodos , Reprodutibilidade dos Testes
16.
Anal Chem ; 96(17): 6764-6773, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38619911

RESUMO

Tremendous efforts have been made to develop practical and efficient microfluidic cell and particle sorting systems; however, there are technological limitations in terms of system complexity and low operability. Here, we propose a sheath flow generator that can dramatically simplify operational procedures and enhance the usability of microfluidic cell sorters. The device utilizes an embedded polydimethylsiloxane (PDMS) sponge with interconnected micropores, which is in direct contact with microchannels and seamlessly integrated into the microfluidic platform. The high-density micropores on the sponge surface facilitated fluid drainage, and the drained fluid was used as the sheath flow for downstream cell sorting processes. To fabricate the integrated device, a new process for sponge-embedded substrates was developed through the accumulation, incorporation, and dissolution of PMMA microparticles as sacrificial porogens. The effects of the microchannel geometry and flow velocity on the sheath flow generation were investigated. Furthermore, an asymmetric lattice-shaped microchannel network for cell/particle sorting was connected to the sheath flow generator in series, and the sorting performances of model particles, blood cells, and spiked tumor cells were investigated. The sheath flow generation technique developed in this study is expected to streamline conventional microfluidic cell-sorting systems as it dramatically improves versatility and operability.


Assuntos
Separação Celular , Técnicas Analíticas Microfluídicas , Humanos , Separação Celular/instrumentação , Separação Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Porosidade , Dimetilpolisiloxanos/química , Dispositivos Lab-On-A-Chip , Polimetil Metacrilato/química
17.
J Indian Prosthodont Soc ; 24(2): 165-174, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38650342

RESUMO

AIM: (1) To assess the release of stable silver nanoparticles (AgNPs) of small scale dimension added to heat polymerized polymethyl methacrylate (PMMA) in 6 months. (2) Assessing the influence of incorporating minimal concentrations of stable AgNPs with nanoscale dimensions into heat polymerized PMMA over a 6 month period on its antifungal efficacy (AF), flexural strength (FS), and impact strength (IS). SETTINGS AND DESIGN: Incorporating nanoparticles with a very small scale may have minimal impact on mechanical properties due to their diminutive size. However, the influence of these small scaled nanoparticles on antimicrobial efficacy and potential escalation in toxicity to host cells through leaching remains unexplored. AgNPs were prepared using an Ultrasonic Probe sonicator and the addition of ammonia to obtain stabilized AgNPs (< 0.01 nm) of small scale dimension. The characterization of these AgNPs involved ultraviolet visible spectroscopy, X ray diffraction, Zetasizer, and transmission electron microscopy with energy dispersive spectroscopy (TEM). MATERIALS AND METHODS: The prepared AgNPs were then added in various percentages by weight (0%-0.5%) to fabricate 252 modified PMMA samples of sizes 10 mm × 3 mm (AF, n = 108), 65 mm × 10 mm × 3 mm (FS, n = 72), and 65 mm × 10 mm × 2.5 mm (IS, n = 72) as per ADA specification no. 12. These samples underwent testing for leaching out of AgNPs and efficacy against Candida albicans for 6 months. The effect on FS and IS was evaluated using the three point bending test and Charpy's Impact Tester, respectively. STATISTICAL ANALYSIS USED: Intergroup comparison of CFU between various concentrations of AgNP was done using the Kruskal-Wallis ANOVA test succeeded by Mann-Whitney test for pair wise comparisons. Difference in CFU of various concentrations over 6 months was seen using one way ANOVA test. Intergroup comparison of FS and IS was performed using a one way ANOVA test, followed by a post hoc Tukey's test for pair wise comparisons. RESULTS: Repeated tests showed no leaching out of AgNPs from the denture base resin into the storage medium. All concentrations of AgNPs incorporated in resin showed inhibition of Candida growth. Intergroup comparison of FS and IS revealed highly statistically significant differences (F = 15.076, P < 0.01 and F = 28.266, P < 0.01) between the groups showing a reduction in strength. CONCLUSION: The AgNPs of small scale dimension incorporated into the denture base resin imparted a strong antifungal effectiveness against C. albicans, which did not decline during the study period and did not cause any release of nanoparticles. 0.5% showed the best antifungal efficacy. This may prove to be a viable and highly effective treatment for the prevention of Candida associated denture stomatitis. However, the inclusion of these particles resulted in a decrease in both FS and IS, and this reduction was directly proportional to the percentage of added AgNPs, with 0.5% demonstrating the least IS and FS.


Assuntos
Antifúngicos , Resistência à Flexão , Nanopartículas Metálicas , Polimetil Metacrilato , Prata , Polimetil Metacrilato/química , Polimetil Metacrilato/farmacologia , Prata/química , Prata/farmacologia , Nanopartículas Metálicas/química , Antifúngicos/farmacologia , Antifúngicos/química , Candida albicans/efeitos dos fármacos , Teste de Materiais , Técnicas In Vitro , Microscopia Eletrônica de Transmissão
18.
Water Res ; 254: 121397, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38461599

RESUMO

Municipal wastewater treatment plants (WWTPs) play a crucial role in the collection and redistribution of plastic particles from both households and industries, contributing to their presence in the environment. Previous studies investigating the levels of plastics in WWTPs, and their removal rates have primarily focused on polymer type, size, shape, colour, and particle count, while comprehensive understanding of the mass concentration of plastic particles, particularly those <1 µm (nanoplastics), remains unclear and lacking. In this study, pyrolysis gas chromatography-mass spectrometry was used to simultaneously determine the mass concentration of nine selected polymers (i.e., polyethylene (PE), polypropylene (PP), polystyrene (PS), poly(ethylene terephthalate) (PET), nylon 6, nylon 66, polyvinylchloride (PVC), poly(methyl methacrylate) (PMMA) and polycarbonate (PC)) below 1 µm in size across the treatment processes or stages of three WWTPs in Australia. All the targeted nanoplastics were detected at concentrations between 0.04 and 7.3 µg/L. Nylon 66 (0.2-7.3 µg/L), PE (0.1-6.6 µg/L), PP (0.1-4.5 µg/L), Nylon 6 (0.1-3.6 µg/L) and PET (0.1-2.2 µg/L), were the predominant polymers in the samples. The mass concentration of the total nanoplastics decreased from 27.7, 18 and 9.1 µg/L in the influent to 1, 1.4 and 0.8 µg/L in the effluent, with approximate removal rates of 96 %, 92 % and 91 % in plants A, B and C, respectively. Based on annual wastewater effluent discharge, it is estimated that approximately 24, 2 and 0.7 kg of nanoplastics are released into the environment per year for WWTPs A, B and C, respectively. This study investigated the mass concentrations and removal rates of nanoplastics with a size range of 0.01-1 µm in wastewater, providing important insight into the pollution levels and distribution patterns of nanoplastics in Australian WWTPs.


Assuntos
Caprolactama/análogos & derivados , Polímeros , Poluentes Químicos da Água , Purificação da Água , Águas Residuárias , Microplásticos , Nylons , Pirólise , Cromatografia Gasosa-Espectrometria de Massas , Austrália , Plásticos/análise , Polipropilenos/análise , Polimetil Metacrilato , Polietilenos , Poluentes Químicos da Água/química , Monitoramento Ambiental
19.
Colloids Surf B Biointerfaces ; 237: 113864, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38522283

RESUMO

Electrospun polymer scaffolds have gained prominence in biomedical applications, including tissue engineering, drug delivery, and wound dressings, due to their customizable properties. As the interplay between cells and materials assumes fundamental significance in biomaterials research, understanding the relationship between fiber properties and cell behaviour is imperative. Nevertheless, altering fiber properties introduces complexity by intertwining mechanical and surface chemistry effects, challenging the differentiation of their individual impacts on cell behaviour. Core-shell fibers present an appealing solution, enabling the control of mechanical properties of scaffolds, flexibility in material and drug selection, efficient encapsulation, strong protection of bioactive drugs against harsh environments, and controlled, prolonged drug release. This study addresses a key challenge in core-shell fiber design related to the blending effect between core and shell polymers. Two types of fibers, PMMA and core-shell PC-PMMA, were electrospun, and thorough analyses confirmed the desired core-shell structure in PC-PMMA fibers. Surface chemistry analysis revealed PC diffusion to the PMMA shell of the core-shell fiber during electrospinning, subsequently prompting an investigation of the fiber's surface potential. Conducting cellular studies on osteoblasts by super-resolution confocal microscopy provided insights into the direct influence of interfacial polymer blending and, consequently, altered fiber surface and mechanical properties on cell focal adhesion points, bridging the gap between material attributes and cell responses in core-shell fibers.


Assuntos
Polímeros , Polimetil Metacrilato , Polímeros/química , Polimetil Metacrilato/química , Adesões Focais , Engenharia Tecidual , Materiais Biocompatíveis/química , Alicerces Teciduais/química
20.
PLoS One ; 19(3): e0299325, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38457423

RESUMO

PURPOSE: Vertebral compression fractures are often treated with vertebroplasty, and filling the injured vertebrae with bone cement is a key part of vertebroplasty. This meta-analysis was performed to compare the clinical efficacy and safety of mineralized collagen-polymethylmethacrylate (MC-PMMA) and polymethylmethacrylate (PMMA) bone cement in the treatment of vertebral compression fractures by vertebroplasty. METHODS: A computerized search of the published literature on mineralized collagen-polymethylmethacrylate and polymethylmethacrylate bone cement in the treatment of vertebral compression fractures was conducted in the China National Knowledge Infrastructure (CNKI), Wanfang database, PubMed, Embase, and Cochrane Library. The search was carried out from the time the database was created to March 2023 and 2 researchers independently conducted literature searches to retrieve a total of 884 studies, of which 12 were included in this meta-analysis. Cochrane systematic review methods were used to assess the quality of the literature and a meta-analysis was performed using ReviewManager 5.4 software. RESULTS: The results of the present meta-analysis showed that in postoperative adjacent vertebral fractures [OR = 0.25; 95% CI (0.15, 0.41)], postoperative cement leakage [OR = 0.45; 95% CI (0.30, 0.68)], Oswestry Disability Index (ODI) scores in the first 3 days after surgery [OR = -0.22; 95% CI (-0.42, -0.03)], ODI score at 6-12 months postoperatively [OR = -0.65; 95% CI (-0.97, -0.32)], visual analog scale (VAS) score at 6-12 months postoperatively [OR = -0.21; 95% CI (-0.46, 0.04)], and 1-year postoperative CT values [OR = 5.56; 95% CI (3.06, 8.06)], the MC-PMMA bone cement group was superior to the PMMA bone cement group. However, the differences between the two groups were not statistically different in terms of cement filling time, cement filling volume, operation time, intraoperative bleeding, hospitalization time, postoperative (<1 week, 3-6 months) vertebral body posterior convexity Cobb's angle, postoperative (<1 week, 6-12 months) vertebral body anterior margin relative height, postoperative (≤3 days, 1-3 months) pain VAS score and postoperative (1-3 months) ODI score. CONCLUSIONS: Compared with PMMA bone cement, the application of MC-PMMA bone cement is advantageous in reducing postoperative complications (adjacent vertebral fracture rate, cement leakage rate), pain relief, and functional recovery in the long-term postoperative period (>6 months), but there is still a need for more high-quality randomized controlled studies to provide more adequate evidence.


Assuntos
Fraturas por Compressão , Cifoplastia , Fraturas por Osteoporose , Fraturas da Coluna Vertebral , Vertebroplastia , Humanos , Cimentos Ósseos/uso terapêutico , Cimentos Ósseos/química , Colágeno , Fraturas por Compressão/cirurgia , Cifoplastia/métodos , Fraturas por Osteoporose/cirurgia , Dor/tratamento farmacológico , Polimetil Metacrilato/uso terapêutico , Polimetil Metacrilato/química , Fraturas da Coluna Vertebral/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA