Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 4.358
Filtrar
1.
Respir Res ; 25(1): 197, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38715026

RESUMO

BACKGROUND AND OBJECTIVES: OSA is a known medical condition that is associated with several comorbidities and affect patients' quality of life. The association between OSA and lung cancer remains debated. Some studies reported increased prevalence of OSA in patients with lung cancer. We aimed to assess predictors of moderate-to-severe OSA in patients with lung cancer. METHODS: We enrolled 153 adult patients who were newly diagnosed with lung cancer. Cardiorespiratory monitoring was performed using home sleep apnea device. We carried out Univariate and multivariate logistic regression analysis on multiple parameters including age, gender, smoking status, neck circumference, waist circumference, BMI, stage and histopathology of lung cancer, presence of superior vena cava obstruction, and performance status to find out the factors that are independently associated with a diagnosis of moderate-to-severe OSA. RESULTS: Our results suggest that poor performance status is the most significant predictor of moderate to severe OSA in patients with lung cancer after controlling for important confounders. CONCLUSION: Performance status is a predictor of moderate to severe OSA in patients with lung cancer in our population of middle eastern ethnicity.


Assuntos
Neoplasias Pulmonares , Índice de Gravidade de Doença , Apneia Obstrutiva do Sono , Humanos , Masculino , Feminino , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Pessoa de Meia-Idade , Neoplasias Pulmonares/epidemiologia , Neoplasias Pulmonares/diagnóstico , Idoso , Valor Preditivo dos Testes , Adulto , Fatores de Risco , Polissonografia/métodos
2.
Sensors (Basel) ; 24(9)2024 Apr 27.
Artigo em Inglês | MEDLINE | ID: mdl-38732909

RESUMO

(1) Background: Home sleep apnea testing, known as polysomnography type 3 (PSG3), underestimates respiratory events in comparison with in-laboratory polysomnography type 1 (PSG1). Without head electrodes for scoring sleep and arousal, in a home environment, patients feel unfettered and move their bodies more naturally. Adopting a natural position may decrease obstructive sleep apnea (OSA) severity in PSG3, independently of missing hypopneas associated with arousals. (2) Methods: Patients with suspected OSA performed PSG1 and PSG3 in a randomized sequence. We performed an additional analysis, called reduced polysomnography, in which we blindly reassessed all PSG1 tests to remove electroencephalographic electrodes, electrooculogram, and surface electromyography data to estimate the impact of not scoring sleep and arousal-based hypopneas on the test results. A difference of 15 or more in the apnea-hypopnea index (AHI) between tests was deemed clinically relevant. We compared the group of patients with and without clinically relevant differences between lab and home tests (3) Results: As expected, by not scoring sleep, there was a decrease in OSA severity in the lab test, similar to the home test results. The group of patients with clinically relevant differences between lab and home tests presented more severe OSA in the lab compared to the other group (mean AHI, 42.5 vs. 20.2 events/h, p = 0.002), and this difference disappeared in the home test. There was no difference between groups in the shift of OSA severity by abolishing sleep scoring in the lab. However, by comparing lab and home tests, there were greater variations in supine AHI and time spent in the supine position in the group with a clinically relevant difference, either with or without scoring sleep, showing an impact of the site of the test on body position during sleep. These variations presented as a marked increase or decrease in supine outcomes according to the site of the test, with no particular trend. (4) Conclusions: In-lab polysomnography may artificially increase OSA severity in a subset of patients by inducing marked changes in body position compared to home tests. The location of the sleep test seems to interfere with the evaluation of patients with more severe OSA.


Assuntos
Polissonografia , Apneia Obstrutiva do Sono , Humanos , Polissonografia/métodos , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Masculino , Feminino , Pessoa de Meia-Idade , Postura/fisiologia , Adulto , Eletroencefalografia/métodos , Idoso
3.
J Vis Exp ; (206)2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38738908

RESUMO

Cognitive symptoms and sleep disturbance (SD) are common non-mood-related symptoms of major depressive disorder (MDD). In clinical practice, both cognitive symptoms and SD are related to MDD progression. However, there are only a few studies investigating the connection between cognitive symptoms and SD in patients with MDD, and only preliminary evidence suggests a significant association between cognitive symptoms and SD in patients with mood disorders. This study investigates the relationship between cognitive symptoms and sleep quality in patients with major depressive disorder. Patients (n = 20) with MDD were enrolled; their mean Hamilton Depression Scale-17 score was 21.95 (±2.76). Gold standard polysomnography (PSG) was used to assess sleep quality, and the validated THINC-integrated tool (the cognitive screening tool) was used to evaluate cognitive function in MDD patients. Overall, the results showed significant correlations between the cognitive screening tool's total score and sleep latency, wake-after-sleep onset, and sleep efficiency. These findings indicate that cognitive symptoms are associated with poor sleep quality among patients with MDD.


Assuntos
Cognição , Transtorno Depressivo Maior , Polissonografia , Qualidade do Sono , Humanos , Transtorno Depressivo Maior/psicologia , Adulto , Masculino , Feminino , Pessoa de Meia-Idade , Cognição/fisiologia , Polissonografia/métodos , Transtornos do Sono-Vigília/etiologia , Transtornos do Sono-Vigília/psicologia
4.
IEEE J Transl Eng Health Med ; 12: 448-456, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765887

RESUMO

OBJECTIVE: Sleep monitoring has extensively utilized electroencephalogram (EEG) data collected from the scalp, yielding very large data repositories and well-trained analysis models. Yet, this wealth of data is lacking for emerging, less intrusive modalities, such as ear-EEG. METHODS AND PROCEDURES: The current study seeks to harness the abundance of open-source scalp EEG datasets by applying models pre-trained on data, either directly or with minimal fine-tuning; this is achieved in the context of effective sleep analysis from ear-EEG data that was recorded using a single in-ear electrode, referenced to the ipsilateral mastoid, and developed in-house as described in our previous work. Unlike previous studies, our research uniquely focuses on an older cohort (17 subjects aged 65-83, mean age 71.8 years, some with health conditions), and employs LightGBM for transfer learning, diverging from previous deep learning approaches. RESULTS: Results show that the initial accuracy of the pre-trained model on ear-EEG was 70.1%, but fine-tuning the model with ear-EEG data improved its classification accuracy to 73.7%. The fine-tuned model exhibited a statistically significant improvement (p < 0.05, dependent t-test) for 10 out of the 13 participants, as reflected by an enhanced average Cohen's kappa score (a statistical measure of inter-rater agreement for categorical items) of 0.639, indicating a stronger agreement between automated and expert classifications of sleep stages. Comparative SHAP value analysis revealed a shift in feature importance for the N3 sleep stage, underscoring the effectiveness of the fine-tuning process. CONCLUSION: Our findings underscore the potential of fine-tuning pre-trained scalp EEG models on ear-EEG data to enhance classification accuracy, particularly within an older population and using feature-based methods for transfer learning. This approach presents a promising avenue for ear-EEG analysis in sleep studies, offering new insights into the applicability of transfer learning across different populations and computational techniques. CLINICAL IMPACT: An enhanced ear-EEG method could be pivotal in remote monitoring settings, allowing for continuous, non-invasive sleep quality assessment in elderly patients with conditions like dementia or sleep apnea.


Assuntos
Eletroencefalografia , Couro Cabeludo , Humanos , Eletroencefalografia/métodos , Idoso , Couro Cabeludo/fisiologia , Idoso de 80 Anos ou mais , Masculino , Feminino , Sono/fisiologia , Processamento de Sinais Assistido por Computador , Orelha/fisiologia , Aprendizado de Máquina , Polissonografia/métodos
5.
PLoS One ; 19(5): e0303076, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38758825

RESUMO

STUDY OBJECTIVE: This study aimed to prospectively validate the performance of an artificially augmented home sleep apnea testing device (WVU-device) and its patented technology. METHODOLOGY: The WVU-device, utilizing patent pending (US 20210001122A) technology and an algorithm derived from cardio-pulmonary physiological parameters, comorbidities, and anthropological information was prospectively compared with a commercially available and Center for Medicare and Medicaid Services (CMS) approved home sleep apnea testing (HSAT) device. The WVU-device and the HSAT device were applied on separate hands of the patient during a single night study. The oxygen desaturation index (ODI) obtained from the WVU-device was compared to the respiratory event index (REI) derived from the HSAT device. RESULTS: A total of 78 consecutive patients were included in the prospective study. Of the 78 patients, 38 (48%) were women and 9 (12%) had a Fitzpatrick score of 3 or higher. The ODI obtained from the WVU-device corelated well with the HSAT device, and no significant bias was observed in the Bland-Altman curve. The accuracy for ODI > = 5 and REI > = 5 was 87%, for ODI> = 15 and REI > = 15 was 89% and for ODI> = 30 and REI of > = 30 was 95%. The sensitivity and specificity for these ODI /REI cut-offs were 0.92 and 0.78, 0.91 and 0.86, and 0.94 and 0.95, respectively. CONCLUSION: The WVU-device demonstrated good accuracy in predicting REI when compared to an approved HSAT device, even in patients with darker skin tones.


Assuntos
Inteligência Artificial , Síndromes da Apneia do Sono , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Síndromes da Apneia do Sono/diagnóstico , Síndromes da Apneia do Sono/fisiopatologia , Idoso , Polissonografia/instrumentação , Polissonografia/métodos , Algoritmos , Adulto
6.
J Am Coll Cardiol ; 83(17): 1671-1684, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38573282

RESUMO

BACKGROUND: Delta wave activity is a prominent feature of deep sleep, which is significantly associated with sleep quality. OBJECTIVES: The authors hypothesized that delta wave activity disruption during sleep could predict long-term cardiovascular disease (CVD) and CVD mortality risk. METHODS: The authors used a comprehensive power spectral entropy-based method to assess delta wave activity during sleep based on overnight polysomnograms in 4,058 participants in the SHHS (Sleep Heart Health Study) and 2,193 participants in the MrOS (Osteoporotic Fractures in Men Study) Sleep study. RESULTS: During 11.0 ± 2.8 years of follow-up in SHHS, 729 participants had incident CVD and 192 participants died due to CVD. During 15.5 ± 4.4 years of follow-up in MrOS, 547 participants had incident CVD, and 391 died due to CVD. In multivariable Cox regression models, lower delta wave entropy during sleep was associated with higher risk of coronary heart disease (SHHS: HR: 1.46; 95% CI: 1.02-2.06; P = 0.03; MrOS: HR: 1.79; 95% CI: 1.17-2.73; P < 0.01), CVD (SHHS: HR: 1.60; 95% CI: 1.21-2.11; P < 0.01; MrOS: HR: 1.43; 95% CI: 1.00-2.05; P = 0.05), and CVD mortality (SHHS: HR: 1.94; 95% CI: 1.18-3.18; P < 0.01; MrOS: HR: 1.66; 95% CI: 1.12-2.47; P = 0.01) after adjusting for covariates. The Shapley Additive Explanations method indicates that low delta wave entropy was more predictive of coronary heart disease, CVD, and CVD mortality risks than conventional sleep parameters. CONCLUSIONS: The results suggest that delta wave activity disruption during sleep may be a useful metric to identify those at increased risk for CVD and CVD mortality.


Assuntos
Doenças Cardiovasculares , Polissonografia , Humanos , Masculino , Doenças Cardiovasculares/mortalidade , Doenças Cardiovasculares/fisiopatologia , Pessoa de Meia-Idade , Feminino , Polissonografia/métodos , Idoso , Ritmo Delta/fisiologia , Seguimentos , Sono/fisiologia
7.
Neurology ; 102(10): e209302, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38662978

RESUMO

BACKGROUND AND OBJECTIVES: Sleep disorders are a common and important clinical feature in patients with autoimmune encephalitis (AE); however, they are poorly understood. We aimed to evaluate whether cardiopulmonary coupling (CPC), an electrocardiogram-based portable sleep monitoring technology, can be used to assess sleep disorders in patients with AE. METHODS: Patients fulfilling the diagnostic criteria of AE were age- and sex-matched with recruited healthy control subjects. All patients and subjects received CPC testing between August 2020 and December 2022. Demographic data, clinical information, and Pittsburgh Sleep Quality Index (PSQI) scores were collected from the medical records. Data analysis was performed using R language programming software. RESULTS: There were 60 patients with AE (age 26.0 [19.8-37.5] years, male 55%) and 66 healthy control subjects (age 30.0 [25.8-32.0] years, male 53%) included in this study. Compared with healthy subjects, patients with AE had higher PSQI scores (7.00 [6.00-8.00] vs 3.00 [2.00-4.00], p < 0.001), lower sleep efficiency (SE 80% [71%-87%] vs 92% [84%-95%], p < 0.001), lower percentage of high-frequency coupling (25% [14%-43%] vs 45% [38%-53%], p < 0.001), higher percentage of REM sleep (19% ± 9% vs 15% ± 7%, p < 0.001), higher percentage of wakefulness (W% 16% [11%-25%] vs 8% [5%-16%], p = 0.074), higher low-frequency to high-frequency ratio (LF/HF 1.29 [0.82-2.40] vs 0.91 [0.67-1.29], p = 0.001), and a higher CPC-derived respiratory disturbance index (9.78 [0.50-22.2] vs 2.95 [0.40-6.53], p < 0.001). Follow-up evaluation of 14 patients showed a decrease in the PSQI score (8.00 [6.00-9.00] vs 6.00 [5.00-7.00], p = 0.008), an increased SE (79% [69%-86%] vs 89% [76%-91%], p = 0.030), and a decreased W% (20% [11%-30%] vs 11% [8%-24], p = 0.035). Multiple linear regression indicated that SE (-7.49 [-9.77 to -5.21], p < 0.001) and LF/HF ratio (0.37 [0.13-0.6], p = 0.004) were independent factors affecting PSQI scores in patients with AE. DISCUSSION: Sleep disorders with autonomic dysfunction are common in patients with AE. Improvements in the PSQI score and SE precede the restoration of sleep microstructural disruption in the remission stage. CPC parameters may be useful in predicting sleep disorders in patients with AE.


Assuntos
Encefalite , Transtornos do Sono-Vigília , Humanos , Masculino , Feminino , Adulto , Transtornos do Sono-Vigília/diagnóstico , Transtornos do Sono-Vigília/fisiopatologia , Adulto Jovem , Encefalite/diagnóstico , Encefalite/complicações , Encefalite/fisiopatologia , Doença de Hashimoto/complicações , Doença de Hashimoto/fisiopatologia , Doença de Hashimoto/diagnóstico , Eletrocardiografia/métodos , Polissonografia/métodos
9.
Sleep Med ; 118: 88-92, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38631159

RESUMO

STUDY OBJECTIVES: Obstructive sleep apnea (OSA) diagnosis relies on the Apnea-Hypopnea Index (AHI), with discrepancies arising from the 3% and 4% desaturation criteria. This study investigates age-related variations in OSA severity classification, utilizing data from 1201 adult patients undergoing Home Sleep Apnea Testing (HSAT) with SleepImage Ring@. METHODS: The study employs Bland-Altman analysis to compare AHI values obtained with the 3% and 4% desaturation criteria. Age-stratified analysis explores discrepancies across different age groups. RESULTS: The analysis reveals a systematic bias favoring the 3% criterion, impacting the quantification of apnea events. Age-specific patterns demonstrate diminishing agreement between criteria with increasing age. CONCLUSION: This comprehensive study underscores the importance of standardized criteria in OSA diagnosis. The findings emphasize age-specific considerations and ethical concerns, providing crucial insights for optimizing patient care and advancing sleep medicine practices.


Assuntos
Polissonografia , Apneia Obstrutiva do Sono , Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Apneia Obstrutiva do Sono/diagnóstico , Polissonografia/instrumentação , Polissonografia/métodos , Adulto , Fatores Etários , Idoso , Índice de Gravidade de Doença
10.
Genet Test Mol Biomarkers ; 28(4): 159-164, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38657123

RESUMO

Introduction: Sleep is one of the most significant parts of everyone's life. Most people sleep for about one-third of their lives. Sleep disorders negatively impact the quality of life. Obstructive sleep apnea (OSA) is a severe sleep disorder that significantly impacts the patient's life and their family members. This study aimed to investigate the relationship between rs6313 and rs6311 polymorphisms in the serotonin receptor type 2A gene and OSA in the Kurdish population. Materials and Methods: The study's population comprises 100 OSA sufferers and 100 healthy people. Polysomnography diagnostic tests were done on both the patient and control groups. The polymerase chain reaction (PCR)-restriction fragment length polymorphism (RFLP) was used to investigate the relationship between OSA and LEPR gene polymorphisms. Results: Statistical analysis showed a significant relationship between genotype frequencies of patient and control groups of rs6311 with OSA in dominant [odds ratio (OR) = 5.203, p < 0.001) and codominant models (OR = 9.7, p < 0.001). Also, there was a significant relationship between genotype frequencies of patient and control groups of rs6313 with OSA in dominant (OR = 10.565, p < 0.001) and codominant models (OR = 5.938, p < 0.001). Conclusions: Findings from the study demonstrated that the two polymorphisms rs6311 and rs6313 could be effective at causing OSA; however, there was no correlation between the severity of the disease and either of the two polymorphisms.


Assuntos
Frequência do Gene , Predisposição Genética para Doença , Polimorfismo de Nucleotídeo Único , Receptor 5-HT2A de Serotonina , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/genética , Irã (Geográfico) , Masculino , Feminino , Adulto , Pessoa de Meia-Idade , Receptor 5-HT2A de Serotonina/genética , Polimorfismo de Nucleotídeo Único/genética , Frequência do Gene/genética , Estudos de Casos e Controles , Genótipo , Polissonografia/métodos , Alelos , Polimorfismo de Fragmento de Restrição , Receptores para Leptina/genética , Estudos de Associação Genética/métodos
11.
Artigo em Inglês | MEDLINE | ID: mdl-38635384

RESUMO

Polysomnography (PSG) recordings have been widely used for sleep staging in clinics, containing multiple modality signals (i.e., EEG and EOG). Recently, many studies have combined EEG and EOG modalities for sleep staging, since they are the most and the second most powerful modality for sleep staging among PSG recordings, respectively. However, EEG is complex to collect and sensitive to environment noise or other body activities, imbedding its use in clinical practice. Comparatively, EOG is much more easily to be obtained. In order to make full use of the powerful ability of EEG and the easy collection of EOG, we propose a novel framework to simplify multimodal sleep staging with a single EOG modality. It still performs well with only EOG modality in the absence of the EEG. Specifically, we first model the correlation between EEG and EOG, and then based on the correlation we generate multimodal features with time and frequency guided generators by adopting the idea of generative adversarial learning. We collected a real-world sleep dataset containing 67 recordings and used other four public datasets for evaluation. Compared with other existing sleep staging methods, our framework performs the best when solely using the EOG modality. Moreover, under our framework, EOG provides a comparable performance to EEG.


Assuntos
Algoritmos , Eletroencefalografia , Eletroculografia , Polissonografia , Fases do Sono , Humanos , Eletroencefalografia/métodos , Fases do Sono/fisiologia , Polissonografia/métodos , Eletroculografia/métodos , Masculino , Adulto , Feminino , Adulto Jovem
12.
Eur Arch Otorhinolaryngol ; 281(6): 3107-3113, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38573510

RESUMO

PURPOSE: This study aimed to investigate the role of nap polysomnography (NPSG) in predicting treatment strategies for infants with moderate to severe laryngomalacia and to explore the association between obstructive sleep apnea (OSA) severity, weight gain, and laryngomalacia severity. METHODS: A retrospective analysis was conducted on infants diagnosed with moderate to severe laryngomalacia who underwent NPSG between January 2019 and June 2023. Clinical variables, NPSG parameters, and treatment decisions were collected. Weight gain rate and its correlation with NPSG indices were assessed. Logistic regression analyses were performed to predict treatment strategies based on NPSG findings. RESULTS: Of the 39 infants included (median age: 3.3 months), 77% exhibited OSA, with 69% having moderate to severe OSA [apnea-hypopnea index (AHI) > 5/h]. Weight gain rate correlated negatively with indices of OSA severity, including the hypopnea index (HI) and the AHI. In a multiple logistic regression analysis incorporating the severity of OSA (AHI), weight gain rate, and laryngomalacia severity, only AHI predicted the decision for surgical or non-invasive ventilation treatment (OR = 2.1, CI95 [1.6; 2.8], p ≤ 10-4). The weight gain rate was predicted (r2 = 0.28) by the AHI and the presence of retractions of auxiliary inspiratory muscles. CONCLUSION: This study underscores the importance of NPSG in assessing infants with moderate to severe laryngomalacia. The AHI from NPSG emerged as a potential predictor for treatment decisions and weight gain rate, emphasizing its clinical relevance. These findings advocate incorporating NPSG into the diagnostic and management process for infants with laryngomalacia.


Assuntos
Laringomalácia , Polissonografia , Apneia Obstrutiva do Sono , Humanos , Laringomalácia/complicações , Laringomalácia/diagnóstico , Estudos Retrospectivos , Polissonografia/métodos , Masculino , Lactente , Feminino , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/diagnóstico , Apneia Obstrutiva do Sono/fisiopatologia , Índice de Gravidade de Doença , Aumento de Peso
13.
Sci Rep ; 14(1): 9859, 2024 04 29.
Artigo em Inglês | MEDLINE | ID: mdl-38684765

RESUMO

Numerous models for sleep stage scoring utilizing single-channel raw EEG signal have typically employed CNN and BiLSTM architectures. While these models, incorporating temporal information for sequence classification, demonstrate superior overall performance, they often exhibit low per-class performance for N1-stage, necessitating an adjustment of loss function. However, the efficacy of such adjustment is constrained by the training process. In this study, a pioneering training approach called separating training is introduced, alongside a novel model, to enhance performance. The developed model comprises 15 CNN models with varying loss function weights for feature extraction and 1 BiLSTM for sequence classification. Due to its architecture, this model cannot be trained using an end-to-end approach, necessitating separate training for each component using the Sleep-EDF dataset. Achieving an overall accuracy of 87.02%, MF1 of 82.09%, Kappa of 0.8221, and per-class F1-socres (W 90.34%, N1 54.23%, N2 89.53%, N3 88.96%, and REM 87.40%), our model demonstrates promising performance. Comparison with sleep technicians reveals a Kappa of 0.7015, indicating alignment with reference sleep stags. Additionally, cross-dataset validation and adaptation through training with the SHHS dataset yield an overall accuracy of 84.40%, MF1 of 74.96% and Kappa of 0.7785 when tested with the Sleep-EDF-13 dataset. These findings underscore the generalization potential in model architecture design facilitated by our novel training approach.


Assuntos
Aprendizado Profundo , Eletroencefalografia , Fases do Sono , Humanos , Eletroencefalografia/métodos , Fases do Sono/fisiologia , Masculino , Adulto , Feminino , Polissonografia/métodos , Adulto Jovem , Redes Neurais de Computação
14.
J Clin Sleep Med ; 20(3): 353-361, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38426847

RESUMO

STUDY OBJECTIVES: To prospectively validate drug-induced sleep endoscopy with mandibular advancement maneuvers as a prediction tool for treatment success of oral appliance treatment (OAT). METHODS: Seventy-seven patients diagnosed with moderate obstructive sleep apnea were included and underwent drug-induced sleep endoscopy. The upper airway collapse was assessed using the VOTE classification. Additionally, three mandibular advancement maneuvers were performed to predict treatment success of OAT. If the maneuver was negative, the level and degree and configuration of the persistent collapse was described according to the VOTE classification. All patients were treated with OAT and completed a follow-up sleep study with OAT in situ without regard to their anticipated response to treatment. RESULTS: Sixty-four patients completed 6-month follow up. A positive jaw thrust maneuver proved to be significantly associated with favorable OAT response, whereas the chin lift maneuver and the vertical chin lift maneuver were not. Additionally, a persistent lateral oropharyngeal collapse when performing any mandibular advancement maneuver was significantly associated with unfavorable OAT response. CONCLUSIONS: The current findings suggest that a jaw thrust maneuver should be preferred over the chin lift maneuver for predicting OAT response. Patients with a positive jaw thrust maneuver should be counseled toward favorable OAT response, whereas those with persistent lateral oropharyngeal collapse should be advised about the likelihood of unfavorable OAT response. A negative jaw thrust maneuver did not prove to be a significant predictor for unfavorable response to OAT. Consequently, uncertainties arise regarding the justification of performing drug-induced sleep endoscopy solely for predicting the efficacy of OAT. However, the results of the current study could be influenced by heterogeneity in the assessment of respiratory parameters, variability in the performance of the mandibular advancement maneuvers, and the instability of bolus technique sedation. CLINICAL TRIAL REGISTRATION: Registry: Netherlands Trial Register; Name: Drug-induced Sleep Endoscopy: a prediction tool for success rate of oral appliance treatment; Identifier: NL8425; URL: https://www.onderzoekmetmensen.nl/en/trial/20741. CITATION: Veugen CCAFM, Kant E, Kelder JC, Schipper A, Stokroos RJ, Copper MP. The predictive value of mandibular advancement maneuvers during drug-induced sleep endoscopy for treatment success of oral appliance treatment in obstructive sleep apnea: a prospective study. J Clin Sleep Med. 2024;20(3): 353-361.


Assuntos
Avanço Mandibular , Apneia Obstrutiva do Sono , Humanos , Endoscopia/métodos , Polissonografia/métodos , Estudos Prospectivos , Sono , Apneia Obstrutiva do Sono/diagnóstico , Resultado do Tratamento
15.
Ann Biomed Eng ; 52(6): 1463-1491, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38493234

RESUMO

In recent years, research on automated sleep analysis has witnessed significant growth, reflecting advancements in understanding sleep patterns and their impact on overall health. This review synthesizes findings from an exhaustive analysis of 87 papers, systematically retrieved from prominent databases such as Google Scholar, PubMed, IEEE Xplore, and ScienceDirect. The selection criteria prioritized studies focusing on methods employed, signal modalities utilized, and machine learning algorithms applied in automated sleep analysis. The overarching goal was to critically evaluate the strengths and weaknesses of the proposed methods, shedding light on the current landscape and future directions in sleep research. An in-depth exploration of the reviewed literature revealed a diverse range of methodologies and machine learning approaches employed in automated sleep studies. Notably, K-Nearest Neighbors (KNN), Ensemble Learning Methods, and Support Vector Machine (SVM) emerged as versatile and potent classifiers, exhibiting high accuracies in various applications. However, challenges such as performance variability and computational demands were observed, necessitating judicious classifier selection based on dataset intricacies. In addition, the integration of traditional feature extraction methods with deep structures and the combination of different deep neural networks were identified as promising strategies to enhance diagnostic accuracy in sleep-related studies. The reviewed literature emphasized the need for adaptive classifiers, cross-modality integration, and collaborative efforts to drive the field toward more accurate, robust, and accessible sleep-related diagnostic solutions. This comprehensive review serves as a solid foundation for researchers and practitioners, providing an organized synthesis of the current state of knowledge in automated sleep analysis. By highlighting the strengths and challenges of various methodologies, this review aims to guide future research toward more effective and nuanced approaches to sleep diagnostics.


Assuntos
Sono , Humanos , Sono/fisiologia , Aprendizado de Máquina , Polissonografia/métodos , Eletroencefalografia , Processamento de Sinais Assistido por Computador , Máquina de Vetores de Suporte
16.
Comput Biol Med ; 173: 108314, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38513392

RESUMO

Sleep staging is a vital aspect of sleep assessment, serving as a critical tool for evaluating the quality of sleep and identifying sleep disorders. Manual sleep staging is a laborious process, while automatic sleep staging is seldom utilized in clinical practice due to issues related to the inadequate accuracy and interpretability of classification results in automatic sleep staging models. In this work, a hybrid intelligent model is presented for automatic sleep staging, which integrates data intelligence and knowledge intelligence, to attain a balance between accuracy, interpretability, and generalizability in the sleep stage classification. Specifically, it is built on any combination of typical electroencephalography (EEG) and electrooculography (EOG) channels, including a temporal fully convolutional network based on the U-Net architecture and a multi-task feature mapping structure. The experimental results show that, compared to current interpretable automatic sleep staging models, our model achieves a Macro-F1 score of 0.804 on the ISRUC dataset and 0.780 on the Sleep-EDFx dataset. Moreover, we use knowledge intelligence to address issues of excessive jumps and unreasonable sleep stage transitions in the coarse sleep graphs obtained by the model. We also explore the different ways knowledge intelligence affects coarse sleep graphs by combining different sleep graph correction methods. Our research can offer convenient support for sleep physicians, indicating its significant potential in improving the efficiency of clinical sleep staging.


Assuntos
Fases do Sono , Sono , Polissonografia/métodos , Eletroencefalografia/métodos , Eletroculografia/métodos
18.
Sci Rep ; 14(1): 6676, 2024 03 20.
Artigo em Inglês | MEDLINE | ID: mdl-38509240

RESUMO

Several studies have shown an association between albuminuria and obstructive sleep apnea (OSA). However, studies on the relationship between the STOP-BANG questionnaire that can screen for OSA and microalbuminuria are still insufficient. Therefore, this study attempted to clarify the relationship between microalbuminuria and OSA risk using the STOP-BANG questionnaire in Korean adults. A total of 7478 participants (3289 men and 4189 women) aged over 40 were enrolled in the Korean National Health and Nutrition Examination Survey from 2019 to 2020. STOP-BANG questionnaire to screen OSA was obtained from subjects. The urinary albumin/creatinine ratio (ACR) and proteinuria were measured via a single dipstick to evaluate renal function. The high OSA risk group had a higher mean ACR value than the low OSA risk group (36.8 ± 172.2 vs 17.7 ± 82.5; P < 0.001). The proportion of subjects with values of 30 ≤ ACR < 300 mg/g (11.9% vs 6.1%; P < 0.001) and ACR > 300 mg/g (2.1% vs 0.7%; P < 0.001) was significantly higher in high OSA risk group. Multivariate logistic regression results confirmed that microalbuminuria (OR 1.279, 95% confidence interval (CI) 1.068-1.532, P = 0.008) was significantly correlated with high OSA risk. In addition, significant correlation with high OSA risk was also found in macroalbuminuria (OR 1.684, 95% CI 1.073-2.530, P = 0.022) and proteinuria (OR 1.355, 95% CI 1.030-1.783, P = 0.030). We confirmed a significant correlation between high OSA risk and albuminuria/proteinuria in Korean adults. Therefore, renal function evaluation is required in high OSA risk patients, and OSA diagnosis through PSG test and treatment is necessary.


Assuntos
Albuminúria , Apneia Obstrutiva do Sono , Adulto , Masculino , Humanos , Feminino , Pessoa de Meia-Idade , Estudos Transversais , Albuminúria/complicações , Albuminúria/epidemiologia , Albuminúria/urina , Inquéritos Nutricionais , Polissonografia/métodos , Inquéritos e Questionários , Apneia Obstrutiva do Sono/complicações , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/diagnóstico , República da Coreia/epidemiologia
19.
Neurophysiol Clin ; 54(2): 102938, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38401239

RESUMO

Excessive daytime sleepiness (EDS) is multifactorial. It combines, among other things, an excessive propensity to fall asleep ("physiological sleepiness") and a continuous non-imperative sleepiness (or drowsiness/hypo-arousal) leading to difficulties remaining awake and maintaining sustained attention and vigilance over the long term ("manifest sleepiness"). There is no stand-alone biological measure of EDS. EDS measures can either capture the severity of physiological sleepiness, which corresponds to the propensity to fall asleep, or the severity of manifest sleepiness, which corresponds to behavioral consequences of sleepiness and reduced vigilance. Neuropsychological tests (The psychomotor vigilance task (PVT), Oxford Sleep Resistance Test (OSLeR), Sustained Attention to Response Task (SART)) explore manifest sleepiness through several sustained attention tests but the lack of normative values and standardized protocols make the results difficult to interpret and use in clinical practice. Neurophysiological tests explore the two main aspects of EDS, i.e. the propensity to fall asleep (Multiple sleep latency test, MSLT) and the capacity to remain awake (Maintenance of wakefulness test, MWT). The MSLT and the MWT are widely used in clinical practice. The MSLT is recognized as the "gold standard" test for measuring the severity of the propensity to fall asleep and it is a diagnostic criterion for narcolepsy. The MWT measures the ability to stay awake. The MWT is not a diagnostic test as it is recommended only to evaluate the evolution of EDS and efficacy of EDS treatment. Even if some efforts to standardize the protocols for administration of these tests have been ongoing, MSLT and MWT have numerous limitations: age effect, floor or ceiling effects, binding protocol, no normal or cutoff value (or determined in small samples), and no or low test-retest values in some pathologies. Moreover, the recommended electrophysiological set-up and the determination of sleep onset using the 30­sec epochs scoring rule show some limitations. New, more precise neurophysiological techniques should aim to detect very brief periods of physiological sleepiness and, in the future, the brain local phenomenon of sleepiness likely to underpin drowsiness, which could be called "physiological drowsiness".


Assuntos
Distúrbios do Sono por Sonolência Excessiva , Sonolência , Humanos , Distúrbios do Sono por Sonolência Excessiva/diagnóstico , Sono/fisiologia , Vigília/fisiologia , Polissonografia/métodos
20.
Sleep ; 47(4)2024 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-38300896

RESUMO

STUDY OBJECTIVES: The purpose of this study was to examine the degree of short-term stability of polysomnographic (PSG) measured sleep parameters and the overall differences between individuals with comorbid nightmares and insomnia compared to those with chronic insomnia disorder alone or good sleeping controls across four nights in the sleep lab. METHODS: A total of 142 good sleeping controls, 126 chronic insomnia alone, and 24 comorbid insomnia/nightmare participants underwent four consecutive nights of 8-hour PSG recordings. Outcomes included sleep continuity, architecture, and REM-related parameters across nights one through four. Intraclass correlation coefficients with mixed-effect variances and repeated-measure analysis of covariance were used, respectively, to determine short-term stability as well as between-participants and time-by-group interaction effects. RESULTS: Wake after sleep onset and stage 1 showed "poor stability" in the comorbid insomnia/nightmare group compared to "moderate stability" in the good sleeping controls and chronic insomnia alone group. Significant between-group effects (all ps < .05) showed that the comorbid insomnia/nightmare group took longer to fall asleep and had a greater first-night-effect in stage 1 compared to good sleeping controls and chronic insomnia alone group; in addition, the comorbid insomnia/nightmare and insomnia alone groups slept shorter, with fewer awakenings and REM periods, compared to the good sleeping controls. CONCLUSIONS: Nightmares are associated with abnormal sleep above and beyond REM disruption, as sleep continuity was the primary aspect in which poor stability and group differences emerged. The greater inability to fall asleep and instability of sleep fragmentation in those with comorbid insomnia/nightmares compared to chronic insomnia alone may be attributed to the impact of presleep anticipatory anxiety and nightmare-related distress itself. CLINICAL TRIAL INFORMATION: The data analyzed in this study does not come from any current or previous clinical trials. Therefore, there is no clinical trial information to report.


Assuntos
Distúrbios do Início e da Manutenção do Sono , Humanos , Distúrbios do Início e da Manutenção do Sono/complicações , Distúrbios do Início e da Manutenção do Sono/epidemiologia , Sonhos , Polissonografia/métodos , Sono , Ansiedade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA