Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 791
Filtrar
1.
Ann Am Thorac Soc ; 21(5): 814-822, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38330168

RESUMO

Rationale: Oral appliances are second-line treatments after continuous positive airway pressure for obstructive sleep apnea (OSA) management. However, the need for oral appliance titration limits their use as a result of monitoring challenges to assess the treatment effect on OSA. Objectives: To assess the validity of mandibular jaw movement (MJM) automated analysis compared with polysomnography (PSG) and polygraphy (PG) in evaluating the effect of oral appliance treatment and the effectiveness of MJM monitoring for oral appliance titration at home in patients with OSA. Methods: This observational, prospective study included 135 patients with OSA eligible for oral appliance therapy. The primary outcome was the apnea-hypopnea index (AHI), measured through in-laboratory PSG/PG and MJM-based technology. Additionally, MJM monitoring at home was conducted at regular intervals during the titration process. The agreement between PSG/PG and MJM automated analysis was revaluated using Bland-Altman analysis. Changes in AHI during the home-based oral appliance titration process were evaluated using a generalized linear mixed model and a generalized estimating equation model. Results: The automated MJM analysis demonstrated strong agreement with PG in assessing AHI at the end of titration, with a median bias of 0.24/h (limits of agreement, -11.2 to 12.8/h). The improvement of AHI from baseline in response to oral appliance treatment was consistent across three evaluation conditions: in-laboratory PG (-59.6%; 95% confidence interval, -59.8% to -59.5%), in-laboratory automated MJM analysis (-59.2%; -65.2% to -52.2%), and at-home automated MJM analysis (-59.7%; -67.4% to -50.2%). Conclusions: Incorporating MJM automated analysis into the oral appliance titration process has the potential to optimize oral appliance therapy outcomes for OSA.


Assuntos
Polissonografia , Apneia Obstrutiva do Sono , Humanos , Apneia Obstrutiva do Sono/terapia , Apneia Obstrutiva do Sono/diagnóstico , Estudos Prospectivos , Masculino , Feminino , Pessoa de Meia-Idade , Adulto , Mandíbula , Idoso , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Movimento , Monitorização Fisiológica/métodos , Monitorização Fisiológica/instrumentação
2.
Sleep Med ; 107: 157-163, 2023 07.
Artigo em Inglês | MEDLINE | ID: mdl-37178547

RESUMO

STUDY OBJECTIVES: Cheyne - Stokes respiration (CSR) is prevalent in patients with chronic heart failure (CHF). Adaptive Servo Ventilation (ASV) alleviates CSR and improves objective sleep quality. We investigated the effects of ASV on neurocognitive function in the symptomatic phenotype of patients with CSR and CHF. METHODS: This case series included patients diagnosed with stable CHF (NYHA ≥ II) and CSR (N = 8). Sleep and neurocognitive function were assessed at baseline and after 1- and 6-months following initiation of ASV treatment. RESULTS: In CHF patients (n = 8, median age 78.0[64.5-80.8] years and BMI 30.0[27.0-31.5] kg/m2, median ejection fraction 30[24-45]%, Epworth Sleepiness Scale (ESS) score 11.5[9.0-15.0]), ASV markedly improved respiration during sleep (Apnea-Hypopnea Index (AHI) 44.1[39.0-51.5]n/h at baseline, 6.3[2.4-9.7]n/h at 6 months treatment, respectively, p < 0.01). The 6-min-walk test distance increased by treatment from (295.0[178.8-385.0] m to 356.0[203.8-495.0] m (p = 0.05)). Sleep structure was modified, and Stage 3 increased markedly from 6.4[1.7-20.1] % to 20.8[14.2-25.3] %, p < 0.02). Sleep latency in the Maintenance of Wakefulness Test increased from 12.0[6.0-30.0] min to 26.3[12.0-30.0] min, (p = 0.04). In the Attention Network Test, evaluating neurocognition, the number of lapses decreased from 6.0[1.0-44.0] to 2.0[0.3-8.0], (p = 0.05) and the overall number of responses to a preset stimulus increased after treatment (p = 0.04). CONCLUSIONS: ASV treatment in CHF patients with CSR may improve sleep quality, neurocognition and daytime performance.


Assuntos
Respiração de Cheyne-Stokes , Cognição , Pressão Positiva Contínua nas Vias Aéreas , Distúrbios do Sono por Sonolência Excessiva , Insuficiência Cardíaca , Distúrbios do Sono por Sonolência Excessiva/complicações , Distúrbios do Sono por Sonolência Excessiva/psicologia , Distúrbios do Sono por Sonolência Excessiva/terapia , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/psicologia , Insuficiência Cardíaca/terapia , Doença Crônica , Respiração de Cheyne-Stokes/etiologia , Respiração de Cheyne-Stokes/psicologia , Respiração de Cheyne-Stokes/terapia , Humanos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Projetos Piloto
4.
PLoS Negl Trop Dis ; 16(3): e0010221, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35239650

RESUMO

Low-cost improvised continuous positive airway pressure (CPAP) device is safe and efficacious in neonatal respiratory distress. There is a great necessity for similar device in adults, and this has been especially made apparent by the recent Coronavirus Disease 2019 (COVID-19) pandemic, which is unmasking the deficiencies of healthcare system in several low-resource countries. We propose a simplified and inexpensive model of improvised CPAP in adults using locally available resources including aquarium air pumps and a novel pressure release mechanism. Although the safety and efficacy of improvised CPAP in adults are not established, the conceptual model we propose has the potential to serve as a lifesaving technology in many low-resource settings during this ongoing pandemic and thus calls for expedited research.


Assuntos
COVID-19/terapia , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Desenho de Equipamento/economia , Terapia Respiratória/instrumentação , Adulto , Humanos , Ventilação não Invasiva/instrumentação , SARS-CoV-2
5.
Schizophr Bull ; 48(2): 437-446, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34581411

RESUMO

Obstructive sleep apnea (OSA) is a highly prevalent condition in people living with schizophrenia or other psychotic disorder. Its treatment with continuous positive airway pressure therapy (CPAP) can dramatically improve daytime and physical health function. People with a psychotic disorder, however, are rarely diagnosed and treated and there are no large-scale studies showing evidence of successful treatment with CPAP. Using a retrospective case-control study approach (N = 554), we examined adherence to and effectiveness of a CPAP trial in individuals with comorbid psychotic disorder and OSA (psychosis group, n = 165) referred for a CPAP trial at the West Australian Sleep Disorders Research Institute. Given that antipsychotic medication is an important confounder, we included a psychiatric (non-psychosis) comparison group taking antipsychotic medication (antipsychotic group, n = 82), as well as a nonpsychiatric control group (OSA control group, n = 307) also diagnosed with OSA and referred for CPAP. Variables included OSA symptom response, CPAP engagement, and usage at 3 months. The Psychosis group had the most severe OSA at baseline and they attended fewer clinic appointments overall. However, there were no other group differences either in CPAP adherence or treatment response. CPAP was equally effective in normalizing OSA symptoms and daytime sleepiness in all groups. CPAP usage was longer per night in the Psychosis and Antipsychotic groups, perhaps suggesting a role of sedation from antipsychotic medications. In conclusion, OSA is treatable and CPAP feasible in people with severe mental illness and antipsychotic medications are not a barrier to treatment response.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/métodos , Apneia Obstrutiva do Sono/terapia , Adulto , Idoso , Idoso de 80 Anos ou mais , Análise de Variância , Estudos de Casos e Controles , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Esquizofrenia/epidemiologia , Esquizofrenia/terapia , Apneia Obstrutiva do Sono/epidemiologia , Apneia Obstrutiva do Sono/fisiopatologia , Austrália Ocidental/epidemiologia
6.
Sci Rep ; 11(1): 23527, 2021 12 07.
Artigo em Inglês | MEDLINE | ID: mdl-34876630

RESUMO

Nasal continuous positive airway pressure (nCPAP) is the standard non-invasive respiratory support for newborns with respiratory distress. Nasal injury is a common problem with the interfaces used. To compare the incidence and severity of nasal injury in neonates with respiratory distress and supported on nCPAP with Hudson prong or RAM cannula with Cannulaide, a semipermeable membrane. This is an open-label, parallel-arm, gestational age-stratified, bi-centric, randomized control trial including neonates between 28 and 34 weeks gestational age and birth weight > 1000 g needing nCPAP. The size of the interface was chosen as per the manufacturer's recommendation. Of the 229 neonates enrolled, 112 were randomized to RAM cannula with Cannulaide and 117 to Hudson prong. The baseline characteristics were similar. Any nasal injury at CPAP removal was significantly lower in the RAM cannula with Cannulaide group [6 (5.4%) vs. 31 (26.4%); risk ratio-0.77 (95% CI 0.69-0.87); p = 0.0001]. The incidence of moderate to severe nasal injury, need for mechanical ventilation within 72 h of age, duration of oxygen, and requirement of nCPAP for > 3 days were similar. For preterm infants on nCPAP, RAM cannula with Cannulaide, compared to Hudson prongs, decreases nasal injury without increasing the need for mechanical ventilation.Trail registration: CTRI/2019/03/018333, http://www.ctri.nic.in .


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Cânula , Feminino , Idade Gestacional , Humanos , Incidência , Recém-Nascido , Recém-Nascido Prematuro , Masculino , Nariz/fisiopatologia , Respiração Artificial/instrumentação , Respiração Artificial/métodos , Desmame do Respirador/métodos
7.
Chest ; 160(5): e419-e425, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339687

RESUMO

This document summarizes suggestions of the central sleep apnea (CSA) Technical Expert Panel working group. This paper shares our vision for bringing the right device to the right patient at the right time. For patients with CSA, current coverage criteria do not align with guideline treatment recommendations. For example, CPAP and oxygen therapy are recommended but not covered for CSA. On the other hand, bilevel positive airway pressure (BPAP) without a backup rate may be a covered therapy for OSA, but it may worsen CSA. Narrow coverage criteria that require near elimination of obstructive breathing events on CPAP or BPAP in the spontaneous mode, even if at poorly tolerated pressure levels, may preclude therapy with BPAP with backup rate or adaptive servoventilation, even when those devices provide demonstrably better therapy. CSA is a dynamic disorder that may require different treatments over time, sometimes switching from one device to another; an example is switching from BPAP with backup rate to an adaptive servoventilation with automatic end-expiratory pressure adjustments, which may not be covered. To address these challenges, we suggest several changes to the coverage determinations, including: (1) a single simplified initial and continuing coverage definition of CSA that aligns with OSA; (2) removal of hypoventilation terminology from coverage criteria for CSA; (3) all effective therapies for CSA should be covered, including oxygen and all PAP devices with or without backup rates or servo-mechanisms; and (4) patients shown to have a suboptimal response to one PAP device should be allowed to add oxygen or change to another PAP device with different capabilities if shown to be effective with testing.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Hipóxia , Medicare , Ventilação não Invasiva , Oxigenoterapia , Apneia do Sono Tipo Central , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Humanos , Hipóxia/diagnóstico , Hipóxia/etiologia , Hipóxia/fisiopatologia , Hipóxia/terapia , Medicare/organização & administração , Medicare/normas , Ventilação não Invasiva/instrumentação , Ventilação não Invasiva/métodos , Oxigenoterapia/instrumentação , Oxigenoterapia/métodos , Seleção de Pacientes , Apneia do Sono Tipo Central/complicações , Apneia do Sono Tipo Central/fisiopatologia , Apneia do Sono Tipo Central/terapia , Tempo para o Tratamento , Estados Unidos
8.
Chest ; 160(5): e399-e408, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34339688

RESUMO

The existing coverage criteria for noninvasive ventilation (NIV) do not recognize the benefits of early initiation of NIV for those with thoracic restrictive disorders and do not address the unique needs for daytime support as the patients progress to ventilator dependence. This document summarizes the work of the thoracic restrictive disorder Technical Expert Panel working group. The most pressing current coverage barriers identified were: (1) delays in implementing NIV treatment; (2) lack of coverage for many nonprogressive neuromuscular diseases; and (3) lack of clear policy indications for home mechanical ventilation (HMV) support in thoracic restrictive disorders. To best address these issues, we make the following key recommendations: (1) given the need to encourage early initiation of NIV with bilevel positive airway pressure devices, we recommend that symptoms be considered as a reason to initiate therapy even at mildly reduced FVCs; (2) broaden CO2 measurements to include surrogates such as transcutaneous, end-tidal, or venous blood gas; (3) expand the diagnostic category to include phrenic nerve injuries and disorders of central drive; (4) allow a bilevel positive airway pressure device to be advanced to an HMV when the vital capacity is < 30% or to address severe daytime respiratory symptoms; and (5) provide additional HMV when the patient is ventilator dependent with use > 18 h per day. Adoption of these proposed recommendations would result in the right device, at the right time, for the right type of patients with thoracic restrictive disorders.


Assuntos
Serviços de Assistência Domiciliar , Medicare , Doenças Neuromusculares , Ventilação não Invasiva , Insuficiência Respiratória , Doenças Torácicas , Gasometria/métodos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Serviços de Assistência Domiciliar/organização & administração , Serviços de Assistência Domiciliar/normas , Humanos , Medicare/organização & administração , Medicare/normas , Doenças Neuromusculares/complicações , Doenças Neuromusculares/diagnóstico , Doenças Neuromusculares/fisiopatologia , Ventilação não Invasiva/instrumentação , Ventilação não Invasiva/métodos , Seleção de Pacientes , Insuficiência Respiratória/sangue , Insuficiência Respiratória/etiologia , Insuficiência Respiratória/terapia , Doenças Torácicas/complicações , Doenças Torácicas/diagnóstico , Estados Unidos
10.
Am J Emerg Med ; 49: 385-392, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34271286

RESUMO

STUDY OBJECTIVE: To determine whether non-invasive ventilation (NIV) delivered by helmet continuous positive airway pressure (hCPAP) is non-inferior to facemask continuous positive airway pressure (fCPAP) in patients with acute respiratory failure in the emergency department (ED). METHODS: Non-inferiority randomized, clinical trial involving patients presenting with acute respiratory failure conducted in the ED of a local hospital. Participants were randomly allocated to receive either hCPAP or fCPAP as per the trial protocol. The primary endpoint was respiratory rate reduction. Secondary endpoints included discomfort, improvement in Dyspnea and Likert scales, heart rate reduction, arterial blood oxygenation, partial pressure of carbon dioxide (PaCO2), dryness of mucosa and intubation rate. RESULTS: 224 patients were included and randomized (113 patients to hCPAP, 111 to fCPAP). Both techniques reduced respiratory rate (hCPAP: from 33.56 ± 3.07 to 25.43 ± 3.11 bpm and fCPAP: from 33.46 ± 3.35 to 27.01 ± 3.19 bpm), heart rate (hCPAP: from 114.76 ± 15.5 to 96.17 ± 16.50 bpm and fCPAP: from 115.07 ± 14.13 to 101.19 ± 16.92 bpm), and improved dyspnea measured by both the Visual Analogue Scale (hCPAP: from 16.36 ± 12.13 to 83.72 ± 12.91 and fCPAP: from 16.01 ± 11.76 to 76.62 ± 13.91) and the Likert scale. Both CPAP techniques improved arterial oxygenation (PaO2 from 67.72 ± 8.06 mmHg to 166.38 ± 30.17 mmHg in hCPAP and 68.99 ± 7.68 mmHg to 184.49 ± 36.38 mmHg in fCPAP) and the PaO2:FiO2 (Partial pressure of arterial oxygen: Fraction of inspired oxygen) ratio from 113.6 ± 13.4 to 273.4 ± 49.5 in hCPAP and 115.0 ± 12.9 to 307.7 ± 60.9 in fCPAP. The intubation rate was lower with hCPAP (4.4% for hCPAP versus 18% for fCPAP, absolute difference -13.6%, p = 0.003). Discomfort and dryness of mucosa were also lower with hCPAP. CONCLUSION: In patients presenting to the ED with acute cardiogenic pulmonary edema or decompensated COPD, hCPAP was non-inferior to fCPAP and resulted in greater comfort levels and lower intubation rate.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Dispositivos de Proteção da Cabeça/normas , Máscaras/normas , Insuficiência Respiratória/terapia , Idoso , Pressão Positiva Contínua nas Vias Aéreas/normas , Pressão Positiva Contínua nas Vias Aéreas/estatística & dados numéricos , Serviço Hospitalar de Emergência/organização & administração , Serviço Hospitalar de Emergência/estatística & dados numéricos , Feminino , Dispositivos de Proteção da Cabeça/estatística & dados numéricos , Humanos , Masculino , Máscaras/estatística & dados numéricos , Pessoa de Meia-Idade , Ventilação não Invasiva/instrumentação , Ventilação não Invasiva/métodos
13.
Arch Dis Child Fetal Neonatal Ed ; 106(6): 663-667, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33963004

RESUMO

OBJECTIVE: To determine leakage for two neonatal continuous positive airway pressure (CPAP) interfaces and evaluate leak-corrective manoeuvres. DESIGN: The ToNIL (Trial of NCPAP Interface Leakage) study was a randomised, clinical, cross-over trial with data collection between August 2018 and October 2019. The primary outcome was blinded to the treating staff. SETTING: One secondary, 8-bed neonatal intensive care unit (NICU) and three larger (>15 beds), academic NICU referral centres. PATIENTS: Newborn infants with CPAP were screened (n=73), and those with stable spontaneous breathing, low oxygen requirement, postmenstrual age (PMA) over 28 weeks and no comorbidities were eligible. In total, 50 infants were included (median PMA 33 completed weeks). INTERVENTIONS: Leakage was measured for both prongs and nasal mask, before and after leak-corrective manoeuvres. Interface application was performed in a randomised order by a nurse, blinded to the measured leakage. MAIN OUTCOME MEASURES: 30 s average leakage, measured in litres per minute (LPM). RESULTS: Analyses showed a significantly lower leakage (mean difference 0.86 LPM, 95% CI 0.07 to 1.65) with prongs (median 2.01 LPM, IQR 1.00-2.80) than nasal mask (median 2.45 LPM, IQR 0.99-5.11). Leak-corrective manoeuvres reduced leakage significantly for both prongs (median 1.22 LPM, IQR 0.54-1.87) and nasal mask (median 2.35 LPM, IQR 0.76-4.75). CONCLUSIONS: Large leakages were common for both interfaces, less with prongs. Simple care manoeuvres reduced leakage for both interfaces. This is the first report of absolute leakage for nasal interfaces and should encourage further studies on leakage during CPAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas , Falha de Equipamento/estatística & dados numéricos , Cuidado do Lactente , Máscaras , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Estudos Cross-Over , Feminino , Idade Gestacional , Humanos , Cuidado do Lactente/instrumentação , Cuidado do Lactente/métodos , Recém-Nascido , Recém-Nascido Prematuro , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Masculino , Máscaras/efeitos adversos , Máscaras/classificação , Máscaras/normas , Avaliação de Processos e Resultados em Cuidados de Saúde , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia
14.
Chest ; 160(1): 175-186, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-33667491

RESUMO

BACKGROUND: SARS-CoV-2 aerosolization during noninvasive positive-pressure ventilation may endanger health care professionals. Various circuit setups have been described to reduce virus aerosolization. However, these setups may alter ventilator performance. RESEARCH QUESTION: What are the consequences of the various suggested circuit setups on ventilator efficacy during CPAP and noninvasive ventilation (NIV)? STUDY DESIGN AND METHODS: Eight circuit setups were evaluated on a bench test model that consisted of a three-dimensional printed head and an artificial lung. Setups included a dual-limb circuit with an oronasal mask, a dual-limb circuit with a helmet interface, a single-limb circuit with a passive exhalation valve, three single-limb circuits with custom-made additional leaks, and two single-limb circuits with active exhalation valves. All setups were evaluated during NIV and CPAP. The following variables were recorded: the inspiratory flow preceding triggering of the ventilator, the inspiratory effort required to trigger the ventilator, the triggering delay, the maximal inspiratory pressure delivered by the ventilator, the tidal volume generated to the artificial lung, the total work of breathing, and the pressure-time product needed to trigger the ventilator. RESULTS: With NIV, the type of circuit setup had a significant impact on inspiratory flow preceding triggering of the ventilator (P < .0001), the inspiratory effort required to trigger the ventilator (P < .0001), the triggering delay (P < .0001), the maximal inspiratory pressure (P < .0001), the tidal volume (P = .0008), the work of breathing (P < .0001), and the pressure-time product needed to trigger the ventilator (P < .0001). Similar differences and consequences were seen with CPAP as well as with the addition of bacterial filters. Best performance was achieved with a dual-limb circuit with an oronasal mask. Worst performance was achieved with a dual-limb circuit with a helmet interface. INTERPRETATION: Ventilator performance is significantly impacted by the circuit setup. A dual-limb circuit with oronasal mask should be used preferentially.


Assuntos
COVID-19 , Pressão Positiva Contínua nas Vias Aéreas , Transmissão de Doença Infecciosa/prevenção & controle , Ventilação não Invasiva , Filtros de Ar , Benchmarking/métodos , COVID-19/terapia , COVID-19/transmissão , Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Pressão Positiva Contínua nas Vias Aéreas/métodos , Procedimentos Clínicos/normas , Procedimentos Clínicos/tendências , Humanos , Transmissão de Doença Infecciosa do Paciente para o Profissional/prevenção & controle , Ventilação não Invasiva/efeitos adversos , Ventilação não Invasiva/instrumentação , Ventilação não Invasiva/métodos , Projetos de Pesquisa , Testes de Função Respiratória/métodos , SARS-CoV-2 , Resultado do Tratamento , Ventiladores Mecânicos
15.
Sci Rep ; 11(1): 5559, 2021 03 10.
Artigo em Inglês | MEDLINE | ID: mdl-33692464

RESUMO

During the COVID-19 pandemic, the need for noninvasive respiratory support devices has dramatically increased, sometimes exceeding hospital capacity. The full-face Decathlon snorkeling mask, EasyBreath (EB mask), has been adapted to deliver continuous positive airway pressure (CPAP) as an emergency respiratory interface. We aimed to assess the performance of this modified EB mask and to test its use during different gas mixture supplies. CPAP set at 5, 10, and 15 cmH2O was delivered to 10 healthy volunteers with a high-flow system generator set at 40, 80, and 120 L min-1 and with a turbine-driven ventilator during both spontaneous and loaded (resistor) breathing. Inspiratory CO2 partial pressure (PiCO2), pressure inside the mask, breathing pattern and electrical activity of the diaphragm (EAdi) were measured at all combinations of CPAP/flows delivered, with and without the resistor. Using the high-flow generator set at 40 L min-1, the PiCO2 significantly increased and the system was unable to maintain the target CPAP of 10 and 15 cmH2O and a stable pressure within the respiratory cycle; conversely, the turbine-driven ventilator did. EAdi significantly increased with flow rates of 40 and 80 L min-1 but not at 120 L min-1 and with the turbine-driven ventilator. EB mask can be safely used to deliver CPAP only under strict constraints, using either a high-flow generator at a flow rate greater than 80 L min-1, or a high-performance turbine-driven ventilator.


Assuntos
COVID-19/terapia , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Respiração Artificial/instrumentação , Adulto , Pressão Positiva Contínua nas Vias Aéreas/métodos , Mergulho , Feminino , Voluntários Saudáveis , Humanos , Masculino , Máscaras , Pandemias , Respiração , Respiração Artificial/métodos , SARS-CoV-2/patogenicidade , Ventiladores Mecânicos
16.
Pulmonology ; 27(5): 413-422, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33583765

RESUMO

Helmet CPAP (H-CPAP) has been recommended in many guidelines as a noninvasive respiratory support during COVID-19 pandemic in many countries around the world. It has the least amount of particle dispersion and air contamination among all noninvasive devices and may mitigate the ICU bed shortage during a COVID surge as well as a decreased need for intubation/mechanical ventilation. It can be attached to many oxygen delivery sources. The MaxVenturi setup is preferred as it allows for natural humidification, low noise burden, and easy transition to HFNC during breaks and it is the recommended transport set-up. The patients can safely be proned with the helmet. It can also be used to wean the patients from invasive mechanical ventilation. Our article reviews in depth the pathophysiology of COVID-19 ARDS, provides rationale of using H-CPAP, suggests a respiratory failure algorithm, guides through its setup and discusses the issues and concerns around using it.


Assuntos
COVID-19/terapia , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Ventilação não Invasiva/instrumentação , Insuficiência Respiratória/terapia , Desmame do Respirador/métodos , COVID-19/diagnóstico , COVID-19/fisiopatologia , COVID-19/transmissão , Dispositivos de Proteção da Cabeça , Humanos , Ventilação não Invasiva/métodos , Oxigenoterapia/instrumentação , Oxigenoterapia/métodos , Insuficiência Respiratória/diagnóstico , Insuficiência Respiratória/enfermagem , SARS-CoV-2/genética , SARS-CoV-2/isolamento & purificação
18.
Respir Res ; 22(1): 17, 2021 Jan 15.
Artigo em Inglês | MEDLINE | ID: mdl-33451313

RESUMO

BACKGROUND: For some patients, Continuous Positive Airway Pressure (CPAP) remains an uncomfortable therapy despite the constant development of technological innovations. To date, no real life study has investigated the relationship between mask related side-effects (MRSEs) and CPAP-non-adherence (defined as < 4 h/day) or residual-excessive-sleepiness (RES, Epworth-Sleepiness-Scale (ESS) score ≥ 11) in the long-term. METHODS: The InterfaceVent-CPAP study is a prospective real-life cross-sectional study conducted in an apneic adult cohort undergoing at least 3 months of CPAP with unrestricted mask-access (34 different masks). MRSEs were evaluated using visual-analogue-scales, CPAP-data using CPAP-software, sleepiness using ESS. RESULTS: 1484 patients were included in the analysis (72.2% male, median age 67 years (IQ25-75: 60-74), initial Apnea-Hypopnea-Index (AHI) of 39 (31-56)/h, residual AHIflow was 1.9 (0.9-4) events/h), CPAP-treatment lasted 4.4 (2.0-9.7) years, CPAP-usage was 6.8 (5.5-7.8) h/day, the prevalence of CPAP-non-adherence was 8.6%, and the prevalence of RES was 16.17%. Leak-related side-effects were the most prevalent side-effects (patient-reported leaks concerned 75.4% of responders and had no correlation with CPAP-reported-leaks). Multivariable logistic regression analyses evaluating explanatory-variable (demographic data, device/mask data and MRSEs) effects on variables-of-interest (CPAP-non-adherence and RES), indicated for patient-MRSEs significant associations between: (i) CPAP-non-adherence and dry-mouth (p = 0.004); (ii) RES and patient-reported leaks (p = 0.007), noisy mask (p < 0.001), dry nose (p < 0.001) and harness pain (p = 0.043). CONCLUSION: In long-term CPAP-treated patients, leak-related side-effects remain the most prevalent side-effects, but patient-reported leaks cannot be predicted by CPAP-reported-leaks. Patient-MRSEs can be independently associated with CPAP-non-adherence and RES, thus implying a complementary role for MRSE questionnaires alongside CPAP-device-reported-data for patient monitoring. Trial registration InterfaceVent is registered with ClinicalTrials.gov (NCT03013283).


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/efeitos adversos , Pressão Positiva Contínua nas Vias Aéreas/tendências , Apneia Obstrutiva do Sono/terapia , Sonolência , Idoso , Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Estudos Transversais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Apneia Obstrutiva do Sono/fisiopatologia
19.
Arch Dis Child Fetal Neonatal Ed ; 106(4): 404-407, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-33452219

RESUMO

OBJECTIVE: Patient's work of breathing may vary between different neonatal nasal continuous positive airway pressure (NCPAP) devices. Therefore, we aimed to compare the inspiratory effort of three variable-flow NCPAP delivery systems used in preterm infants. DESIGN: Cross-over study. PATIENTS/SETTING: From June 2015 to August 2016, 20 preterm infants weighing ≤2500 g requiring NCPAP for mild respiratory distress syndrome were enrolled. INTERVENTIONS: Each patient was successively supported by three randomly assigned variable-flow NCPAP systems (MedinCNO, Infant Flow and Servo-i) for 20 min while maintaining the same continuous positive airway pressure level as the patient was on before the study period. MAIN OUTCOME MEASURES: Patients' inspiratory effort was estimated by calculating the sum of the difference between maximal inspiratory and baseline electrical activity of the diaphragm (∆EAdi) for 30 consecutive breaths, and after normalising this obtained value for the timing of the 30 breaths. RESULTS: Physiological parameters (oxygen saturation measured by pulse oximetry, respiratory rate, heart beat, transcutaneous partial pressure CO2) and oxygen requirements remained identical between the three NCPAP systems. Although a wide variability in inspiratory effort could be observed, there were no statistically significant differences between the three systems for the sum of ∆EAdi for 30 breaths: CNO, 262 (±119) µV; IF, 352 (±262) µV; and SERVO-i, 286 (±126) µV, and the ∆EAdi reported on the timing of 30 breaths (sum ∆EAdi/s): CNO, 6.1 (±2.3) µV/s; IF, 7.9 (±4.9) µV/s; SERVO-i, 7.6 (±3.6) µV/s. CONCLUSION: In a neonatal population of preterm infants, inspiratory effort is comparable between the three tested modern variable-flow NCPAP devices.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Recém-Nascido Prematuro/fisiologia , Síndrome do Desconforto Respiratório do Recém-Nascido/terapia , Índice de Apgar , Estudos Cross-Over , Diafragma/fisiologia , Feminino , Frequência Cardíaca , Humanos , Recém-Nascido de Baixo Peso , Recém-Nascido , Masculino , Oximetria , Oxigênio/sangue , Taxa Respiratória
20.
Sleep Breath ; 25(3): 1477-1485, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33398794

RESUMO

PURPOSE: Positive airway pressure (PAP) devices have been widely used as the first line of treatment in obstructive sleep apnea (OSA). Most advanced PAP devices support the estimation of respiratory index (RI) using the patient's mask airflow. In addition to the compliance factor for PAP device use, which is important for monitoring patient sleep health, RI is also becoming important for monitoring. However, there are few reports that validate RI of a PAP device with polysomnography. METHODS: Between January 2015 and December 2017, 50 participants were enrolled who were diagnosed with OSA and prescribed auto-titration PAP (APAP) devices. The RIs of participants were measured at night using APAP devices, concurrently with electroencephalography, respiratory inductance plethysmography sensors, and other polysomnographic sensors in a sleep laboratory. The respiratory-related data of APAP were prospectively analyzed with the manually scored polysomnographic data. RESULTS: The apnea-hypopnea index and apnea index showed a statistically close relationship between the auto-scored respiratory data from the APAP device and the manually scored respiratory data from polysomnographic sensors. Obstructive apnea and central apnea indices showed relatively low correlations. The differences between the auto-scored RI and manually scored RI were influenced by BMI, waist circumference, weight, oxygen saturation, and respiratory distress indices of diagnostic polysomnographic factors. CONCLUSIONS: The RIs of APAP devices have a tendency to be underestimated or mismatched when compared with polysomnography. Sleep specialists are advised to consider additional anthropometric and diagnostic factors to account for these differences during PAP treatment.


Assuntos
Pressão Positiva Contínua nas Vias Aéreas/instrumentação , Respiração , Apneia Obstrutiva do Sono/fisiopatologia , Apneia Obstrutiva do Sono/terapia , Adulto , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Polissonografia , Reprodutibilidade dos Testes
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA