Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 134
Filtrar
1.
Radiologia (Engl Ed) ; 66(4): 307-313, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-39089791

RESUMO

INTRODUCTION: The use of abdominal radiography (AXR) apparently continues to be widespread despite its limited indications, the potential radiation and unnecessary costs associated. In addition, the interpretation and its report seem variable and not always performed by a radiologist. Our objective is to analyze the use, adequacy and usefulness of AXR in the emergency of a tertiary referral hospital. MATERIAL AND METHODS: We retrospectively reviewed all the AXR performed in January 2020 in the emergency of our centre, as well as the patient's demographics and medical records, technical quality of the radiographs, indications according to the SERAM (Spanish Society of Radiology) Appropriateness Guidelines, presence of a formal radiology report, and impact on the clinical management of the patient. Of all non-appropriated AXR we calculated the radiation received by the patients and its extra costs. RESULTS: In January 2020, 429 AXR (9.1% of all radiographies) were performed in the emergency of our centre. The most frequent indication was abdominal pain (40%, n = 176), followed by low back pain (21.4%, n = 92). 12.4% of AXR requested did not include any clinical information. Most of the AXR (79.6%) had sufficient technical quality. 61.3% (n = 263) of the AXR performed were not indicated, assuming an average unjustified radiation dose per patient of 0.50 ±â€¯0.33 mSv, and a total additional cost of 6575;. Only 6% of the inadequate AXRs led to a change in the clinical management of the patient, compared to 29% of the adequate AXR (p < 0.001). Only 3% of the AXR had a formal radiology report. CONCLUSIONS: AXR is still common in the emergency setting, although most of them might be inadequate according to the SERAM Appropriateness Guidelines. Its use should be optimized to avoid unnecessary radiation and costs. Radiologists must have a more active participation in the management of AXR.


Assuntos
Serviço Hospitalar de Emergência , Radiografia Abdominal , Humanos , Estudos Retrospectivos , Serviço Hospitalar de Emergência/economia , Radiografia Abdominal/economia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Proteção Radiológica/economia , Idoso , Idoso de 80 Anos ou mais , Utilização de Procedimentos e Técnicas , Adolescente , Adulto Jovem
2.
Health Phys ; 120(2): 217-223, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32740141

RESUMO

ABSTRACT: The full ALARA principle includes "as low as reasonably achievable" taking social and economic factors into consideration. The International Commission on Radiological Protection advises a conventional cost benefit approach (e.g., cost per monetized averted stochastic effects or years of life saved) to consider economic factors. Given small incremental radiation dose reductions to patients, workers, or the public that may be realized in medical settings and the correspondingly small changes to theoretical stochastic effects, a conventional cost benefit approach is less than ideal. This is illustrated in the case studies presented in this paper. Alternate approaches, such as cost per unit of radiation dose averted (e.g., $/µSv averted), cancer induction/fatality probabilistic thresholds, or thresholds relative to natural background radiation may be alternate options. However, the decision regarding what is a "safe" level of radiation and what are reasonable costs to make it "safer" are driven by societal values and may vary from jurisdiction to jurisdiction.


Assuntos
Análise Custo-Benefício , Proteção Radiológica/economia , Humanos
3.
Radiat Prot Dosimetry ; 186(4): 479-487, 2019 Dec 31.
Artigo em Inglês | MEDLINE | ID: mdl-31329996

RESUMO

Cost-risk-benefit analysis has been applied to protection of the patient in diagnostic radiology with special reference to the application of referral guidelines. The analysis presented has extended previous work in this field to provide a theoretical framework that encompasses key factors that need to be considered in the optimisation of patient protection from both diagnostic and radiation risks. The fraction of patients whose symptoms do not meet criteria contained in the referral guidelines and, therefore, for whom an X-ray examination is not indicated has been termed the selectivity of the guidelines. Also included are the detriments arising from rejected or repeated examinations as well as the levels of patient dose employed in order to achieve given levels of true and false diagnostic outcomes. A comprehensive framework for optimisation is outlined and its relationship to justification discussed.


Assuntos
Análise Custo-Benefício , Guias de Prática Clínica como Assunto/normas , Lesões por Radiação/economia , Lesões por Radiação/prevenção & controle , Monitoramento de Radiação/economia , Proteção Radiológica/economia , Radiografia/efeitos adversos , Simulação por Computador , Humanos , Doses de Radiação , Lesões por Radiação/etiologia , Radiologia , Encaminhamento e Consulta , Medição de Risco/economia , Raios X
4.
Pract Radiat Oncol ; 9(2): e172-e179, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30342180

RESUMO

PURPOSE: A hydrogel rectal spacer (HRS) is a medical device that is approved by the U.S. Food and Drug Administration to increase the separation between the prostate and rectum. We conducted a cost-effectiveness analysis of HRS use for reduction in radiation therapy (RT) toxicities in patients with prostate cancer (PC) undergoing external beam RT (EBRT). METHODS AND MATERIALS: A multistate Markov model was constructed from the U.S. payer perspective to examine the cost-effectiveness of HRS in men with localized PC receiving EBRT (EBRT alone vs EBRT + HRS). The subgroups analyzed included site of HRS placement (hospital outpatient, physician office, ambulatory surgery center) and proportion of patients with good baseline erectile function (EF). Data on EF, gastrointestinal and genitourinary toxicities incidence, and potential risks associated with HRS implantation were obtained from a recently published randomized clinical trial. Health utilities and costs were derived from the literature and the 2018 Physician Fee Schedule and were discounted 3% annually. Quality-adjusted life years (QALYs) and costs were modeled for a 5-year period from receipt of RT. Probabilistic sensitivity analysis and value-based threshold analyses were conducted. RESULTS: The per-patient 5-year incremental cost for spacers administered in a hospital outpatient setting was $3578, and the incremental effectiveness was 0.0371 QALYs. The incremental cost-effectiveness ratio was $96,440/QALY for patients with PC undergoing HRS insertion in a hospital and $39,286/QALY for patients undergoing HRS insertion in an ambulatory facility. For men with good baseline EF, the incremental cost-effectiveness ratio was $35,548/QALY and $9627/QALY in hospital outpatient and ambulatory facility settings, respectively. CONCLUSIONS: Based on the current Medicare Physician Fee Schedule, HRS is cost-effective at a willingness to pay threshold of $100,000. These results contain substantial uncertainty, suggesting more evidence is needed to refine future decision-making.


Assuntos
Hidrogéis/economia , Neoplasias da Próstata/radioterapia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/métodos , Reto/efeitos da radiação , Análise Custo-Benefício , Custos de Cuidados de Saúde , Humanos , Masculino , Cadeias de Markov , Modelos Econômicos , Órgãos em Risco/efeitos da radiação , Próstata/patologia , Anos de Vida Ajustados por Qualidade de Vida , Lesões por Radiação/etiologia , Proteção Radiológica/economia , Estados Unidos
5.
Int J Radiat Oncol Biol Phys ; 104(1): 188-196, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30583040

RESUMO

PURPOSE: The use of radioprotectors and radiomitigators could improve the therapeutic index of radiation therapy. With the intention of accelerating translation of radiation-effect modulators (radioprotectors and mitigators), the Radiation Research Program and SBIR (Small Business Innovation Research) Development Center within the National Cancer Institute issued 4 Requests for Proposals (RFPs) from 2010 to 2013. Twelve SBIR contract awards in total were made in response to the 4 RFPs from September 2011 through September 2014. Here, we provide an update on the status of SBIR contract projects for the development of radiation-effect modulators. METHODS AND MATERIALS: To assess the status of research and development efforts under the 4 RFPs on radiation-effect modulators, we searched PubMed for research articles, google.com for published abstracts, clinicaltrials.gov for ongoing or completed clinical trials, and company websites for press releases and other news. All information obtained and reported here is publicly available and thus protects the intellectual property of the investigators and companies. RESULTS: Of the 12 SBIR projects funded, 5 (42%) transitioned successfully from phase 1 to phase 2 SBIR funding, and among the Fast-Track contracts, this rate was 100% (3 of 3). The Internet search identified 3 abstracts and 6 publications related to the aims of the SBIR contracts. One-third of the companies (4 of 12) have successfully launched a total of 8 clinical trials to demonstrate the safety and efficacy of their investigational agents. Two drugs are in clinical trials for their indication as a radioprotector, and 2 drugs are under evaluation for their anticancer properties (an immunomodulator and a small molecule inhibitor). CONCLUSIONS: The National Cancer Institute's SBIR has provided pivotal funding to small businesses for the development of radioprotectors and radiomitigators, which resulted in multiple early-phase clinical trials. Longer follow-up is needed to determine the full impact of these novel therapeutics that enter clinical practice.


Assuntos
Contratos/economia , Financiamento Governamental , Invenções/economia , National Cancer Institute (U.S.) , Proteção Radiológica/instrumentação , Empresa de Pequeno Porte/economia , Tecnologia Radiológica/economia , Humanos , Proteção Radiológica/economia , Estados Unidos
6.
Radiat Prot Dosimetry ; 173(1-3): 69-72, 2017 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-27986967

RESUMO

When a cost-benefit analysis is applied to the optimization of practices involving radiation protection, the alpha value is used to determine the amount of money required to be invested in a practice to minimize radiation doses to acceptable levels. The alpha value is often linked to the gross domestic product (GDP) per capita, so the monetary reference value of person-Sievert can often be different in each country. Evaluation of the alpha value in Brazil was performed in 1993 and 2000 making use of the procedure advised by ICRP to produce projections up to 2015 and subsequently in 2004 by using the procedure recommended by the IAEA. This paper, in response to the social and economic situation in Brazil, calculates the alpha value and compares it with the projections of the 1993 and 2000 papers and includes a dollar correction to take account of the differences in the purchasing power from that time. This procedure illustrates the significant gap of value in use and that the actual value should be two to three times higher. By GDP per capita, the authors could calculate the alpha value updated to various countries including the European Union and compare them with the official value currently in use. In conclusion, it is believed that all countries that adopt an alpha value should upgrade it to the present day.


Assuntos
Produto Interno Bruto , Proteção Radiológica/economia , Brasil , Análise Custo-Benefício , Humanos
7.
Health Phys ; 112(2): 207-213, 2017 02.
Artigo em Inglês | MEDLINE | ID: mdl-28027163

RESUMO

The health physics profession was born abruptly when once rare and precious radioactive materials became commonplace. The technological advancements that triggered an industrial complex and ended World War II demanded radiation safety on an unprecedented scale. Until then, protective measures against radiation were largely absent in laboratories. Over the subsequent decades, health physicists began protecting people and the environment in a wide range of settings including medical, research, and industrial. The use of radioactive materials and radiation-generating devices is prevalent today. Radiation doses occur continuously including during airline flights, in our homes, during medical procedures, and in energy production. Radiation is integral to numerous applications including those in medicine, dentistry, manufacturing, construction, scientific research, nuclear electric power generation, and oil and gas exploration. Activities that were once groundbreaking have now become routine and scripted. At higher doses, health effects are understood and avoided. Instruments for the detection and measurement of radiation are at times smarter than their users. Ironically, the same health physics community that has been successful in demonstrating that exposures to radiation and to radioactive materials can be effectively managed is shrinking at an increasingly rapid rate. This paper highlights the creation of past and current jobs, predicts the future opportunities in the profession, and makes recommendations necessary to protect the disappearing specialties.


Assuntos
Física Médica/economia , Mão de Obra em Saúde/estatística & dados numéricos , Marketing de Serviços de Saúde/economia , Marketing de Serviços de Saúde/tendências , Proteção Radiológica/economia , Escolha da Profissão , Emprego/economia , Emprego/tendências , Necessidades e Demandas de Serviços de Saúde/economia , Necessidades e Demandas de Serviços de Saúde/tendências , Mão de Obra em Saúde/tendências , Proteção Radiológica/estatística & dados numéricos , Estados Unidos
8.
Radiat Prot Dosimetry ; 169(1-4): 2-10, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-26705358

RESUMO

In 1973, International Commission on Radiological Protection Publication 22 recommended that the acceptability of radiation exposure levels for a given activity should be determined by a process of cost-benefit analysis. It was felt that this approach could be used to underpin both the principle of ALARA as well for justification purposes. The net benefit, B, of an operation involving irradiation was regarded as equal to the difference between its gross benefit, V, and the sum of three components; the basic production cost associated with the operation, P; the cost of achieving the selected level of protection, X; and the cost Y of the detriment involved in the operation: [Formula: see text] This article presents a theoretical cost-risk-benefit analysis that is applicable to the diagnostic accuracy (Levels 1 and 2) of the hierarchical efficacy model presented by National Council on Radiation Protection and Measurements in 1992. This enables the costs of an examination to be related to the sensitivity and specificity of an X-ray examination within a defined clinical problem setting and introduces both false-positive/false-negative diagnostic outcomes into the patient radiation protection framework.


Assuntos
Custos de Cuidados de Saúde/estatística & dados numéricos , Modelos Econômicos , Lesões por Radiação/economia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/economia , Radiografia/economia , Simulação por Computador , Humanos , Prevalência , Medição de Risco/economia
9.
Dentomaxillofac Radiol ; 44(9): 20150158, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26119214

RESUMO

OBJECTIVES: To find a method that is suitable for providing an objective assessment of the cost effectiveness of a dose-reducing measure used for diagnostic dental X-ray exposures. METHODS: Three cost-utility analysis (CUA) methods were evaluated by comparing their assessments of two dose-reduction measures, a rectangular collimator and the combination of two devices that reduce the radiation dose received during orthodontic lateral cephalography. The following CUA methods were used: (1) the alpha value (AV), a monetary valuation of dose reduction used in the nuclear industry; (2) the value of a statistical life for valuation of the reduction in stochastic adverse effects; and (3) the time-for-time method, based on the postulate that risk reduction is effective when the number of years of life gained is more than the years that an average worker must work to earn the costs of the risk-reducing measure. The CUA methods were used to determine the minimum number of uses that was required for the dose-reducing device to be cost effective. The methods were assessed for coherence (are comparable results achieved for comparable countries?) and adaptability (can the method be adjusted for age and gender of specific patient groups?). RESULTS: The performance of the time-for-time method was superior to the other methods. Both types of dose-reduction devices tested were assessed as cost effective after a realistic number of uses with all three methods except low AVs. CONCLUSIONS: CUA for the methods of X-ray dose reduction can be performed to determine if investment in low dose reduction is cost effective. The time-for-time method proved to be a coherent and versatile method for performing CUA.


Assuntos
Doses de Radiação , Proteção Radiológica/métodos , Radiografia Dentária/métodos , Fatores Etários , Algoritmos , Cefalometria/economia , Cefalometria/instrumentação , Cefalometria/métodos , Análise Custo-Benefício , Humanos , Lesões por Radiação/economia , Lesões por Radiação/prevenção & controle , Proteção Radiológica/economia , Proteção Radiológica/instrumentação , Radiografia Dentária/economia , Radiografia Dentária/instrumentação , Fatores Sexuais , Processos Estocásticos , Valor da Vida
10.
Radiat Prot Dosimetry ; 164(4): 519-22, 2015 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-25979740

RESUMO

Costs related to the decommissioning of nuclear power plants create a significant financial burden for nuclear power plant operators. This article discusses the various methodologies employed by selected European countries for financing of the liabilities related to the nuclear power plant decommissioning. The article also presents methodology of allocation of future decommissioning costs to the running costs of nuclear power plant in the form of fee imposed on each megawatt hour generated. The application of the methodology is presented in the form of a case study on a new nuclear power plant with installed capacity 1000 MW.


Assuntos
Recuperação e Remediação Ambiental/economia , Modelos Econômicos , Energia Nuclear/economia , Centrais Nucleares/economia , Resíduos Radioativos/economia , Eliminação de Resíduos/economia , Alocação de Custos , Custos e Análise de Custo , Europa (Continente) , Organização do Financiamento , Exposição à Radiação , Monitoramento de Radiação/economia , Proteção Radiológica/economia , Radioisótopos/análise , Fatores de Tempo , Instalações de Eliminação de Resíduos/economia
11.
Cancer Radiother ; 18(5-6): 437-40, 2014 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-25195117

RESUMO

Since February 2014, it is no longer possible to use low-dose rate 192 iridium wires due to the end of industrial production of IRF1 and IRF2 sources. The Brachytherapy Group of the French society of radiation oncology (GC-SFRO) has recommended switching from iridium wires to after-loading machines. Two types of after-loading machines are currently available, based on the dose rate used: pulsed-dose rate or high-dose rate. In this article, we propose a comparative analysis between pulsed-dose rate and high-dose rate brachytherapy, based on biological, technological, organizational and financial considerations.


Assuntos
Braquiterapia/instrumentação , Automação , Braquiterapia/economia , Braquiterapia/métodos , Braquiterapia/enfermagem , Ensaios Clínicos como Assunto , Análise Custo-Benefício , Relação Dose-Resposta à Radiação , Arquitetura de Instituições de Saúde/economia , Humanos , Radioisótopos de Irídio/administração & dosagem , Radioisótopos de Irídio/uso terapêutico , Neoplasias/radioterapia , Aceitação pelo Paciente de Cuidados de Saúde , Isolamento de Pacientes/economia , Quartos de Pacientes/economia , Radioterapia (Especialidade)/organização & administração , Proteção Radiológica/economia , Dosagem Radioterapêutica , Fatores de Tempo , Resultado do Tratamento
14.
Radiat Prot Dosimetry ; 160(1-3): 30-4, 2014 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-24723196

RESUMO

A health economics evaluation of different radon intervention strategies was undertaken including the incorporation of prevention into new buildings, the incorporation of potential remedial measures into new buildings and remediation of existing buildings. The analysis shows that (1) the incorporation of prevention into new houses at the time of construction is generally more cost effective than remediation of existing houses and (2) that the cost effectiveness of programmes aimed at encouraging householders to test and remediate their houses may be poor if they are not undertaken within the context of coherent radon reduction strategy. The results of this evaluation were used to identify the most cost-effective radon interventions in an Irish context in support of the development of a National Radon Control Strategy.


Assuntos
Análise Custo-Benefício , Exposição Ambiental/prevenção & controle , Programas Nacionais de Saúde/economia , Monitoramento de Radiação/normas , Proteção Radiológica/normas , Poluentes Radioativos/análise , Radônio/análise , Exposição Ambiental/economia , Humanos , Irlanda , Monitoramento de Radiação/economia , Proteção Radiológica/economia , Poluentes Radioativos/efeitos adversos , Poluentes Radioativos/economia , Radônio/efeitos adversos
15.
AJR Am J Roentgenol ; 202(1): 124-35, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24370137

RESUMO

OBJECTIVE: The costs of an ultrasound-CT protocol and a CT-only protocol for an appendicitis evaluation are compared. For the ultrasound-CT protocol, patients with right lower quadrant abdominal pain undergo an ultrasound examination. If it is positive for appendicitis, they are sent directly to surgery, avoiding CT. MATERIALS AND METHODS: A comparative effectiveness research study was conducted. The costs of imaging tests, excess surgeries, and excess surgical deaths for the ultrasound-CT protocol and the costs of imaging tests and excess cancer deaths in the CT-only protocol were estimated. Data sources were Centers for Medicare & Medicaid Services (CMS) datasets, national hospital discharge surveys, radiology information system cases, and U.S. Census Bureau life tables. A meta-analysis and sensitivity analyses were also conducted. RESULTS: The meta-analysis showed a positive predictive value of 92.5% for CT and 91.0% for ultrasound. Analysis of CMS files showed that utilization of CT was almost exactly 2.0 examinations (one abdominal and one pelvic) per patient and for ultrasound was almost nil. The cost of this imaging protocol was $547 per patient, whereas the cost of a limited ultrasound study would be $88 per patient. For the total U.S. population, the cost savings in imaging minus the cost of extra surgeries and extra surgical deaths is $24.9 million per year. Following model VII proposed by the Committee on the Biological Effects of Ionizing Radiation (BEIR), which is known as "BEIR VII," the avoidance of a 12.4-mSv exposure for 262,500 persons would prevent 180 excess cancer deaths. The value of the years of life lost would be $339.5 million. The sensitivity analyses indicate that the cost savings are robust. CONCLUSION: An ultrasound-CT protocol for appendicitis evaluation offers potentially large savings over the standard CT-only protocol. There are moderate savings from using a less expensive imaging technique despite extra surgeries and large savings from radiation exposure avoided.


Assuntos
Apendicite/diagnóstico por imagem , Redução de Custos , Proteção Radiológica/economia , Proteção Radiológica/métodos , Tomografia Computadorizada por Raios X/economia , Ultrassonografia/economia , Algoritmos , Pesquisa Comparativa da Efetividade , Humanos , Doses de Radiação
16.
J Radiat Res ; 55(2): 320-7, 2014 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-24187330

RESUMO

BACKGROUND: The aim of this study is to evaluate the cost-effectiveness of proton beam therapy with cochlear dose reduction compared with conventional X-ray radiotherapy for medulloblastoma in childhood. METHODS: We developed a Markov model to describe health states of 6-year-old children with medulloblastoma after treatment with proton or X-ray radiotherapy. The risks of hearing loss were calculated on cochlear dose for each treatment. Three types of health-related quality of life (HRQOL) of EQ-5D, HUI3 and SF-6D were used for estimation of quality-adjusted life years (QALYs). The incremental cost-effectiveness ratio (ICER) for proton beam therapy compared with X-ray radiotherapy was calculated for each HRQOL. Sensitivity analyses were performed to model uncertainty in these parameters. RESULTS: The ICER for EQ-5D, HUI3 and SF-6D were $21 716/QALY, $11 773/QALY, and $20 150/QALY, respectively. One-way sensitivity analyses found that the results were sensitive to discount rate, the risk of hearing loss after proton therapy, and costs of proton irradiation. Cost-effectiveness acceptability curve analysis revealed a 99% probability of proton therapy being cost effective at a societal willingness-to-pay value. CONCLUSIONS: Proton beam therapy with cochlear dose reduction improves health outcomes at a cost that is within the acceptable cost-effectiveness range from the payer's standpoint.


Assuntos
Neoplasias Cerebelares/economia , Neoplasias Cerebelares/radioterapia , Perda Auditiva/economia , Meduloblastoma/economia , Meduloblastoma/radioterapia , Qualidade de Vida , Lesões por Radiação/economia , Neoplasias Cerebelares/mortalidade , Criança , Cóclea/efeitos da radiação , Análise Custo-Benefício/classificação , Análise Custo-Benefício/economia , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Perda Auditiva/mortalidade , Perda Auditiva/prevenção & controle , Humanos , Japão , Masculino , Meduloblastoma/mortalidade , Modelos Econômicos , Tratamentos com Preservação do Órgão/economia , Tratamentos com Preservação do Órgão/métodos , Órgãos em Risco/efeitos da radiação , Terapia com Prótons , Lesões por Radiação/prevenção & controle , Proteção Radiológica/economia , Dosagem Radioterapêutica , Radioterapia de Alta Energia/economia , Radioterapia de Alta Energia/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
17.
Radiat Res ; 180(6): 567-74, 2013 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-24164553

RESUMO

The dose of a substance that causes death in P% of a population is called an LDP, where LD stands for lethal dose. In radiation research, a common LDP of interest is the radiation dose that kills 50% of the population by a specified time, i.e., lethal dose 50 or LD50. When comparing LD50 between two populations, relative potency is the parameter of interest. In radiation research, this is commonly known as the dose reduction factor (DRF). Unfortunately, statistical inference on dose reduction factor is seldom reported. We illustrate how to calculate confidence intervals for dose reduction factor, which may then be used for statistical inference. Further, most dose reduction factor experiments use hundreds, rather than tens of animals. Through better dosing strategies and the use of a recently available sample size formula, we also show how animal numbers may be reduced while maintaining high statistical power. The illustrations center on realistic examples comparing LD50 values between a radiation countermeasure group and a radiation-only control. We also provide easy-to-use spreadsheets for sample size calculations and confidence interval calculations, as well as SAS® and R code for the latter.


Assuntos
Bem-Estar do Animal , Intervalos de Confiança , Guias como Assunto , Proteção Radiológica , Animais , Dose Letal Mediana , Modelos Estatísticos , Doses de Radiação , Proteção Radiológica/economia
18.
J Am Coll Radiol ; 10(11): 864-8, 2013 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24075218

RESUMO

BACKGROUND: Inappropriate catheter requests at the McGill University Health Centre (MUHC) led to significantly increased costs and early catheter malfunction or infection. Dual-lumen catheters were often requested and inserted when only a single lumen was required, and inappropriate catheter care on the wards led to early infection or thrombosis. METHODS: A full-time registered nurse was hired to analyze and transform the vascular access program of the MUHC. Catheter selection was streamlined on the basis of clinical unit need. Clinical and cost data were collected between May 2011 and January 2012. RESULTS: Requests for vascular access at the MUHC have been standardized and centralized. Single-lumen catheters are inserted unless a specific indication for a dual-lumen catheter is provided. To date, data have been collected on >4,000 catheter insertions, both before and after the switch to the single-lumen program. Dual-lumen catheters have been required in only 50% of cases. Reinsertion rates have decreased, leading to the first year-over-year reduction in peripherally inserted central venous catheter insertion since data collection began in 2002. The program has also resulted in significant reductions in central line-associated bloodstream infection and catheter-related thrombosis. Decreased maintenance and reinsertion costs have led to overall savings for the MUHC of approximately $1.1 million.


Assuntos
Infecções Relacionadas a Cateter/economia , Infecções Relacionadas a Cateter/prevenção & controle , Cateterismo Venoso Central/economia , Cateterismo Venoso Central/estatística & dados numéricos , Custos de Cuidados de Saúde/estatística & dados numéricos , Radiografia Intervencionista/economia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Criança , Pré-Escolar , Redução de Custos/economia , Redução de Custos/métodos , Redução de Custos/estatística & dados numéricos , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Pessoa de Meia-Idade , Quebeque/epidemiologia , Doses de Radiação , Proteção Radiológica/economia , Proteção Radiológica/estatística & dados numéricos , Radiografia Intervencionista/estatística & dados numéricos , Adulto Jovem
19.
Environ Int ; 59: 73-85, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23792416

RESUMO

In the UK, excessive levels of radon gas have been detected in domestic housing. Areas where 1% of existing homes were found to be over the Action Level of 200Bq·m(-3) were declared to be Radon Affected Areas. Building Regulations have been introduced which require that, for areas where between 3% and 10% of existing houses are above the Action Level, new homes should be built with basic radon protection using a membrane, and that, where 10% or more of existing homes exceed this level, new homes should be built with full radon protection. Initially these affected areas followed administrative boundaries, known as Counties. However, with increasing numbers of measurements of radon levels in domestic homes recorded in the national database, these areas have been successively refined into smaller units - 5km grid squares in 1999, down to 1km grid squares in 2007. One result is the identification of small areas with raised radon levels within regions where previously no problem had been identified. In addition, some parts of areas that were previously considered radon affected are now considered low, or no, risk. Our analysis suggests that the net result of improved mapping is to increase the number of affected houses. Further, the process is more complex for local builders, and inspectors, who need to work out whether radon protection in new homes is appropriate. Our group has assessed the cost-effectiveness of radon remediation programmes, and has applied this analysis to consider the cost-effectiveness of providing radon protection in both new and existing homes. This includes modelling the potential failure rate of membranes, and whether testing radon levels in new homes is appropriate. The analysis concludes that it is more cost effective to provide targeted radon protection in high radon areas, although this introduces more complexity. The paper also considers the trend in housing to a greater proportion of apartments, the regional variations in types of housing and the decreasing average number of occupants in each dwelling, and concludes that data and methods are now available to respond to the health risks of radon at a local level, in keeping with a general initiative to prioritise responses to health and social welfare issues at a more local level.


Assuntos
Habitação/normas , Habitação/tendências , Proteção Radiológica/economia , Radônio/efeitos adversos , Análise Custo-Benefício , Inglaterra , Humanos , Radônio/análise , País de Gales
20.
Skeletal Radiol ; 42(7): 959-67, 2013 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-23536038

RESUMO

OBJECTIVE: To compare the radiation dose, workflow, patient comfort, and financial break-even of a standard digital radiography and a biplanar low-dose X-ray system. MATERIALS AND METHODS: A standard digital radiography system (Ysio, Siemens Healthcare, Erlangen, Germany) was compared with a biplanar X-ray unit (EOS, EOS imaging, Paris, France) consisting of two X-ray tubes and slot-scanning detectors, arranged at an angle of 90° allowing simultaneous vertical biplanar linear scanning in the upright patient position. We compared data of standing full-length lower limb radiographs and whole spine radiographs of both X-ray systems. RESULTS: Dose-area product was significantly lower for radiographs of the biplanar X-ray system than for the standard digital radiography system (e.g. whole spine radiographs; standard digital radiography system: 392.2 ± 231.7 cGy*cm(2) versus biplanar X-ray system: 158.4 ± 103.8 cGy*cm(2)). The mean examination time was significantly shorter for biplanar radiographs compared with standard digital radiographs (e.g. whole spine radiographs: 449 s vs 248 s). Patients' comfort regarding noise was significantly higher for the standard digital radiography system. The financial break-even point was 2,602 radiographs/year for the standard digital radiography system compared with 4,077 radiographs/year for the biplanar X-ray unit. CONCLUSION: The biplanar X-ray unit reduces radiation exposure and increases subjective noise exposure to patients. The biplanar X-ray unit demands a higher number of examinations per year for the financial break-even point, despite the lower labour cost per examination due to the shorter examination time.


Assuntos
Perna (Membro)/diagnóstico por imagem , Satisfação do Paciente/estatística & dados numéricos , Proteção Radiológica/economia , Intensificação de Imagem Radiográfica/economia , Coluna Vertebral/diagnóstico por imagem , Tomografia Computadorizada por Raios X/economia , Fluxo de Trabalho , Adulto , Idoso , Análise Custo-Benefício/estatística & dados numéricos , Feminino , Custos de Cuidados de Saúde/estatística & dados numéricos , Humanos , Masculino , Pessoa de Meia-Idade , Doses de Radiação , Proteção Radiológica/instrumentação , Intensificação de Imagem Radiográfica/instrumentação , Radiometria , Suíça/epidemiologia , Tomografia Computadorizada por Raios X/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA