Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 15.296
Filtrar
1.
Methodist Debakey Cardiovasc J ; 20(3): 49-56, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38765211

RESUMO

For patients with existing venous thromboembolisms (VTEs), anticoagulation remains the standard of care recommended across multiple professional organizations. However, for patients who developed a deep venous thrombosis (DVT) and/or a pulmonary embolism and cannot tolerate anticoagulation, inferior vena cava (IVC) filters must be considered among other alternative treatments. Although placement of a filter is considered a low-risk intervention, there are important factors and techniques that surgeons and interventionalists should be aware of and prepared to discuss. This overview covers the basics regarding the history of filters, indications for placement, associated risks, and techniques for difficult removal.


Assuntos
Remoção de Dispositivo , Desenho de Prótese , Implantação de Prótese , Embolia Pulmonar , Filtros de Veia Cava , Trombose Venosa , Humanos , Embolia Pulmonar/prevenção & controle , Trombose Venosa/prevenção & controle , Trombose Venosa/terapia , Fatores de Risco , Implantação de Prótese/instrumentação , Implantação de Prótese/efeitos adversos , Resultado do Tratamento , Tromboembolia Venosa/prevenção & controle , Tromboembolia Venosa/diagnóstico , Veia Cava Inferior/diagnóstico por imagem , Medição de Risco , Anticoagulantes/uso terapêutico , Anticoagulantes/efeitos adversos
2.
Isr Med Assoc J ; 26(5): 273-277, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38736340

RESUMO

BACKGROUND: Cardiac implantable electronic devices (CIEDs) are increasingly being used; thus, there is an increasing need for transvenous lead extraction (TLE). OBJECTIVES: To summarize our experience with TLE at single referral center in northern Israel. METHODS: The study included all patients who underwent TLE at our center between 2019 and 2022, regardless of the indication. RESULTS: The cohort included 50 patients. The mean age was 69 ± 10.36 years; 78% were males. A total of 99 electrodes were targeted. The mean number of electrodes was 1.96 (range 1-4) per patient. The time between lead implantation and extraction ranged between 1.1 and 34 years with an average of 8.14 ± 5.71 years (median of 7.5 years). Complete lead removal was achieved in 98% of patients and in 98.99% of leads. The complete procedural success rate as well as the clinical procedural success rate was 96%. The procedural failure rate was 4% (1 patient died 2 days after the index procedure and 1 patient remained with large portion of lead). The indication for TLE was infection in 78% of the cohort group. Powered mechanical sheaths were used in 36 patients (72%), laser sheaths in 27 (54%), and a combination of laser and mechanical sheaths in 16 (32%). CONCLUSIONS: The clinical and procedural success rates of TLE, primarily for CEID-related infection, were high. A combination of laser and mechanical sheaths was needed in one-third of patients.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Humanos , Remoção de Dispositivo/métodos , Remoção de Dispositivo/estatística & dados numéricos , Masculino , Israel/epidemiologia , Feminino , Idoso , Estudos Retrospectivos , Resultado do Tratamento , Pessoa de Meia-Idade , Eletrodos Implantados , Idoso de 80 Anos ou mais
4.
Clin Transplant ; 38(5): e15321, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38716774

RESUMO

INTRODUCTION & OBJECTIVES: To evaluate ureteral stent removal (SR) using a grasper-integrated disposable flexible cystoscope (giFC-Isiris ®, Coloplast ®) after kidney transplantation (KT), with a focus on feasibility, safety, patient experience, and costs. MATERIAL AND METHODS: All consecutive KT undergoing SR through giFC were prospectively enrolled from January 2020 to June 2023. Patient characteristics, KT and SR details, urine culture results, antimicrobial prescriptions, and the incidence of urinary tract infections (UTI) within 1 month were recorded. A micro-cost analysis was conducted, making a comparison with the costs of SR with a reusable FC and grasper. RESULTS: A total of 136 KT patients were enrolled, including both single and double KT, with 148 stents removed in total. The median indwelling time was 34 days [26, 47]. SR was successfully performed in all cases. The median preparation and procedure times were 4 min [3,5]. and 45 s[30, 60], respectively. The median Visual Analog Scale (VAS) score was 3 [1, 5], and 98.2% of patients expressed willingness to undergo the procedure again. Only one episode of UTI involving the graft (0.7%) was recorded. Overall, the estimated cost per SR procedure with Isiris ® and the reusable FC was 289.2€ and 151,4€, respectively. CONCLUSIONS: This prospective series evaluated the use of Isiris ® for SR in a cohort of KT patients, demonstrating feasibility and high tolerance. The UTI incidence was 0.7% within 1 month. Based on the micro-cost analysis, estimated cost per procedure favored the reusable FC.


Assuntos
Cistoscopia , Remoção de Dispositivo , Equipamentos Descartáveis , Estudos de Viabilidade , Transplante de Rim , Stents , Humanos , Feminino , Masculino , Transplante de Rim/economia , Pessoa de Meia-Idade , Stents/economia , Remoção de Dispositivo/economia , Estudos Prospectivos , Seguimentos , Equipamentos Descartáveis/economia , Cistoscopia/economia , Cistoscopia/métodos , Cistoscopia/instrumentação , Complicações Pós-Operatórias , Centros de Atenção Terciária , Prognóstico , Adulto , Ureter/cirurgia , Infecções Urinárias/etiologia , Infecções Urinárias/economia , Custos e Análise de Custo
5.
Sci Rep ; 14(1): 10192, 2024 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702341

RESUMO

Inferior vena cava (IVC) filters are considered when patients with venous thromboembolism (VTE) develop a contraindication to anticoagulation. Use of IVC filters is increasing, despite associated complications and lack of data on efficacy in reducing VTE-related mortality. We characterized the pattern of IVC filter use at a large community hospital between 2018 and 2022. Specifically, we assessed the indications for IVC filter insertion, filter removal rates, and filter-associated complications. Indications for IVC filters were compared to those outlined by current clinical practice guidelines. We reviewed 120 consecutive filter placement events. The most common indications included recent VTE and active bleeding (40.0%) or need for anticoagulation interruption for surgery (25.8%). Approximately one-third (30.0%) of IVC filters were inserted for indications either not supported or addressed by guidelines. Half (50.0%) of patients had successful removal of their IVC filter. At least 13 patients (10.8%) experienced a filter-related complication. In a large community-based practice, nearly one-third of IVC filters were inserted for indications not universally supported by current practice guidelines. Moreover, most IVC filters were not removed, raising the risk of filter-associated complications, and supporting the need for development of comprehensive guidelines addressing use of IVC filters, and post-insertion monitoring practices.


Assuntos
Hospitais Comunitários , Filtros de Veia Cava , Tromboembolia Venosa , Humanos , Estudos Retrospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Tromboembolia Venosa/prevenção & controle , Idoso , Anticoagulantes/uso terapêutico , Adulto , Remoção de Dispositivo/métodos
6.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735949

RESUMO

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Assuntos
Parafusos Ósseos , Fraturas do Colo Femoral , Análise de Elementos Finitos , Fixação Interna de Fraturas , Humanos , Fenômenos Biomecânicos , Fraturas do Colo Femoral/cirurgia , Fixação Interna de Fraturas/métodos , Colo do Fêmur/cirurgia , Colo do Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Estresse Mecânico , Remoção de Dispositivo/métodos
7.
BMC Musculoskelet Disord ; 25(1): 353, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38724941

RESUMO

BACKGROUND: External fixation is widely used in the treatment of traumatic fractures; however, orthopedic surgeons encounter challenges in deciding the optimal time for fixator removal. The axial load-share ratio (LS) of the fixator is a quantitative index to evaluate the stiffness of callus healing. This paper introduces an innovative method for measuring the LS and assesses the method's feasibility and efficacy. Based on a novel hexapod LS-measurement system, the proposed method is to improve the convenience and precision of measuring LS in vivo, hence facilitating the safe removal of external fixators. METHODS: A novel hexapod system is introduced, including its composition, theoretical model, and method for LS measurement. We conducted a retrospective study on 82 patients with tibial fractures treated by the Taylor Spatial Frame in our hospital from September 2018 to June 2020, of which 35 took LS measurements with our novel method (Group I), and 47 were with the traditional method (Group II). The external fixator was removed when the measurement outcome (LS < 10%) was consistent with the surgeon's diagnosis based on the clinical and radiological assessment (bone union achieved). RESULTS: No significant difference was found in the fracture healing time (mean 25.3 weeks vs. 24.9 weeks, P > 0.05), frame-wearing duration (mean 25.5 weeks vs. 25.8 weeks, P > 0.05), or LS measurement frequency (mean 1.1 times vs. 1.2 times, P > 0.05). The measurement system installation time in Group I was significantly shorter compared to Group II (mean 14.8 min vs. 81.3 min, P < 0.001). The LS value of the first measurement in Group I was lower than that of Group II (mean 5.1% vs. 6.9%, P = 0.011). In Group I, the refracture rate was 0, but in Group II it was 4.3% (2/47, P > 0.05). CONCLUSION: The novel hexapod LS-measurement system and involved method demonstrated enhanced convenience and precision in measuring the LS of the external fixator in vivo. The LS measurement indicates the callus stiffness of fracture healing, and is applicable to evaluate the safety of removing the fixator. Consequently, it is highly recommended for widespread adoption in clinical practice.


Assuntos
Remoção de Dispositivo , Fixadores Externos , Fixação de Fratura , Consolidação da Fratura , Fraturas da Tíbia , Humanos , Feminino , Fraturas da Tíbia/cirurgia , Masculino , Estudos Retrospectivos , Adulto , Pessoa de Meia-Idade , Fixação de Fratura/instrumentação , Fixação de Fratura/métodos , Remoção de Dispositivo/métodos , Suporte de Carga , Adulto Jovem , Idoso , Estudos de Viabilidade , Desenho de Equipamento
8.
J Med Case Rep ; 18(1): 234, 2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38698425

RESUMO

BACKGROUND: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval. Patients may present with symptoms mimicking a pulmonary embolism, or without any symptoms at all. In asymptomatic cases, endovascular retrieval and/or surgery is required when patients wish to begin having children prior to biological inactivity. The current literature showed as little as nine case reports detailing lung tissue removal in the aim of reversing a patient's implanted contraceptive device. CASE PRESENTATION: A 22-year-old asymptomatic active-duty Caucasian female presented for elective outpatient Nexplanon removal. The suspicion of possible implant migration arose when it was discovered to be non-palpable in her left arm. After plain film x-rays failed to localize the implant, a chest x-ray and follow-up Computed Tomography (CT) scan revealed that the Nexplanon had migrated to a distal branch of the left pulmonary artery. Due to the patient's strong desires to begin having children, the decision was made for removal. Initial endovascular retrieval failed due to Nexplanon encapsulation within the arterial wall. Ultimately, the patient underwent a left video-assisted thoracoscopic surgery (VATS) for exploration and left lower lobe basilar S7-9 segmentectomy, which successfully removed the Nexplanon. CONCLUSIONS: Implanted contraceptive devices can rarely result in migration to the pulmonary vasculature. These radiopaque devices are detectable on imaging studies if patients and clinicians are unable to palpate them. An endovascular approach should be considered first to spare lung tissue and avoid chest-wall incisions, but can be complicated by encapsulation and adherence to adjacent tissue. A VATS procedure with single-lung ventilation via a double-lumen endotracheal tube allows surgeons to safely operate on an immobilized lung while anesthesiologists facilitate single-lung ventilation. This patient's case details the uncommon phenomenon of Nexplanon migration, and the exceedingly rare treatment resolution of lung resection to remove an embolized device.


Assuntos
Desogestrel , Remoção de Dispositivo , Migração de Corpo Estranho , Humanos , Feminino , Remoção de Dispositivo/métodos , Desogestrel/administração & dosagem , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Adulto Jovem , Anticoncepcionais Femininos/administração & dosagem , Implantes de Medicamento , Artéria Pulmonar/cirurgia , Artéria Pulmonar/diagnóstico por imagem , Tomografia Computadorizada por Raios X , Embolia Pulmonar/etiologia , Resultado do Tratamento , Pneumonectomia
9.
BMJ Open ; 14(5): e081749, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760049

RESUMO

OBJECTIVES: To compare catheter-related outcomes of individuals who received a tunnelled femorally inserted central catheter (tFICC) with those who received a peripherally inserted central catheter (PICC) in the upper extremities. DESIGN: A propensity-score matched cohort study. SETTING: A 980-bed tertiary referral hospital in South West Sydney, Australia. PARTICIPANTS: In-patients referred to the hospital central venous access service for the insertion of a central venous access device. PRIMARY AND SECONDARY OUTCOME MEASURES: The primary outcome of interest was the incidence of all-cause catheter failure. Secondary outcomes included the rates of catheters removed because of suspected or confirmed catheter-associated infection, catheter dwell and confirmed upper or lower extremity deep vein thrombosis (DVT). RESULTS: The overall rate of all-cause catheter failure in the matched tFICC and PICC cohort was 2.4/1000 catheter days (95% CI 1.1 to 4.4) and 3.0/1000 catheter days (95% CI 2.3 to 3.9), respectively, and when compared, no difference was observed (difference -0.63/1000 catheter days, 95% CI -2.32 to 1.06). We found no differences in catheter dwell (mean difference of 14.2 days, 95% CI -6.6 to 35.0, p=0.910); or in the cumulative probability of failure between the two groups within the first month of dwell (p=0.358). No significant differences were observed in the rate of catheters requiring removal for confirmed central line-associated bloodstream infection (difference 0.13/1000 catheter day, 95% CI -0.36 to 0.63, p=0.896). Similarly, no significant differences were found between the groups for confirmed catheter-related DVT (difference -0.11 per 1000 catheter days, 95% CI -0.26 to 0.04, p=1.00). CONCLUSION: There were no differences in catheter-related outcomes between the matched cohort of tFICC and PICC patients, suggesting that tFICCs are a possible alternative for vascular access when the veins of the upper extremities or thoracic region are not viable for catheterisation.


Assuntos
Infecções Relacionadas a Cateter , Cateterismo Venoso Central , Cateterismo Periférico , Pontuação de Propensão , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Infecções Relacionadas a Cateter/epidemiologia , Infecções Relacionadas a Cateter/etiologia , Cateterismo Venoso Central/efeitos adversos , Cateterismo Venoso Central/métodos , Cateterismo Periférico/efeitos adversos , Idoso , Cateteres Venosos Centrais/efeitos adversos , Estudos de Coortes , Austrália/epidemiologia , Adulto , Cateteres de Demora/efeitos adversos , Remoção de Dispositivo/estatística & dados numéricos , Falha de Equipamento/estatística & dados numéricos
10.
Sci Rep ; 14(1): 11385, 2024 05 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762680

RESUMO

This article aims to report the comprehensive and up-to-date analysis and evidence of the insertion rate, expulsion rate, removal rate, and utilization rate of immediate placement of intrauterine devices (IUDs) versus delayed placement after artificial abortion. PubMed, Embase, Cochrane, Web of Science, CNKI, and Wanfang databases were comprehensively searched up to January 12, 2024 for studies that compared immediate versus delayed insertion of IUDs after abortion. The evaluation metrics included the number of IUD insertion after surgical or medical abortions, the frequency of expulsion and removal at 6 months or 1 year, the number of continued usage, pain intensity scores, the number of infections, the duration of bleeding, and instances of uterine perforation during or after IUD insertion. Ten randomized controlled articles were eligible, comprising 11 research projects, of which 3 projects involved the placement of an IUD after surgical abortion, and 8 projects involved the placement of an IUD after medical abortion. This included 2025 patients (977 in the immediate insertion group and 1,048 in the delayed insertion group). We summarized all the extracted evidence. The meta-analysis results indicated that for post-surgical abortions, the immediate insertion group exhibited a higher IUD placement rate than the delayed insertion group. After medical abortions, the immediate insertion group showed higher rates of IUD placement, utilization, and expulsion at 6 months or 1 year. The two groups showed no statistically significant differences in the removal rate, post-insertion infection rate, pain scores during insertion, and days of bleeding during the follow-up period. Compared to delayed placement, immediate insertion of IUDs can not only increase the usage rate at 6 months or 1 year but also enhance the placement rate.


Assuntos
Aborto Induzido , Dispositivos Intrauterinos , Humanos , Feminino , Dispositivos Intrauterinos/efeitos adversos , Aborto Induzido/efeitos adversos , Aborto Induzido/métodos , Gravidez , Fatores de Tempo , Remoção de Dispositivo
11.
Ann Plast Surg ; 92(6): 621-624, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38717197

RESUMO

ABSTRACT: The unique dual-lumen and baffle design of the IDEAL IMPLANT Structured Saline breast implant gives it specific advantages over both silicone gel-filled and the original saline-filled implants. This internal baffle structure also gives it an appearance on various radiologic imaging studies that may be misinterpreted as a rupture because of similarities to the well-known radiologic appearance of a ruptured silicone gel implant. Patients may present with various misinterpreted imaging studies, highlighting the need for plastic surgeons and radiologists to be familiar with the normal appearance of the intact IDEAL IMPLANT and be able to distinguish it from a ruptured IDEAL IMPLANT. The radiology findings must be correlated with the clinical findings, or an intact IDEAL IMPLANT misdiagnosed as ruptured, may cause unnecessary patient worry, and may prompt unnecessary surgery for removal or replacement.


Assuntos
Implantes de Mama , Remoção de Dispositivo , Erros de Diagnóstico , Falha de Prótese , Humanos , Implantes de Mama/efeitos adversos , Feminino , Procedimentos Desnecessários , Implante Mamário/efeitos adversos , Implante Mamário/métodos , Adulto , Desenho de Prótese , Géis de Silicone , Solução Salina , Pessoa de Meia-Idade
12.
BMC Womens Health ; 24(1): 301, 2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38769558

RESUMO

BACKGROUND: Successful efforts to encourage uptake of subdermal contraceptive implants, with a lifespan of three to five years, necessitate planning to ensure that quality removal services are available when desired. In Burkina Faso, implant use has tripled over the past 8 years and now comprises almost half of the contraceptive method mix. Population Monitoring for Action (PMA) surveys identified barriers to obtaining quality removal when desired, particularly when the implant is not palpable, or providers lack needed skills or supplies. The Expanding Family Planning Choices (EFPC) project supported ministries of health in four countries with evaluation and strengthening of implant removal services. METHODS: An implant removal landscape assessment was conducted at 24 health facilities in three regions of Burkina Faso with high implant use that included provider observations of implant removal, interviews with providers and health facility managers, and facility readiness surveys. The project used landscape data to mobilize stakeholders through a series of participatory workshops to develop a collaborative roadmap and commit to actions supporting quality implant removals. RESULTS: Landscape findings revealed key gaps in provision of quality removal services, including high levels of provider confidence for implant insertion and removal (82% and 71%, respectively), low competence performing simple and difficult removals (19.2% and 11.1%, respectively), inadequate supplies and equipment (no facilities had all necessary materials for removal), lack of difficult removal management systems, and a lack of standard data collection tools for removal. Exposure to the data convinced stakeholders to focus on removals rather than expanding insertion services. While not all roadmap commitments were achieved, the process led to critical investments in quality implant removals. CONCLUSION: Landscape data revealed that facilities lack needed supplies and equipment, and providers lack skills needed to perform quality implant removals, limiting client reproductive choice. Disseminating this data enabled stakeholders to identify and commit to evidence-based priority actions. Stakeholders have since capitalized on program learnings and the roadmap, including following MOH guidance for implant removal supplies and health provider training. Our experience in Burkina Faso offers a replicable model of how data can direct collective action to improve quality of contraceptive implant removals.


Assuntos
Remoção de Dispositivo , Burkina Faso , Humanos , Feminino , Remoção de Dispositivo/métodos , Implantes de Medicamento , Serviços de Planejamento Familiar/métodos , Participação dos Interessados , Anticoncepcionais Femininos , Instalações de Saúde/estatística & dados numéricos
13.
Port J Card Thorac Vasc Surg ; 31(1): 12-16, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38743522

RESUMO

There has been a worldwide rapid adoption of transcatheter aortic valve replacement (TAVR) as an alternative to surgical aortic valve replacement (SAVR) for patients with severe aortic stenosis. Currently, more TAVR explants with SAVRs are performed than TAVR-in TAV. TAVR explantation is a technically hazardous procedure mainly due to significant aortic neo-endothelialization which incorporates the TAVR valve. Surgical techniques for TAVR explantation are not well established and surgeon experience at present is limited. In this manuscript, we describe our technique for surgical explantation of transcatheter aortic bioprosthesis. Familiarity with the procedure and its clinical implications is essential for all cardiac surgeons.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Remoção de Dispositivo , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Valva Aórtica/cirurgia , Valva Aórtica/patologia , Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Remoção de Dispositivo/métodos , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação
15.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727126

RESUMO

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Assuntos
Fios Ortopédicos , Migração de Corpo Estranho , Olécrano , Osteotomia , Humanos , Fios Ortopédicos/efeitos adversos , Masculino , Pessoa de Meia-Idade , Olécrano/lesões , Olécrano/cirurgia , Olécrano/diagnóstico por imagem , Osteotomia/efeitos adversos , Osteotomia/métodos , Osteotomia/instrumentação , Migração de Corpo Estranho/cirurgia , Migração de Corpo Estranho/diagnóstico por imagem , Migração de Corpo Estranho/etiologia , Fraturas do Úmero/cirurgia , Fraturas do Úmero/diagnóstico por imagem , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Fixação Interna de Fraturas/instrumentação , Remoção de Dispositivo/métodos , Articulação do Cotovelo/cirurgia , Articulação do Cotovelo/diagnóstico por imagem , Fraturas Intra-Articulares/cirurgia , Fraturas Intra-Articulares/diagnóstico por imagem
16.
Jt Dis Relat Surg ; 35(2): 404-409, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38727121

RESUMO

OBJECTIVES: This study aimed to compare the course of anxiety change in children who used headphones during cast removal with controls in midterm follow-up. PATIENTS AND METHODS: Sixty-six patients who underwent forearm fracture treatment with closed reduction and long arm casting between June 2021 and March 2023 were retrospectively reviewed. Patients were divided into two groups based on the use of headphones (n=27; 21 males, 6 females; mean age: 8.0±1.8 years; range, 6 to 12 years) or not (n=39; 27 males, 12 females; mean age: 8.9±1.8 years; range, 6 to 12 years) during cast removal with an oscillating saw. Primary outcome measures included preprocedure, postprocedure, and six-month anxiety assessments with the State-Trait Anxiety Inventory. RESULTS: There was an acute increase in the mean state anxiety scores after the procedure, which returned to below baseline at the six-month follow-up in the headphone (31.4±8.3, 33.3±8.7, and 25.1±4.1, respectively) and control groups (34.9±11.1, 37.4±9.5, and 27.3±5.3, respectively). The mean trait anxiety scores before the procedure, after the procedure, and at six months remained similar in the headphone (33.6±3.0, 34.6±3.2, and 32.4±2.8; p>0.05) and control groups (34.1±2.7, 33.7±3.0, and 33.7±3.0, p>0.05). CONCLUSION: This study suggests that the acute anxiety during cast removal did not create anxiety sequelae in the sixth month regardless of headphone use.


Assuntos
Ansiedade , Moldes Cirúrgicos , Humanos , Feminino , Masculino , Criança , Estudos Retrospectivos , Ansiedade/psicologia , Ansiedade/etiologia , Remoção de Dispositivo/psicologia , Traumatismos do Antebraço/cirurgia , Traumatismos do Antebraço/psicologia , Redução Fechada/métodos
17.
Card Electrophysiol Clin ; 16(2): 125-132, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749630

RESUMO

The population of patients with advanced heart failure continues to increase steadily as does the need for mechanical circulatory support. Combination therapy with left ventricular assist devices (LVADs) and cardiovascular implantable electronic devices (CIEDs) is unavoidable. CIED complications in patients with LVADs are common and often necessitate device system revision and transvenous lead extraction. Despite this, management recommendations are limited, and guidelines are lacking.


Assuntos
Remoção de Dispositivo , Insuficiência Cardíaca , Coração Auxiliar , Humanos , Coração Auxiliar/efeitos adversos , Remoção de Dispositivo/métodos , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Desfibriladores Implantáveis/efeitos adversos
18.
Card Electrophysiol Clin ; 16(2): 139-142, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749632

RESUMO

This case report discusses a 42-year-old male with dextro-transposition of the great arteries (D-TGA) status post Mustard repair and sick sinus syndrome status post dual-chamber pacemaker implant, who developed symptomatic superior vena cava (SVC) baffle stenosis. He was treated with a combined pacemaker extraction and subsequent SVC baffle stenting. The case highlights the complexities of treating SVC baffle stenosis in the presence of cardiac implantable devices and demonstrates the efficacy of this combined approach. Furthermore, the authors delve into the intricacies of D-TGA, its surgical history, and the long-term complications associated with atrial switch procedures.


Assuntos
Remoção de Dispositivo , Marca-Passo Artificial , Stents , Transposição dos Grandes Vasos , Humanos , Transposição dos Grandes Vasos/cirurgia , Masculino , Adulto , Marca-Passo Artificial/efeitos adversos , Síndrome da Veia Cava Superior/cirurgia , Síndrome da Veia Cava Superior/etiologia , Síndrome do Nó Sinusal/terapia , Síndrome do Nó Sinusal/cirurgia
19.
Card Electrophysiol Clin ; 16(2): 143-147, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749633

RESUMO

We present a complex case of cardiac implantable electronic device infection and extraction in the setting of bacteremia, large lead vegetation, and patent foramen ovale. Following a comprehensive preprocedural workup including transesophageal echocardiogram and computed tomography lead extraction protocol, in addition to the involvement of multiple subspecialties, an open chest approach to extraction was deemed a safer option for eradication of the patient's infection. Despite percutaneous techniques having evolved as the preferred extraction method during the last few decades, this case demonstrates the importance of a thorough evaluation at an experienced center to determine the need for open chest extraction.


Assuntos
Desfibriladores Implantáveis , Remoção de Dispositivo , Marca-Passo Artificial , Infecções Relacionadas à Prótese , Humanos , Remoção de Dispositivo/métodos , Desfibriladores Implantáveis/efeitos adversos , Infecções Relacionadas à Prótese/cirurgia , Infecções Relacionadas à Prótese/diagnóstico por imagem , Marca-Passo Artificial/efeitos adversos , Masculino , Ecocardiografia Transesofagiana , Tomografia Computadorizada por Raios X , Idoso , Forame Oval Patente/cirurgia , Forame Oval Patente/diagnóstico por imagem , Feminino , Pessoa de Meia-Idade
20.
Card Electrophysiol Clin ; 16(2): 117-124, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38749629

RESUMO

Transvenous laser lead extraction poses a risk of major complications (0.19%-1.8%), notably injury to the superior vena cava (SVC) in 0.19% to 0.96% of cases. Various factors contribute to SVC injury, which can be categorized as patient-related (such as female gender, low body mass index, diabetes, renal problems, anemia, and reduced ejection fraction), device-related (including the number, dwell time, and type of leads), or procedural-related (such as reason for extraction, venous obstructions, and bilateral lead placements).


Assuntos
Remoção de Dispositivo , Terapia a Laser , Veia Cava Superior , Humanos , Veia Cava Superior/lesões , Veia Cava Superior/cirurgia , Feminino , Remoção de Dispositivo/efeitos adversos , Masculino , Terapia a Laser/efeitos adversos , Pessoa de Meia-Idade , Idoso , Desfibriladores Implantáveis/efeitos adversos , Marca-Passo Artificial/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA