Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 5.761
Filtrar
1.
Methods Mol Biol ; 2804: 3-50, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753138

RESUMO

Self-powered microfluidics presents a revolutionary approach to address the challenges of healthcare in decentralized and point-of-care settings where limited access to resources and infrastructure prevails or rapid clinical decision-making is critical. These microfluidic systems exploit physical and chemical phenomena, such as capillary forces and surface tension, to manipulate tiny volumes of fluids without the need for external power sources, making them cost-effective and highly portable. Recent technological advancements have demonstrated the ability to preprogram complex multistep liquid operations within the microfluidic circuit of these standalone systems, which enabled the integration of sensitive detection and readout principles. This chapter first addresses how the accessibility to in vitro diagnostics can be improved by shifting toward decentralized approaches like remote microsampling and point-of-care testing. Next, the crucial role of self-powered microfluidic technologies to enable this patient-centric healthcare transition is emphasized using various state-of-the-art examples, with a primary focus on applications related to biofluid collection and the detection of either proteins or nucleic acids. This chapter concludes with a summary of the main findings and our vision of the future perspectives in the field of self-powered microfluidic technologies and their use for in vitro diagnostics applications.


Assuntos
Técnicas Analíticas Microfluídicas , Ácidos Nucleicos , Sistemas Automatizados de Assistência Junto ao Leito , Proteínas , Humanos , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microfluídica/métodos , Microfluídica/instrumentação , Ácidos Nucleicos/análise , Testes Imediatos , Proteínas/análise
2.
Mikrochim Acta ; 191(5): 295, 2024 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-38700804

RESUMO

White blood cells (WBCs) are robust defenders during antigenic challenges and prime immune cell functioning indicators. High-purity WBC separation is vital for various clinical assays and disease diagnosis. Red blood cells (RBCs) are a major hindrance in WBC separation, constituting 1000 times the WBC population. The study showcases a low-cost micropump integrated microfluidic platform to provide highly purified WBCs for point-of-care testing. An integrated user-friendly microfluidic platform was designed to separate WBCs from finger-prick blood (⁓5 µL), employing an inertial focusing technique. We achieved an efficient WBC separation with 86% WBC purity and 99.99% RBC removal rate in less than 1 min. In addition, the microdevice allows lab-on-chip colorimetric evaluation of chronic granulomatous disease (CGD), a rare genetic disorder affecting globally. The assay duration, straight from separation to disease detection, requires only 20 min. Hence, the proposed microfluidic platform can further be implemented to streamline various clinical procedures involving WBCs in healthcare industries.


Assuntos
Separação Celular , Doença Granulomatosa Crônica , Dispositivos Lab-On-A-Chip , Leucócitos , Técnicas Analíticas Microfluídicas , Humanos , Doença Granulomatosa Crônica/diagnóstico , Doença Granulomatosa Crônica/sangue , Leucócitos/citologia , Separação Celular/instrumentação , Separação Celular/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
3.
PLoS One ; 19(5): e0295849, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696491

RESUMO

INTRODUCTION: Microfluidic resistive pulse sensing (MRPS) can determine the concentration and size distribution of extracellular vesicles (EVs) by measuring the electrical resistance of single EVs passing through a pore. To ensure that the sample flows through the pore, the sample needs to contain a wetting agent, such as bovine serum albumin (BSA). BSA leaves EVs intact but occasionally results in unstable MRPS measurements. Here, we aim to find a new wetting agent by evaluating Poloxamer-188 and Tween-20. METHODS: An EV test sample was prepared using an outdated erythrocyte blood bank concentrate. The EV test sample was diluted in Dulbecco's phosphate-buffered saline (DPBS) or DPBS containing 0.10% BSA (w/v), 0.050% Poloxamer-188 (v/v) or 1.00% Tween-20 (v/v). The effect of the wetting agents on the concentration and size distribution of EVs was determined by flow cytometry. To evaluate the precision of sample volume determination with MRPS, the interquartile range (IQR) of the particles transit time through the pore was examined. To validate that DPBS containing Poloxamer-188 yields reliable MRPS measurements, the repeatability of MRPS in measuring blood plasma samples was examined. RESULTS: Flow cytometry results show that the size distribution of EVs in Tween 20, in contrast to Poloxamer-188, differs from the control measurements (DPBS and DPBS containing BSA). MRPS results show that Poloxamer-188 improves the precision of sample volume determination compared to BSA and Tween-20, because the IQR of the transit time of EVs in the test sample is 11 µs, which is lower than 56 µs for BSA and 16 µs for Tween-20. Furthermore, the IQR of the transit time of particles in blood samples with Poloxamer-188 are 14, 16, and 14 µs, which confirms the reliability of MRPS measurements. CONCLUSION: The solution of 0.050% Poloxamer-188 in DPBS does not lyse EVs and results in repeatable and unimpeded MRPS measurements.


Assuntos
Vesículas Extracelulares , Poloxâmero , Poloxâmero/química , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/química , Humanos , Polissorbatos/química , Soroalbumina Bovina/química , Microfluídica/métodos , Molhabilidade , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Animais
4.
Anal Methods ; 16(19): 3007-3019, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38695537

RESUMO

We present a colorimetric probe based on polyvinylpyrrolidone-capped gold nanoparticles (PVP-AuNPs) that is sensitive and selective for cysteine (Cys). A microfluidic paper-based analytical device (µ-PAD) with embedded dried PVP-AuNPs at the polyethersulfone (PES) paper surface is used for Cys detection. When thiol molecules attach to PVP-AuNPs in the presence of Cys, they clump together, and this causes the solution's color to shift from red to blue within 5 minutes. The device is capable of detecting Cys levels between 1.0 µM and 50.0 µM with a limit of detection (LOD) of 0.2 µM under optimized conditions. The stability of the µ-PAD was tested for 100 days, demonstrating re-dispersibility to detect Cys levels in blood. Dried PVP-AuNP-µPADs were integrated with blood plasma separation modules for point-of-care (POC) Cys detection. Consequently, the device shows potential as a self-sustaining, quantification platform with a recovery percentage ranging from 98.44 to 111.9 in clinical samples.


Assuntos
Colorimetria , Cisteína , Ouro , Limite de Detecção , Nanopartículas Metálicas , Papel , Sistemas Automatizados de Assistência Junto ao Leito , Ouro/química , Cisteína/sangue , Cisteína/química , Nanopartículas Metálicas/química , Humanos , Colorimetria/métodos , Colorimetria/instrumentação , Povidona/química , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
5.
Nat Commun ; 15(1): 4363, 2024 May 22.
Artigo em Inglês | MEDLINE | ID: mdl-38778087

RESUMO

Drug screening based on in-vitro primary tumor cell culture has demonstrated potential in personalized cancer diagnosis. However, the limited number of tumor cells, especially from patients with early stage cancer, has hindered the widespread application of this technique. Hence, we developed a digital microfluidic system for drug screening using primary tumor cells and established a working protocol for precision medicine. Smart control logic was developed to increase the throughput of the system and decrease its footprint to parallelly screen three drugs on a 4 × 4 cm2 chip in a device measuring 23 × 16 × 3.5 cm3. We validated this method in an MDA-MB-231 breast cancer xenograft mouse model and liver cancer specimens from patients, demonstrating tumor suppression in mice/patients treated with drugs that were screened to be effective on individual primary tumor cells. Mice treated with drugs screened on-chip as ineffective exhibited similar results to those in the control groups. The effective drug identified through on-chip screening demonstrated consistency with the absence of mutations in their related genes determined via exome sequencing of individual tumors, further validating this protocol. Therefore, this technique and system may promote advances in precision medicine for cancer treatment and, eventually, for any disease.


Assuntos
Neoplasias da Mama , Microfluídica , Medicina de Precisão , Ensaios Antitumorais Modelo de Xenoenxerto , Medicina de Precisão/métodos , Humanos , Animais , Camundongos , Feminino , Linhagem Celular Tumoral , Microfluídica/métodos , Neoplasias da Mama/tratamento farmacológico , Neoplasias da Mama/genética , Neoplasias da Mama/patologia , Ensaios de Seleção de Medicamentos Antitumorais/métodos , Antineoplásicos/farmacologia , Antineoplásicos/uso terapêutico , Neoplasias Hepáticas/tratamento farmacológico , Neoplasias Hepáticas/genética , Dispositivos Lab-On-A-Chip , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
6.
Methods Mol Biol ; 2804: 77-89, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753141

RESUMO

Extracellular vesicles (EVs) are secreted by cells and found in biological fluids such as blood, with concentration correlated with oncogenic signals, making them attractive biomarkers for liquid biopsy. The current gold-standard method for EVs isolation requires an ultracentrifugation (UC) step among others. The cost and complexity of this technique are forbiddingly high for many researchers, as well as for routine use in biological laboratories and hospitals. This chapter reports on a simple microfluidic method for EVs isolation, based on a microfluidic size sorting technique named Deterministic Lateral Displacement (DLD). With the design of micrometric DLD array, we demonstrated the potential of our DLD devices for the isolation of nano-biological objects such as EVs, with main population size distribution consistent with UC technique.


Assuntos
Vesículas Extracelulares , Dispositivos Lab-On-A-Chip , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/química , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Cultura de Células/métodos , Ultracentrifugação/métodos
7.
Methods Mol Biol ; 2804: 91-100, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753142

RESUMO

Circulating tumor cells (CTCs) isolated directly from whole blood opens new perspectives for cancer monitoring and the development of personalized treatments. However, due to their rarity among the multitude of blood cells, it remains a challenge to recover them alive with high level of purity, i.e., with few remaining white blood cells, and in a time frame compatible with the clinical context. Microfluidic chips have emerged as promising tools to address these challenges. We propose a two-step workflow including a pre-enrichment step, performed by a size-based pre-enrichment system, and a purification step, performed by an immunomagnetic chip. Here, we describe the protocol for the fabrication of the immunomagnetic microchip, the preparation of the sample, and the procedure for injection into the microchip allowing the sorting of the CTCs.


Assuntos
Separação Imunomagnética , Dispositivos Lab-On-A-Chip , Células Neoplásicas Circulantes , Células Neoplásicas Circulantes/patologia , Separação Imunomagnética/métodos , Humanos , Separação Celular/métodos , Separação Celular/instrumentação , Neoplasias/patologia , Neoplasias/sangue , Linhagem Celular Tumoral , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos
8.
Methods Mol Biol ; 2804: 127-138, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753145

RESUMO

Within the vast field of medical biotechnology, the biopharmaceutical industry is particularly fast-growing and highly competitive, so reducing time and costs associated to process optimization becomes instrumental to ensure speed to market and, consequently, profitability. The manufacturing of biopharmaceutical products, namely, monoclonal antibodies (mAbs), relies mostly on mammalian cell culture processes, which are highly dynamic and, consequently, difficult to optimize. In this context, there is currently an unmet need of analytical methods that can be integrated at-line in a bioreactor, for systematic monitoring and quantification of key metabolites and proteins. Microfluidic-based assays have been extensively and successfully applied in the field of molecular diagnostics; however, this technology remains largely unexplored for Process Analytical Technology (PAT), despite holding great potential for the at-line measurement of different analytes in bioreactor processes, combining low reagent/molecule consumption with assay sensitivity and rapid turnaround times.Here, the fabrication and handling of a microfluidic cartridge for protein quantification using bead-based affinity assays is described. The device allows geometrical multiplexed immunodetection of specific protein analytes directly from bioreactor samples within 2.5 h and minimal hands-on time. As a proof-of-concept, quantification of Chinese hamster ovary (CHO) host cell proteins (HCP) as key impurities, IgG as product of interest, and lactate dehydrogenase (LDH) as cell viability marker was demonstrated with limits of detection (LoD) in the low ng/mL range. Negligible matrix interference and no cross-reactivity between the different immunoassays on chip were found. The results highlight the potential of the miniaturized analytical method for PAT at reduced cost and complexity in comparison with sophisticated instruments that are currently the state-of-the-art in this context.


Assuntos
Cricetulus , Células CHO , Animais , Anticorpos Monoclonais/imunologia , Reatores Biológicos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Imunoensaio/métodos , Imunoensaio/instrumentação , Microfluídica/métodos , Microfluídica/instrumentação , Cricetinae
9.
Methods Mol Biol ; 2804: 65-75, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753140

RESUMO

In recent years, the analysis of circulating cell-free DNA (cfDNA) containing tumor-derived DNA has emerged as a noninvasive means for cancer monitoring and personalized medicine. However, the isolation of cfDNA from peripheral blood has remained a challenge due to the low abundance and high fragmentation of these molecules. Here, we present a dynamic Magnetic ExTRactiOn (METRO) protocol using microfluidic fluidized bed technology to isolate circulating cfDNA from raw biological materials such as undiluted serum. This protocol maximizes the surface area for DNA binding within the chip in order to capture short DNA fragments. It uses only a few µL of sample and reagents. The protocol can be automated, and it is fully compatible with sensitive DNA amplification methods such as droplet-based digital PCR (ddPCR).


Assuntos
Ácidos Nucleicos Livres , Dispositivos Lab-On-A-Chip , Humanos , Ácidos Nucleicos Livres/isolamento & purificação , Ácidos Nucleicos Livres/sangue , Ácidos Nucleicos Livres/genética , Reação em Cadeia da Polimerase/métodos , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Magnetismo/métodos , Neoplasias/sangue , Neoplasias/genética , Neoplasias/diagnóstico
10.
Methods Mol Biol ; 2804: 141-162, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753146

RESUMO

Protein secretion is a key cellular functionality, particularly in immunology, where cells can display large heterogeneity in this crucial activity in addition to binary secretion behavior. However, few methods enable quantitative secretion rate measurements at the single-cell level, and these methods are mostly based on microfluidics systems. Here, we describe such a microfluidic single-cell method for precisely measuring protein secretion rates in detail, building on the published droplet-based microfluidic platform DropMap. We give an updated, detailed guide toward quantifying protein secretion rates, discussing its setup and limitations. We illustrate the protocol on two key immunological analytes, immunoglobulin G, and interferon-γ.


Assuntos
Interferon gama , Análise de Célula Única , Análise de Célula Única/métodos , Humanos , Interferon gama/metabolismo , Imunoglobulina G/metabolismo , Proteínas/metabolismo , Técnicas Analíticas Microfluídicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Microfluídica/métodos , Microfluídica/instrumentação
11.
Methods Mol Biol ; 2804: 103-115, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753143

RESUMO

In this chapter, we present the design and fabrication of a device and implementation of a protocol to realize increased efficiency of immunoassays within microtiter plates. The device, WellProbe, is a 3D-structured probe that can be used to deliver precise flows at the bottom of standard well plates to establish concentric areas of shear stress intensities using hydrodynamically confined flows. The protocols involve both operation and data analysis.


Assuntos
Desenho de Equipamento , Imunoensaio/métodos , Imunoensaio/instrumentação , Hidrodinâmica , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Humanos
12.
Methods Mol Biol ; 2804: 179-194, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753148

RESUMO

Antibiotic susceptibility testing (AST) is a routine procedure in diagnostic laboratories to determine pathogen resistance profiles toward antibiotics. The need for fast and accurate resistance results is rapidly increasing with a global rise in pathogen antibiotic resistance over the past years. Microfluidic technologies can enable AST with lower volumes, lower cell numbers, and a reduction in the sample-to-result time compared to state-of-the-art systems. We present a protocol to perform AST on a miniaturized nanoliter chamber array platform. The chambers are filled with antibiotic compounds and oxygen-sensing nanoprobes that serve as a viability indicator. The growth of bacterial cells in the presence of different concentrations of antibiotics is monitored; living cells consume oxygen, which can be observed as an increase of a luminesce signal within the growth chambers. Here, we demonstrate the technique using a quality control Escherichia coli strain, ATCC 35218. The AST requires 20 µL of a diluted bacterial suspension (OD600 = 0.02) and provides resistance profiles about 2-3 h after the inoculation. The microfluidic method can be adapted to other aerobic pathogens and is of particular interest for slow-growing strains.


Assuntos
Antibacterianos , Escherichia coli , Testes de Sensibilidade Microbiana , Testes de Sensibilidade Microbiana/métodos , Testes de Sensibilidade Microbiana/instrumentação , Antibacterianos/farmacologia , Escherichia coli/efeitos dos fármacos , Escherichia coli/crescimento & desenvolvimento , Escherichia coli/metabolismo , Consumo de Oxigênio/efeitos dos fármacos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Oxigênio/metabolismo , Dispositivos Lab-On-A-Chip
13.
Methods Mol Biol ; 2804: 223-235, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753151

RESUMO

Reliable predictions for the route and accumulation of nanotherapeutics in vivo are limited by the huge gap between the 2D in vitro assays used for drug screening and the 3D physiological in vivo environment. While developing a standard 3D in vitro model for screening nanotherapeutics remains challenging, multi-cellular tumor spheroids (MCTS) are a promising in vitro model for such screening. Here, we present a straightforward and flexible 3D-model microsystem made out of agarose-based micro-wells, which enables the formation of hundreds of reproducible spheroids in a single pipetting. Immunostaining and fluorescent imaging, including live high-resolution optical microscopy, can be done in situ without manipulating spheroids.


Assuntos
Hidrogéis , Nanopartículas , Esferoides Celulares , Humanos , Nanopartículas/química , Hidrogéis/química , Linhagem Celular Tumoral , Microfluídica/métodos , Microfluídica/instrumentação , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Microscopia de Fluorescência/métodos
14.
Methods Mol Biol ; 2804: 163-176, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753147

RESUMO

Multiomics studies at single-cell level require small volume manipulation, high throughput analysis, and multiplexed detection, characteristics that droplet microfluidics can tackle. However, the initial step of molecule bioseparation remains challenging. Here, we describe a unique magnetic device to trap and extract magnetic particles in sub-nanoliter droplets, for compartmentalisation of detection steps. Relying on electrodeposition of NiFe structures and microfluidic manipulation, the extraction of 1 µm diameter magnetic particles was achieved at high throughput (20 droplets per second) with an efficiency close to 100% in 450 pL droplets. The first demonstration of its adaptability to single-cell analysis is demonstrated with the extraction of mRNA. Using a purified nucleic acid solution, this unique magnetic configuration was able to reach a RNA extraction rate of 72%. This is the first demonstration of a physical separation in droplets at high throughput at single-cell scale.


Assuntos
Análise de Célula Única , Análise de Célula Única/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Ensaios de Triagem em Larga Escala/métodos , Magnetismo/métodos , RNA Mensageiro/genética , RNA Mensageiro/isolamento & purificação , Humanos , Microfluídica/métodos , Microfluídica/instrumentação
15.
Methods Mol Biol ; 2804: 237-251, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753152

RESUMO

Organ-on-a-chip technology allows researchers to precisely monitor drug efficacy in 3D tissue culture systems that are physiologically more relevant to humans compared to 2D cultures and that allow better control over experimental conditions as compared to animal models. Specifically, the high control over microenvironmental conditions combined with the broad range of direct measurements that can be performed in these systems makes organ-on-a-chip devices a versatile tool to investigate tumor targeting and drug delivery. Here, we describe a detailed protocol for studying the cell-selective targeting of protein drugs to tumor cells on an organ-on-a-chip system using a co-culture consisting of BT-474 cancer cells and C5120 human fibroblasts as an example.


Assuntos
Técnicas de Cocultura , Dispositivos Lab-On-A-Chip , Humanos , Técnicas de Cocultura/métodos , Linhagem Celular Tumoral , Fibroblastos/metabolismo , Microambiente Tumoral , Neoplasias/patologia , Neoplasias/tratamento farmacológico , Sistemas de Liberação de Medicamentos/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Antineoplásicos/farmacologia , Microfluídica/métodos , Microfluídica/instrumentação
16.
Methods Mol Biol ; 2804: 209-221, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38753150

RESUMO

Microfluidic-based cytotoxic assays provide high physiological relevance with the potential to replace conventional animal experiments and two-dimensional (2D) assays. Here, a 3D method utilizing a microfluidic platform for analysis of lymphocyte cytotoxicity is introduced in detail, including platform design, cell culture method, real-time cytotoxic assay setup, and image-based analysis. A 2D experimental method is used for comparison, which effectively demonstrates the advantages of 3D microfluidic platforms in closely recapitulating immune responses within the tumor microenvironment. Moreover, a wide range of experimental possibilities and applications using microfluidic 3D cytotoxic assays is introduced in this chapter, along with their capabilities, limitations, and future outlook.


Assuntos
Técnicas Analíticas Microfluídicas , Humanos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Cultura de Células/métodos , Técnicas de Cultura de Células/instrumentação , Testes Imunológicos de Citotoxicidade/métodos , Microfluídica/métodos , Microfluídica/instrumentação , Animais , Linfócitos/imunologia , Linfócitos/citologia , Microambiente Tumoral/imunologia
17.
Nat Commun ; 15(1): 4109, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38750038

RESUMO

Label-free detection of multiple analytes in a high-throughput fashion has been one of the long-sought goals in biosensing applications. Yet, for all-optical approaches, interfacing state-of-the-art label-free techniques with microfluidics tools that can process small volumes of sample with high throughput, and with surface chemistry that grants analyte specificity, poses a critical challenge to date. Here, we introduce an optofluidic platform that brings together state-of-the-art digital holography with PDMS microfluidics by using supported lipid bilayers as a surface chemistry building block to integrate both technologies. Specifically, this platform fingerprints heterogeneous biological nanoparticle populations via a multiplexed label-free immunoaffinity assay with single particle sensitivity. First, we characterise the robustness and performance of the platform, and then apply it to profile four distinct ovarian cell-derived extracellular vesicle populations over a panel of surface protein biomarkers, thus developing a unique biomarker fingerprint for each cell line. We foresee that our approach will find many applications where routine and multiplexed characterisation of biological nanoparticles are required.


Assuntos
Nanopartículas , Humanos , Nanopartículas/química , Bicamadas Lipídicas/química , Holografia/métodos , Vesículas Extracelulares/metabolismo , Vesículas Extracelulares/química , Microfluídica/métodos , Microfluídica/instrumentação , Feminino , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Linhagem Celular Tumoral , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Biomarcadores/análise
18.
ACS Sens ; 9(5): 2695-2702, 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38747895

RESUMO

Quantitative nucleic acid amplification tests are of great importance for diagnostics, but current approaches require complex and costly optical setups that limit their nonlaboratory applications. Herein we describe the implementation of a microfluidics platform that can perform binary DNA-amplification-activated droplet sorting. The digital sort-enabled counting (DISCO) platform enables label-free absolute quantification of the nucleic acid. This is achieved by provoking a pH change in droplets through a loop-mediated isothermal amplification (LAMP) reaction, followed by using sorting by interfacial tension (SIFT) to direct positive and negative droplets to different outlets. With the use of on-chip electrodes at both outlets, we demonstrate that the digital electrical counting of target DNA and RNA can be realized. DISCO is a promising approach for realizing sensitive nucleic acid quantification in point-of-care settings.


Assuntos
Técnicas de Amplificação de Ácido Nucleico , Técnicas de Amplificação de Ácido Nucleico/métodos , DNA/análise , DNA/química , Dispositivos Lab-On-A-Chip , RNA/análise , Eletrodos , Técnicas Eletroquímicas/métodos , Técnicas Analíticas Microfluídicas/instrumentação , Técnicas Analíticas Microfluídicas/métodos , Técnicas de Diagnóstico Molecular
19.
Anal Methods ; 16(15): 2368-2377, 2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38572530

RESUMO

Microfluidic technology has great advantages in the precise manipulation of micro-nano particles, and the hybrid microfluidic separation technology has attracted much attention due to the advantages of both active and passive separation technology at the same time. In this paper, the hydrophoresis sorting technique is combined with the dielectrophoresis technique, and a dielectrophoresis-assisted hydrophoresis microdevice is studied to separate blood cells. By using the dielectrophoresis force to change the suspension position of the cells in the channel, the scope of the hydrophoresis device for sorting particles is expanded. At the same time, the effects of microchannel width, fluid velocity, and electrode voltage on cell sorting were discussed, and the cell separation process was simulated. This work has laid a certain theoretical foundation for the rapid diagnosis of diseases in practical applications.


Assuntos
Técnicas Analíticas Microfluídicas , Técnicas Analíticas Microfluídicas/métodos , Simulação por Computador , Microfluídica , Eletroforese/métodos , Separação Celular/métodos
20.
Anal Chem ; 96(15): 5815-5823, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38575144

RESUMO

Microfluidic techniques are widely applied in biomolecular analysis and disease diagnostic assays. While the volume of the sample that is directly used in such assays is often only femto-to microliters, the "dead volume" of solutions supplied in syringes and tubing can be much larger, even up to milliliters, increasing overall reagent use and making analysis significantly more expensive. To reduce the difficulty and cost, we designed a new chip using a low volume solution for analysis and applied it to obtain real-time data for protein-protein interaction measurements. The chip takes advantage of air/aqueous two-phase droplet flow, on-chip rapid mixing within milliseconds, and a droplet capture method, that ultimately requires only 2 µL of reagent solution. The interaction is analyzed by particle diffusometry, a nonintrusive and precise optical detection method to analyze the properties of microparticle diffusion in solution. Herein, we demonstrate on-chip characterization of human immunodeficiency virus p24 antibody-antigen protein binding kinetics imaged via fluorescence microscopy and analyzed by PD. The measured kon and koff are 1 × 106 M-1 s-1 and 3.3 × 10-4 s-1, respectively, and agree with independent measurement via biolayer interferometry and previously calculated p24-antibody binding kinetics. This new microfluidic chip and the protein-protein interaction analysis method can also be applied in other fields that require low-volume solutions to perform accurate measurement, analysis, and detection.


Assuntos
Técnicas Analíticas Microfluídicas , Microfluídica , Humanos , Cinética , Difusão , Indicadores e Reagentes , Técnicas Analíticas Microfluídicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA