Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 3.245
Filtrar
1.
Sci Rep ; 14(1): 10597, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719924

RESUMO

Parotid lumps are a heterogeneous group of mainly benign but also malignant tumors. Preoperative imaging does not allow a differentiation between tumor types. Multispectral optoacoustic tomography (MSOT) may improve the preoperative diagnostics. In this first prospective pilot trial the ability of MSOT to discriminate between the two most frequent benign parotid tumors, pleomorphic adenoma (PA) and Warthin tumor (WT) as well as to normal parotid tissue was explored. Six wavelengths (700, 730, 760, 800, 850, 900 nm) and the parameters deoxygenated (HbR), oxygenated (HbO2), total hemoglobin (HbT), and saturation of hemoglobin (sO2) were analyzed. Ten patients with PA and fourteen with WT were included (12/12 female/male; median age: 51 years). For PA, the mean values for all measured wave lengths as well as for the hemoglobin parameters were different for the tumors compared to the healthy parotid (all p < 0.05). The mean MSOT parameters were all significantly higher (all p < 0.05) in the WT compared to healthy parotid gland except for HbT and sO2. Comparing both tumors directly, the mean values of MSOT parameters were not different between PA and WT (all p > 0.05). Differences were seen for the maximal MSOT parameters. The maximal tumor values for 900 nm, HbR, HbT, and sO2 were lower in PA than in WT (all p < 0.05). This preliminary MSOT parotid tumor imaging study showed clear differences for PA or WT compared to healthy parotid tissue. Some MSOT characteristics of PA and WT were different but needed to be explored in larger studies.


Assuntos
Neoplasias Parotídeas , Técnicas Fotoacústicas , Humanos , Feminino , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Parotídeas/patologia , Pessoa de Meia-Idade , Masculino , Projetos Piloto , Estudos Prospectivos , Técnicas Fotoacústicas/métodos , Adulto , Idoso , Hemoglobinas/análise , Hemoglobinas/metabolismo , Adenolinfoma/diagnóstico por imagem , Adenolinfoma/patologia , Adenoma Pleomorfo/diagnóstico por imagem , Adenoma Pleomorfo/patologia , Tomografia/métodos , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/patologia
2.
Opt Lett ; 49(10): 2637-2640, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38748124

RESUMO

Optical-resolution photoacoustic microscopy (OR-PAM) excels in precisely imaging a biological tissue based on absorption contrast. However, existing OR-PAMs are confined by fixed compromises between spatial resolution and field of view (FOV), preventing the integration of large FOV and local high-resolution within one system. Here, we present a non-telecentric OR-PAM (nTC-PAM) that empowers efficient adaptation of FOV and spatial resolution to match the multi-scale requirement of diverse biological imaging. Our method allows for a large-scale transformation in FOV and even surpassing the nominal FOV of the objective with minimal marginal degradation of the lateral resolution. We demonstrate the advantage of nTC-PAM through multi-scale imaging of the leaf phantom, mouse ear, and cortex. The results reveal that nTC-PAM can switch the FOV and spatial resolution to meet the requirements of different biological tissues, such as large-scale imaging of the whole cerebral cortex and high-resolution imaging of microvascular structures in local brain regions.


Assuntos
Microscopia , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Microscopia/métodos , Orelha/diagnóstico por imagem , Orelha/irrigação sanguínea , Imagens de Fantasmas
3.
Opt Lett ; 49(9): 2341-2344, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38691714

RESUMO

In the fields of biomedicine and microfluidics, the non-contact capture, manipulation, and spin of micro-particles hold great importance. In this study, we propose a programmable non-contact manipulation technique that utilizes photoacoustic effect to spin and transport living shrimp eggs. By directing a modulated pulsed laser toward a liquid-covered stainless-steel membrane, we can excite patterned Lamb waves within the membrane. These Lamb waves occur at the interface between the membrane and the liquid, enabling the manipulation of nearby particles. Experimental results demonstrate the successful capture, spin, and transport of shrimp eggs in diameter of 220 µm over a distance of about 5 mm. Calculations indicate that the acoustic radiation force and torque generated by our photoacoustic manipulation system are more than 299.5 nN and 41.0 nN·mm, respectively. The system surpasses traditional optical tweezers in terms of force and traditional acoustic tweezers in terms of flexibility. Consequently, this non-contact manipulation system significantly expands the possibilities for applications in various fields, including embryo screening, cell manipulation, and microfluidics.


Assuntos
Óvulo , Técnicas Fotoacústicas , Animais , Técnicas Fotoacústicas/métodos , Pressão , Pinças Ópticas , Penaeidae
4.
Sensors (Basel) ; 24(9)2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38732775

RESUMO

Photoacoustic imaging (PAI) is a rapidly developing emerging non-invasive biomedical imaging technique that combines the strong contrast from optical absorption imaging and the high resolution from acoustic imaging. Abnormal biological tissues (such as tumors and inflammation) generate different levels of thermal expansion after absorbing optical energy, producing distinct acoustic signals from normal tissues. This technique can detect small tissue lesions in biological tissues and has demonstrated significant potential for applications in tumor research, melanoma detection, and cardiovascular disease diagnosis. During the process of collecting photoacoustic signals in a PAI system, various factors can influence the signals, such as absorption, scattering, and attenuation in biological tissues. A single ultrasound transducer cannot provide sufficient information to reconstruct high-precision photoacoustic images. To obtain more accurate and clear image reconstruction results, PAI systems typically use a large number of ultrasound transducers to collect multi-channel signals from different angles and positions, thereby acquiring more information about the photoacoustic signals. Therefore, to reconstruct high-quality photoacoustic images, PAI systems require a significant number of measurement signals, which can result in substantial hardware and time costs. Compressed sensing is an algorithm that breaks through the Nyquist sampling theorem and can reconstruct the original signal with a small number of measurement signals. PAI based on compressed sensing has made breakthroughs over the past decade, enabling the reconstruction of low artifacts and high-quality images with a small number of photoacoustic measurement signals, improving time efficiency, and reducing hardware costs. This article provides a detailed introduction to PAI based on compressed sensing, such as the physical transmission model-based compressed sensing method, two-stage reconstruction-based compressed sensing method, and single-pixel camera-based compressed sensing method. Challenges and future perspectives of compressed sensing-based PAI are also discussed.


Assuntos
Algoritmos , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Humanos , Processamento de Imagem Assistida por Computador/métodos , Diagnóstico por Imagem/métodos , Transdutores
5.
Biomacromolecules ; 25(5): 3153-3162, 2024 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-38693895

RESUMO

A photoacoustic (PA) imaging technique using the second near-infrared (NIR-II) window has attracted more and more attention because of its merits of deeper penetration depth and higher signal-to-noise (S/N) ratio than that using the first near-infrared (NIR-I) one. However, the design and development of high-performance PA imaging contrast agents in the NIR-II window is still a challenge. A semiconducting polymer, constructed by asymmetric units, exhibits regiorandom characteristics that effectively increase the distortion of the backbone. This increase in the degree of twist can regulate the twisted intramolecular charge transfer (TICT) effect, resulting in an enhancement of the PA signal. In this paper, an asymmetric structural acceptor strategy is developed to improve the PA signals of the resulting semiconducting polymer (PATQ-MP) in the NIR-II window with improved brightness, higher S/N ratio, and better photothermal conversion efficiency compared to polymers with the same main-chain structure containing a symmetric acceptor. DFT analysis showed that PATQ-MP containing an asymmetric acceptor monomer had a larger dihedral angle, which effectively improved the PA signal intensity by enhancing the TICT effect. The PEG-encapsulated PATQ-MP nanoparticles exhibit promising performance in the PA imaging of mouse tumors in vivo, demonstrating the clear identification of microvessels as small as 100 µm along with rapid metabolism within a span of 5 h. Therefore, this work provides a unique molecular design strategy for improving the signal intensity of PA imaging in the NIR-II window.


Assuntos
Técnicas Fotoacústicas , Polímeros , Semicondutores , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Polímeros/química , Quinoxalinas/química , Feminino , Humanos , Tiadiazóis/química , Raios Infravermelhos , Camundongos Nus , Camundongos Endogâmicos BALB C , Meios de Contraste/química
6.
Lasers Med Sci ; 39(1): 112, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38656634

RESUMO

PURPOSE: To measure the dynamic characteristics of the flow field in a complex root canal model activated by two laser-activated irrigation (LAI) modalities at different activation energy outputs: photon-induced photoacoustic streaming (PIPS) and microshort pulse (MSP). METHODS: A phase-locked micro-scale Particle Image Velocimetry (µPIV) system was employed to characterise the temporal variations of LAI-induced velocity fields in the root canal following a single laser pulse. The wall shear stress (WSS) in the lateral root canal was subsequently estimated from the phase-averaged velocity fields. RESULTS: Both PIPS and MSP were able to generate the 'breath mode' of the irrigant current under all tested conditions. The transient irrigation flush in the root canal peaked at speeds close to 6 m/s. However, this intense flushing effect persisted for only about 2000 µs (or 3% of a single laser-pulse activation cycle). For MSP, the maximum WSS magnitude was approximately 3.08 Pa at an activation energy of E = 20 mJ/pulse, rising to 9.01 Pa at E = 50 mJ/pulse. In comparison, PIPS elevated the WSS to 10.63 Pa at E = 20 mJ/pulse. CONCLUSION: Elevating the activation energy can boost the peak flushing velocity and the maximum WSS, thereby enhancing irrigation efficiency. Given the same activation energy, PIPS outperforms MSP. Additionally, increasing the activation frequency may be an effective strategy to improve irrigation performance further.


Assuntos
Reologia , Humanos , Cavidade Pulpar/efeitos da radiação , Irrigação Terapêutica/métodos , Irrigação Terapêutica/instrumentação , Lasers , Irrigantes do Canal Radicular , Técnicas Fotoacústicas/métodos , Preparo de Canal Radicular/métodos , Preparo de Canal Radicular/instrumentação
7.
Anal Chem ; 96(18): 7248-7256, 2024 May 07.
Artigo em Inglês | MEDLINE | ID: mdl-38655839

RESUMO

Ferroptosis modulation is a powerful therapeutic option for pancreatic ductal adenocarcinoma (PDAC) with a low 5-year survival rate and lack of effective treatment methods. However, due to the dual role of ferroptosis in promoting and inhibiting pancreatic tumorigenesis, regulating the degree of ferroptosis is very important to obtain the best therapeutic effect of PDAC. Biothiols are suitable as biomarkers of imaging ferroptosis due to the dramatic decreases of biothiol levels in ferroptosis caused by the inhibited synthesis pathway of glutathione (GSH) and the depletion of biothiol by reactive oxygen species. Moreover, a very recent study reported that cysteine (Cys) depletion can lead to pancreatic tumor ferroptosis in mice and may be employed as an effective therapeutic strategy for PDAC. Therefore, visualization of biothiols in ferroptosis of PDAC will be helpful for regulating the degree of ferroptosis, understanding the mechanism of Cys depletion-induced pancreatic tumor ferroptosis, and further promoting the study and treatment of PDAC. Herein, two biothiol-activable near-infrared (NIR) fluorescent/photoacoustic bimodal imaging probes (HYD-BX and HYD-DX) for imaging of pancreatic tumor ferroptosis were reported. These two probes show excellent bimodal response performances for biothiols in solution, cells, and tumors. Subsequently, they have been employed successfully for real-time visualization of changes in concentration levels of biothiols during the ferroptosis process in PDAC cells and HepG2 cells. Most importantly, they have been further applied for bimodal imaging of ferroptosis in pancreatic cancer in mice, with satisfactory results. The development of these two probes provides new tools for monitoring changes in concentration levels of biothiols in ferroptosis and will have a positive impact on understanding the mechanism of Cys depletion-induced pancreatic tumor ferroptosis and further promoting the study and treatment of PDAC.


Assuntos
Ferroptose , Corantes Fluorescentes , Imagem Óptica , Neoplasias Pancreáticas , Técnicas Fotoacústicas , Neoplasias Pancreáticas/diagnóstico por imagem , Neoplasias Pancreáticas/metabolismo , Neoplasias Pancreáticas/patologia , Humanos , Corantes Fluorescentes/química , Animais , Camundongos , Compostos de Sulfidrila/química , Compostos de Sulfidrila/metabolismo , Raios Infravermelhos , Carcinoma Ductal Pancreático/diagnóstico por imagem , Carcinoma Ductal Pancreático/metabolismo , Carcinoma Ductal Pancreático/patologia
8.
Anal Chem ; 96(19): 7342-7347, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38683890

RESUMO

Photoacoustic (PA) tomography has shown many promising aspects in noninvasive and precise imaging of deep-localized biomarkers. However, these traditional single-locked PA probes always face challenges in precise PA imaging with high specificity. Here, we report a novel AND-gate photoacoustic probe, BAE, to improve tumor imaging accuracy via the combination of two tumor-associated biomarkers, cysteine (Cys) and hydrogen sulfide (H2S). Only when Cys and H2S are concurrently introduced into the detection system does the absorption of BAE red-shift from the initial 680 to 810 nm, thereby showing a 5.29-fold enhancement in its PA signal at 810 nm. The good specificity of BAE is proven, since an obvious PA signal could be observed only in the solution containing both Cys and H2S and was not affected by other reactive sulfur species. After being taken up by tumors with the assistance of a nanomicelle, the AND-gate PA probe BAE was applied for dynamic real-time monitoring of Cys and H2S in vivo, achieving precise identification of tumors. This AND-gate PA probe provides a potential technical tool for precise sensing analysis of deep-seated diseases.


Assuntos
Cisteína , Sulfeto de Hidrogênio , Técnicas Fotoacústicas , Sulfeto de Hidrogênio/análise , Técnicas Fotoacústicas/métodos , Cisteína/análise , Cisteína/química , Animais , Humanos , Camundongos , Neoplasias/diagnóstico por imagem , Camundongos Nus , Camundongos Endogâmicos BALB C
9.
J Hazard Mater ; 470: 134275, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38613954

RESUMO

Palladium contaminants can pose risks to human health and the natural environment. Once Pd2+ enters the body, it can bind with DNA, proteins, and other macromolecules, disrupting cellular processes and causing serious harm to health. Therefore, it becomes critical to develop simple, highly selective and precise methods for detecting Pd2+in vivo. Here, we have successfully developed the first activated second near-infrared region fluorescence (NIR-II FL) and ratio photoacoustic (PA) probe NYR-1 for dual-modal accurate detection of Pd2+ levels. NYR-1 is capable of rapidly (< 60 s) and sensitively detection of Pd2+ in solution, providing switched on NIR-II FL920 and ratio PA808/PA720 dual-mode signal change. More notably, the probe NYR-1 was successfully used for non-invasive imaging of Pd2+ overload in mouse liver by NIR-II FL/Ratio PA dual-modality imaging technology for the first time. Thus, this work opens up a promising dual-modal detection method for the precise detection of Pd2+ in organisms and in the environment.


Assuntos
Corantes Fluorescentes , Fígado , Paládio , Técnicas Fotoacústicas , Paládio/química , Animais , Fígado/diagnóstico por imagem , Fígado/metabolismo , Técnicas Fotoacústicas/métodos , Corantes Fluorescentes/química , Camundongos , Imagem Óptica , Raios Infravermelhos , Camundongos Endogâmicos BALB C , Fluorescência
10.
J Biomed Opt ; 29(Suppl 1): S11530, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38632983

RESUMO

Significance: In the photoacoustic (PA) technique, the laser irradiation in the time domain (i.e., laser pulse duration) governs the characteristics of PA imaging-it plays a crucial role in the optical-acoustic interaction, the generation of PA signals, and the PA imaging performance. Aim: We aim to provide a comprehensive analysis of the impact of laser pulse duration on various aspects of PA imaging, encompassing the signal-to-noise ratio, the spatial resolution of PA imaging, the acoustic frequency spectrum of the acoustic wave, the initiation of specific physical phenomena, and the photothermal-PA (PT-PA) interaction/conversion. Approach: By surveying and reviewing the state-of-the-art investigations, we discuss the effects of laser pulse duration on the generation of PA signals in the context of biomedical PA imaging with respect to the aforementioned aspects. Results: First, we discuss the impact of laser pulse duration on the PA signal amplitude and its correlation with the lateral resolution of PA imaging. Subsequently, the relationship between the axial resolution of PA imaging and the laser pulse duration is analyzed with consideration of the acoustic frequency spectrum. Furthermore, we examine the manipulation of the pulse duration to trigger physical phenomena and its relevant applications. In addition, we elaborate on the tuning of the pulse duration to manipulate the conversion process and ratio from the PT to PA effect. Conclusions: We contribute to the understanding of the physical mechanisms governing pulse-width-dependent PA techniques. By gaining insight into the mechanism behind the influence of the laser pulse, we can trigger the pulse-with-dependent physical phenomena for specific PA applications, enhance PA imaging performance in biomedical imaging scenarios, and modulate PT-PA conversion by tuning the pulse duration precisely.


Assuntos
Luz , Técnicas Fotoacústicas , Análise Espectral , Razão Sinal-Ruído , Acústica , Lasers , Técnicas Fotoacústicas/métodos
11.
ACS Sens ; 9(4): 2166-2175, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38625680

RESUMO

Relying on the strong optical absorption of hemoglobin to pulsed laser energy, photoacoustic microscopy provides morphological and functional information on microvasculature label-freely. Here, we propose speckle variance photoacoustic microscopy (SV-PAM), which harnesses intrinsic imaging contrast from temporal-varied photoacoustic signals of moving red blood cells in blood vessels, for recovering three-dimension hemodynamic images down to capillary-level resolution within the microcirculatory tissue beds in vivo. Calculating the speckle variance of consecutive photoacoustic B-scan frames acquired at the same lateral position enables accurate identification of blood perfusion and occlusion, which provides interpretations of dynamic blood flow in the microvasculature, in addition to the microvascular anatomic structures. We demonstrate high-resolution hemodynamic imaging of vascular occlusion and reperfusion in the microvasculature of mice ears in vivo. The results suggest that our SV-PAM is potentially invaluable for biomedical hemodynamic investigations, for example, imaging ischemic stroke and hemorrhagic stroke.


Assuntos
Microscopia , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Microscopia/métodos , Hemodinâmica/fisiologia , Orelha/irrigação sanguínea , Orelha/diagnóstico por imagem , Microvasos/diagnóstico por imagem , Eritrócitos , Microcirculação
12.
Opt Lett ; 49(7): 1725-1728, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38560847

RESUMO

Ultrasound coupling is one of the critical challenges for traditional photoacoustic (or optoacoustic) microscopy (PAM) techniques transferred to the clinical examination of chronic wounds and open tissues. A promising alternative potential solution for breaking the limitation of ultrasound coupling in PAM is photoacoustic remote sensing (PARS), which implements all-optical non-interferometric photoacoustic measurements. Functional imaging of PARS microscopy was demonstrated from the aspects of histopathology and oxygen metabolism, while its performance in hemodynamic quantification remains unexplored. In this Letter, we present an all-optical thermal-tagging flowmetry approach for PARS microscopy and demonstrate it with comprehensive mathematical modeling and ex vivo and in vivo experimental validations. Experimental results demonstrated that the detectable range of the blood flow rate was from 0 to 12 mm/s with a high accuracy (measurement error:±1.2%) at 10-kHz laser pulse repetition rate. The proposed all-optical thermal-tagging flowmetry offers an effective alternative approach for PARS microscopy realizing non-contact dye-free hemodynamic imaging.


Assuntos
Técnicas Fotoacústicas , Tecnologia de Sensoriamento Remoto , Técnicas Fotoacústicas/métodos , Reologia/métodos , Ultrassonografia/métodos , Microscopia/métodos
13.
J Biomed Opt ; 29(Suppl 1): S11529, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38650979

RESUMO

Significance: Compressed sensing (CS) uses special measurement designs combined with powerful mathematical algorithms to reduce the amount of data to be collected while maintaining image quality. This is relevant to almost any imaging modality, and in this paper we focus on CS in photoacoustic projection imaging (PAPI) with integrating line detectors (ILDs). Aim: Our previous research involved rather general CS measurements, where each ILD can contribute to any measurement. In the real world, however, the design of CS measurements is subject to practical constraints. In this research, we aim at a CS-PAPI system where each measurement involves only a subset of ILDs, and which can be implemented in a cost-effective manner. Approach: We extend the existing PAPI with a self-developed CS unit. The system provides structured CS matrices for which the existing recovery theory cannot be applied directly. A random search strategy is applied to select the CS measurement matrix within this class for which we obtain exact sparse recovery. Results: We implement a CS PAPI system for a compression factor of 4:3, where specific measurements are made on separate groups of 16 ILDs. We algorithmically design optimal CS measurements that have proven sparse CS capabilities. Numerical experiments are used to support our results. Conclusions: CS with proven sparse recovery capabilities can be integrated into PAPI, and numerical results support this setup. Future work will focus on applying it to experimental data and utilizing data-driven approaches to enhance the compression factor and generalize the signal class.


Assuntos
Algoritmos , Desenho de Equipamento , Processamento de Imagem Assistida por Computador , Técnicas Fotoacústicas , Técnicas Fotoacústicas/métodos , Técnicas Fotoacústicas/instrumentação , Processamento de Imagem Assistida por Computador/métodos , Compressão de Dados/métodos , Imagens de Fantasmas
14.
Colloids Surf B Biointerfaces ; 238: 113910, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38640797

RESUMO

This study represents an innovative approach to construct multi-functional nanoplatforms for cancer diagnosis and therapy by combining hyaluronic acid (HA) with iron-platinum nanoparticles (FePt NPs). These HA-coated FePt NPs, referred to as FePt@HA NPs, demonstrated remarkable biocompatibility, high absorption, and excellent light-to-heat conversion properties in the near-infrared (NIR) region, making them ideal candidates for photothermal therapy (PTT). In vitro studies revealed their effective cancer cell eradication under NIR laser irradiation, while in vivo experiments on mice showcased their superior heating capabilities. Moreover, FePt@HA NPs exhibited a distinct and strong photoacoustic (PA) signal, facilitating enhanced and precise intra-tumoral PA imaging. Our results highlight the potential of FePt@HA NPs as promising photothermal agents for future PTT applications. They offer high selectivity, precision, and minimal side effects in cancer treatment, along with their valuable PA imaging application for tumor localization and characterization.


Assuntos
Ácido Hialurônico , Ferro , Nanopartículas Metálicas , Técnicas Fotoacústicas , Terapia Fototérmica , Platina , Ácido Hialurônico/química , Ácido Hialurônico/farmacologia , Técnicas Fotoacústicas/métodos , Platina/química , Platina/farmacologia , Animais , Camundongos , Ferro/química , Humanos , Nanopartículas Metálicas/química , Sobrevivência Celular/efeitos dos fármacos , Camundongos Endogâmicos BALB C , Tamanho da Partícula , Propriedades de Superfície , Linhagem Celular Tumoral
15.
Med ; 5(5): 469-478.e3, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38531362

RESUMO

BACKGROUND: Spinal muscular atrophy is a progressive neuromuscular disorder and among the most frequent genetic causes of infant mortality. While recent advancements in gene therapy provide the potential to ameliorate the disease severity, there is currently no modality in clinical use to visualize dynamic pathophysiological changes in disease progression and regression after therapy. METHODS: In this prospective diagnostic clinical study, ten pediatric patients with spinal muscular atrophy and ten age- and sex-matched controls have been examined with three-dimensional optoacoustic imaging and clinical standard examinations to compare the spectral profile of muscle tissue and correlate it with motor function (ClinicalTrials.gov: NCT04115475). FINDINGS: We observed a reduced optoacoustic signal in muscle tissue of pediatric patients with spinal muscular atrophy. The reduction in signal intensity correlated with disease severity as assessed by grayscale ultrasound and standard motor function tests. In a cohort of patients who received disease-modifying therapy prior to the study, the optoacoustic signal intensity was similar to healthy controls. CONCLUSIONS: This translational study provides early evidence that three-dimensional optoacoustic imaging could have clinical implications in monitoring disease activity in spinal muscular atrophy. By visualizing and quantifying molecular changes in muscle tissue, disease progression and effects of gene therapy can be assessed in real time. FUNDING: The project was funded by ELAN Fonds (P055) at the University Hospital of the Friedrich-Alexander-Universität (FAU) Erlangen-Nurnberg to A.P.R.


Assuntos
Imageamento Tridimensional , Atrofia Muscular Espinal , Técnicas Fotoacústicas , Humanos , Feminino , Masculino , Estudos Prospectivos , Pré-Escolar , Imageamento Tridimensional/métodos , Técnicas Fotoacústicas/métodos , Criança , Atrofia Muscular Espinal/genética , Atrofia Muscular Espinal/diagnóstico por imagem , Atrofia Muscular Espinal/terapia , Lactente , Progressão da Doença , Estudos de Casos e Controles , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/patologia , Adolescente , Atrofias Musculares Espinais da Infância/diagnóstico por imagem , Atrofias Musculares Espinais da Infância/genética , Atrofias Musculares Espinais da Infância/terapia , Atrofias Musculares Espinais da Infância/fisiopatologia , Atrofias Musculares Espinais da Infância/diagnóstico
16.
Adv Sci (Weinh) ; 11(18): e2308336, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38445972

RESUMO

Tendon injuries resulting from accidents and aging are increasing globally. However, key tendon functional parameters such as microvascularity and oxygen perfusion remain inaccessible via the currently available clinical diagnostic tools, resulting in disagreements on optimal treatment options. Here, a new noninvasive method for anatomical and functional characterization of human tendons based on multispectral optoacoustic tomography (MSOT) is reported. Healthy subjects are investigated using a hand-held scanner delivering real-time volumetric images. Tendons in the wrist, ankle, and lower leg are imaged in the near-infrared optical spectrum to utilize endogenous contrast from Type I collagen. Morphology of the flexor carpi ulnaris, carpi radialis, palmaris longus, and Achilles tendons are reconstructed in full. The functional roles of the flexor digitorium longus, hallicus longus, and the tibialis posterior tendons have been visualized by dynamic tracking during toe extension-flexion motion. Furthermore, major vessels and microvasculature near the Achilles tendon are localized, and the global increase in oxygen saturation in response to targeted exercise is confirmed by perfusion studies. MSOT is shown to be a versatile tool capable of anatomical and functional tendon assessments. Future studies including abnormal subjects can validate the method as a viable noninvasive clinical tool for tendinopathy management and healing monitoring.


Assuntos
Técnicas Fotoacústicas , Tendões , Humanos , Técnicas Fotoacústicas/métodos , Tendões/diagnóstico por imagem , Adulto , Masculino , Tomografia/métodos , Feminino , Traumatismos dos Tendões/diagnóstico por imagem
17.
Angew Chem Int Ed Engl ; 63(19): e202320072, 2024 May 06.
Artigo em Inglês | MEDLINE | ID: mdl-38466238

RESUMO

Nitric oxide (NO) exhibits both pro- and anti-tumor effects. Therefore, real-time in vivo imaging and quantification of tumor NO dynamics are essential for understanding the conflicting roles of NO played in pathophysiology. The current molecular probes, however, cannot provide high-resolution imaging in deep tissues, making them unsuitable for these purposes. Herein, we designed a photoacoustic probe with an absorption maximum beyond 1000 nm for high spatial quantitative imaging of in vivo tumor NO dynamics. The probe exhibits remarkable sensitivity, selective ratiometric response behavior, and good tumor-targeting abilities, facilitating ratiometric imaging of tumor NO throughout tumor progression in a micron-resolution level. Using the probe as the imaging agent, we successfully quantified NO dynamics in tumor, liver and kidney. We have pinpointed an essential concentration threshold of around 80 nmol/cm3 for NO, which plays a crucial role in the "double-edged-sword" function of NO in tumors. Furthermore, we revealed a reciprocal relationship between the NO concentration in tumors and that in the liver, providing initial insights into the possible NO-mediated communication between tumor and the liver. We believe that the probe will help resolve conflicting aspects of NO biology and guide the design of imaging agents for tumor diagnosis and anti-cancer drug screening.


Assuntos
Óxido Nítrico , Técnicas Fotoacústicas , Óxido Nítrico/análise , Óxido Nítrico/metabolismo , Técnicas Fotoacústicas/métodos , Animais , Camundongos , Humanos , Neoplasias/diagnóstico por imagem , Raios Infravermelhos , Sondas Moleculares/química , Linhagem Celular Tumoral
18.
Opt Lett ; 49(6): 1469-1472, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489427

RESUMO

Optoacoustic (OA) imaging has achieved tremendous progress with state-of-the-art systems providing excellent functional and molecular contrast, centimeter scale penetration into living tissues, and ultrafast imaging performance, making it highly suitable for handheld imaging in the clinics. OA can greatly benefit from efficient integration with ultrasound (US) imaging, which remains the routine method in bedside clinical diagnostics. However, such integration has not been straightforward since the two modalities typically involve different image acquisition strategies. Here, we present a new, to our knowledge, hybrid optoacoustic ultrasound (OPUS) imaging approach employing a spherical array with dedicated segments for each modality to enable volumetric OA imaging merged with conventional B-mode US. The system performance is subsequently showcased in healthy human subjects. The new OPUS approach hence represents an important step toward establishing OA in point-of-care diagnostic settings.


Assuntos
Técnicas Fotoacústicas , Humanos , Técnicas Fotoacústicas/métodos , Ultrassonografia/métodos , Diagnóstico por Imagem , Voluntários Saudáveis
19.
Opt Lett ; 49(6): 1524-1527, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38489441

RESUMO

Longitudinal detection of hemodynamic changes based on wearable devices is imperative for monitoring human healthcare. Photoacoustic effect is extremely sensitive to variations in hemoglobin. Therefore, wearable photoacoustic devices are apt to monitor human healthcare via the observation of hemodynamics. However, the bulky system and difficulties in miniaturizing and optimizing the imaging interface restrict the development of wearable photoacoustic devices for human use. In this study, we developed a wearable photoacoustic watch with a fully integrated system in a backpack that has a size of 450 mm × 300 mm × 200 mm and an affordable weight of 7 kg for an adult to wear. The watch has a size of 43 mm × 30 mm × 24 mm, weighs 40 g, and features a lateral resolution of 8.7 µm, a field of view (FOV) of 3 mm in diameter, and a motorized adjustable focus for optimizing the imaging plane for different individuals. We recruited volunteers to wear the watch and the backpack and performed in vivo imaging of the vasculatures inside human wrists under the conditions of walking and human cuff occlusion to observe hemodynamic variations during different physiological states. The results suggest that the focus shifting capability of the watch makes it suitable for different individuals, and the compact and stable design of the entire system allows free movements of humans.


Assuntos
Técnicas Fotoacústicas , Dispositivos Eletrônicos Vestíveis , Adulto , Humanos , Diagnóstico por Imagem , Análise Espectral , Hemodinâmica
20.
Angew Chem Int Ed Engl ; 63(17): e202400372, 2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38445354

RESUMO

The second near-infrared (NIR-II) theranostics offer new opportunities for precise disease phototheranostic due to the enhanced tissue penetration and higher maximum permissible exposure of NIR-II light. However, traditional regimens lacking effective NIR-II absorption and uncontrollable excited-state energy decay pathways often result in insufficient theranostic outcomes. Herein a phototheranostic nano-agent (PS-1 NPs) based on azulenyl squaraine derivatives with a strong NIR-II absorption band centered at 1092 nm is reported, allowing almost all absorbed excitation energy to dissipate through non-radiative decay pathways, leading to high photothermal conversion efficiency (90.98 %) and strong photoacoustic response. Both in vitro and in vivo photoacoustic/photothermal therapy results demonstrate enhanced deep tissue cancer theranostic performance of PS-1 NPs. Even in the 5 mm deep-seated tumor model, PS-1 NPs demonstrated a satisfactory anti-tumor effect in photoacoustic imaging-guided photothermal therapy. Moreover, for the human extracted tooth root canal infection model, the synergistic outcomes of the photothermal effect of PS-1 NPs and 0.5 % NaClO solution resulted in therapeutic efficacy comparable to the clinical gold standard irrigation agent 5.25 % NaClO, opening up possibilities for the expansion of NIR-II theranostic agents in oral medicine.


Assuntos
Ciclobutanos , Nanopartículas , Neoplasias , Técnicas Fotoacústicas , Humanos , Nanopartículas/uso terapêutico , Nanomedicina Teranóstica/métodos , Fenóis/farmacologia , Ciclobutanos/farmacologia , Neoplasias/diagnóstico por imagem , Neoplasias/tratamento farmacológico , Fototerapia , Técnicas Fotoacústicas/métodos , Linhagem Celular Tumoral
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA