Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.787
Filtrar
1.
Trials ; 25(1): 327, 2024 May 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760769

RESUMO

BACKGROUND: The recent guidelines from the European and American Hernia Societies recommend a continuous small-bite suturing technique with slowly absorbable sutures for fascial closure of midline abdominal wall incisions to reduce the incidence of wound complications, especially for incisional hernia. However, this is based on low-certainty evidence. We could not find any recommendations for skin closure. The wound closure technique is an important determinant of the risk of wound complications, and a comprehensive approach to prevent wound complications should be developed. METHODS: We propose a single-institute, prospective, randomized, blinded-endpoint trial to assess the superiority of the combination of continuous suturing of the fascia without peritoneal closure and continuous suturing of the subcuticular tissue (study group) over that of interrupted suturing of the fascia together with the peritoneum and interrupted suturing of the subcuticular tissue (control group) for reducing the incidence of midline abdominal wall incision wound complications after elective gastroenterological surgery with a clean-contaminated wound. Permuted-block randomization with an allocation ratio of 1:1 and blocking will be used. We hypothesize that the study group will show a 50% reduction in the incidence of wound complications. The target number of cases is set at 284. The primary outcome is the incidence of wound complications, including incisional surgical site infection, hemorrhage, seroma, wound dehiscence within 30 days after surgery, and incisional hernia at approximately 1 year after surgery. DISCUSSION: This trial will provide initial evidence on the ideal combination of fascial and skin closure for midline abdominal wall incision to reduce the incidence of overall postoperative wound complications after gastroenterological surgery with a clean-contaminated wound. This trial is expected to generate high-quality evidence that supports the current guidelines for the closure of abdominal wall incisions from the European and American Hernia Societies and to contribute to their next updates. TRIAL REGISTRATION: UMIN-CTR UMIN000048442. Registered on 1 August 2022. https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000055205.


Assuntos
Parede Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Procedimentos Cirúrgicos do Sistema Digestório , Procedimentos Cirúrgicos Eletivos , Hérnia Incisional , Infecção da Ferida Cirúrgica , Técnicas de Sutura , Humanos , Estudos Prospectivos , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos , Parede Abdominal/cirurgia , Técnicas de Sutura/efeitos adversos , Infecção da Ferida Cirúrgica/prevenção & controle , Infecção da Ferida Cirúrgica/etiologia , Infecção da Ferida Cirúrgica/epidemiologia , Procedimentos Cirúrgicos do Sistema Digestório/efeitos adversos , Procedimentos Cirúrgicos do Sistema Digestório/métodos , Hérnia Incisional/prevenção & controle , Hérnia Incisional/etiologia , Hérnia Incisional/epidemiologia , Procedimentos Cirúrgicos Eletivos/métodos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Resultado do Tratamento , Incidência , Cicatrização , Estudos de Equivalência como Asunto , Ensaios Clínicos Controlados Aleatórios como Assunto , Fatores de Tempo
3.
Minerva Urol Nephrol ; 76(2): 176-184, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38742552

RESUMO

BACKGROUND: The debate between single-layer and double-layer renorrhaphy techniques during robot-assisted partial nephrectomy (RPN) represents a subject of ongoing discourse. The present analysis aims to compare the perioperative and functional outcomes of single- versus double-layer renorrhaphy during RPN. METHODS: Study data were retrieved from prospectively maintained institutional database (Jan2018-May2023). Study population was divided into two groups according to the number of layers (single vs. double) used for renorrhaphy. Baseline and perioperative data were compared. Postoperative surgical outcomes included type and grade of complications as classified according to Clavien-Dindo. Serum creatinine and estimated glomerular filtration rate were used to measure renal function. RESULTS: Three hundred seventeen patients were included in the analysis: 209 received single-layer closure, while 108 underwent double-layer renorrhaphy. Baseline characteristics were not statistically different between the groups. Comparable low incidence of intraoperative complications was observed between the cohorts (P=0.5). No difference was found in terms of mean (95% CI) Hb level drop postoperation (single-layer: 1.6 g/dL [1.5-1.7] vs. double-layer: 1.4 g/dL [1.2-1.5], P=0.3). Overall and "major" rate of complications were 16% and 3%, respectively, with no difference observed in terms of any grade (P=0.2) and major complications (P=0.7). Postoperative renal function was not statistically different between the treatment modalities. At logistic regression analyses, no difference in terms of probability of overall (OR 0.82 [0.63-1.88]) and major (OR 0.94 [0.77-6.44]) complications for the number of suture layers was observed. CONCLUSIONS: Single-layer and double-layer renorrhaphy demonstrated comparable perioperative and functional outcomes within the setting of the present study.


Assuntos
Nefrectomia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Robóticos , Técnicas de Sutura , Humanos , Nefrectomia/métodos , Nefrectomia/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Feminino , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Resultado do Tratamento , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/instrumentação , Idoso , Rim/cirurgia , Rim/fisiopatologia , Taxa de Filtração Glomerular , Neoplasias Renais/cirurgia , Complicações Intraoperatórias/epidemiologia , Complicações Intraoperatórias/etiologia , Estudos Retrospectivos , Estudos Prospectivos
4.
Best Pract Res Clin Gastroenterol ; 69: 101900, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38749581

RESUMO

Despite the evolution in tools and techniques, perforation is still one of the most pernicious adverse events of therapeutic endoscopy with potentially huge consequences. As advanced endoscopic resection techniques are worldwide spreading, endoscopists must be ready to manage intraprocedural perforations. In fact, immediate endoscopic closure through a prompt diagnosis represents the first-line option, saving patients from surgery, long hospitalizations and worse outcomes. Traditional and novel endoscopic closure modalities, including clips, suturing devices, stents and vacuum therapy, are increasingly expanding the therapeutic armamentarium for closing these defects. Nevertheless, available literature on this topic is currently limited. In this review our goal is to give an overview on the management of perforations occurring during endoscopic resections, with particular attention to characteristics, advantages, disadvantages and new horizons of endoscopic closure tools.


Assuntos
Perfuração Intestinal , Humanos , Perfuração Intestinal/cirurgia , Perfuração Intestinal/etiologia , Técnicas de Sutura/efeitos adversos , Stents , Instrumentos Cirúrgicos , Complicações Intraoperatórias/etiologia , Complicações Intraoperatórias/terapia , Tratamento de Ferimentos com Pressão Negativa/efeitos adversos , Resultado do Tratamento
5.
Artigo em Inglês | MEDLINE | ID: mdl-38684397

RESUMO

PURPOSE: This report reviews our experience with right lower sleeve lobectomy and describes our technique and approach to perioperative patient management. METHODS: We retrospectively reviewed 11 patients who underwent right lower sleeve lobectomy for lung cancer. Surgical techniques and perioperative management were also investigated. RESULTS: Bronchoplasty was performed using 4-0 absorbable monofilament sutures. The deepest portion was anastomosed using continuous sutures; interrupted sutures were used for the more superficial portions. The truncus intermedius and right middle lobe bronchus should be anastomosed in a natural position. Anastomosis patency was confirmed using intraoperative bronchoscopy. Separation of the right upper and middle lobes and pericardiotomy at the inferior edge of the superior pulmonary vein are useful for mobilizing the right middle lobe. Death during hospitalization and treatment-related death did not occur. One patient developed pneumonia, and another developed a bronchopleural fistula. CONCLUSION: We reported our technique of right lower sleeve lobectomy and our approach to perioperative patient management. Sharing knowledge is essential to completing this rare surgery.


Assuntos
Neoplasias Pulmonares , Pneumonectomia , Técnicas de Sutura , Humanos , Pneumonectomia/efeitos adversos , Pneumonectomia/métodos , Pneumonectomia/mortalidade , Estudos Retrospectivos , Masculino , Pessoa de Meia-Idade , Feminino , Idoso , Resultado do Tratamento , Neoplasias Pulmonares/cirurgia , Neoplasias Pulmonares/patologia , Neoplasias Pulmonares/diagnóstico por imagem , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica , Brônquios/cirurgia , Assistência Perioperatória , Complicações Pós-Operatórias/etiologia , Broncoscopia , Fatores de Tempo
6.
Europace ; 26(5)2024 May 02.
Artigo em Inglês | MEDLINE | ID: mdl-38647070

RESUMO

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Técnicas de Sutura , Humanos , Fibrilação Atrial/cirurgia , Feminino , Masculino , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Estudos Prospectivos , Veias Pulmonares/cirurgia , Técnicas de Sutura/efeitos adversos , Idoso , Resultado do Tratamento , Alemanha , Fatores de Tempo , Dispositivos de Oclusão Vascular , Deambulação Precoce , Técnicas Hemostáticas/instrumentação
7.
Khirurgiia (Mosk) ; (4): 29-37, 2024.
Artigo em Russo | MEDLINE | ID: mdl-38634581

RESUMO

OBJECTIVE: To evaluate the short-term outcomes of mechanical and hand-sewn laparoscopic one-anastomosis mini-gastric bypass. MATERIAL AND METHODS: There were 233 patients who underwent laparoscopic one-anastomosis mini-gastric bypass. Short-term results were analyzed in groups of mechanical (the first group, n=108) and hand-sewn (the second group, n=125) gastrojejunostomy. No significant between-group differences in baseline data were detected (demographic characteristics, body mass index, comorbidity and previous abdominal surgeries). RESULTS: Surgery time and blood loss were similar in both groups. Intraoperative morbidity was 7.2-10.2% (p=0.485). All complications required no surgical conversion (Satava-Kazaryan grade I). Overall postoperative morbidity was 16.0-21.3% (p=0.314). Most events corresponded to Accordion grade I and had no significant effect on hospital-stay. CONCLUSION: This study revealed no significant differences in short-term outcomes after laparoscopic one-anastomosis gastric bypass with mechanical and hand-sewn gastrojejunostomy. Further study of long-term clinical outcomes is necessary.


Assuntos
Derivação Gástrica , Laparoscopia , Obesidade Mórbida , Humanos , Derivação Gástrica/métodos , Laparoscopia/métodos , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Obesidade Mórbida/cirurgia , Complicações Pós-Operatórias/etiologia , Estudos Retrospectivos
8.
Int J Surg ; 110(3): 1367-1375, 2024 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-38484258

RESUMO

BACKGROUND: A diverting loop ileostomy (DLI) is performed in laparoscopic anterior rectal resection (LAR) surgery at high risk of anastomotic fistula. Minimally invasive surgery promotes postoperative recovery and cosmetics. To reduce abdominal trauma, specimen extraction through stoma incision (EXSI) is usually performed to avoid auxiliary abdominal incision with enlarged stomal incision. The traditional suture method (TSM) reduces the incision size by suturing the ends of the enlarged incision, leading to peristomal incisions and a higher risk of stomal complications. The study aimed to introduce the dumpling suture method (DSM) of PLI and compare this new method with TSM. MATERIALS AND METHODS: The authors propose a novel stoma suture technique, which utilized a method of skin folding suture to reduce the enlarged incision size. A retrospective analysis was conducted on 71 consecutive patients with rectal cancer who underwent LAR-DLI with EXSI, and the intraoperative details and postoperative outcomes of the two groups were measured. RESULTS: The DSM group showed a lower stomal complication rate (10.3 vs. 35.7%, P=0.016) than that of the TSM group. The scores of DET (Discoloration, Erosion, Tissue overgrowth), stomal pain, quality of life were all significantly lower in DSM group than in TSM group. In multivariate analysis, DSM was an independent protective factor for stoma-related complications. Operative time, time to first flatus, defecation and eat, nonstomal related postoperative complications were similar in both groups. CONCLUSION: DSM utilizes a method of skin folding suture to reduce the enlarged incision size, which is safe and effective in reducing the incidence of peristomal skin infections and stomal complications. This procedure offers a novel suturing approach for loop ileostomy with enlarged incision, effectively reducing the postoperative trauma and incidence of stomal complications.


Assuntos
Laparoscopia , Neoplasias Retais , Ferida Cirúrgica , Humanos , Ileostomia/métodos , Estudos Retrospectivos , Estudos de Coortes , Qualidade de Vida , Laparoscopia/efeitos adversos , Laparoscopia/métodos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Complicações Pós-Operatórias/epidemiologia , Neoplasias Retais/cirurgia , Anastomose Cirúrgica/efeitos adversos , Ferida Cirúrgica/complicações , Técnicas de Sutura/efeitos adversos , Suturas/efeitos adversos
9.
Eur J Orthop Surg Traumatol ; 34(3): 1635-1645, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38368580

RESUMO

PURPOSE: We present the functional and clinical results of a combined surgical technique that functionally restores chronic Acromioclavicular Joint Instability (AJI). The method combines a double-looped suture fixation augmented with a semitendinosus autograft. METHODS: Between 2017 and 2021, 15 patients were treated using the surgical technique. All patients suffered an Acromioclavicular Joint Separation that remained untreated for at least 6 (6-16) weeks after the initial injury. Four Ethibond sutures were passed below the coracoid process and through a 4.5 drill hole in the clavicle. The sutures provided adequate horizontal and vertical reduction and stabilization of the clavicle. A semitendinosus autograft was passed below the coracoid process and looped around the clavicle. The remaining graft limbs were used to reconstruct the acromioclavicular capsule. Patients were radiologically evaluated with bilateral anteroposterior (AP), Zanca, and Alexander views. The clinical evaluation was based on the Acromioclavicular Joint Instability Score and the Constant-Murley Score. RESULTS: The mean follow-up period was 31.2 months (17-61). The mean last ACJIS and CMS scores were 96 (90-100) and 97.67 (87-100), respectively. Reduction of the clavicle was radiologically confirmed in all cases throughout the follow-up period. AC arthritis was reported in 1 case without associated clinical symptoms. No significant complications were reported, and all patients returned to the pre-injury activity level. CONCLUSION: The presented functional reconstruction of the AC joint disruption in chronic cases is an effective and secure method with low complication rates and good clinical results. LEVEL OF EVIDENCE III: This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors www.springer.com/00266 .


Assuntos
Articulação Acromioclavicular , Músculos Isquiossurais , Luxações Articulares , Instabilidade Articular , Humanos , Articulação Acromioclavicular/cirurgia , Articulação Acromioclavicular/lesões , Autoenxertos , Instabilidade Articular/etiologia , Instabilidade Articular/cirurgia , Luxações Articulares/cirurgia , Técnicas de Sutura/efeitos adversos , Ligamentos Articulares/cirurgia
10.
Tech Coloproctol ; 28(1): 30, 2024 Feb 07.
Artigo em Inglês | MEDLINE | ID: mdl-38321328

RESUMO

BACKGROUND: Low anterior resection in patients with rectal cancer may require a defunctioning loop ileostomy formation that requires closure after a period of time. There are three common techniques for ileostomy closure: anterior repair (AR or fold-over closure), resection and hand-sewn anastomosis (RHA), and resection and stapled anastomosis (RSA). We aimed to compare them on the basis of operative and postoperative features. METHODS: Patients with rectal cancer who underwent low anterior resection without complications were included in this study and randomly assigned to three parallel groups to undergo loop ileostomy closure via either AR, RHA, or RSA. Early and late outcomes were gathered from all included patients. RESULTS: Among 93 patients with a mean age of 56.21 ± 11.78 years, consisting of 58 (62.4%) men, 31 patients underwent AR, 30 patients RHA, and 32 patients RSA. There was no significant difference among the groups regarding the frequency and location of intraoperative injuries (P = 0.157). The AR groups demonstrated significantly less consumption of gauzes following intraoperative bleeding compared to the two others groups. The results showed that the duration of surgery in the RSA was significantly shorter than in the AR or RHA group (both P < 0.001). Regarding postoperative course, only one case of hematoma and two cases of surgical wound infection occurred in the RHA group. Anastomotic leakage and complete or partial obstruction did not occur in any group of patients. Latent postoperative complications did not occur in any group of patients. The median time between surgery and discharge as well as the interval until first gas passage, first defecation, oral tolerated liquid diet, as well as oral tolerated soft and regular diet in the AR group were significantly lower than in the two other groups (both P < 0.001). However, there was no statistical difference in these intervals between the RHA and RSA groups. CONCLUSIONS: Resection and stapled anastomosis had the shortest duration among the three techniques; however, anterior repair had faster recovery, including earlier tolerated oral diet, gas passing and defecation, and discharge, in comparison with the other techniques. TRIAL REGISTRATION: Trial registration number IRCT20120129008861N5.


Assuntos
Ileostomia , Neoplasias Retais , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Ileostomia/efeitos adversos , Técnicas de Sutura/efeitos adversos , Anastomose Cirúrgica/efeitos adversos , Fístula Anastomótica/etiologia , Neoplasias Retais/cirurgia , Complicações Pós-Operatórias/etiologia
11.
J Cosmet Dermatol ; 23(6): 2199-2208, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38400620

RESUMO

BACKGROUND: Prevailing tension-reducing suture methods have a spectrum of issues. This study presents a straightforward yet highly efficacious suture technique known as the Split-level Folding, Step-type Tension-relieving Suture technique, which could play a pivotal role in preempting incisional scarring. AIMS: To introduce Split-level Folding, Step-type Tension-relieving Suture technique and assess its effect on scar minimization. METHODS: A retrospective analysis of 64 patients who underwent treatment utilizing the proposed suturing methodology. Assessment parameters included the Patient and Observer Scar Assessment Scale (POSAS), the Vancouver Scar Scale (VSS), scar width, complications, and all evaluated at 6- and 12-month postoperatively. RESULTS: At 12-month follow-up, the POSAS and VSS scores in the normal suture group (32.58 ± 5.43, 3.58 ± 1.39) were considerably higher than the step-type suture group (29.75 ± 3.56, p = 0.0007; 2.78 ± 1.17, p = 0.0006). Moreover, the step-type suture group showcased a significantly narrower average incision scar width (1.62 ± 0.36) than the normal suture group (1.87 ± 0.42, p = 0.0004). This novel tension-relieving suture technique that effectively circumvents the occurrence of persistent localized eversion and other complications often associated with traditional tension-relieving sutures. CONCLUSIONS: The Split-level Folding, Step-type Tension-relieving Suture technique emerges as a highly promising option for averting incisional scarring. This suture method works well for incisions on the chest, back, and extremities, resulting in significantly better long-term outcomes.


Assuntos
Cicatriz , Técnicas de Sutura , Humanos , Técnicas de Sutura/efeitos adversos , Cicatriz/etiologia , Cicatriz/prevenção & controle , Estudos Retrospectivos , Feminino , Adulto , Masculino , Pessoa de Meia-Idade , Resultado do Tratamento , Seguimentos , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle , Suturas/efeitos adversos , Adulto Jovem
12.
Med Eng Phys ; 123: 104076, 2024 01.
Artigo em Inglês | MEDLINE | ID: mdl-38365329

RESUMO

The birefringent nature of the human cornea plays an important role in comprehending its structural behavior in both diseased and surgical conditions. During corneal transplantation, irregular astigmatism is a common post-surgical complication that depends on the characteristics of suturing. Four human cadaver corneas are subjected to an in-vitro model of a typical full-thickness penetrating keratoplasty (PK) procedure using 16 simple interrupted 10-0 vicyrl sutures. The birefringence of these four corneas is analyzed using digital photoelasticity and compared with the control cornea (without PK). It is found that the sutures and their mutual interaction influence the morphology of the peripheral birefringence of the cornea. The findings of the present investigation are pertinent to intraoperative suture management during PK. Results suggest conserving the typical diamond-shaped morphology of peripheral birefringence would ensure uniform distribution of sutures. Therefore, birefringence imaging could be useful in suture management to ensure proper apposition of the graft-host junction, thus minimizing the risk of irregular astigmatism.


Assuntos
Astigmatismo , Ceratoplastia Penetrante , Humanos , Ceratoplastia Penetrante/efeitos adversos , Ceratoplastia Penetrante/métodos , Astigmatismo/etiologia , Astigmatismo/cirurgia , Topografia da Córnea/efeitos adversos , Acuidade Visual , Técnicas de Sutura/efeitos adversos , Córnea/cirurgia , Complicações Pós-Operatórias , Colágeno
13.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38184452

RESUMO

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Assuntos
Cateterismo Periférico , Oxigenação por Membrana Extracorpórea , Coração Auxiliar , Técnicas Hemostáticas , Punções , Dispositivos de Oclusão Vascular , Humanos , Estudos Retrospectivos , Masculino , Feminino , Resultado do Tratamento , Pessoa de Meia-Idade , Idoso , Oxigenação por Membrana Extracorpórea/efeitos adversos , Oxigenação por Membrana Extracorpórea/instrumentação , Fatores de Tempo , Técnicas Hemostáticas/instrumentação , Técnicas Hemostáticas/efeitos adversos , Cateterismo Periférico/efeitos adversos , Cateterismo Periférico/instrumentação , Remoção de Dispositivo/efeitos adversos , Técnicas de Sutura/instrumentação , Técnicas de Sutura/efeitos adversos , Artéria Femoral , Choque Cardiogênico/terapia , Choque Cardiogênico/mortalidade , Choque Cardiogênico/fisiopatologia , Choque Cardiogênico/diagnóstico , Fatores de Risco , Hemorragia/etiologia , Hemorragia/prevenção & controle
14.
Aesthet Surg J ; 44(6): 633-640, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38243919

RESUMO

BACKGROUND: Duramesh (Mesh Suture Inc., Chicago, IL) is a new suturing concept, combining the principles of mesh with the precision, flexibility, and versatility of a suture, suitable also for abdominal rectus diastasis (ARD) correction. OBJECTIVES: This prospective research aimed to compare mesh with the standard polypropylene suture plication for rectus diastasis repair with regard to safety (infection, seroma, hematoma, surgical wound dehiscence, and fistula rates and hospital stay); effectiveness (ARD recurrence by ultrasound sonography, palpability of the muscular suture, surgical time, and postoperative pain evaluation); and satisfaction of the patients based on the BODY-Q, a patient-reported outcome measure. METHODS: Sixty-five of the initial 70 patients who underwent rectus diastasis repair with a 6-month follow-up were randomly divided into 2 groups, comprising 33 patients treated with Duramesh and 32 patients treated with standard 0 polypropylene suture plication. Data regarding infection, seroma, hematoma, surgical wound dehiscence, and fistula rates; hospital stay; ARD recurrence; palpability of the muscular suture; surgical time; postoperative pain evaluation (measured by visual analog scale, or VAS); and the BODY-Q were analyzed by Prism 9 (GraphPad Software Inc., San Diego, CA). RESULTS: No significant differences were reported between the 2 groups with regard to infection, seroma, hematoma, surgical wound dehiscence, and fistula rates and hospital stay. The mesh decreased the time required to perform plication compared with standard polypropylene detached sutures. No statistically significant differences were found with respect to the VAS and BODY-Q data. CONCLUSIONS: Duramesh 0 application for rectus diastasis repair is safe and effective without compromising aesthetic improvement when compared with standard 0 polypropylene plication.


Assuntos
Diástase Muscular , Polipropilenos , Reto do Abdome , Telas Cirúrgicas , Técnicas de Sutura , Humanos , Estudos Prospectivos , Feminino , Telas Cirúrgicas/efeitos adversos , Reto do Abdome/cirurgia , Masculino , Pessoa de Meia-Idade , Técnicas de Sutura/instrumentação , Técnicas de Sutura/efeitos adversos , Adulto , Resultado do Tratamento , Diástase Muscular/cirurgia , Satisfação do Paciente , Dor Pós-Operatória/etiologia , Suturas , Duração da Cirurgia , Complicações Pós-Operatórias/etiologia , Tempo de Internação , Adulto Jovem , Recidiva , Seguimentos , Medidas de Resultados Relatados pelo Paciente , Idoso
15.
Hernia ; 28(2): 527-535, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38212505

RESUMO

PURPOSE: Using small instead of large bites for laparotomy closure results in lower incidence of incisional hernia, but no consensus exists on which suture material to use. This study aimed to compare five different closure strategies in a standardized experimental setting. METHODS: Fifty porcine abdominal walls were arranged into 5 groups: (A) running 2/0 polydioxanone; (B) interlocking 2/0 polydioxanone; (C) running size 0 barbed polydioxanone; (D) running size 0 barbed glycolic acid and trimethylene carbonate; (E) running size 0 suturable polypropylene mesh. The small-bites technique was used for linea alba closure in all. The abdominal walls were divided into a supra- and infra-umbilical half, resulting in 20 specimens per group that were pulled apart in a tensile testing machine. Maximum tensile force and types of suture failure were registered. RESULTS: The highest tensile force was measured when using barbed polydioxanone (334.8 N ± 157.0), but differences did not reach statistical significance. Infra-umbilical abdominal walls endured a significantly higher maximum tensile force compared to supra-umbilical (397 N vs 271 N, p < 0.001). Barbed glycolic acid and trimethylene carbonate failed significantly more often (25% vs 0%, p = 0.008). CONCLUSION: Based on tensile force, both interlocking and running suture techniques using polydioxanone, and running sutures using barbed polydioxanone or suturable mesh, seem to be suitable for abdominal wall closure. Tensile strength was significantly higher in infra-umbilical abdominal walls compared to supra-umbilical. Barbed glycolic acid and trimethylene carbonate should probably be discouraged for fascial closure, because of increased risk of suture failure.


Assuntos
Parede Abdominal , Técnicas de Fechamento de Ferimentos Abdominais , Glicolatos , Suínos , Animais , Parede Abdominal/cirurgia , Polidioxanona , Herniorrafia , Técnicas de Sutura/efeitos adversos , Modelos Animais , Resistência à Tração , Laparotomia , Suturas , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos
16.
BMC Pregnancy Childbirth ; 24(1): 9, 2024 Jan 02.
Artigo em Inglês | MEDLINE | ID: mdl-38166803

RESUMO

BACKGROUND: Intractable postpartum hemorrhage (PPH) during cesarean section has been a significant concern for obstetricians. We aimed to explore the effectiveness and safety of a new type of uterine compression suture, the step-wise surgical technique of knapsack-like sutures for treating intractable PPH caused by uterine atony and placenta factors in cesarean section. METHODS: The step-wise surgical technique of knapsack-like sutures was established on the basis of the artful combination of vertical strap-like sutures and an annular suture-ligation technique. This novel surgical technique was applied to 34 patients diagnosed with PPH during cesarean section due to severe uterine atony and placental factors in our department. The hemostatic effects, clinical outcomes and follow-up visit results were all reviewed and analyzed. RESULTS: This new uterine compression suture successfully stopped bleeding in 33 patients, and the effective rate was 97.06%. Only 1 patient failed and was changed to use bilateral uterine arterial embolization and internal iliac artery embolization. The follow-up visits indicated that 33 patients restored menstruation except for 1 who was diagnosed with amenorrhea. The gynecological ultrasound tests of all the patients suggested good uterine involutions, and they had no obvious complaints such as hypogastralgia. CONCLUSIONS: This step-wise surgical technique of knapsack-like uterine compression sutures can compress the uterus completely. It is a technique that can conserve the uterus and fertility function without special equipment in caesarean section for PPH, with the characteristics of being safe, simple and stable (3 S) with rapid surgery, reliable hemostasis and resident doctor to operation (3R).


Assuntos
Hemorragia Pós-Parto , Inércia Uterina , Feminino , Humanos , Gravidez , Hemorragia Pós-Parto/cirurgia , Hemorragia Pós-Parto/etiologia , Cesárea/efeitos adversos , Inércia Uterina/cirurgia , Hemostasia Cirúrgica/métodos , Placenta/cirurgia , Útero/cirurgia , Útero/irrigação sanguínea , Suturas/efeitos adversos , Técnicas de Sutura/efeitos adversos
17.
Eur J Orthop Surg Traumatol ; 34(3): 1279-1286, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38070017

RESUMO

BACKGROUND: To retrospectively evaluate the clinical outcomes of patients treated for syndesmotic injuries with an all-suture construct technique and compare their patient reported outcome scores with historically published outcomes of syndesmotic injuries fixed with suspensory suture buttons. METHODS: This was a retrospective case series of patients treated at a Level 1 Trauma Center from May 1, 2018, to June 30, 2022. Ten patients aged 18 and older with unstable syndesmotic injuries treated with all-suture repair. Patients were excluded if they were treated with trans-osseous screws, had previous failed syndesmotic fixation, or suspensory suture button fixation. Patient-reported outcomes including Visual Analog Scale (VAS) pain scores, American Orthopaedic Foot and Ankle Society (AOFAS) ankle and hindfoot scores, and complications were recorded. RESULTS: In the patients with 6 weeks or more of radiographic follow-up (N = 9), there was no evidence of nonunion, loss of fixation, hardware complication, or whitling of the fibula by the suture. At final follow-up average VAS pain scores were 1.5 out of 10 (range 0-4; SD 1.2), AOFAS ankle and hindfoot scores averaged 89.6 out of 100 (range 86-100; SD 6.1). The pain subscale of the AOFAS score averaged 37.5 out of 40 (range 35-40; SD 2.5). The functional subscale of the AOFAS score averaged 46 out of 50 (range 44-50; SD 3.0). Stiffness was reported in one patient at their follow-up visits, which resolved with continued physical therapy. There were no superficial or deep infections. CONCLUSIONS: In conclusion, this case series presents the first clinical outcomes of an all-suture fixation technique for treatment of unstable syndesmotic ankle injuries. Our results suggest that the all-suture fixation technique results in similar patient reported outcomes when compared with historically reported patient reported outcomes of suspensory suture button fixation, and low rates of complication or hardware failure.


Assuntos
Fraturas do Tornozelo , Traumatismos do Tornozelo , Humanos , Estudos Retrospectivos , Parafusos Ósseos/efeitos adversos , Traumatismos do Tornozelo/diagnóstico por imagem , Traumatismos do Tornozelo/cirurgia , Fixação Interna de Fraturas/efeitos adversos , Fixação Interna de Fraturas/métodos , Articulação do Tornozelo/diagnóstico por imagem , Articulação do Tornozelo/cirurgia , Técnicas de Sutura/efeitos adversos , Suturas , Dor/etiologia , Fraturas do Tornozelo/diagnóstico por imagem , Fraturas do Tornozelo/cirurgia , Fraturas do Tornozelo/etiologia , Resultado do Tratamento
18.
Chirurgie (Heidelb) ; 95(1): 3-9, 2024 Jan.
Artigo em Alemão | MEDLINE | ID: mdl-38078933

RESUMO

BACKGROUND: From an epidemiological point of view, one third of the population in industrialized countries will undergo abdominal surgery during their lifetime. Depending on the degree of patient-related and procedure-related risks, the occurrence of incisional hernias is associated in a range of up to 30% at 2­year follow-up and even up to 60% at 5 years. In addition to influencing comorbidities, the type of surgical approach and closure technique are of critical importance. OBJECTIVE: To present a descriptive evidence-based recommendation for abdominal wall closure and prophylactic mesh augmentation. MATERIAL AND METHODS: A concise summary was prepared incorporating the current literature and existing guidelines. RESULTS: According to recent studies the recognized risk for the occurrence of incisional hernias in the presence of obesity and abdominal aortic diseases also applies to patients undergoing colorectal surgery and the presence of diastasis recti abdominis. Based on high-level published data, the short stitch technique for midline laparotomy in the elective setting has a high level of evidence to be a standard procedure. Patients with an increased risk profile should receive prophylactic mesh reinforcement, either onlay or sublay, in addition to the short stitch technique. In emergency laparotomy, the individual risk of infection with respect to the closure technique used must be included. CONCLUSION: The avoidance of incisional hernias is primarily achieved by the minimally invasive access for laparoscopy. For closure of the most commonly used midline approach, the short stitch technique and, in the case of existing risk factors, additionally mesh augmentation are recommended.


Assuntos
Hérnia Incisional , Humanos , Técnicas de Fechamento de Ferimentos Abdominais/efeitos adversos , Hérnia Incisional/epidemiologia , Hérnia Incisional/cirurgia , Hérnia Incisional/etiologia , Fatores de Risco , Telas Cirúrgicas , Técnicas de Sutura/efeitos adversos , Guias de Prática Clínica como Assunto
19.
Surg Endosc ; 38(3): 1230-1238, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38091107

RESUMO

BACKGROUND: Postoperative pancreatic fistulas (POPFs) are prevalent and major postoperative complications of distal pancreatectomy (DP). There are numerous ways to manage the pancreatic stump. However, no single approach has been shown to be consistently superior. Moreover, the potential role of robotic systems in reducing POPFs has received little attention. METHODS: The clinical data of 119 patients who had consecutively received robotic distal pancreatectomy between January 2019 and December 2022 were retrospectively analyzed. Patients were divided into two groups according to the method of handling the pancreatic stump. The attributes of the patients and the variables during the perioperative period were compared. RESULTS: The analysis included 72 manual sutures and 47 stapler procedures. The manual suture group had a shorter operative time (removing installation time) than the stapler group (125.25 ± 63.04 min vs 153.30 ± 62.03 min, p = 0.019). Additionally, the manual suture group had lower estimated blood loss (50 mL vs 100 mL, p = 0.009) and a shorter postoperative hospital stay. There were no significant differences in the incidence of clinically relevant POPFs between the two groups (18.1% vs 23.4%, P > 0.05). No perioperative death occurred in either group. CONCLUSION: The manual suturing technique was shown to have an incidence of POPFs similar to the stapler technique in robotic distal pancreatectomy and to be safe and feasible.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Humanos , Pancreatectomia/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Estudos Retrospectivos , Fístula Pancreática/epidemiologia , Fístula Pancreática/etiologia , Fístula Pancreática/prevenção & controle , Técnicas de Sutura/efeitos adversos , Suturas/efeitos adversos , Laparoscopia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/prevenção & controle
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA