Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.300
Filtrar
1.
Sci Rep ; 14(1): 10449, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714775

RESUMO

The body temperature of infants at equilibrium with their surroundings is balanced between heat production from metabolism and the transfer of heat to the environment. Total heat production is related to body size, which is closely related to metabolic rate and oxygen consumption. Body temperature control is a crucial aspect of neonatal medicine but we have often struggled with temperature measures. Contactless infrared thermography (IRT) is useful for vulnerable neonates and may be able to assess their spontaneous thermal metabolism. The present study focused on heat oscillations and their cause. IRT was used to measure the skin temperature every 15 s of neonates in an incubator. We analyzed the thermal data of 27 neonates (32 measurements), calculated the average temperature within specified regions, and extracted two frequency components-Components A and B-using the Savitzky-Golay method. Furthermore, we derived an equation describing the cycle-named cycle T-for maintaining body temperature according to body weight. A positive correlation was observed between cycle T and Component B (median [IQR]: 368 [300-506] s). This study sheds light on the physiological thermoregulatory function of newborns and will lead to improved temperature management methods for newborns, particularly premature, low-birth-weight infants.


Assuntos
Regulação da Temperatura Corporal , Termografia , Humanos , Recém-Nascido , Termografia/métodos , Regulação da Temperatura Corporal/fisiologia , Feminino , Masculino , Monitorização Fisiológica/métodos , Temperatura Corporal/fisiologia , Temperatura Cutânea/fisiologia
2.
Sensors (Basel) ; 24(9)2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38732798

RESUMO

Photoplethysmography (PPG) is a non-invasive method used for cardiovascular monitoring, with multi-wavelength PPG (MW-PPG) enhancing its efficacy by using multiple wavelengths for improved assessment. This study explores how contact force (CF) variations impact MW-PPG signals. Data from 11 healthy subjects are analyzed to investigate the still understudied specific effects of CF on PPG signals. The obtained dataset includes simultaneous recording of five PPG wavelengths (470, 525, 590, 631, and 940 nm), CF, skin temperature, and the tonometric measurement derived from CF. The evolution of raw signals and the PPG DC and AC components are analyzed in relation to the increasing and decreasing faces of the CF. Findings reveal individual variability in signal responses related to skin and vasculature properties and demonstrate hysteresis and wavelength-dependent responses to CF changes. Notably, all wavelengths except 631 nm showed that the DC component of PPG signals correlates with CF trends, suggesting the potential use of this component as an indirect CF indicator. However, further validation is needed for practical application. The study underscores the importance of biomechanical properties at the measurement site and inter-individual variability and proposes the arterial pressure wave as a key factor in PPG signal formation.


Assuntos
Fotopletismografia , Humanos , Fotopletismografia/métodos , Masculino , Adulto , Feminino , Processamento de Sinais Assistido por Computador , Temperatura Cutânea/fisiologia , Adulto Jovem
3.
PLoS One ; 19(5): e0300373, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38696403

RESUMO

Captive and domestic animals are often required to engage in physical activity initiated or organised by humans, which may impact their body temperature, with consequences for their health and welfare. This is a particular concern for animals such as elephants that face thermoregulatory challenges because of their body size and physiology. Using infrared thermography, we measured changes in skin temperature associated with two types of physical activity in ten female Asian elephants (Elephas maximus) at an eco-tourism lodge in Nepal. Six elephants took part in an activity relatively unfamiliar to the elephants-a polo tournament-and four participated in more familiar ecotourism activities. We recorded skin temperatures for four body regions affected by the activities, as well as an average skin temperature. Temperature change was used as the response variable in the analysis and calculated as the difference in elephant temperature before and after activity. We found no significant differences in temperature change between the elephants in the polo-playing group and those from the non-polo playing group. However, for both groups, when comparing the average skin body temperature and several different body regions, we found significant differences in skin temperature change before and after activity. The ear pinna was the most impacted region and was significantly different to all other body regions. This result highlights the importance of this region in thermoregulation for elephants during physical activity. However, as we found no differences between the average body temperatures of the polo and non-polo playing groups, we suggest that thermoregulatory mechanisms can counteract the effects of both physical activities the elephants engaged in.


Assuntos
Elefantes , Temperatura Cutânea , Animais , Elefantes/fisiologia , Feminino , Temperatura Cutânea/fisiologia , Condicionamento Físico Animal/fisiologia , Temperatura Corporal/fisiologia , Regulação da Temperatura Corporal/fisiologia , Termografia/métodos
4.
Scand J Trauma Resusc Emerg Med ; 32(1): 35, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664809

RESUMO

BACKGROUND: Use of a vapor barrier in the prehospital care of cold-stressed or hypothermic patients aims to reduce evaporative heat loss and accelerate rewarming. The application of a vapor barrier is recommended in various guidelines, along with both insulating and wind/waterproof layers and an active external rewarming device; however, evidence of its effect is limited. This study aimed to investigate the effect of using a vapor barrier as the inner layer in the recommended "burrito" model for wrapping hypothermic patients in the field. METHODS: In this, randomized, crossover field study, 16 healthy volunteers wearing wet clothing were subjected to a 30-minute cooling period in a snow chamber before being wrapped in a model including an active heating source either with (intervention) or without (control) a vapor barrier. The mean skin temperature, core temperature, and humidity in the model were measured, and the shivering intensity and thermal comfort were assessed using a subjective questionnaire. The mean skin temperature was the primary outcome, whereas humidity and thermal comfort were the secondary outcomes. Primary outcome data were analyzed using analysis of covariance (ANCOVA). RESULTS: We found a higher mean skin temperature in the intervention group than in the control group after approximately 25 min (p < 0.05), and this difference persisted for the rest of the 60-minute study period. The largest difference in mean skin temperature was 0.93 °C after 60 min. Humidity levels outside the vapor barrier were significantly higher in the control group than in the intervention group after 5 min. There were no significant differences in subjective comfort. However, there was a consistent trend toward increased comfort in the intervention group compared with the control group. CONCLUSIONS: The use of a vapor barrier as the innermost layer in combination with an active external heat source leads to higher mean skin rewarming rates in patients wearing wet clothing who are at risk of accidental hypothermia. TRIAL REGISTRATION: ClinicalTrials.gov identifier: NCT05779722.


Assuntos
Estudos Cross-Over , Serviços Médicos de Emergência , Hipotermia , Reaquecimento , Humanos , Reaquecimento/métodos , Masculino , Feminino , Adulto , Serviços Médicos de Emergência/métodos , Hipotermia/prevenção & controle , Temperatura Cutânea/fisiologia , Adulto Jovem , Temperatura Baixa
5.
J Appl Physiol (1985) ; 136(6): 1364-1375, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38572540

RESUMO

Cold exposure increases blood pressure (BP) and salivary flow rate (SFR). Increased cold-induced SFR would be hypothesized to enhance oral nitrate delivery for reduction to nitrite by oral anaerobes and to subsequently elevate plasma [nitrite] and nitric oxide bioavailability. We tested the hypothesis that dietary nitrate supplementation would increase plasma [nitrite] and lower BP to a greater extent in cool compared with normothermic conditions. Twelve males attended the laboratory on four occasions. Baseline measurements were completed at 28°C. Subsequently, participants ingested 140 mL of concentrated nitrate-rich (BR; ∼13 mmol nitrate) or nitrate-depleted (PL) beetroot juice. Measurements were repeated over 3 h at either 28°C (Norm) or 20°C (Cool). Mean skin temperature was lowered compared with baseline in PL-Cool and BR-Cool. SFR was greater in BR-Norm, PL-Cool, and BR-Cool than PL-Norm. Plasma [nitrite] at 3 h was higher in BR-Cool (592 ± 239 nM) versus BR-Norm (410 ± 195 nM). Systolic BP (SBP) at 3 h was not different between PL-Norm (117 ± 6 mmHg) and BR-Norm (113 ± 9 mmHg). SBP increased above baseline at 1, 2, and 3 h in PL-Cool but not BR-Cool. These results suggest that BR consumption is more effective at increasing plasma [nitrite] in cool compared with normothermic conditions and blunts the rise in BP following acute cool air exposure, which might have implications for attenuating the increased cardiovascular strain in the cold.NEW & NOTEWORTHY Compared with normothermic conditions, acute nitrate ingestion increased plasma [nitrite], a substrate for oxygen-independent nitric oxide generation, to a greater extent during cool air exposure. Systolic blood pressure was increased during cool air exposure in the placebo condition with this cool-induced blood pressure increase attenuated after acute nitrate ingestion. These findings improve our understanding of environmental factors that influence nitrate metabolism and the efficacy of nitrate supplementation to lower blood pressure.


Assuntos
Pressão Sanguínea , Temperatura Baixa , Estudos Cross-Over , Nitratos , Humanos , Masculino , Nitratos/administração & dosagem , Nitratos/sangue , Pressão Sanguínea/efeitos dos fármacos , Pressão Sanguínea/fisiologia , Método Duplo-Cego , Adulto , Adulto Jovem , Nitritos/sangue , Óxido Nítrico/metabolismo , Suplementos Nutricionais , Beta vulgaris , Temperatura Cutânea/efeitos dos fármacos , Temperatura Cutânea/fisiologia , Sucos de Frutas e Vegetais
6.
J Tissue Viability ; 33(2): 305-311, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38553355

RESUMO

OBJECTIVE: this study was undertaken to evaluate the efficacy of multilayer polyurethane foam with silicone (MPF) compared to transparent polyurethane film (TPF) dressings in the control of heel skin microclimate (temperature and moisture) of hospitalized patients undergoing elective surgeries. METHOD: the study took of a secondary analysis of a randomized self-controlled trial, involving patients undergoing elective surgical procedure of cardiac and gastrointestinal specialties in a university hospital in southern Brazil, from March 2019 to February 2020. Patients served as their own control, with their heels randomly allocated to either TPF (control) or MPF (intervention). Skin temperature was measured using a digital infrared thermometer; and moisture determined through capacitance, at the beginning and end of surgery. The study was registered in the Brazilian Registry of Clinical Trials: RBR-5GKNG5. RESULTS: significant difference in the microclimate variables were observed when the groups (intervention and control) and the timepoint of measurement (beginning and end of surgery) were compared. When assessing temperature, an increase (+3.3 °C) was observed with TPF and a decrease (-7.4 °C) was recorded with MPF. Regarding skin moisture, an increase in moisture (+14.6 AU) was recorded with TPF and a slight decrease (-0.3 AU) with MPF. CONCLUSIONS: The findings of this study suggest that MPF is more effective than TPF in controlling skin microclimate (temperature and moisture) in heels skin of hospitalized patients undergoing elective surgeries. However, this control should be better investigated in other studies.


Assuntos
Calcanhar , Microclima , Humanos , Feminino , Masculino , Pessoa de Meia-Idade , Brasil , Idoso , Temperatura Cutânea/fisiologia , Bandagens/normas , Bandagens/estatística & dados numéricos , Poliuretanos , Adulto
7.
Mater Horiz ; 11(10): 2428-2437, 2024 05 20.
Artigo em Inglês | MEDLINE | ID: mdl-38441176

RESUMO

Monitoring of arterial blood pressure via cuffless pulse waveform measurement at the wrist has an important clinical value for the early diagnosis and prevention of cardiovascular disease. However, accurate measurement of the radial pulse waveform is challenging owing to its subtle, wideband, and preload-dependent variation characteristics. Evidence shows that uncertainties or variations of wearing pressure and skin temperature can cause artifact signals in wrist pulse measurements, thus degrading blood pressure estimate accuracy and hindering precise clinical diagnosis. Herein, we report a flexible multisensory pulse sensor utilizing natural piezo-thermic transduction of human skin in conjunction with thin-film thermistors for the accurately measuring radial artery pulse waves with high fidelity and good anti-artifact performance. The flexible pulse sensor achieved a wide pressure measuring range (228.2 kPa), low detection limit (4 Pa), good linearity (R2 = 0.999), low hysteresis (2.45%), fast response (88 ms), and good durability and stability, thereby enabling accurate pulse measurement with high fidelity. The pulse sensor also monolithically integrated the simultaneous detections of skin temperature and wearing pressure for resisting artifact effects in pulse measurements. Through the fusion of multiple features extracted from the pulse waveform, wearing pressure, skin temperature and user's personal physical characteristics using an efficient multilayer perceptron, blood pressure is accurately estimated and good generalizability is achieved.


Assuntos
Dispositivos Eletrônicos Vestíveis , Humanos , Masculino , Temperatura Cutânea/fisiologia , Pressão Sanguínea/fisiologia , Determinação da Pressão Arterial/métodos , Determinação da Pressão Arterial/instrumentação , Adulto , Feminino , Pulso Arterial
8.
Int J Occup Saf Ergon ; 30(2): 587-598, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38509715

RESUMO

Objectives. This study explores the effects of temperature steps on thermal responses to understand abrupt temperature shifts faced by heat-exposed workers during winter. Methods. Three temperature step changes with three phases (S20: 20-40-20 °C, S30: 10-40-10 °C, S40: 0-40-0 °C) were conducted. Phase 1 took 30 min, phase 2 took 60 min and phase 3 took 40 min. Eleven participants remained sedentary throughout the experiment, and physiological responses, thermal perception and self-reported health symptoms were recorded. Results. In temperature up steps, steady skin temperature and sweating onset were delayed, and heart rate dropped by 10 bpm from S20 to S40. In temperature down steps to cold conditions, individuals transitioned from thermal comfort to discomfort and eventually cold strain. Blood pressure increased in temperature down steps, correlating with temperature step magnitudes. Thermal responses to temperature steps of equal magnitude but opposite directions were asymmetries, which weakened as step magnitude increased. Thermal perceptions responded faster than physiological changes after temperature steps, while self-reported health symptoms lagged behind physiological responses. Conclusions. These findings contribute to expanding basic data to understand the effects of temperature step magnitude and direction.


Assuntos
Temperatura Baixa , Frequência Cardíaca , Temperatura Alta , Temperatura Cutânea , Humanos , Masculino , Temperatura Cutânea/fisiologia , Frequência Cardíaca/fisiologia , Adulto , Pressão Sanguínea/fisiologia , Sudorese/fisiologia , Feminino , Percepção/fisiologia , Sensação Térmica/fisiologia , Adulto Jovem
9.
Med Sci Sports Exerc ; 56(6): 1140-1150, 2024 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-38233977

RESUMO

PURPOSE: Muscle mechanics is paramount in our understanding of motor performance. However, little is known regarding the sensitivity of fascicle dynamics and connective tissues stiffness to exercise duration and ambient temperature during running, both increasing muscle temperature. This study aimed to determine gastrocnemius medialis (GM) fascicle dynamics in vivo during running in temperate and hot conditions, as well as muscle-tendon unit responses. METHODS: Using ultrafast ultrasound, 15 participants (8 men, 7 women; 26 ± 3 yr) were tested before, during (2 and 40 min), and after a running task (40 min at 10 km·h -1 ) in temperate (TEMP; ~23°C) and hot (HOT: ~38°C) conditions. RESULTS: Although core, skin temperatures, and heart rate increased from the beginning to the end of the exercise and in a larger extent in HOT than TEMP ( P < 0.001), the physiological stress elicited did not alter running temporal parameters and GM fascicle operating lengths, with similar behavior of the fascicles on their force-length relationship, over time (2 vs 40 min) or across condition (TEMP vs HOT; P ≥ 0.248). Maximal voluntary force production did not reported statistical changes after exercise ( P = 0.060), and the connective tissues stiffness measured (i.e., passive muscle and stiffness of the series-elastic elements) did not show neither time ( P ≥ 0.281), condition ( P ≥ 0.256) nor time-condition interaction ( P ≥ 0.465) effect. CONCLUSIONS: This study revealed that prolonged running exercise does not alter muscle-tendon unit properties and interplay, which are not influenced by ambient temperature. These findings may rule out potential detrimental effects of heat on muscle properties and encourage further investigations on longer and more intense running exercise.


Assuntos
Temperatura Alta , Músculo Esquelético , Corrida , Ultrassonografia , Humanos , Masculino , Corrida/fisiologia , Feminino , Adulto , Músculo Esquelético/fisiologia , Músculo Esquelético/diagnóstico por imagem , Frequência Cardíaca/fisiologia , Tendões/fisiologia , Tendões/diagnóstico por imagem , Adulto Jovem , Temperatura Cutânea/fisiologia , Fatores de Tempo , Temperatura Corporal/fisiologia , Tecido Conjuntivo/fisiologia
10.
Eur J Appl Physiol ; 124(5): 1523-1534, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38150009

RESUMO

PURPOSE: Cold-induced vasodilation (CIVD) is an oscillatory rise in blood flow to glabrous skin that occurs in cold-exposed extremities. Dietary flavanols increase bioavailable nitric oxide, a proposed mediator of CIVD through active vasodilation and/or withdrawal of sympathetic vascular smooth muscle tone. However, no studies have examined the effects of flavanol intake on extremity skin perfusion during cold exposure. We tested the hypothesis that acute and 8-day flavanol supplementation would augment CIVD during single-digit cold water immersion (CWI). METHODS: Eleven healthy adults (24 ± 6 years; 10 M/1F) ingested cocoa flavanols (900 mg/day) or caffeine- and theobromine-matched placebo for 8 days in a double-blind, randomized, crossover design. On Days 1 and 8, CIVD was assessed 2 h post-treatment. Subjects immersed their 3rd finger in warm water (42 °C) for 15 min before CWI (4 °C) for 30 min, during which nail bed and finger pad skin temperature were measured. RESULTS: Flavanol ingestion had no effect on CIVD frequency (Day 1, Flavanol: 3 ± 2 vs. Placebo: 3 ± 2; Day 8, Flavanol: 3 ± 2 vs. Placebo: 3 ± 1) or amplitude (Day 1, Flavanol: 4.3 ± 1.7 vs. Placebo: 4.9 ± 2.6 °C; Day 8, Flavanol: 3.9 ± 1.9 vs. Placebo: 3.9 ± 2.0 °C) in the finger pad following acute or 8-day supplementation (P > 0.05). Furthermore, average, nadir, and apex finger pad temperatures during CWI were not different between treatments on Days 1 or 8 of supplementation (P > 0.05). Similarly, no differences in CIVD parameters were observed in the nail bed following supplementation (P > 0.05). CONCLUSION: These data suggest that cocoa flavanol ingestion does not alter finger CIVD. Clinical Trial Registration Clinicaltrials.gov Identifier: NCT04359082. April 24, 2020.


Assuntos
Temperatura Baixa , Suplementos Nutricionais , Vasodilatação , Humanos , Masculino , Feminino , Vasodilatação/efeitos dos fármacos , Vasodilatação/fisiologia , Adulto , Método Duplo-Cego , Adulto Jovem , Estudos Cross-Over , Temperatura Cutânea/efeitos dos fármacos , Temperatura Cutânea/fisiologia , Cacau , Flavonóis/farmacologia , Flavonóis/administração & dosagem , Pele/irrigação sanguínea , Pele/efeitos dos fármacos , Chocolate
11.
Nature ; 614(7949): 725-731, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36755097

RESUMO

Temperature is a fundamental sensory modality separate from touch, with dedicated receptor channels and primary afferent neurons for cool and warm1-3. Unlike for other modalities, however, the cortical encoding of temperature remains unknown, with very few cortical neurons reported that respond to non-painful temperature, and the presence of a 'thermal cortex' is debated4-8. Here, using widefield and two-photon calcium imaging in the mouse forepaw system, we identify cortical neurons that respond to cooling and/or warming with distinct spatial and temporal response properties. We observed a representation of cool, but not warm, in the primary somatosensory cortex, but cool and warm in the posterior insular cortex (pIC). The representation of thermal information in pIC is robust and somatotopically arranged, and reversible manipulations show a profound impact on thermal perception. Despite being positioned along the same one-dimensional sensory axis, the encoding of cool and that of warm are distinct, both in highly and broadly tuned neurons. Together, our results show that pIC contains the primary cortical representation of skin temperature and may help explain how the thermal system generates sensations of cool and warm.


Assuntos
Córtex Insular , Neurônios , Temperatura Cutânea , Córtex Somatossensorial , Animais , Camundongos , Temperatura Baixa , Neurônios/fisiologia , Córtex Somatossensorial/citologia , Córtex Somatossensorial/fisiologia , Percepção do Tato/fisiologia , Temperatura Alta , Temperatura Cutânea/fisiologia , Análise Espaço-Temporal , Córtex Insular/citologia , Córtex Insular/fisiologia
12.
J Therm Biol ; 104: 103174, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35180960

RESUMO

PURPOSE: This study investigated the influence of whole body cooling on local thermal sensitivity to warm (40°C) and cold (20°C) stimuli in 10 young (age: 24 ± 2 yrs) and 10 older males (age: 69 ± 4 yrs). METHODS: Local warm and cold sensitivity was assessed at eight body regions using a 25 cm2 pressure controlled thermal probe after 40 min of whole body exposure to a thermoneutral (NEUT: 25°C/40% RH) and a cold (COLD: 12°C/50% RH) environment. Gastrointestinal temperature (Tgi), mean and local skin temperature, heart rate, whole body thermal sensation and comfort, and skin blood flow were also measured. RESULTS: Whole body cooling blunted local cold sensitivity but warm sensitivity was maintained in both age groups. Furthermore, a significant age-related decline (from young to older group) in sensitivity to a warm stimulus was observed in both NEUT and COLD conditions. Older males also had a greater ΔTgi compared to the young but had similar thermal sensation and comfort responses. CONCLUSION: The observed interaction effect of local cold stimulation and whole body cooling may be related to both stimuli triggering similar TRP channels, whereas the lack of interaction between local warm stimuli and whole body cooling may be related to these two stimuli triggering different TRP channels. The findings reiterate the potential thermoregulatory risks (e.g. cold injury and hypothermia) associated with ageing, even with such short exposure times.


Assuntos
Envelhecimento/fisiologia , Temperatura Baixa , Sensação Térmica/fisiologia , Adulto , Idoso , Regulação da Temperatura Corporal , Feminino , Frequência Cardíaca/fisiologia , Humanos , Masculino , Temperatura Cutânea/fisiologia , Adulto Jovem
13.
J Therm Biol ; 104: 103187, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-35180966

RESUMO

Plyometric training has been used in several sports and fitness programs to improve jumping ability and explosive strength, both in individual and team sports. Eccentric muscle actions, such as those performed during plyometric jumps, induce muscle damage and consequently a rise in skin temperature (Tsk). Thus, the purpose of this study is to assess the response of infrared thermography measurement as an indirect marker of muscle damage after a protocol of plyometric jumps in physically active subjects. Therefore, for the aim of this study ten male subjects with no previous experience in plyometric training participated in the research (age 22.5 ± 3.3 years, weight 71.7 ± 11.0 kg, height 171.1 ± 5.3 cm, and fat mass 15.5 ± 4.7%). To assess the muscle damage, countermovement jump (CMJ), creatine kinase (CK), delayed-onset muscle soreness (DOMS) and infrared thermography (IRT) were measured at 24, 48, and 72 h after plyometric exercise. The acute exercise protocol of plyometric jumps induced muscle damage, as shown by the CK and DOMS (24 and 48 h, p < 0.05) but no statistical difference was shown between the moments analyzed in Tsk (warm zone). Nevertheless, when comparing baseline to 48h, a moderate effect was found in the Tsk (warm zone) for anterior right thigh (ES = 1.1) and posterior left thigh (ES = 0.9) and large effect was found for anterior left thigh (ES = 1.4) and posterior right thigh (ES = 1.3). A moderate effect in the Tsk (warm zone) was found for posterior right and left thigh (ES = 0.9 and ES = 1.1, respectively) when comparing baseline to 72h of IRT. These results suggest that a plyometric jumping session alters CK and DOMS, as well as the thigh's skin temperature in an evident way, bringing up a possible relation with markers of muscle damage.


Assuntos
Músculo Esquelético/fisiopatologia , Exercício Pliométrico , Temperatura Cutânea/fisiologia , Termografia , Adulto , Biomarcadores/análise , Creatina Quinase/sangue , Humanos , Raios Infravermelhos , Extremidade Inferior/fisiologia , Masculino , Músculo Esquelético/diagnóstico por imagem , Músculo Esquelético/lesões , Mialgia/etiologia , Mialgia/fisiopatologia , Adulto Jovem
14.
Clin Neurophysiol ; 134: 81-87, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34991016

RESUMO

OBJECTIVE: To evaluate the activity of cold Aδ-type fibers to thermal stimuli above human skin temperature (i.e., >32 °C). METHODS: Twenty young adults aged 20-24 years participated in this study. The cold-detection threshold was measured from a basal temperature of 40 °C using an adaptive staircase method with high-speed cooling ramps (170 °C/s). A total of 150 stimulations at 36 °C, 32 °C, 28 °C, 24 °C, 20 °C, 16 °C, 12 °C, 8 °C, 4 °C and 0 °C (15 each) were performed. After each stimulation, subjects estimated the intensity of cold sensation using a visual analog scale, and evoked potentials were recorded. RESULTS: The average cold-detection threshold was 35 °C (SD = 1.8). Regardless of the stimulation temperature, subjects reported a cooling sensation. Interestingly, reported increments in sensation were prominent for stimulation temperatures between 32 °C and 20 °C, but below this latter temperature sensations varied only very slightly. Evoked potential recordings revealed that decreasing temperature stimuli from a baseline of 40 °C induced a previously unreported N2P2 component with a mean N2 peak latency of 275 ms (SD = 13.1). The peak-to-peak amplitude of the N2P2 complex increased as the intensity of the cooling stimulation increased, exhibiting a profile comparable to subject-perceived intensity, namely, a major increase up to 20 °C, followed by a plateau to 0 °C. CONCLUSIONS: The cool sensations reported by subjects were likely conveyed by Aδ fibers rather than by slow-conducting C fibers. Moreover, our rapid stimulation technique starting from a high temperature (40 °C) was capable of a) generating cold sensations at stimulation temperatures between 36 °C and 32 °C, and b) revealing the optimal activation range of Aδ fibers (20 °C-28 °C). Any decrease in temperature below this range did not result in a significant increase in sensation and thus probably did not evoke a significant increase in Aδ fiber activity. SIGNIFICANCE: The regular assessment of cold sensation in peripheral neuropathies (i.e., with temperatures below 32 °C), could be completed by investigating cold-detection thresholds at temperatures ranging from 40 °C to 32 °C. Indeed, the absolute threshold of cold perception appears to start at 35 °C. Changes in the activation threshold of cold fibers were more easily detectable at this level.


Assuntos
Potenciais Somatossensoriais Evocados/fisiologia , Fibras Nervosas/fisiologia , Temperatura Cutânea/fisiologia , Sensação Térmica/fisiologia , Feminino , Humanos , Masculino , Adulto Jovem
15.
Appl Physiol Nutr Metab ; 47(2): 195-205, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34582724

RESUMO

Cold stress impairs fine and gross motor movements. Although peripheral effects of muscle cooling on performance are well understood, less is known about central mechanisms. This study characterized corticospinal and spinal excitability during surface cooling, reducing skin (Tsk) and esophageal (Tes) temperatures. Ten subjects (3 females) wore a liquid-perfused suit and were cooled (9 °C perfusate, 90 min) and rewarmed (41 °C perfusate, 30 min). Transcranial magnetic stimulation (eliciting motor evoked potentials [MEPs]), as well as transmastoid (eliciting cervicomedullary evoked potentials [CMEPs]) and brachial plexus (eliciting maximal compound motor action potentials [Mmax]) electrical stimulation, were applied at baseline, every 20 min during cooling, and following rewarming. Sixty minutes of cooling reduced Tsk by 9.6 °C (P < 0.001), but Tes remained unchanged (P = 0.92). Tes then decreased by ∼0.6 °C in the next 30 min of cooling (P < 0.001). Eight subjects shivered. During rewarming, shivering was abolished, and Tsk returned to baseline, while Tes did not increase. During cooling and rewarming, Mmax, MEP, and MEP/Mmax remained unchanged from baseline. However, CMEP and CMEP/Mmax increased during cooling by ∼85% and 79% (P < 0.001), respectively, and remained elevated post-rewarming. The results suggest that spinal excitability is facilitated by reduced Tsk during cooling and reduced Tes during warming, while corticospinal excitability remains unchanged. ClinicalTrials.gov ID: NCT04253730. Novelty: This is the first study to characterize corticospinal and spinal excitability during whole-body cooling and rewarming in humans. Whole body cooling did not affect corticospinal excitability. Spinal excitability was facilitated during reductions in both skin and core temperatures.


Assuntos
Temperatura Corporal/fisiologia , Crioterapia , Potencial Evocado Motor/fisiologia , Temperatura Cutânea/fisiologia , Adulto , Cotovelo/fisiologia , Estimulação Elétrica , Eletromiografia , Esôfago/fisiologia , Feminino , Humanos , Masculino , Músculo Esquelético/fisiologia , Tratos Piramidais/fisiologia , Reaquecimento , Coluna Vertebral/fisiologia , Estimulação Magnética Transcraniana
16.
Front Endocrinol (Lausanne) ; 12: 785175, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34867829

RESUMO

Background: Thyroid hormones are essential for the full thermogenic response of brown adipose tissue (BAT) and have been implicated in dermal temperature regulation. Nevertheless, persistent cold-intolerance exists among a substantial proportion of hypothyroid patients on adequate levothyroxine (LT4) substitution. Materials and Methods: To assess if skin temperature and activation of BAT during treatment with liothyronine (LT3) differs from that of LT4 treatment, fifty-nine female hypothyroid patients with residual symptoms on LT4 or LT4/LT3 combination therapy were randomly assigned in a non-blinded crossover study to receive monotherapy with LT4 or LT3 for 12 weeks each. Change in supraclavicular (SCV) skin temperature overlying BAT, and sternal skin temperature not overlying BAT, during rest and cold stimulation were assessed by infrared thermography (IRT). In addition, abundance of exosomal miR-92a, a biomarker of BAT activation, was estimated as a secondary outcome. Results: Cold stimulated skin temperatures decreased less with LT3 vs. LT4 in both SCV (mean 0.009°C/min [95% CI: 0.004, 0.014]; P<0.001) and sternal areas (mean 0.014°C/min [95% CI: 0.008, 0.020]; P<0.001). No difference in serum exosomal miR-92a abundance was observed between the two treatment groups. Conclusion: LT3 may reduce dermal heat loss. Thermography data suggested increased BAT activation in hypothyroid patients with cold-intolerance. However, this finding was not corroborated by assessment of the microRNA biomarker of BAT activation. Clinical Trial Registration: ClinicalTrials.gov, identifier NCT03627611.


Assuntos
Tecido Adiposo Marrom/metabolismo , Hipotireoidismo/tratamento farmacológico , Hipotireoidismo/metabolismo , Temperatura Cutânea/fisiologia , Termogênese/fisiologia , Tri-Iodotironina/uso terapêutico , Tecido Adiposo Marrom/efeitos dos fármacos , Adulto , Estudos Cross-Over , Feminino , Humanos , Hipotireoidismo/epidemiologia , Pessoa de Meia-Idade , Noruega/epidemiologia , Temperatura Cutânea/efeitos dos fármacos , Termogênese/efeitos dos fármacos , Resultado do Tratamento , Tri-Iodotironina/farmacologia
17.
Cell Rep Med ; 2(10): 100408, 2021 10 19.
Artigo em Inglês | MEDLINE | ID: mdl-34755128

RESUMO

The Scandinavian winter-swimming culture combines brief dips in cold water with hot sauna sessions, with conceivable effects on body temperature. We study thermogenic brown adipose tissue (BAT) in experienced winter-swimming men performing this activity 2-3 times per week. Our data suggest a lower thermal comfort state in the winter swimmers compared with controls, with a lower core temperature and absence of BAT activity. In response to cold, we observe greater increases in cold-induced thermogenesis and supraclavicular skin temperature in the winter swimmers, whereas BAT glucose uptake and muscle activity increase similarly to those of the controls. All subjects demonstrate nocturnal reduction in supraclavicular skin temperature, whereas a distinct peak occurs at 4:30-5:30 a.m. in the winter swimmers. Our data leverage understanding of BAT in adult human thermoregulation, suggest both heat and cold acclimation in winter swimmers, and propose winter swimming as a potential strategy for increasing energy expenditure.


Assuntos
Tecido Adiposo Marrom/fisiologia , Temperatura Baixa , Estações do Ano , Natação/fisiologia , Termogênese/fisiologia , Tecido Adiposo Marrom/diagnóstico por imagem , Adulto , Ritmo Circadiano/fisiologia , Hormônios/sangue , Humanos , Imageamento por Ressonância Magnética , Masculino , Percepção , Tomografia por Emissão de Pósitrons , Temperatura Cutânea/fisiologia , Termografia , Adulto Jovem
18.
J Therm Biol ; 100: 103045, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34503792

RESUMO

Uncertainty propagation analysis in the Fiala thermophysiological model is performed by the Monte Carlo Method. The uncertainties of the output quantities of the passive system, due to imported uncertainties in the coefficients of the control equations of the active system, caused by the variation of the experimental data, are computed. The developed and implemented in-house code is accordingly validated. The effect of the input uncertainties, in each of the four main responses (shivering, vasodilatation, vasoconstriction, sweating) of the active system, is separately examined by simulating the human exposure from neutral conditions to cold and hot environments. It is predicted that the maximum output uncertainties of the response mechanisms may be of the same order of magnitude as the imported ones, while the corresponding maximum uncertainties in core and skin temperatures always remain less than 2%. The maximum absolute deviations of the rectal (core) temperatures from their estimated mean values may be up to 0.72 °C and 0.22 °C, due to input uncertainties in shivering and sweating respectively, while the corresponding deviations due to uncertainties in vasomotion processes are negligible. The deviations, particularly the ones due to shivering, are significant, since differences of a few tenths of a degree may have large impact in human health. The maximum absolute deviations of the skin temperatures are 0.42 °C in the hands due to uncertainties in shivering and 0.69 °C in the feet due to uncertainties in vasodilatation. These deviations are less significant than the core ones, but they may still affect human thermal sensation and comfort. The present analysis provides a better insight in the dynamic response of the model and indicates which response mechanism needs to be further investigated by more accurate estimates in order to improve model reliability. It can be also applied in other human thermophysiological models.


Assuntos
Modelos Teóricos , Estremecimento , Termodinâmica , Humanos , Método de Monte Carlo , Temperatura Cutânea/fisiologia , Incerteza
19.
J Physiol Anthropol ; 40(1): 12, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34488878

RESUMO

BACKGROUND: Facial cooling (FC) is effective in improving endurance exercise performance in hot environments. In this study, we evaluated the impact of intermittent short-lasting FC on the ratings of perceived exertion (RPE) during exercise. METHODS: Ten healthy men performed 40 continuous minutes of ergometric cycle exercise at 65% of the peak heart rate in a climatic chamber controlled at an ambient temperature of 35 °C and a relative humidity of 50%. In the control (CONT) trial, the participants performed the exercise without FC. In two cooling trials, each participant underwent 10 s of FC at 2- (FC2) and 4-min (FC4) intervals while continuing to exercise. FC was achieved by applying two soft-gel packs (cooled to 0 °C) directly and bilaterally on the forehead, eyes, and cheeks. In another cooling trial, 10 s of FC was performed at 2-min intervals using two soft-gel packs cooled to 20 °C (FC2-20). RESULTS: The RPE values in the FC4 trial were significantly lower than those in the CONT trial at 20 min (FC4, 11.6 ± 2.2 points; CONT, 14.2 ± 1.3 points; P < 0.01). Further, significant differences in the RPE values were observed between the FC4 and CONT trials at 5-15 min and 25-40 min (P < 0.05). RPE values were also significantly lower in the FC2 trial than in the CONT trial (5-40 min). Although the RPE values in the FC2-20 trial were significantly lower (5-10 min; 15-20 min) than those in the CONT trial, there were no significant differences in the RPE between the FC2-20 and CONT trials at 25-40 min. At 35 min, the RPE values were significantly higher in the FC2-20 trial than in the FC2 trial (P < 0.05). CONCLUSION: Intermittent short-lasting FC was associated with a decrease in RPE, with shorter intervals and lower temperatures eliciting greater attenuation of increase in the RPE.


Assuntos
Regulação da Temperatura Corporal/fisiologia , Temperatura Baixa , Face/fisiologia , Esforço Físico/fisiologia , Temperatura Cutânea/fisiologia , Adulto , Desempenho Atlético/fisiologia , Temperatura Alta , Humanos , Masculino , Adulto Jovem
20.
Sci Rep ; 11(1): 12059, 2021 06 08.
Artigo em Inglês | MEDLINE | ID: mdl-34103607

RESUMO

Facial infra-red imaging (IRI) is a contact-free technique complimenting the traditional psychophysiological measures to characterize physiological profile. However, its full potential in affective research is arguably unmet due to the analytical challenges it poses. Here we acquired facial IRI data, facial expressions and traditional physiological recordings (heart rate and skin conductance) from healthy human subjects whilst they viewed a 20-min-long unedited emotional movie. We present a novel application of motion correction and the results of spatial independent component analysis of the thermal data. Three distinct spatial components are recovered associated with the nose, the cheeks and respiration. We first benchmark this methodology against a traditional nose-tip region-of-interest based technique showing an expected similarity of signals extracted by these methods. We then show significant correlation of all the physiological responses across subjects, including the thermal signals, suggesting common dynamic shifts in emotional state induced by the movie. In sum, this study introduces an innovative approach to analyse facial IRI data and highlights the potential of thermal imaging to robustly capture emotion-related changes induced by ecological stimuli.


Assuntos
Face/fisiologia , Temperatura Cutânea/fisiologia , Adulto , Feminino , Humanos , Masculino
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA