Anal Bioanal Chem ; 414(8): 2607-2618, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35091761

RESUMO

The lateral flow assay (LFA) is one of the most popular technologies on the point-of-care diagnostics market due to its low cost and ease of use, with applications ranging from pregnancy to environmental toxins to infectious disease. While the use of these tests is relatively straightforward, significant development time and effort are required to create tests that are both sensitive and specific. Workflows to guide the LFA development process exist but moving from target selection to an LFA that is ready for field testing can be labor intensive, resource heavy, and time consuming. To reduce the cost and the duration of the LFA development process, we introduce a novel development platform centered on the flexibility, speed, and throughput of an automated robotic liquid handling system. The system comprises LFA-specific hardware and software that enable large optimization experiments with discrete and continuous variables such as antibody pair selection or reagent concentration. Initial validation of the platform was demonstrated during development of a malaria LFA but was readily expanded to encompass development of SARS-CoV-2 and Mycobacterium tuberculosis LFAs. The validity of the platform, where optimization experiments are run directly on LFAs rather than in solution, was based on a direct comparison between the robotic system and a more traditional ELISA-like method. By minimizing hands-on time, maximizing experiment size, and enabling improved reproducibility, the robotic system improved the quality and quantity of LFA assay development efforts.


Assuntos
COVID-19/diagnóstico , Imunoensaio/instrumentação , Malária/diagnóstico , Testes Imediatos , Tuberculose/diagnóstico , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/instrumentação , Desenho de Equipamento , Humanos , Imunoensaio/economia , Mycobacterium tuberculosis/isolamento & purificação , Plasmodium/isolamento & purificação , Testes Imediatos/economia , Reprodutibilidade dos Testes , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade , Fatores de Tempo
2.
J Immunol Methods ; 500: 113182, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-34762914

RESUMO

Serology tests for SARS-CoV-2 have proven to be important tools to fight against the COVID-19 pandemic. These serological tests can be used in low-income and remote areas for patient contact tracing, epidemiologic studies and vaccine efficacy evaluations. In this study, we used a semi-stable mammalian episomal expression system to produce high quantities of the receptor-binding domain-RBD of SARS-CoV-2 in a simple and very economical way. The recombinant antigen was tested in an in-house IgG ELISA for COVID-19 with a panel of human sera. A performance comparison of this serology test with a commercial test based on the full-length spike protein showed 100% of concordance between tests. Thus, this serological test can be an attractive and inexpensive option in scenarios of limited resources to face the COVID-19 pandemic.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/fisiologia , Glicoproteína da Espícula de Coronavírus/metabolismo , Enzima de Conversão de Angiotensina 2/metabolismo , COVID-19/economia , Teste Sorológico para COVID-19/economia , Custos e Análise de Custo , Ensaio de Imunoadsorção Enzimática , Engenharia Genética , Humanos , Imunoglobulina G/genética , Imunoglobulina G/metabolismo , Ligação Proteica , Domínios e Motivos de Interação entre Proteínas/genética , Glicoproteína da Espícula de Coronavírus/genética
4.
Sci Rep ; 11(1): 17793, 2021 09 07.
Artigo em Inglês | MEDLINE | ID: mdl-34493744

RESUMO

The rapid identification and isolation of infected individuals remains a key strategy for controlling the spread of SARS-CoV-2. Frequent testing of populations to detect infection early in asymptomatic or presymptomatic individuals can be a powerful tool for intercepting transmission, especially when the viral prevalence is low. However, RT-PCR testing-the gold standard of SARS-CoV-2 diagnosis-is expensive, making regular testing of every individual unfeasible. Sample pooling is one approach to lowering costs. By combining samples and testing them in groups the number of tests required is reduced, substantially lowering costs. Here we report on the implementation of pooling strategies using 3-d and 4-d hypercubes to test a professional sports team in South Africa. We have shown that infected samples can be reliably detected in groups of 27 and 81, with minimal loss of assay sensitivity for samples with individual Ct values of up to 32. We report on the automation of sample pooling, using a liquid-handling robot and an automated web interface to identify positive samples. We conclude that hypercube pooling allows for the reliable RT-PCR detection of SARS-CoV-2 infection, at significantly lower costs than lateral flow antigen (LFA) tests.


Assuntos
Teste de Ácido Nucleico para COVID-19/métodos , COVID-19/diagnóstico , Ensaios de Triagem em Larga Escala/métodos , SARS-CoV-2/isolamento & purificação , Manejo de Espécimes/métodos , Antígenos Virais/isolamento & purificação , Atletas , COVID-19/sangue , COVID-19/virologia , Teste de Ácido Nucleico para COVID-19/economia , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/métodos , Redução de Custos , Ensaios de Triagem em Larga Escala/economia , Humanos , RNA Viral/isolamento & purificação , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , África do Sul , Manejo de Espécimes/economia , Medicina Esportiva/economia , Medicina Esportiva/métodos
5.
Anal Biochem ; 631: 114360, 2021 10 15.
Artigo em Inglês | MEDLINE | ID: mdl-34481802

RESUMO

To monitor the levels of protecting antibodies raised in the population in response to infection and/or to immunization with SARS-CoV-2, we need a technique that allows high throughput and low-cost quantitative analysis of human IgG antibodies reactive against viral antigens. Here we describe an ultra-fast, high throughput and inexpensive assay to detect SARS-CoV-2 seroconversion in humans. The assay is based on Ni2+ magnetic particles coated with His tagged SARS-CoV-2 antigens. A simple and inexpensive 96 well plate magnetic extraction/homogenization process is described which allows the simultaneous analysis of 96 samples and delivers results in 7 min with high accuracy.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Imunoglobulina G/sangue , SARS-CoV-2/isolamento & purificação , Anticorpos Antivirais/imunologia , Antígenos Virais/sangue , Antígenos Virais/imunologia , COVID-19/sangue , COVID-19/imunologia , Teste Sorológico para COVID-19/economia , Ensaio de Imunoadsorção Enzimática/economia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/imunologia , Imãs/química , Níquel/química , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Soroconversão , Fatores de Tempo
6.
Med Microbiol Immunol ; 210(5-6): 263-275, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34415422

RESUMO

A versatile portfolio of diagnostic tests is essential for the containment of the severe acute respiratory syndrome coronavirus type 2 (SARS-CoV-2) pandemic. Besides nucleic acid-based test systems and point-of-care (POCT) antigen (Ag) tests, quantitative, laboratory-based nucleocapsid Ag tests for SARS-CoV-2 have recently been launched. Here, we evaluated four commercial Ag tests on automated platforms and one POCT to detect SARS-CoV-2. We evaluated PCR-positive (n = 107) and PCR-negative (n = 303) respiratory swabs from asymptomatic and symptomatic patients at the end of the second pandemic wave in Germany (February-March 2021) as well as clinical isolates EU1 (B.1.117), variant of concern (VOC) Alpha (B.1.1.7) or Beta (B.1.351), which had been expanded in a biosafety level 3 laboratory. The specificities of automated SARS-CoV-2 Ag tests ranged between 97.0 and 99.7% (Lumipulse G SARS-CoV-2 Ag (Fujirebio): 97.03%, Elecsys SARS-CoV-2 Ag (Roche Diagnostics): 97.69%; LIAISON® SARS-CoV-2 Ag (Diasorin) and SARS-CoV-2 Ag ELISA (Euroimmun): 99.67%). In this study cohort of hospitalized patients, the clinical sensitivities of tests were low, ranging from 17.76 to 52.34%, and analytical sensitivities ranged from 420,000 to 25,000,000 Geq/ml. In comparison, the detection limit of the Roche Rapid Ag Test (RAT) was 9,300,000 Geq/ml, detecting 23.58% of respiratory samples. Receiver-operating-characteristics (ROCs) and Youden's index analyses were performed to further characterize the assays' overall performance and determine optimal assay cutoffs for sensitivity and specificity. VOCs carrying up to four amino acid mutations in nucleocapsid were detected by all five assays with characteristics comparable to non-VOCs. In summary, automated, quantitative SARS-CoV-2 Ag tests show variable performance and are not necessarily superior to a standard POCT. The efficacy of any alternative testing strategies to complement nucleic acid-based assays must be carefully evaluated by independent laboratories prior to widespread implementation.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/virologia , SARS-CoV-2/isolamento & purificação , Antígenos Virais/imunologia , Automação/economia , Automação/métodos , COVID-19/diagnóstico , Teste Sorológico para COVID-19/economia , Estudos de Coortes , Reações Falso-Negativas , Alemanha , Humanos , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Sensibilidade e Especificidade
7.
J Med Virol ; 93(12): 6512-6518, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34241912

RESUMO

There is a great demand for more rapid tests for SARS-CoV-2 detection to reduce waiting time, boost public health strategies for combating disease, decrease costs, and prevent overwhelming laboratory capacities. This study was conducted to assess the performance of 10 lateral flow device viral antigen immunoassays for the detection of SARS-CoV-2 in nasopharyngeal swab specimens. We analyzed 231 nasopharyngeal samples collected from October 2020 to December 2020, from suspected COVID-19 cases and contacts of positive cases at Biotechnology Research Center laboratories, Tripoli, Libya. The performance of 10 COVID-19 Antigen (Ag) rapid test devices for the detection of SARS-CoV-2 antigen was compared to a quantitative reverse transcription-polymerase chain reaction (RT-qPCR). In this study, 161 cases had symptoms consistent with COVID-19. The mean duration from symptom onset was 6.6 ± 4.3 days. The median cycle threshold (Ct ) of positive samples was 25. Among the 108 positive samples detected by RT-qPCR, the COVID-19 antigen (Ag) tests detected 83 cases correctly. All rapid Ag test devices used in this study showed 100% specificity. While tests from six manufacturers had an overall sensitivity range from 75% to 100%, the remaining four tests had a sensitivity of 50%-71.43%. Sensitivity during the first 6 days of symptoms and in samples with high viral loads (Ct < 25), was 100% in all but two of the test platforms. False-negative samples had a median Ct of 34 and an average duration of onset of symptoms of 11.3 days (range = 5-20 days). Antigen test diagnosis has high sensitivity and specificity in early disease when patients present less than 7 days of symptom onset. Patients are encouraged to test as soon as they get COVID-19-related symptoms within 1 week and to seek medical advice within 24 h if they develop disturbed smell/taste. The use of rapid antigen tests is important for controlling the COVID-19 pandemic and reducing the burden on molecular diagnostic laboratories.


Assuntos
Antígenos Virais/análise , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Imunoensaio/métodos , Adulto , Teste Sorológico para COVID-19/economia , Reações Falso-Negativas , Feminino , Humanos , Imunoensaio/economia , Masculino , Nasofaringe/virologia , Estudos Prospectivos , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Fatores de Tempo , Carga Viral
8.
Dan Med J ; 68(7)2021 06 14.
Artigo em Inglês | MEDLINE | ID: mdl-34169830

RESUMO

INTRODUCTION: Fast and accurate detection of SARS-CoV-2 is essential in limiting the COVID-19 pandemic. Rapid antigen (AG) tests provide results within minutes; however, their accuracy has been questioned. The study aims to determine the accuracy and cost of the STANDARD Q COVID-19 AG test compared with RT-PCR. METHODS: Individuals 18 years or older with an appointment for a RT-PCR test on 26-31 December 2020 at a public test centre in Copenhagen, Denmark were invited to participate. An oropharyngeal swab was collected for RT-PCR analysis, followed by a nasopharyngeal swab examined by the AG test (SD Biosensor). The diagnostic accuracy of the AG test was calculated with RT-PCR as reference. Costs were evaluated for both tests. RESULTS: A total of 4,811 paired conclusive test results were collected (median age: 45 years, female: 53%). The RT-PCR test revealed 221 (4.6%) positive tests. The overall sensitivity and specificity of the AG test were 69.7% and 99.5%, respectively. Viral cycle threshold values were significantly higher in individuals with false negative AG tests than in individuals who were true positives. The RT-PCR test and AG test costs were 67.0 DKK (10.8 USD) and 35.0 DKK (5.7 USD), respectively, per positive case detected at 100,000 daily tests. CONCLUSIONS: The AG test enables mass testing and provides immediate results, which is important in SARS-CoV-2 screening. The AG test is a good and relevant supplement to RT-PCR testing in public SARS-CoV-2 screenings. FUNDING: This project received no external funding. Copenhagen Medical A/S delivering the rapid AG tests and provided test personnel but were not otherwise involved. TRIAL REGISTRATION: Clinicaltrials.org: NCT04716088.


Assuntos
Teste de Ácido Nucleico para COVID-19/economia , Teste Sorológico para COVID-19/economia , Teste para COVID-19/métodos , COVID-19/diagnóstico , Reação em Cadeia da Polimerase Via Transcriptase Reversa/economia , SARS-CoV-2/isolamento & purificação , Antígenos Virais/análise , COVID-19/epidemiologia , Dinamarca , Feminino , Humanos , Pessoa de Meia-Idade , Pandemias , RNA Viral/genética , DNA Polimerase Dirigida por RNA , SARS-CoV-2/genética , SARS-CoV-2/imunologia , Sensibilidade e Especificidade
9.
Sci Rep ; 11(1): 12330, 2021 06 10.
Artigo em Inglês | MEDLINE | ID: mdl-34112850

RESUMO

SARS-CoV-2 emerged in late 2019 and has since spread around the world, causing a pandemic of the respiratory disease COVID-19. Detecting antibodies against the virus is an essential tool for tracking infections and developing vaccines. Such tests, primarily utilizing the enzyme-linked immunosorbent assay (ELISA) principle, can be either qualitative (reporting positive/negative results) or quantitative (reporting a value representing the quantity of specific antibodies). Quantitation is vital for determining stability or decline of antibody titers in convalescence, efficacy of different vaccination regimens, and detection of asymptomatic infections. Quantitation typically requires two-step ELISA testing, in which samples are first screened in a qualitative assay and positive samples are subsequently analyzed as a dilution series. To overcome the throughput limitations of this approach, we developed a simpler and faster system that is highly automatable and achieves quantitation in a single-dilution screening format with sensitivity and specificity comparable to those of ELISA.


Assuntos
Anticorpos Antivirais/sangue , COVID-19/sangue , SARS-CoV-2/isolamento & purificação , Animais , Anticorpos Antivirais/imunologia , COVID-19/diagnóstico , COVID-19/imunologia , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/métodos , Ensaio de Imunoadsorção Enzimática/economia , Ensaio de Imunoadsorção Enzimática/métodos , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Imunoglobulina M/sangue , Imunoglobulina M/imunologia , Camundongos , SARS-CoV-2/imunologia
10.
Sci Rep ; 11(1): 11837, 2021 06 04.
Artigo em Inglês | MEDLINE | ID: mdl-34088944

RESUMO

Performance of three automated commercial serological IgG-based assays was investigated for assessing SARS-CoV-2 "ever" (past or current) infection in a population-based sample in a high exposure setting. PCR and serological testing was performed on 394 individuals. SARS-CoV-2-IgG seroprevalence was 42.9% (95% CI 38.1-47.8%), 40.6% (95% CI 35.9-45.5%), and 42.4% (95% CI 37.6-47.3%) using the CL-900i, VidasIII, and Elecsys assays, respectively. Between the three assays, overall, positive, and negative percent agreements ranged between 93.2-95.7%, 89.3-92.8%, and 93.8-97.8%, respectively; Cohen's kappa statistic ranged from 0.86 to 0.91; and 35 specimens (8.9%) showed discordant results. Among all individuals, 12.5% (95% CI 9.6-16.1%) had current infection, as assessed by PCR. Of these, only 34.7% (95% CI 22.9-48.7%) were seropositive by at least one assay. A total of 216 individuals (54.8%; 95% CI 49.9-59.7%) had evidence of ever infection using antibody testing and/or PCR during or prior to this study. Of these, only 78.2%, 74.1%, and 77.3% were seropositive in the CL-900i, VidasIII, and Elecsys assays, respectively. All three assays had comparable performance and excellent agreement, but missed at least 20% of individuals with past or current infection. Commercial antibody assays can substantially underestimate ever infection, more so when infection rates are high.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Anticorpos Antivirais/imunologia , COVID-19/epidemiologia , COVID-19/imunologia , Teste Sorológico para COVID-19/economia , Humanos , Imunoglobulina G/imunologia , Incidência , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , Sensibilidade e Especificidade
11.
J Immunol Methods ; 495: 113082, 2021 08.
Artigo em Inglês | MEDLINE | ID: mdl-34051226

RESUMO

The development of new diagnostic assays become a priority for managing COVID-19. To this aim, we presented here an in-house ELISA based on the production of two major recombinant and high-quality antigens from SARS-CoV-2. Full-length N and S-RBD fragment proteins fused to mouse IgG2a-Fc were produced in the CHO cell line. Secreted recombinant proteins were easily purified with standard Protein A chromatography and were used in an in-house ELISA to detect anti-N and anti-RBD IgGs in the plasma of COVID-19 RTPCR-positive patients. High reactivity against recombinant antigens was readily detected in all positive plasma samples, whereas no recognition was observed with control healthy subject's plasmas. Remarkably, unpurified recombinant N protein obtained from cell culture supernatant was also suitable for the monitoring by ELISA of IgG levels in positive patients. This work provides an early prospection for low price but high-quality serological kit development.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/imunologia , Ensaio de Imunoadsorção Enzimática/métodos , Fragmentos Fc das Imunoglobulinas/metabolismo , Imunoglobulina G/metabolismo , Proteínas Recombinantes/metabolismo , SARS-CoV-2/fisiologia , Animais , Anticorpos Antivirais/sangue , Células CHO , Teste Sorológico para COVID-19/economia , Custos e Análise de Custo , Cricetulus , Humanos , Fragmentos Fc das Imunoglobulinas/genética , Imunoglobulina G/genética , Proteínas Recombinantes/genética , Sensibilidade e Especificidade , Glicoproteína da Espícula de Coronavírus/imunologia
12.
Proc Natl Acad Sci U S A ; 118(18)2021 05 04.
Artigo em Inglês | MEDLINE | ID: mdl-33945500

RESUMO

Novel technologies are needed to facilitate large-scale detection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) specific antibodies in human blood samples. Such technologies are essential to support seroprevalence studies and vaccine clinical trials, and to monitor quality and duration of immunity. We developed a microfluidic nanoimmunoassay (NIA) for the detection of anti-SARS-CoV-2 IgG antibodies in 1,024 samples per device. The method achieved a specificity of 100% and a sensitivity of 98% based on the analysis of 289 human serum samples. To eliminate the need for venipuncture, we developed low-cost, ultralow-volume whole blood sampling methods based on two commercial devices and repurposed a blood glucose test strip. The glucose test strip permits the collection, shipment, and analysis of 0.6 µL of whole blood easily obtainable from a simple finger prick. The NIA platform achieves high throughput, high sensitivity, and specificity based on the analysis of 289 human serum samples, and negligible reagent consumption. We furthermore demonstrate the possibility to combine NIA with decentralized and simple approaches to blood sample collection. We expect this technology to be applicable to current and future SARS-CoV-2 related serological studies and to protein biomarker analysis in general.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , COVID-19/sangue , Teste Sorológico para COVID-19/economia , Teste em Amostras de Sangue Seco , Ensaios de Triagem em Larga Escala/economia , Humanos , Imunoensaio/economia , Imunoglobulina G/sangue , Técnicas Analíticas Microfluídicas/economia , Reprodutibilidade dos Testes , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Manejo de Espécimes
13.
PLoS One ; 16(5): e0250886, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33983971

RESUMO

BACKGROUND: SARS-CoV-2 real-time reverse transcriptase polymerase chain reaction (qRT-PCR) is well suited for the diagnosis of clinically ill patients requiring treatment. Application for community testing of symptomatic individuals for disease control purposes however raises challenges. SARS-CoV-2 rapid antigen tests might offer an alternative, but quality evidence on their performance is limited. METHODS: We conducted an evaluation of the test accuracy of the 'BD Veritor System for Rapid Detection of SARS-CoV-2' (VRD) compared to qRT-PCR on combined nose/throat swabs obtained from symptomatic individuals at Municipal Health Service (MHS) COVID-19 test centers in the Netherlands. In part one of the study, with the primary objective to evaluate test sensitivity and specificity, all adults presenting at one MHS test center were eligible for inclusion. In part two, with the objective to evaluate test sensitivity stratified by Ct (cycle threshold)-value and time since symptom onset, adults who had a positive qRT-PCR obtained at a MHS test center were eligible. FINDINGS: In part one (n = 352) SARS-CoV-2 prevalence was 4.8%, overall specificity 100% (95%CI: 98·9%-100%) and sensitivity 94·1% (95%CI: 71·1%-100%). In part two (n = 123) the sensitivity was 78·9% (95%CI: 70·6%-85·7%) overall, 89·4% (95% CI: 79·4%-95·6%) for specimen obtained within seven days after symptom onset and 93% (95% CI: 86%-97.1%) for specimen with a Ct-value below 30. INTERPRETATION: The VRD is a promising diagnostic for COVID-19 testing of symptomatic community-dwelling individuals within seven days after symptom onset in context of disease control. Further research on practical applicability and the optimal position within the testing landscape is needed.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , COVID-19/epidemiologia , Teste Sorológico para COVID-19/economia , Humanos , Vida Independente , Países Baixos/epidemiologia , Estudos Prospectivos , Sensibilidade e Especificidade , Fatores de Tempo
14.
Sci Rep ; 11(1): 7614, 2021 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-33828214

RESUMO

We evaluated the performance of 11 SARS-CoV-2 antibody tests using a reference set of heat-inactivated samples from 278 unexposed persons and 258 COVID-19 patients, some of whom contributed serial samples. The reference set included samples with a variation in SARS-CoV-2 IgG antibody titers, as determined by an in-house immunofluorescence assay (IFA). The five evaluated rapid diagnostic tests had a specificity of 99.0% and a sensitivity that ranged from 56.3 to 81.6% and decreased with low IFA IgG titers. The specificity was > 99% for five out of six platform-based tests, and when assessed using samples collected ≥ 22 days after symptom onset, two assays had a sensitivity of > 96%. These two assays also detected samples with low IFA titers more frequently than the other assays. In conclusion, the evaluated antibody tests showed a heterogeneity in their performances and only a few tests performed well with samples having low IFA IgG titers, an important aspect for diagnostics and epidemiological investigations.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , SARS-CoV-2/isolamento & purificação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Anticorpos Antivirais/sangue , Anticorpos Antivirais/imunologia , COVID-19/sangue , COVID-19/imunologia , Teste Sorológico para COVID-19/economia , Criança , Pré-Escolar , Feminino , Humanos , Imunoglobulina G/sangue , Imunoglobulina G/imunologia , Masculino , Pessoa de Meia-Idade , SARS-CoV-2/imunologia , Sensibilidade e Especificidade , Fatores de Tempo , Adulto Jovem
16.
Biochem Biophys Res Commun ; 553: 165-171, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33773139

RESUMO

The COVID-19 pandemic has caused significant morbidity and mortality. There is an urgent need for serological tests to detect antibodies against SARS-CoV-2, which could be used to assess past infection, evaluate responses to vaccines in development, and determine individuals who may be protected from future infection. Current serological tests developed for SARS-CoV-2 rely on traditional technologies such as enzyme-linked immunosorbent assays (ELISA) and lateral flow assays, which have not scaled to meet the demand of hundreds of millions of antibody tests so far. Herein, we present an alternative method of antibody testing that depends on one protein reagent being added to patient serum/plasma or whole blood with direct, visual readout. Two novel fusion proteins, RBD-2E8 and B6-CH1-RBD, were designed to bind red blood cells (RBCs) via a single-chain variable fragment (scFv), thereby displaying the receptor-binding domain (RBD) of SARS-CoV-2 spike protein on the surface of RBCs. Mixing mammalian-derived RBD-2E8 and B6-CH1-RBD with convalescent COVID-19 patient serum and RBCs led to visible hemagglutination, indicating the presence of antibodies against SARS-CoV-2 RBD. B6-CH1-RBD made in bacteria was not as effective in inducing agglutination, indicating better recognition of RBD epitopes from mammalian cells. Given that our hemagglutination test uses methods routinely used in hospital clinical labs across the world for blood typing, we anticipate the test can be rapidly deployed at minimal cost. We anticipate our hemagglutination assay may find extensive use in low-resource settings for detecting SARS-CoV-2 antibodies.


Assuntos
Anticorpos Antivirais/análise , Anticorpos Antivirais/imunologia , Teste Sorológico para COVID-19/métodos , COVID-19/sangue , COVID-19/imunologia , Testes de Hemaglutinação/métodos , Sistemas Automatizados de Assistência Junto ao Leito , SARS-CoV-2/imunologia , Antígenos Virais/imunologia , COVID-19/diagnóstico , COVID-19/virologia , Teste Sorológico para COVID-19/economia , Eritrócitos/imunologia , Testes de Hemaglutinação/economia , Humanos , Sistemas Automatizados de Assistência Junto ao Leito/economia , Proteínas Recombinantes de Fusão/imunologia , Anticorpos de Cadeia Única/química , Anticorpos de Cadeia Única/imunologia , Glicoproteína da Espícula de Coronavírus/química , Glicoproteína da Espícula de Coronavírus/imunologia , Fatores de Tempo
18.
Am J Trop Med Hyg ; 104(4): 1513-1515, 2021 Feb 25.
Artigo em Inglês | MEDLINE | ID: mdl-33630751

RESUMO

Laboratory diagnosis of the COVID-19 relies on RT-PCR to amplify specific fragments of SARS-CoV-2 genome. However, serological tests are required to determine the immune response elicited after infection. Here, we analyzed convalescent sera collected from positive individuals by RT-PCR to SARS-CoV-2 (n = 78), Zika (n = 20), dengue (n = 20), chikungunya (n = 54), intestinal parasites (n = 11), and HIV (n = 1), from different areas of Ecuador, with an in-house ELISA using a SARS-CoV-2 receptor binding domain recombinant (rRBD) antigen to detect IgG antibodies elicited by SARS-CoV-2 infection. Of the 78 samples positive for SARS-CoV-2 by RT-PCR, 73 showed high absorbance value compared with the cutoff and five were negative. All tested sera from other infections showed no reactivity. Sensitivity, specificity, positive predictive value, and negative predictive value were 93.6%, 100%, 100%, and 95.4%, respectively. This in-house anti-IgG rRBD ELISA offers an economic and simple alternative to determine IgG immune responses after SARS-CoV-2 infection.


Assuntos
Teste Sorológico para COVID-19/métodos , COVID-19/diagnóstico , Ensaio de Imunoadsorção Enzimática/métodos , SARS-CoV-2/imunologia , Glicoproteína da Espícula de Coronavírus/imunologia , Anticorpos Antivirais/sangue , COVID-19/epidemiologia , Teste Sorológico para COVID-19/economia , Equador/epidemiologia , Ensaio de Imunoadsorção Enzimática/economia , Humanos , Imunoglobulina G/sangue , Ligação Proteica , Domínios Proteicos , Proteínas Recombinantes/imunologia , Glicoproteína da Espícula de Coronavírus/química
20.
Epidemiol Prev ; 44(5-6 Suppl 2): 193-199, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33412810

RESUMO

BACKGROUND: facing the SARS-CoV-2 epidemic requires intensive testing on the population to early identify and isolate infected subjects. Although RT-PCR is the most reliable technique to detect ongoing infections, serological tests are frequently proposed as tools in heterogeneous screening strategies. OBJECTIVES: to analyse the performance of a screening strategy proposed by the local government of Tuscany (Central Italy), which first uses qualitative rapid tests for antibody detection, and then RT-PCR tests on the positive subjects. METHODS: a simulation study is conducted to investigate the number of RT-PCR tests required by the screening strategy and the undetected ongoing infections in a pseudo-population of 500,000 subjects, under different prevalence scenarios and assuming a sensitivity of the serological test ranging from 0.50 to 0.80 (specificity 0.98). A compartmental model is used to predict the number of new infections generated by the false negatives two months after the screening, under different values of the infection reproduction number. RESULTS: assuming a sensitivity equal to 0.80 and a prevalence of 0.3%, the screening procedure would require on average 11,167 RT-PCR tests and would produce 300 false negatives, responsible after two months of a number of contagions ranging from 526 to 1,132, under the optimistic scenario of a reproduction number between 0.5 to 1. Resources and false negatives increase with the prevalence. CONCLUSIONS: the analysed screening procedure should be avoided unless the prevalence and the rate of contagion are very low. The cost and effectiveness of the screening strategies should be evaluated in the actual context of the epidemic, accounting for the fact that it may change over time.


Assuntos
Anticorpos Antivirais/sangue , Teste Sorológico para COVID-19 , COVID-19/diagnóstico , Simulação por Computador , Programas de Rastreamento/métodos , Modelos Teóricos , Pandemias , SARS-CoV-2/imunologia , Número Básico de Reprodução , COVID-19/epidemiologia , COVID-19/transmissão , Teste de Ácido Nucleico para COVID-19 , Teste Sorológico para COVID-19/economia , Teste Sorológico para COVID-19/métodos , Análise Custo-Benefício , Reações Falso-Negativas , Reações Falso-Positivas , Humanos , Itália/epidemiologia , Programas de Rastreamento/economia , Método de Monte Carlo , Testes Imediatos/economia , Prevalência , Reação em Cadeia da Polimerase Via Transcriptase Reversa , Sensibilidade e Especificidade