Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 30
Filtrar
1.
Open Vet J ; 10(1): 22-30, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-32426253

RESUMO

Background: Working dogs, such as police dogs and guide dogs, have important roles in the contemporary society by performing specific and demanding jobs. Ocular health and the maintenance of good visual acuity are imperative to strong work performance and thus human safety. Aim: The aim of this study was to assess ophthalmic abnormalities and refractive errors in police and guide dogs in Brazil. Methods: A total of 71 dogs (141 eyes) were evaluated. Ten were guide dogs and 61 were police dogs. The work performance was assessed by a questionnaire to each dog's handler/owner. All the dogs underwent a complete ocular examination, and abnormalities were classified by condition, if they were active or inactive and if they were located within the visual axis. In addition, 62 dogs were evaluated by streak retinoscopy for refractive errors. Results: Ophthalmic abnormalities were detected in 38 (54%) dogs, of which 23 were considered inherited, 25 were considered active, and 10 were located within the visual axis. Incipient cataracts were the most prevalent abnormality. No guide dog had an abnormality within the visual axis. The most common refractive error was myopia with the median and interquartile range of -0.75 ± 0.75 diopters; among these, police dogs had -1.0 ± 0.5 diopters, whereas guide dogs +0.38 ± 0.75 diopters. Police dogs tended to be slightly myopic and guide dogs were emmetropic. Conclusion: Despite finding a considerable number of ophthalmic abnormalities and refractive error, work performance was good with no signs of visual impairment in any dog. Regular ophthalmic examinations are advised for working dogs, and an exclusion of severely affected dogs from breeding programs is recommended.


Assuntos
Catarata/veterinária , Doenças do Cão/diagnóstico , Miopia/veterinária , Cães Trabalhadores , Animais , Brasil , Catarata/diagnóstico , Cães , Feminino , Masculino , Miopia/diagnóstico , Linhagem , Refração Ocular , Retinoscopia/veterinária , Testes Visuais/veterinária
2.
J Am Assoc Lab Anim Sci ; 57(4): 350-356, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29966544

RESUMO

Swine (Sus scrofa) are often the 'gold standard' laboratory animal for ophthalmology research due to the anatomic and physiologic similarities between the porcine and human eye and retina. Despite the importance of this model, few tools for behavioral vision assessment in pigs are available. The aim of this study was to identify and validate a feasible and reproducible behavioral test to assess vision in a pig model of photoreceptor degeneration. In addition, a robust behavioral test will reduce stress and enhance enrichment by allowing animals opportunities for environmental exploration and by reducing the number of invasive experimental procedures. Two distinct behavioral approaches were tested: the obstacle-course test and temperament test. In the obstacle-course test, pigs were challenged (after an initial training period) to navigate a 10-object obstacle course; time and the number of collisions with the objects were recorded. In the temperament test, the time needed for pigs to complete 3 different tasks (human-approach, novel-object, and open-door tests) was recorded. The obstacle-course test revealed significant differences in time and number of collisions between swine with vision impairment and control animals, and the training period proved to be pivotal to avoid bias due to individual animal characteristics. In contrast, the temperament test was not altered by vision impairment but was validated to measure stress and behavioral alterations in laboratory pigs undergoing experimental procedures, thus achieving marked refinement of the study.


Assuntos
Bem-Estar do Animal , Comportamento Animal , Suínos/fisiologia , Testes Visuais/veterinária , Animais , Animais de Laboratório , Humanos , Testes Visuais/métodos
3.
Vet Ophthalmol ; 21(6): 565-576, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29383824

RESUMO

OBJECTIVE: Sudden acquired retinal degeneration syndrome (SARDS) is a leading cause of irreversible blindness in dogs, yet no treatment has been objectively evaluated, or proven to be effective. Consensus of opinion is that SARDS is immune-mediated, although corticosteroid medications may exacerbate associated systemic signs. We examined the effect of sole-agent treatment with mycophenolate mofetil (MMF), a potent immunosuppressive medication unlikely to exacerbate associated systemic signs. ANIMALS STUDIED: Ten client-owned dogs with SARDS prospectively recruited within 6 weeks of vision loss. PROCEDURES: Clinical history, findings of systemic and ophthalmic examinations, blood parameters, visual navigation ability, electroretinography, and optical coherence tomography (OCT) were collected at baseline and at recheck after approximately 6 weeks of treatment with 10 mg/kg q 12 h of oral MMF. RESULTS: Twenty percent of dogs (2/10) experienced side effects (diarrhea, vomiting, lethargy), which resolved with reduction in dose to 8 mg/kg q12 h. No significant changes in systemic signs, physical examination findings, or laboratory test results were detected at the recheck examination. Compared with baseline, visual ability significantly declined at the recheck examination, and the amplitude of a slow-onset negative waveform noted on dark-adapted electroretinography was reduced at the recheck examination. The outer retinal layers were significantly thinner at the recheck examination as measured by OCT. CONCLUSIONS: Mycophenolate mofetil as a sole agent has no measureable positive effect on physical health, vision, or retinal structure following a 6-week trial period. Further studies are needed to evaluate other treatment options for SARDS.


Assuntos
Doenças do Cão/tratamento farmacológico , Imunossupressores/uso terapêutico , Ácido Micofenólico/uso terapêutico , Degeneração Retiniana/veterinária , Animais , Cães , Feminino , Masculino , Projetos Piloto , Estudos Prospectivos , Degeneração Retiniana/tratamento farmacológico , Testes Visuais/veterinária
4.
Vet Ophthalmol ; 21(6): 612-621, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29411487

RESUMO

OBJECTIVE: To describe surgical technique, postoperative complications, and visual outcome in penguins after phacoemulsification lens extraction surgery. ANIMALS STUDIED: Twenty-one penguins (27 eyes) that had phacoemulsification from 2011 to 2015 at Animal Eye Associates. Species included are as follows: 14 southern Rockhopper (18 eyes, 66.6%), 4 Gentoo (4 eyes, 19%), 2 King (3 eyes, 9.5%), and 1 Chinstrap penguin (2 eyes, 4.8%). Eleven of the penguins were females, and 10 were males with average age at the time of surgery being 27.5 years (range of 22-31 years). PROCEDURE: This is a retrospective study of phacoemulsification cataract surgery patients from 2011 to 2015. Visual outcome was evaluated by veterinary ophthalmologists at postoperative recheck examinations and subjectively by penguin keepers using individual bird surveys and paired t tests for statistical analysis. RESULTS: All eyes were functionally visual after surgery and at the time of last follow-up. Based on keeper surveys, 81% (17/21) of penguins showed immediate improvements in overall quality of life and 90% (19/21) of penguins exhibited improvement in mobility and behavior within their exhibit following cataract removal. Of the 14 penguins that received 1:5 intracameral atracurium during surgery, 10 (71.4%) had moderate mydriasis, 1 (7.1%) had minimal mydriasis, and 3 (21.4%) showed no effect to the pupil. Seventy percent of the cases had phacoemulsification times less than 60 seconds/eye; the mean time was 72 seconds. Sixteen eyes (59.3%) underwent anterior capsulotomy only, planned anterior and posterior capsulotomies were performed in 3 eyes (11.1%), and the entire lens capsule was removed due to capsular fibrosis and wrinkling in 8 eyes (29.6%). The most common short-term postoperative complication was temporary mild blepharospasm and/or epiphora, reported in 8 eyes (29.6%) from 7 penguins (33.3%). Long-term complications, 2-6 years postoperatively, included posterior synechiation resulting in dyscoria (10 of 24 eyes, 41.7%) and capsular fibrosis in all penguins with residual lens capsule (19/19, 100%). CONCLUSION: The prognosis for vision and behavioral improvement after phacoemulsification surgery in penguins is good, with low incidence of vision-threatening complications.


Assuntos
Catarata/veterinária , Facoemulsificação/veterinária , Spheniscidae/cirurgia , Animais , Feminino , Masculino , Duração da Cirurgia , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Complicações Pós-Operatórias/veterinária , Estudos Retrospectivos , Transtornos da Visão/veterinária , Testes Visuais/veterinária
5.
Vet Ophthalmol ; 21(6): 586-594, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29380502

RESUMO

OBJECTIVE: In this study, we created the Canine Visual Function Instrument (CVFI) and tested its validity and reliability for assessing the quality of vision of dogs. METHODS: We used Cronbach's alpha to test the strength of the consistency of the questions in the instrument and factor analysis to assess whether the questions achieved unidimensionality in the measurement of dogs' vision quality. RESULTS: Our analysis shows that the CVFI is a valid and reliable tool to seek self-reported observations about dogs' vision quality from owners. Our results also show that the vision quality scale has high empirical validity and therefore can be used to determine whether a dog has normal vision or moderate or serious visual impairments. CONCLUSION: The CVFI might have important practical applications in the field of veterinary ophthalmology in two important ways. First, it can be used to determine whether the treatment of dogs with visual impairment improves vision quality. Second, it can be used as a warning system to alert owners about their dogs' quality of vision.


Assuntos
Doenças do Cão/diagnóstico , Transtornos da Visão/veterinária , Testes Visuais/veterinária , Fatores Etários , Animais , Catarata/diagnóstico , Catarata/veterinária , Cães , Feminino , Humanos , Masculino , Reprodutibilidade dos Testes , Inquéritos e Questionários , Transtornos da Visão/diagnóstico , Visão Ocular/fisiologia
6.
Pesqui. vet. bras ; 37(8): 871-873, Aug. 2017. tab, ilus
Artigo em Inglês | LILACS, VETINDEX | ID: biblio-895491

RESUMO

The aim of this study was to describe the modified Schirmer tear test (mSTT), intraocular pressure (IOP) by rebound tonometry and palpebral fissure length (PFL) in blue-fronted Amazon parrots (Amazona aestiva). Thirty-five healthy adult animals from a conservation breeding center in Brazil were used in this study. Modified Schirmer tear test, rebound tonometry and PFL measurements were performed in both eyes, with birds under physical restraint. Mean mSTT was 6.2±0.1mm/min and mean IOP was 6.4±0.1mmHg, while PFL was 10.1±0.1mm. A moderate correlation was seen between mSTT and PFL for OD (ρ=0.14) and OS (ρ=0.20). The results provide ophthalmic tests reference values for A. aestiva.(AU)


O objetivo deste estudo foi descrever o teste lacrimal de Schirmer modificado (TLSm), a pressão intraocular (PIO) pela tonometria de rebote e o comprimento da fissura palpebral (FP) do papagaio-verdadeiro (Amazona aestiva). Foram avaliados 35 papagaios adultos e saudáveis, provenientes de um Criadouro Conservacionista do Brasil. Após avaliação clínica e laboratorial, as aves foram fisicamente contidas para aferição, em ambos os olhos, do TLSm, da PIO pela tonometria de rebote e do comprimento da FP utilizando-se um paquímetro digital. Valor médio do TLSm foi 6.2±0.1mm/min e da PIO foi 6.4±0.1 mmHg, enquanto a aferição da FP foi 10.1±0.1mm. Uma correlação moderada foi observada entre TLSm e a FP para olho direito (OD) (ρ=0.14) e olho esquerdo (OE) (ρ=0.20). Os resultados podem servir como valores de referência para testes oftálmicos para A. aestiva.(AU)


Assuntos
Animais , Tonometria Ocular/veterinária , Testes Visuais/veterinária , Amazona , Pálpebras/anatomia & histologia , Aparelho Lacrimal/patologia , Animais Selvagens
7.
Comp Med ; 64(4): 300-8, 2014 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25427343

RESUMO

Macaques are the most common animal model for studies in vision research, and due to their high value as research subjects, often continue to participate in studies well into old age. As is true in humans, visual acuity in macaques is susceptible to refractive errors. Here we report a case study in which an aged macaque demonstrated clear impairment in visual acuity according to performance on a demanding behavioral task. Refraction demonstrated bilateral myopia that significantly affected behavioral and visual tasks. Using corrective lenses, we were able to restore visual acuity. After correction of myopia, the macaque's performance on behavioral tasks was comparable to that of a healthy control. We screened 20 other male macaques to assess the incidence of refractive errors and ocular pathologies in a larger population. Hyperopia was the most frequent ametropia but was mild in all cases. A second macaque had mild myopia and astigmatism in one eye. There were no other pathologies observed on ocular examination. We developed a simple behavioral task that visual research laboratories could use to test visual acuity in macaques. The test was reliable and easily learned by the animals in 1 d. This case study stresses the importance of screening macaques involved in visual science for refractive errors and ocular pathologies to ensure the quality of research; we also provide simple methodology for screening visual acuity in these animals.


Assuntos
Animais de Laboratório , Astigmatismo/veterinária , Óculos/veterinária , Macaca mulatta , Doenças dos Macacos/terapia , Miopia/veterinária , Visão Ocular , Fatores Etários , Animais , Astigmatismo/diagnóstico , Astigmatismo/fisiopatologia , Astigmatismo/psicologia , Astigmatismo/terapia , Comportamento Animal , Masculino , Doenças dos Macacos/diagnóstico , Doenças dos Macacos/fisiopatologia , Doenças dos Macacos/psicologia , Miopia/diagnóstico , Miopia/fisiopatologia , Miopia/psicologia , Miopia/terapia , Valor Preditivo dos Testes , Refração Ocular , Reprodutibilidade dos Testes , Testes Visuais/veterinária , Acuidade Visual
8.
Vet Ophthalmol ; 16(5): 319-23, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23173899

RESUMO

OBJECTIVE: To compare the Welch Allyn SureSight™ wavefront autorefractor with retinoscopy in normal dogs. ANIMALS STUDIED: Fifty privately owned dogs (100 eyes) of 20 breeds, free of ocular disease. Mean ± SD age: 5.7 ± 3.25 years (range: 6 months-13 years). PROCEDURES: The refractive error was determined in each eye by two experienced retinoscopists using streak retinoscopy as well as by an autorefractor operated by two different examiners. Measurements were performed before and approximately 30-45 min after cycloplegia was induced by cyclopentolate 0.5% and tropicamide 0.5% ophthalmic solutions. RESULTS: Mean ± SD noncyclopleged retinoscopy net sphere was -0.55 ± 1.14 (range: -3.75 to 3.5) diopters (D). Mean cyclopleged retinoscopy net sphere was -0.52 ± 1.18 (range: -4.25 to 2) D. Mean ± SD noncyclopleged autorefractor spherical equivalent (SE) was -0.42 ± 1.13 D (range: -3.36 to 2.73) D. Mean cyclopleged autorefractor SE was 0.10 ± 1.47 (range: -5.62 to 3.19) D. Noncyclopleged autorefraction results were not significantly different from streak retinoscopy (whether noncyclopleged or cyclopleged, P = 0.80 and P = 0.26, respectively). Cyclopleged autorefraction results were significantly different from noncyclopleged or cyclopleged streak retinoscopy (P < 0.0001 in both states). There was no significant difference between noncyclopleged and cyclopleged streak retinoscopy (P = 0.97). CONCLUSIONS: Noncyclopleged autorefraction shows good agreement with streak retinoscopy in dogs and may be a useful clinical technique. Cycloplegia does not significantly affect streak retinoscopy results in dogs.


Assuntos
Cães/fisiologia , Erros de Refração/veterinária , Refratometria/veterinária , Testes Visuais/veterinária , Animais , Erros de Refração/diagnóstico , Refratometria/instrumentação , Refratometria/métodos , Testes Visuais/instrumentação
9.
Vet Ophthalmol ; 16(5): 324-8, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23121436

RESUMO

OBJECTIVE: The increasing importance of canine retinal dystrophy models means accurate vision testing is needed. This study was performed to evaluate a four-choice vision testing technique for any difference in outcome measures with repeated evaluations of the same dogs. ANIMALS STUDIED: Four 11-month-old RPE65-deficient dogs. PROCEDURES: Vision was evaluated using a previously described four-choice vision testing device. Four evaluations were performed at 2-week intervals. Vision was assessed at six different white light intensities (bright through dim), and each eye was evaluated separately. The ability to select the one of the four exit tunnels that was open at the far end was assessed ('choice of exit') and recorded as correct or incorrect first tunnel choice. 'Time to exit' the device was also recorded. Both outcomes were analyzed for significance using anova. We hypothesized that performance would improve with repeated testing (more correct choices and more rapid time to exit). RESULTS: 'Choice of exit' did not vary significantly between each evaluation (P = 0.12), in contrast 'time to exit' increased significantly (P = 0.012), and showed greater variability in dim light conditions. CONCLUSIONS: We found no evidence to support the hypothesis that either measure of outcome worsened with repeated testing; in fact, the 'time to exit' outcome worsened rather than improved. The 'choice of exit' gave consistent results between trials. These outcome data indicate the importance of including a choice-based assessment of vision in addition to measurement of device transit time.


Assuntos
Doenças do Cão/diagnóstico , Luz , Doenças Retinianas/veterinária , Testes Visuais/veterinária , Animais , Cães , Feminino , Regulação Enzimológica da Expressão Gênica , Masculino , Doenças Retinianas/diagnóstico , cis-trans-Isomerases/genética , cis-trans-Isomerases/metabolismo
10.
Vet Ophthalmol ; 16(5): 329-40, 2013 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-23227950

RESUMO

OBJECTIVE: To develop fast and reliable testing routines for diagnosing retina and optic nerve diseases in canine cataract patients based on chromatic properties of the pupillary light reflex response. PROCEDURES: Seventy-seven canine patients with a history of cataract and decreased vision (43 patients with cataracts and no evidence of retina or optic nerve disease, 21 patients with cataracts and retinal degeneration [RD], 13 patients with cataracts and retinal detachment [RDT]), 11 canine patients with optic neuritis (ON) and 23 healthy dogs were examined using chromatic pupillary light reflex (cPLR) analysis with red and blue light and electroretinography. RESULTS: Electroretinography analysis showed statistically significant deficits in a- and b-wave amplitudes in dogs with cataracts and RD, or cataracts and RDT, when compared to dogs with cataracts without evidence of retinal abnormalities. Evaluation of b-wave amplitudes showed that presence of 78.5-µV (or lower) amplitudes had high sensitivity of 100% (95% CI: 87.2-100%) and high specificity of 96.7% (95% CI: 88.4-100%) in RD and RDT. Evaluation of cPLR responses using red light showed that presence of the pupil end constriction diameter of 5.5 mm (or higher) had moderately high sensitivity of 76.5% (95% CI: 50.1-93.2%) and high specificity of 100% (95% CI: 91.2-100%) in detecting RD and RDT. Optic neuritis patients had absent cPLR responses, regardless of the visual status. CONCLUSIONS AND CLINICAL RELEVANCE: Chromatic evaluation of the pupillary light reflex is a rapid and accurate test for diagnosing retina and optic nerve diseases in canine patients.


Assuntos
Catarata/veterinária , Doenças do Cão/diagnóstico , Nervo Óptico/patologia , Reflexo Pupilar/fisiologia , Retina/patologia , Testes Visuais/veterinária , Animais , Catarata/diagnóstico , Cães , Eletrorretinografia/veterinária , Sensibilidade e Especificidade
12.
Am J Vet Res ; 71(1): 97-102, 2010 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20043788

RESUMO

OBJECTIVE: To develop a quantifiable behavioral test for identification of achromatopsic dogs based on visual performance. ANIMALS: 14 dogs. PROCEDURES: A 3.6-m-long obstacle-avoidance course with 6 obstacle panels was developed from a preliminary 2.4-m-long course. Achromatopsic and visually normal control dogs were run through the course at 4 ambient light intensities (from dim to bright: 0.2, 25, 65, and 646 lux). Completion of 4 runs ranging from dimmest to brightest light intensity constituted 1 complete trial. Each dog underwent 3 trials. Transit times were measured and compared between dog groups and between light intensities by use of a generalized linear model and ANOVA. RESULTS: At the 3 highest light intensities, the achromatopsic dogs needed significantly more time to pass through the obstacle course than the control animals. Compared with the mean transit time at the lowest light intensity, mean transit times were 2.6 times as long at 25 lux, 3.2 times as long at 65 lux, and 5.7 times as long at 646 lux. The achromatopsic dogs had signs of increasing difficulty navigating around the obstacle panels with increasing light intensities; this was not the situation for the control dogs. CONCLUSIONS AND CLINICAL RELEVANCE: A 3.6-m-long obstacle-avoidance course with 6 movable obstacle panels allowed identification of achromatopsic dogs at ambient light intensities >or= 25 lux based on transit times. This test could be helpful in the evaluation of new cone photoreceptor specific treatments.


Assuntos
Comportamento Animal/fisiologia , Defeitos da Visão Cromática/veterinária , Doenças do Cão/diagnóstico , Testes Visuais/veterinária , Animais , Defeitos da Visão Cromática/diagnóstico , Defeitos da Visão Cromática/genética , Doenças do Cão/genética , Cães , Feminino , Predisposição Genética para Doença , Luz , Masculino
13.
Vet Ophthalmol ; 12(5): 292-8, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-19751488

RESUMO

OBJECTIVE: To examine whether the Dominant white mutation (causing a hypopigmented phenotype in chicken) affects the visual ability and gives rise to ocular abnormalities in chickens (Gallus gallus). PROCEDURE: Chickens homozygous for either the Dominant white mutation or the wild-type alleles were tested in a visual contrast behavioral test and subjected to histological and ophthalmologic examination. RESULTS: There were no differences between the genotypes in the visual contrast behavioral test, and there were no abnormal structures among the Dominant white chickens in the ophthalmic examination. The histological sections from the Dominant white chickens did not differ from the wild-type chicken in structure, photoreceptor density, or RPE pigmentation. CONCLUSIONS: The results indicate that the Dominant white mutation in PMEL17 does not seem to affect the visual ability or eye structures in chickens.


Assuntos
Galinhas/genética , Mutagênese Insercional/fisiologia , Doenças das Aves Domésticas/genética , Transtornos da Visão/veterinária , Alelos , Animais , Feminino , Masculino , Retina/anatomia & histologia , Transtornos da Visão/genética , Testes Visuais/veterinária
14.
Invest Ophthalmol Vis Sci ; 49(8): 3568-76, 2008 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-18660425

RESUMO

PURPOSE: The use of canine models of retinal disease in the development of therapeutic strategies for inherited retinal disorders is a growing area of research. To evaluate accurately the success of potential vision-enhancing treatments, reliable methods for objectively assessing visual function in canine models is necessary. METHODS: A simple vision-testing device was constructed that consisted of a junction box with four exit tunnels. Dogs were placed in the junction box and given one vision-based choice for exit. The first-choice tunnel and time to exit were recorded and analyzed. Two canine models of retinal disease with distinct molecular defects, a null mutation in the gene encoding the alpha subunit of rod cyclic GMP phosphodiesterase (PDE6A), and a null mutation in the gene encoding a retinal pigment epithelium-specific protein (RPE65) were tested and compared to those in unaffected dogs. RESULTS: With the use of bright light versus dim red light, the test differentiated between unaffected dogs and dogs affected with either mutation with a high degree of certainty. The white-light intensity series showed a significantly different performance between the unaffected and affected dogs. A significant difference in performance was detected between the dogs with each mutation. CONCLUSIONS: The results indicate that this novel canine vision-testing method is an accurate and sensitive means of distinguishing between unaffected dogs and dogs affected with two different forms of inherited retinal disease and should be useful as a means of assessing response to therapy in future studies.


Assuntos
Modelos Animais de Doenças , Doenças do Cão/diagnóstico , Retina/patologia , Degeneração Retiniana/veterinária , Testes Visuais/veterinária , Animais , Comportamento Animal/fisiologia , Proteínas de Transporte/genética , Comportamento de Escolha/fisiologia , Nucleotídeo Cíclico Fosfodiesterase do Tipo 6/genética , Doenças do Cão/genética , Cães , Eletrorretinografia , Proteínas do Olho/genética , Reações Falso-Positivas , Feminino , Luz , Masculino , Mutação , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Degeneração Retiniana/diagnóstico , Degeneração Retiniana/genética , Sensibilidade e Especificidade , Acuidade Visual/fisiologia
15.
Nat Protoc ; 1(4): 1898-905, 2006.
Artigo em Inglês | MEDLINE | ID: mdl-17487174

RESUMO

The dependence of visual orienting ability in hamsters on the axonal projections from retina to midbrain tectum provides experimenters with a good model for assessing the functional regeneration of this central nervous system axonal pathway. For reliable testing of this behavior, male animals at least 10-12 weeks old are prepared by regular pretesting, with all procedures carried out during the less active portion of the daily activity cycle. Using a sunflower seed attached to a small black ball held at the end of a stiff wire, and avoiding whisker contact, turning movements toward visual stimuli are video recorded from above. Because at the eye level, the nasal-most 30 degrees of the visual field can be seen by both the eyes, this part of the field is avoided in assessments of a single side. Daily sessions consist of ten presentations per side. Measures are frequency of responding and detailed turning trajectories. Complete assessment of the functional return of behavior in this testing paradigm takes 3-6 months to complete.


Assuntos
Comportamento Apetitivo/fisiologia , Testes Neuropsicológicos , Testes Visuais/veterinária , Visão Ocular/fisiologia , Percepção Visual/fisiologia , Animais , Cricetinae , Masculino , Mesocricetus
16.
Vision Res ; 45(11): 1439-46, 2005 May.
Artigo em Inglês | MEDLINE | ID: mdl-15743613

RESUMO

In both scotopic and photopic conditions, the rotation of a grating was found to elicit head movements in mice. The highest spatial frequency eliciting this optomotor response provided an estimate of visual acuity. In male C57BL/6J mice, visual acuity increased from 0.26cpd in scotopic conditions to 0.52cpd in photopic conditions whereas it was 0.52 cpd in both sets of conditions in 129/SvPas mice. No optomotor response was detected in albino CD1 mice and rd1 retinal degeneration mice although light sensitivity in CD1 mice was attested by photophobia and normal electroretinograms. This rapid and cheap method could provide a powerful test of visual performance in genetically modified and pharmacologically treated mice.


Assuntos
Movimentos Sacádicos/fisiologia , Testes Visuais/veterinária , Acuidade Visual/fisiologia , Animais , Adaptação à Escuridão/fisiologia , Eletrorretinografia , Feminino , Cabeça , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Movimento , Estimulação Luminosa , Células Fotorreceptoras de Vertebrados/fisiologia , Psicofísica , Testes Visuais/métodos
17.
Primates ; 44(2): 171-6, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12687482

RESUMO

Although color vision deficiency is very rare among Old World monkeys and apes, one male chimpanzee (Lucky) was identified as protanomalous by genetic and physiological analyses. This study assessed behavioral phenotypes of Lucky and four chimpanzees with normal color vision by discrimination task using the modified Ishihara pseudo-isochromatic plates. Lucky could not discriminate the stimuli that the other chimpanzees could. This is the first behavioral evidence of color vision deficiency in chimpanzees.


Assuntos
Defeitos da Visão Cromática/fisiopatologia , Discriminação Psicológica/fisiologia , Pan troglodytes/fisiologia , Testes Visuais/veterinária , Animais , Masculino
18.
Invest Ophthalmol Vis Sci ; 44(4): 1663-72, 2003 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-12657607

RESUMO

PURPOSE: To assess the efficacy of AAV-mediated gene therapy to restore vision in a large number of RPE65(-/-) dogs and to determine whether systemic and local side effects are caused by the treatment. METHODS: Normal RPE65 dog cDNA was subcloned into an rAAV vector under control of a cytomegalovirus promoter, and an AAV.GFP control vector was also produced with the titers 2 x 10(12) particles/mL and 2 x 10(10) transducing U/mL, respectively. RPE65(-/-) dogs, aged 4 to 30 months were treated with subretinal injections of the AAV.RPE65 and control vectors, respectively, in each eye, and three 24- to 30-month-old normal control dogs with the latter. Baseline and postoperative systemic and ophthalmic examinations, blood screenings, vision testing, and electroretinography (ERG) were performed. Two RPE65(-/-) dogs were killed at 3 and 6 months after treatment for morphologic examination of the retinas. RESULTS: RPE65(-/-) dogs were practically blind from birth with nonrecordable or low-amplitude ERGs. Construct injections or sham surgeries were performed in 28 eyes; 11 were injected subretinally with the AAV.RPE65 construct. ERGs at 3 months after surgery showed that in the latter eyes, dark-adapted b-wave amplitudes recovered to an average of 28% of normal, and light adapted b-wave amplitudes to 32% of normal. ERG amplitudes were not reduced during a 6- to 9-month follow-up. No systemic side effects were observed, but uveitis developed in nine AAV.RPE65-treated eyes. No uveitis was observed in the eyes treated with the control vector. Immunocytochemistry showed expression of RPE65 in the retinal pigment epithelium (RPE) of AAV.RPE65-treated eyes. Fluorescence microscopy showed expression of green fluorescent protein (GFP) in the RPE and, to a lesser extent, in the neural retinas of AAV.GFP-treated eyes. Ultrastructurally, a reversal of RPE lipid droplet accumulation was observed at the AAV.RPE65 transgene injection site, but not at the site of injection of the control vector. CONCLUSIONS: In 10 of 11 treated RPE65(-/-) eyes, gene transfer resulted in development of vision, both subjectively apparent by loss of nystagmus, and objectively recorded by ERG. Structurally, there was reversal of lipid droplet accumulation in the RPE. Uveitis developed in 75% of the transgene-treated eyes, a complication possibly due to an immunopathogenic response to the RPE65 molecule.


Assuntos
Doenças do Cão/terapia , Proteínas do Olho/genética , Terapia Genética/métodos , Mutação , Cegueira Noturna/veterinária , Proteínas/genética , Retina/fisiopatologia , Degeneração Retiniana/veterinária , Animais , Adaptação à Escuridão , Dependovirus/genética , Doenças do Cão/genética , Doenças do Cão/fisiopatologia , Cães , Eletrorretinografia/veterinária , Feminino , Técnicas de Transferência de Genes/veterinária , Terapia Genética/efeitos adversos , Vetores Genéticos , Proteínas de Fluorescência Verde , Indicadores e Reagentes/metabolismo , Metabolismo dos Lipídeos , Proteínas Luminescentes/metabolismo , Masculino , Cegueira Noturna/genética , Cegueira Noturna/fisiopatologia , Cegueira Noturna/terapia , Epitélio Pigmentado Ocular/metabolismo , Epitélio Pigmentado Ocular/ultraestrutura , Retina/metabolismo , Retina/patologia , Degeneração Retiniana/genética , Degeneração Retiniana/fisiopatologia , Degeneração Retiniana/terapia , Uveíte/etiologia , Testes Visuais/veterinária
19.
Optometry ; 72(7): 421-5, 2001 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-11486936

RESUMO

BACKGROUND: Though plano bandage contact lenses used for therapeutic purposes are not uncommon for dogs, no literature regarding contact lenses to correct aphakic canines currently exists. CASE REPORT: Oliver, a 7-year-old terrier mix, was aphakic in his left eye and essentially blind in his right eye as the result of a large retinal detachment. Surgical complications and endothelium damage contraindicated an intraocular lens implant in his left eye. While co-managed with his veterinary ophthalmologist, Oliver was prescribed an aphakic hydrogel contact lens to improve his monocular vision. CONCLUSION: Oliver was successful (by clinical criteria) with his contact lens. Although it is difficult to quantify his vision without a visual evoked potential, Oliver appeared more attentive and confident with the contact lens. This case report demonstrates a successful canine aphakic contact lens fit through the efforts of his owners, co-managing veterinary ophthalmologist, and optometrist.


Assuntos
Afacia Pós-Catarata/veterinária , Lentes de Contato/veterinária , Doenças do Cão/terapia , Hidrogel de Polietilenoglicol-Dimetacrilato , Ajuste de Prótese/veterinária , Animais , Afacia Pós-Catarata/terapia , Cães , Masculino , Testes Visuais/veterinária , Acuidade Visual
20.
Vet Ophthalmol ; 4(4): 243-53, 2001 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-11906659

RESUMO

Functional magnetic resonance imaging (fMRI) is a recent advance in neuroimaging that provides a picture of brain activity with excellent spatial resolution. Current methods used to evaluate canine vision are poorly standardized and vulnerable to bias. Functional MRI may represent a valuable method of testing vision in dogs if the impacts of anesthesia on fMRI are understood. Six dogs were scanned during visual stimulation, each under three different anesthetic protocols (isoflurane, propofol, fentanyl/midazolam) to address the questions: (1) Can visually evoked fMR signals be reliably recorded in anesthetized dogs? and (2) Which anesthetic agent permits the least suppression of visually induced fMR signal in dogs? This study confirms that visual stimuli reliably elicit neural activity and fMR signal change in anesthetized dogs. No significant differences in images acquired under the three anesthetics were found, and there was no significant relationship between anesthetic dose and brain activity, within the range of doses used in this study. Images obtained during isoflurane anesthesia were more consistent between dogs than those obtained with the other two agents. This reduced variation may reflect the fact that inhalant anesthesia is more easily controlled than intravenous anesthesia under conditions associated with high field fMRI.


Assuntos
Anestesia/veterinária , Doenças do Cão/diagnóstico , Cães/fisiologia , Oftalmopatias/veterinária , Imageamento por Ressonância Magnética/veterinária , Testes Visuais/veterinária , Córtex Visual/fisiologia , Anestésicos Inalatórios/uso terapêutico , Anestésicos Intravenosos/uso terapêutico , Animais , Oftalmopatias/diagnóstico , Feminino , Fentanila/administração & dosagem , Fentanila/uso terapêutico , Isoflurano/administração & dosagem , Isoflurano/uso terapêutico , Imageamento por Ressonância Magnética/normas , Masculino , Midazolam/administração & dosagem , Midazolam/uso terapêutico , Valor Preditivo dos Testes , Propofol/administração & dosagem , Propofol/uso terapêutico , Testes Visuais/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA