Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 539
Filtrar
1.
Spectrochim Acta A Mol Biomol Spectrosc ; 319: 124521, 2024 Oct 15.
Artigo em Inglês | MEDLINE | ID: mdl-38830329

RESUMO

The USFDA recently approved mirabegron, a novel once-daily ß-3 adrenoceptor agonist for oral administration, as a transformative treatment for overactive bladder. Despite the existence of numerous analytical methods for the assay and bioanalysis of mirabegron, it's perplexing that none have explored the domain of microwave-assisted sensitive spectrofluorimetric method for mirabegron estimation, even after extensive literature review. Adding to the enigma is the insistence of current analytical methods on using expensive and harmful organic solvents, posing a threat to marine life and the broader environment. Recently, the white analytical chemistry approach has been introduced to develop analytical methods that are cost-effective, environmentally friendly, and user-friendly. Consequently, a white analytical chemistry-based, sensitive, and eco-friendly spectrofluorimetric estimation of mirabegron has been initiated, using 4-Chloro-7-nitrobenzofurazan as a fluorescent biosensing probe. The development of this robust method involved a series of experiments designed to minimize solvent and time wastage. Through a combination of fractional factorial and Box-Behnken designs, researchers identified the critical variables and optimized the method to perfection. This method was validated according to the stringent ICH Q2 (R2) and USFDA guidelines, ensuring its reliability and accuracy. Once approved, this sensitive spectrofluorimetric method was tested, accurately estimating mirabegron levels in commercial formulations and rat plasma samples. To further enrich the study, a comprehensive evaluation of existing analytical methods was conducted alongside the proposed spectrofluorimetric method, using advanced tools like the AGREE calculator, GAPI software, and RGB model to assess their eco-friendliness and effectiveness in mirabegron estimation.


Assuntos
Acetanilidas , Corantes Fluorescentes , Micro-Ondas , Espectrometria de Fluorescência , Tiazóis , Tiazóis/química , Tiazóis/sangue , Tiazóis/análise , Acetanilidas/análise , Acetanilidas/sangue , Acetanilidas/química , Animais , Corantes Fluorescentes/química , Espectrometria de Fluorescência/métodos , Técnicas Biossensoriais/métodos , Química Verde/métodos , Reprodutibilidade dos Testes , Ratos , Limite de Detecção , Masculino
2.
Spectrochim Acta A Mol Biomol Spectrosc ; 318: 124515, 2024 Oct 05.
Artigo em Inglês | MEDLINE | ID: mdl-38810435

RESUMO

Mirabegron (MRB) is a ß3-adrenoceptor agonist used for managing overactive bladder syndrome. A cost-effective, environmentally friendly, and highly sensitive spectrofluorimetric method was suggested to serve the purpose of quantifying MRB in its pure state, pharmaceutical tablets, spiked human plasma and urine, and testing content uniformity. In the present study, ninhydrin and phenylacetaldehyde react with the amino group moiety of MRB in Teorell-Stenhagen buffer (pH 7.5) to generate a strongly fluorescent diaryl pyrrolone compound that emits fluorescence at a wavelength of 477 nm upon excitation at 385 nm. The obtained calibration curve showed a linear relationship with a high correlation coefficient (r = 0.9997) in the concentration range of 0.25 to 5.0 µg mL-1. Limits of detection (LOD) and quantitation (LOQ) were 0.082 and 0.248 µg mL-1 respectively. The procedure was verified in accordance with the ICH guidelines. The suggested approach could be utilized for the selective analysis of MRB in its pharmaceuticals, either containing a single drug or co-formulated with solifenacin succinate. The greenness of the suggested method was confirmed using different green analytical metrics.


Assuntos
Acetanilidas , Limite de Detecção , Ninidrina , Espectrometria de Fluorescência , Tiazóis , Humanos , Ninidrina/química , Espectrometria de Fluorescência/métodos , Acetanilidas/urina , Acetanilidas/sangue , Acetanilidas/química , Tiazóis/química , Tiazóis/urina , Tiazóis/sangue , Pirróis/química , Corantes Fluorescentes/química , Corantes Fluorescentes/síntese química , Comprimidos , Acetaldeído/análogos & derivados
3.
Spectrochim Acta A Mol Biomol Spectrosc ; 316: 124372, 2024 Aug 05.
Artigo em Inglês | MEDLINE | ID: mdl-38703408

RESUMO

Here, a novel fluorescence strategy was established for the detection of mirabegron (MBG) sensitively on the basis of hantzsch dihydropyridine synthesis. The developed method adopts turn-on fluorescence of MBG for the first time, permitting its selective determination in spiked human plasma at 486 nm after excitation at 410 nm. The developed method exhibited a good linear range from 0.5 µgmL-1 to 2.0 µgmL-1 with detection and quantification limits of 0.05 and 0.2 (µgmL-1), respectively. The profitable applicability of the developed method in spiked human plasma samples was demonstrated, achieving limit of detection below the previously levels reported by spectroscopic methods, allowing application of the developed method for selective determination of MBG in its tablets and spiked human plasma samples with good recovery.


Assuntos
Acetanilidas , Limite de Detecção , Espectrometria de Fluorescência , Tiazóis , Humanos , Tiazóis/sangue , Tiazóis/química , Acetanilidas/sangue , Acetanilidas/química , Espectrometria de Fluorescência/métodos , Reprodutibilidade dos Testes
4.
Clin Pharmacol Drug Dev ; 13(7): 748-754, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38573189

RESUMO

Nitazoxanide (NTZ) is an effective antiparasitic drug with potent antiviral and antimicrobial activity. This randomized, open-label, 2-sequence, 2-period crossover trial was designed to evaluate the bioequivalence (BE) of the NTZ dry suspension in healthy subjects and investigated the effect of food intake on the pharmacokinetic (PK) properties of tizoxanide (an active metabolite of NTZ, TIZ). Sixty healthy Chinese subjects were enrolled and received a single dose of 500 mg/25 mL of preparations on days 1 and 4 under overnight fasting or fed conditions, respectively. The plasma concentration of TIZ was determined using high-performance liquid chromatography/tandem mass spectrometry. PK parameters were calculated using WinNonlin 8.2 and BE was evaluated using SAS 9.4. The 90% confidence intervals for the geometric mean ratio (test/reference) of maximum concentration (Cmax), the area under the curve from time 0 to the time of the last quantifiable concentration (AUC0-t), and the area under the curve from time 0 to extrapolation to infinity (AUC0-∞) were all within the equivalent interval of 80%-125%, compliant with BE requirements. In comparison with fasting, on taking the reference and test preparations of the NTZ dry suspension after a meal, the AUC0-t increased by 48.9% and 47.3%, respectively, the AUC0-∞ increased by 48.4% and 48.3%, respectively, and the post-meal Tmax was prolonged by 1.8-2 hours. Our results demonstrate that the test and reference preparations were bioequivalent. High-fat meals significantly improve the degree of drug absorption and delay the rate of drug absorption.


Assuntos
Área Sob a Curva , Estudos Cross-Over , Interações Alimento-Droga , Voluntários Saudáveis , Nitrocompostos , Suspensões , Equivalência Terapêutica , Tiazóis , Humanos , Masculino , Adulto , Adulto Jovem , Administração Oral , Tiazóis/farmacocinética , Tiazóis/administração & dosagem , Tiazóis/sangue , Feminino , Nitrocompostos/farmacocinética , Nitrocompostos/administração & dosagem , Jejum , Antiparasitários/farmacocinética , Antiparasitários/administração & dosagem , Antiparasitários/sangue , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão
5.
Scand J Clin Lab Invest ; 81(6): 461-468, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34278897

RESUMO

In this study, we evaluated the in vitro stability of direct oral anticoagulants (DOACs) in blood samples of 57 patients under different storage conditions using functional coagulation assays. We determined the analyte concentrations (1) immediately after blood collection (baseline); (2) after storage of citrated whole blood (agitated) at room temperature and citrated plasma at room temperature and at 4 °C for 4, 8, and 24 h, respectively; and (3) after storage of citrated plasma at -20 °C for 30, 60, and 90 days. According to the concept of acceptable change limits (ACL), analytes were considered stable if the mean relative analyte recovery at a given time was >78%. The mean baseline values (range) of dabigatran, rivaroxaban, apixaban, and edoxaban were 115 ng/mL (62-217), 129 ng/mL (31-215), 156 ng/mL (49-362), and 101 ng/mL (33-283), respectively. After applying the analyte stability limit, all four DOACs were stable for 24 h at room temperature and at 4 °C. The mean recovery after 24 h was 102-111% for dabigatran, 88-97% for rivaroxaban, 95-98% for apixaban, and 90-96% for edoxaban. When plasma samples were stored at -20 °C, the mean percentage deviation after 90 days for all four DOACs was ≤10%, even after three freeze-thaw cycles. Thus, for the correct determination of DOAC plasma concentrations, blood samples do not have to be analyzed immediately and can be stored at room temperature for up to 24 h before analysis. In clinical practice, blood sample transport and storage for DOAC measurements appear to be unproblematic.


Assuntos
Anticoagulantes/administração & dosagem , Anticoagulantes/sangue , Coleta de Amostras Sanguíneas , Preservação Biológica , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Dabigatrana/sangue , Humanos , Pessoa de Meia-Idade , Pirazóis/sangue , Piridinas/sangue , Piridonas/sangue , Rivaroxabana/sangue , Tiazóis/sangue
6.
J Am Coll Cardiol ; 77(9): 1197-1207, 2021 03 09.
Artigo em Inglês | MEDLINE | ID: mdl-33663737

RESUMO

BACKGROUND: In the ENGAGE AF-TIMI 48 (Effective Anticoagulation with Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis In Myocardial Infarction 48) trial, the lower dose edoxaban regimen (LDER) and the higher dose edoxaban regimen (HDER) were noninferior to well-managed warfarin for stroke prevention in atrial fibrillation. OBJECTIVES: The objective of the present analysis of the ENGAGE AF TIMI-48 trial was to comprehensively compare the net clinical outcome (NCO) of LDER (30 mg once daily, dose reduced to 15 mg in selective patients) versus HDER (60 mg once daily, dose reduced to 30 mg in selective patients). METHODS: This study performed a pre-specified analysis of the ENGAGE AF-TIMI 48 trial, comparing patients on LDER versus HDER. RESULTS: The pre-defined primary NCO (stroke/systemic embolism [SEE], major bleeding, death) was less frequent with LDER (7.26% vs. 8.01%; hazard ratio: 0.90; 95% confidence interval: 0.84 to 0.98; p = 0.014). The secondary (disabling stroke, life-threatening bleeding, or all-cause mortality) and tertiary pre-defined NCOs (stroke, SEE, life-threatening bleeding, or all-cause mortality) were similar between the 2 dosing regimens. Patients randomized to LDER versus HDER had a significantly higher risk of stroke/SEE (2.04% vs. 1.56%; hazard ratio: 1.31; 95% confidence interval: 1.12 to 1.52; p < 0.001). Conversely, major bleeding, intracranial hemorrhage, major gastrointestinal bleeding, and life-threatening bleeding occurred significantly less frequently with LDER compared with those of HDER. These findings were supported by multiple pharmacokinetic findings. CONCLUSIONS: In the ENGAGE AF-TIMI 48 trial, the primary NCO was reduced with LDER versus HDER, whereas the secondary and tertiary NCOs were similar between the 2 dosing regimens. These results may aid physicians in evidence-based individualization of edoxaban dosing. However, the approved HDER remains the standard therapy among the available edoxaban dosing regimens for stroke prevention in atrial fibrillation. (Effective Anticoagulation with Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis In Myocardial Infarction 48 [ENGAGE AF-TIMI 48]; NCT00781391).


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Inibidores do Fator Xa/administração & dosagem , Piridinas/administração & dosagem , Tiazóis/administração & dosagem , Idoso , Fibrilação Atrial/sangue , Relação Dose-Resposta a Droga , Método Duplo-Cego , Inibidores do Fator Xa/sangue , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Piridinas/sangue , Tiazóis/sangue
7.
Artigo em Inglês | MEDLINE | ID: mdl-33387858

RESUMO

Alpelisib, a novel phosphatidylinositol 3-kinase inhibitor, is an oral anticancer agent approved for the treatment of advanced or metastatic breast cancer. In this study, a sensitive bioanalytical method using high-performance liquid chromatography combined with a fluorescence detector (HPLC-FLD) was developed for the determination of alpelisib in rat plasma. This newly developed method was validated in terms of linearity (1-1,000 ng/mL), precision, accuracy, recovery, matrix effect, and stability according to the US Food and Drug Administration guideline and these parameters were within the acceptable limits. Alpelisib tended to be stable in plasma, urine, simulated intestinal fluid, and buffer with pH > 4.0 for 24 h, but in the pH 1.2 buffer and simulated gastric fluid for up to 4 h only. A study involving intravenous administration of alpelisib in rats showed that the dose-normalized area under the plasma concentration versus time curve (AUC) of alpelisib changed significantly as the dose increased from 1 to 10 mg/kg. Similarly, an oral rat study indicated that the dose-normalized AUC and the fraction of dose that remained in the gastrointestinal (GI) tract changed significantly as the dose increased from 0.5 to 10 mg/kg. These nonlinear (dose-dependent) pharmacokinetics of intravenous and oral alpelisib could be attributed to the saturation of ubiquitous metabolism among most tissues and/or GI absorption processes. To the best of our knowledge, this is the first study to investigate the in vivo nonlinear pharmacokinetics of alpelisib and its possible mechanisms, together with a new HPLC-FLD method to determine alpelisib in biological matrices.


Assuntos
Cromatografia Líquida de Alta Pressão/métodos , Tiazóis/sangue , Tiazóis/farmacocinética , Animais , Limite de Detecção , Masculino , Dinâmica não Linear , Inibidores de Proteínas Quinases/sangue , Inibidores de Proteínas Quinases/química , Inibidores de Proteínas Quinases/farmacocinética , Ratos , Ratos Sprague-Dawley , Reprodutibilidade dos Testes , Tiazóis/química
8.
J Clin Pharmacol ; 61(4): 522-530, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33027547

RESUMO

The capability of viscoelastic measurement parameters to screen anticoagulation activity of edoxaban in relation to its plasma concentrations was evaluated in 15 healthy male volunteers. Blood samples were drawn before the oral administration of edoxaban 60 mg and 2, 4, 6, 8, and 24 hours after administration. At each time, standard coagulation tests were performed, blood viscoelastic properties were measured with a thromboelastometry device ROTEM delta analyzer (Instrumentation Laboratory, Werfen, Barcelona, Spain), and edoxaban plasma concentrations were measured. Our primary interest was the possible correlation between edoxaban plasma concentrations and values for ROTEM ExTEM, and FibTEM. We also studied the correlation of edoxaban plasma concentrations with the results of standard coagulation tests. We saw the effect of a single dose of edoxaban most clearly in clotting time (CT) of ROTEM ExTEM and FibTEM. Changes in these parameters correlated significantly with edoxaban plasma concentrations up to 6 hours from the ingestion of the drug. Activated partial thromboplastin time, prothrombin time, and anti-factor Xa were also affected. Peak changes were observed 2 and 4 hours after administration of edoxaban. The changes were mostly reversed after 8 hours. In conclusion, ROTEM CT correlates significantly with edoxaban plasma concentrations and can be used to estimate the effect of edoxaban. ROTEM should be considered as part of the assessment of coagulation, with the big advantage of being readily available on site.


Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Viscosidade Sanguínea/efeitos dos fármacos , Piridinas/sangue , Tiazóis/sangue , Adolescente , Adulto , Testes de Coagulação Sanguínea , Voluntários Saudáveis , Humanos , Estudos Longitudinais , Masculino , Adulto Jovem
9.
Br J Clin Pharmacol ; 87(4): 2078-2088, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33085781

RESUMO

BACKGROUND: Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has been declared a global pandemic and urgent treatment and prevention strategies are needed. Nitazoxanide, an anthelmintic drug, has been shown to exhibit in vitro activity against SARS-CoV-2. The present study used physiologically based pharmacokinetic (PBPK) modelling to inform optimal doses of nitazoxanide capable of maintaining plasma and lung tizoxanide exposures above the reported SARS-CoV-2 EC90 . METHODS: A whole-body PBPK model was validated against available pharmacokinetic data for healthy individuals receiving single and multiple doses between 500 and 4000 mg with and without food. The validated model was used to predict doses expected to maintain tizoxanide plasma and lung concentrations above the EC90 in >90% of the simulated population. PopDes was used to estimate an optimal sparse sampling strategy for future clinical trials. RESULTS: The PBPK model was successfully validated against the reported human pharmacokinetics. The model predicted optimal doses of 1200 mg QID, 1600 mg TID and 2900 mg BID in the fasted state and 700 mg QID, 900 mg TID and 1400 mg BID when given with food. For BID regimens an optimal sparse sampling strategy of 0.25, 1, 3 and 12 hours post dose was estimated. CONCLUSION: The PBPK model predicted tizoxanide concentrations within doses of nitazoxanide already given to humans previously. The reported dosing strategies provide a rational basis for design of clinical trials with nitazoxanide for the treatment or prevention of SARS-CoV-2 infection. A concordant higher dose of nitazoxanide is now planned for investigation in the seamless phase I/IIa AGILE trial.


Assuntos
Antivirais/administração & dosagem , Tratamento Farmacológico da COVID-19 , COVID-19/prevenção & controle , Reposicionamento de Medicamentos , Modelos Biológicos , Nitrocompostos/administração & dosagem , Tiazóis/administração & dosagem , Adulto , Antivirais/sangue , Antivirais/farmacocinética , COVID-19/sangue , Simulação por Computador , Cálculos da Dosagem de Medicamento , Feminino , Humanos , Pulmão/metabolismo , Masculino , Pessoa de Meia-Idade , Nitrocompostos/sangue , Nitrocompostos/farmacocinética , Reprodutibilidade dos Testes , Tiazóis/sangue , Tiazóis/farmacocinética , Distribuição Tecidual , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-32947189

RESUMO

As an anticoagulant, Edoxaban (EDX) is a high risk drug that may cause a life-threatening bleeding. Also, it is prescribed as a chronic therapy for atrial fibrillation and venous thromboembolism patients. They are special population that needs appropriate care and optimum dosing of EDX. Hence, its monitoring in the patient plasma is fundamental, especially in emergency and special circumstances. However, such patient mostly receives many drugs of different pharmacological classes, side by side with EDX. This study represents the first attempt to quantify EDX in plasma without interference of the plasma matrix or concomitant medications. An accurate RP-HPLC-DAD method was developed for this purpose. It succeeded to monitor EDX level, selectively, without interference of plasma matrix or 16 of its frequently co-administered drugs. All drugs were extracted from plasma samples by protein precipitation followed by evaporation and concentration. EDX was well resolved from the co-administered drugs on C8 column using linear gradient elution of methanol and phosphate buffer (pH 4), at a flow rate of 1 mL/min. EDX appeared at retention time 9.6 min and was quantified at its λmax (290 nm). It exhibited a linear response over the concentration range of 0.15-2.2 µg/mL plasma which covers the reported therapeutic concentration. The suggested method fulfilled the US FDA guidelines for bioanalytical method validation. The developed method is fully discussed in comparison with the reported techniques. An in vivo study was performed to ensure applicability of the method on real plasma samples without interference from plasma matrix, co-administered drugs or the expected metabolites. It presented a unique selectivity of the method that guarantees accurate laboratory monitoring of EDX in plasma in almost all combined treatments including such novel oral anticoagulant drug.


Assuntos
Anticoagulantes/sangue , Cromatografia Líquida de Alta Pressão/métodos , Piridinas/sangue , Tiazóis/sangue , Administração Oral , Animais , Anticoagulantes/administração & dosagem , Anticoagulantes/isolamento & purificação , Modelos Lineares , Masculino , Piridinas/administração & dosagem , Piridinas/isolamento & purificação , Ratos , Ratos Wistar , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tiazóis/administração & dosagem , Tiazóis/isolamento & purificação
11.
J Chromatogr Sci ; 58(9): 796-803, 2020 Sep 29.
Artigo em Inglês | MEDLINE | ID: mdl-32839813

RESUMO

(E/Z)-(4-(3-(2-((4-chlorophenyl)amino)-4-(dimethylamino)thiazol-5-yl)-2-(ethoxy carbonyl)-3-oxoprop-1-en-1-yl)phenyl) boronic acid, a newly developed molecule having anticancer activity serves as a potential candidate for the further drug development process. In this study, to ascertain the anticancer potential of the molecule, we screened it against different cell lines and compared the activity against the standard drug doxorubicin. The molecule showed promising activity at a low concentration against almost all cell lines used in the study. Apart from that, the molecule was characterized for its pKa and a precise reverse phase high-performance liquid chromatography bioanalytical method has been developed. The method was validated according to the United States of Food and Drug Administration bioanalytical guideline and was found to produce linear response over the calibration range of 0.8-25 µg/mL. Inter- and intra-day accuracy were found to be in the range of 93.44-99.74%, whereas precision [% coefficient of variation (CV)] for inter- and intra-day was ranged between 1.63 and 5.79%, and 0.87 and 6.96%, respectively. The bioanalytical stability testing was carried out in different conditions including 8 h benchtop, 12 h autosampler and three freeze-thaw cycles. The analyte was stable in all the tested stability conditions. Finally, an in vitro metabolite identification study was conducted using quadrupole-time of flight-mass spectrometer, and two metabolites have been identified.


Assuntos
Antineoplásicos/sangue , Ácidos Borônicos/sangue , Tiazóis/sangue , Antineoplásicos/química , Antineoplásicos/metabolismo , Antineoplásicos/farmacologia , Ácidos Borônicos/química , Ácidos Borônicos/metabolismo , Ácidos Borônicos/farmacologia , Linhagem Celular Tumoral , Proliferação de Células/efeitos dos fármacos , Cromatografia Líquida de Alta Pressão , Humanos , Modelos Lineares , Espectrometria de Massas , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Tiazóis/química , Tiazóis/metabolismo , Tiazóis/farmacologia
12.
J Anal Toxicol ; 44(8): 915-922, 2020 Dec 12.
Artigo em Inglês | MEDLINE | ID: mdl-32780823

RESUMO

Antipsychotic drugs (AP) are widely prescribed for the treatment of schizophrenia and psychosis. The pharmacological treatment of schizophrenia is often performed with the simultaneous use of two or more antipsychotic agents to achieve the desired control of psychotic symptoms Available AP include both conventional (typical) and new (atypical) antipsychotic medications. Atypical AP, such as quetiapine, now account for the vast majority of AP prescriptions. In forensic toxicology, AP are of considerable interest because of their potential abuse and their involvement in intoxications and suicides. The authors retrospectively examined AP positive cases detected in samples collected during autopsies performed in the Forensic Clinical and Pathology Service of National Institute of Legal Medicine and Forensic Sciences Centre Branch or in other autopsies carried out in the central region of Portugal, between January 2016 and December 2018. A quantitative liquid chromatography-tandem mass spectrometry assay was developed for the simultaneous determination of 16 AP (amisulpride, aripiprazole, chlorpromazine, clozapine, cyamemazine, fluphenazine, haloperidol, levomepromazine, melperone, olanzapine, paliperidone, promethazine, quetiapine, risperidone, sulpiride and ziprasidone) in blood samples of postmortem cases. The Laboratory of Forensic Chemistry and Toxicology received 3,588 requests for toxicological analysis: 1,413 cases were positive for drugs from which 351 (24.8%) cases were positive for AP, 60.1% from male individuals and 39.9% from female. Quetiapine was the most prevalent AP (36.5%) followed by olanzapine (20.8%). During this period, there were 25 postmortem cases with AP blood concentrations above therapeutic range, in which 36% of those are in agreement with the information received (psychological history or acute intoxication suspicion) and the manner of death was suicide. Our results point that antipsychotics are an increasingly prevalent class of drugs. AP must be measured not only in toxic concentrations but also in therapeutic levels in postmortem cases; therefore, it is important to come up with a sensitive method to cover the low therapeutic range in which AP are usually present.


Assuntos
Antipsicóticos/sangue , Detecção do Abuso de Substâncias/métodos , Adulto , Amissulprida/sangue , Aripiprazol/sangue , Benzodiazepinas/sangue , Cromatografia Líquida , Clozapina/sangue , Dibenzotiazepinas/sangue , Feminino , Toxicologia Forense , Humanos , Masculino , Olanzapina/sangue , Palmitato de Paliperidona/sangue , Piperazinas/sangue , Fumarato de Quetiapina/sangue , Estudos Retrospectivos , Risperidona/sangue , Esquizofrenia/tratamento farmacológico , Suicídio , Sulpirida/sangue , Espectrometria de Massas em Tandem , Tiazóis/sangue
13.
Rapid Commun Mass Spectrom ; 34(23): e8920, 2020 Dec 15.
Artigo em Inglês | MEDLINE | ID: mdl-32776613

RESUMO

RATIONALE: GW1516 is a peroxisome proliferator-activated receptor-δ agonist in the class of hormones and metabolic modulators. The use of GW1516 is banned in both horseracing and equestrian competitions. To the best of our knowledge, this is the first metabolic study of GW1516 in horses. METHODS: After protein precipitation of pre- and post-administration plasma GW1516 samples, the supernatants were analyzed using liquid chromatography/electrospray ionization Q-Exactive high-resolution mass spectrometry to detect GW1516 and its metabolites. Monoisotopic ions of GW1516 and its metabolites were monitored from the full-scan mass spectral data of pre- and post-administration samples. Quantification methods were developed and validated to establish the elimination profiles of GW1516, its sulfoxide, and its sulfone in equine plasma. RESULTS: GW1516 and its four metabolites GW1516 sulfoxide, GW1516 sulfone, 5-(hydroxymethyl)-4-methyl-2-(4-trifluoromethylphenyl)thiazole (HMTT), and M1 were detected in post-administration plasma samples. GW1516 sulfoxide, GW1516 sulfone, and HMTT were identified by comparison with their respective reference standards whereas M1 was tentatively identified as 4-methyl-2-[4-(trifluoromethyl)phenyl]-1,3-thiazole-5-carboxylic acid by mass spectral interpretation. GW1516 had the longest detection time in post-administration plasma. The elimination profiles of GW1516, its sulfoxide, and its sulfone in plasma were established. CONCLUSIONS: For the purpose of doping control, GW1516 is recommended as the target analyte to be monitored in equine plasma due to its long detection time (around 1 week) and the ready availability of its reference material.


Assuntos
Cromatografia Líquida/métodos , Dopagem Esportivo , Cavalos/sangue , Espectrometria de Massas por Ionização por Electrospray/métodos , Tiazóis/sangue , Administração Intranasal , Animais , Feminino , Limite de Detecção , Modelos Lineares , Reprodutibilidade dos Testes , Tiazóis/administração & dosagem , Tiazóis/química , Tiazóis/farmacocinética
14.
Artigo em Inglês | MEDLINE | ID: mdl-32480321

RESUMO

RN104, named 2-[2-(cyclohexylmethylene)hydrazinyl)]-4-phenylthiazole, is a thiazolyl hydrazone derivative with promising antifungal activity. Pharmacokinetic profile of the RN104 was evaluated in mice plasma using a developed and validated bioanalytical method by LC-MS/MS. Clotrimazole was used as internal standard. The analytes were extracted by a protein precipitation procedure and separated on a C18 end-capped column and mobile phase composed of acetonitrile - 0.1% formic acid (85:15, v/v), in isocratic mode. Electrospray ionization in positive ionization mode (ESI + ) and multiple reaction monitoring (MRM) were employed using the transitions m/z 286.1 â†’ m/z 176.1 (quantifier) and m/z 286.1 â†’ m/z 112.2 (qualifier) for RN104 and m/z 345.2 â†’ m/z 277.1 (quantifier) and m/z 345.2 â†’ m/z 165.2 (qualifier) for internal standard. The method was validated and proved to be linear, accurate, precise, and selective over the range 0.625 to 40.0 ng/mL. The pharmacokinetic model that best fit the data was the bicompartmental model. The maximum plasmatic concentration was reached 20 min after administration (per os and intraperitoneal) and the highest plasma concentration of RN104 was found after per os administration at a dosage of 50 mg/kg compared to i.p. administration at 10 mg/kg.


Assuntos
Antifúngicos/sangue , Cromatografia Líquida/métodos , Hidrazonas/sangue , Espectrometria de Massas em Tandem/métodos , Tiazóis/sangue , Animais , Antifúngicos/química , Antifúngicos/farmacocinética , Feminino , Hidrazonas/química , Hidrazonas/farmacocinética , Modelos Lineares , Camundongos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Espectrometria de Massas por Ionização por Electrospray , Tiazóis/química , Tiazóis/farmacocinética
15.
Artigo em Inglês | MEDLINE | ID: mdl-32361632

RESUMO

Edoxaban is mainly enzymatically converted to a 4-carboxylic acid form (4CA-EDX) and an N-desmethyl form (ND-EDX) in humans. This study aimed to establish a simple liquid chromatography-tandem mass spectrometry method using core-shell octadecyl silica (ODS) microparticles for the simultaneous quantitation of edoxaban and its two major metabolites in human plasma. Analytes extracted from plasma specimens by a one-step deproteinization were separated using a 2.6-µm core-shell ODS microparticulate column and linear acetonitrile-ammonium acetate gradient elution at a flow rate of 0.25 mL/min with a run time of 7 min. The mass spectrometer was operated in the positive ion multiple reaction monitoring mode. Plasma samples collected from 20 patients with atrial fibrillation were analyzed by the present method. The chromatograms of drug-free human plasma had no interfering peaks. The calibration curves of edoxaban, 4CA-EDX, and ND-EDX were linear over the concentration ranges of 1.25-160, 0.47-60, and 0.12-15 ng/mL, respectively. Their pretreatment recoveries and matrix factors were 88.7-109.0% and 87.0-101.6%, respectively. The intra- and inter-day accuracy and imprecision values were 85.9-112.8% and within 13.3%, respectively. The plasma concentrations of edoxaban, 4CA-EDX, and ND-EDX in the patients had ranges of 17.8-102, 1.67-25.7, and 0.685-5.34 ng/mL, respectively. All the analytes were measurable within their calibration curves. In conclusion, this validated method for the simultaneous determination of edoxaban and its major metabolites was successfully applied to plasma specimens obtained from patients with atrial fibrillation.


Assuntos
Piridinas/sangue , Piridinas/farmacocinética , Espectrometria de Massas em Tandem/métodos , Tiazóis/sangue , Tiazóis/farmacocinética , Técnicas Biossensoriais , Coleta de Amostras Sanguíneas , Cromatografia Líquida de Alta Pressão , Humanos , Limite de Detecção , Metabolômica , Microesferas , Padrões de Referência , Reprodutibilidade dos Testes , Sensibilidade e Especificidade , Dióxido de Silício/química
16.
J Thromb Thrombolysis ; 50(3): 632-639, 2020 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-32436010

RESUMO

Edoxaban, alongside other direct oral anticoagulants (DOAC), is increasingly used for prevention of thromboembolism, including stroke. Despite DOAC therapy, however, annual stroke rate in patients with atrial fibrillation remains 1-2%. Rapid exclusion of relevant anticoagulation is necessary to guide thrombolysis or reversal therapy but, so far, no data exists on the effect of edoxaban on available point-of-care test systems (POCT). To complete our previous investigation on global coagulation-POCT for the detection of DOAC, we evaluated whether CoaguChek®-INR (CC-INR) is capable of safely ruling out edoxaban concentrations above the current treatment thresholds of 30/50 ng/mL in a blood sample. We studied patients receiving a first dose of edoxaban; excluding subjects receiving other anticoagulants. Six blood samples were collected from each patient: before drug intake, 0.5, 1, 2 and 8 h after intake, and at trough (24 h). CC-INR and mass spectrometry for edoxaban concentrations were performed for each time-point. One hundred and twenty blood samples from 20 patients contained 0-302 ng/mL of edoxaban. CC-INR ranged from 0.9 to 2.3. Pearson's correlation coefficient showed strong correlation between CC-INR and edoxaban concentrations (r = 0.73, p < 0.001). Edoxaban concentrations > 30 and > 50 ng/mL were ruled out by CC-INR ≤ 1.0 and ≤ 1.1, respectively, with high specificity (> 95%), and a sensitivity of 44% (95%-confidence interval: 30-59%) and 86% (74-93%), respectively. Our study represents the first evaluation of coagulation-POCT in edoxaban-treated patients. CC-POCT is suitable to safely exclude clinically relevant edoxaban concentrations prior to thrombolysis, or guide reversal therapy in stroke patients.


Assuntos
Coagulação Sanguínea/efeitos dos fármacos , Inibidores do Fator Xa/uso terapêutico , Piridinas/uso terapêutico , Tiazóis/uso terapêutico , Idoso , Fibrilação Atrial/tratamento farmacológico , Testes de Coagulação Sanguínea , Monitoramento de Medicamentos , Inibidores do Fator Xa/sangue , Inibidores do Fator Xa/farmacologia , Feminino , Humanos , Coeficiente Internacional Normatizado , Masculino , Pessoa de Meia-Idade , Testes Imediatos , Estudos Prospectivos , Piridinas/sangue , Piridinas/farmacologia , Acidente Vascular Cerebral/tratamento farmacológico , Tiazóis/sangue , Tiazóis/farmacologia
17.
Drugs R D ; 20(3): 217-223, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32415538

RESUMO

BACKGROUND AND OBJECTIVE: Based on previous experience of sorbent-mediated ticagrelor, dabigatran, and radiocontrast agent removal, we set out in this study to test the effect of two sorbents on the removal of edoxaban, a factor Xa antagonist direct oral anticoagulant. METHODS: We circulated 100 mL of edoxaban solution during six first-pass cycles through 40-mL sorbent columns (containing either CytoSorb in three passes or Porapak Q 50-80 mesh in the remaining three passes) during experiments using human plasma and 4% bovine serum albumin solution as drug vehicles. Drug concentration was measured by liquid chromatography-tandem mass spectrometry. RESULTS: Edoxaban concentration in two experiments performed with human plasma dropped from 276.8 to 2.7 ng/mL and undetectable concentrations, respectively, with CytoSorb or Porapak Q 50-80 mesh (p = 0.0031). The average edoxaban concentration decreased from 407 ng/mL ± 216 ng/mL to 3.3 ng/mL ± 7 ng/mL (p = 0.017), for a removal rate of 99% across all six samples of human plasma (two samples) and bovine serum albumin solution (four samples). In four out of the six adsorbed samples, the drug concentrations were undetectable. CONCLUSION: Sorbent-mediated technology may represent a viable pathway for edoxaban removal from human plasma or albumin solution.


Assuntos
Inibidores do Fator Xa/sangue , Piridinas/sangue , Tiazóis/sangue , Adsorção , Albuminas/química , Cromatografia Líquida , Inibidores do Fator Xa/química , Humanos , Piridinas/química , Estirenos/química , Tiazóis/química
19.
J Thromb Haemost ; 18(6): 1320-1323, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32329231

RESUMO

BACKGROUND: Antiviral drugs are administered in patients with severe COVID-19 respiratory syndrome, including those treated with direct oral anticoagulants (DOACs). Concomitant administration of antiviral agents has the potential to increase their plasma concentration. A series of patients managed in the Cremona Thrombosis Center were admitted at Cremona Hospital for SARS-CoV-2 and started antiviral drugs without stopping DOAC therapy. DOAC plasma levels were measured in hospital and results compared with those recorded before hospitalization. METHODS: All consecutive patients on DOACs were candidates for administration of antiviral agents (lopinavir, ritonavir, or darunavir). Plasma samples for DOAC measurement were collected 2to 4 days after starting antiviral treatment, at 12 hours from the last dose intake in patients on dabigatran and apixaban, and at 24 hours in those on rivaroxaban and edoxaban. For each patient, C-trough DOAC level, expressed as ng/mL, was compared with the one measured before hospitalization. RESULTS: Of the 1039 patients hospitalized between February 22 and March 15, 2020 with COVID-19 pneumonia and candidates for antiviral therapy, 32 were on treatment with a DOAC. DOAC was stopped in 20 and continued in the remaining 12. On average, C-trough levels were 6.14 times higher during hospitalization than in the pre-hospitalization period. CONCLUSION: DOAC patients treated with antiviral drugs show an alarming increase in DOAC plasma levels. In order to prevent bleeding complications, we believe that physicians should consider withholding DOACs from patients with SARS-CoV-2 and replacing them with alternative parenteral antithrombotic strategies for as long as antiviral agents are deemed necessary and until discharge.


Assuntos
Antitrombinas/sangue , Antivirais/efeitos adversos , Betacoronavirus/efeitos dos fármacos , Infecções por Coronavirus/tratamento farmacológico , Dabigatrana/sangue , Inibidores do Fator Xa/sangue , Pneumonia Viral/tratamento farmacológico , Pirazóis/sangue , Piridinas/sangue , Piridonas/sangue , Tiazóis/sangue , Administração Oral , Idoso , Idoso de 80 Anos ou mais , Antitrombinas/administração & dosagem , Antitrombinas/efeitos adversos , Antivirais/administração & dosagem , Betacoronavirus/patogenicidade , COVID-19 , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/virologia , Dabigatrana/administração & dosagem , Dabigatrana/efeitos adversos , Darunavir/efeitos adversos , Interações Medicamentosas , Monitoramento de Medicamentos , Inibidores do Fator Xa/administração & dosagem , Inibidores do Fator Xa/efeitos adversos , Feminino , Hemorragia/induzido quimicamente , Humanos , Itália , Lopinavir/efeitos adversos , Masculino , Pandemias , Segurança do Paciente , Pneumonia Viral/diagnóstico , Pneumonia Viral/virologia , Pirazóis/administração & dosagem , Pirazóis/efeitos adversos , Piridinas/administração & dosagem , Piridinas/efeitos adversos , Piridonas/administração & dosagem , Piridonas/efeitos adversos , Medição de Risco , Fatores de Risco , Ritonavir/efeitos adversos , SARS-CoV-2 , Índice de Gravidade de Doença , Tiazóis/administração & dosagem , Tiazóis/efeitos adversos
20.
J Chromatogr Sci ; 58(6): 562-568, 2020 Jun 05.
Artigo em Inglês | MEDLINE | ID: mdl-32303742

RESUMO

A simple and accurate chiral liquid chromatographic method was developed for enantiomeric resolution and determination of 2-(5-fluoro-2-hydroxyphenyl)-2-(1-oxo-2,3-dihydro-1H-isoindol-2-yl)-N-(1,3-thiazol-2-yl)acetamide (EAI045). The enantiomers of EAI045 were baseline resolved on a Chiralpak AD-H (250 mm × 4.6 mm, 5 µm) column using a mobile phase system containing n-hexane: 2-propanol (75: 25 v/v) at a flow rate of 1 mL min-1 at 30°C. The eluted analytes were subsequently detected with an ultraviolet detector at 254 nm. The effects of organic modifiers and temperature on the enantioselectivity and resolution of the enantiomers were evaluated. The calibration curves were plotted within the concentration range between 2 and 600 µg mL-1 (n = 11), and recoveries between 98.74% and 101.52% were obtained, with relative standard deviation < 1.4%. The limit of detection and limit of quantitation for R-enantiomer were 0.94 and 3.07 µg mL-1 and for S-enantiomer were 0.86 and 2.84 µg mL-1, respectively. The validated method was found to be suitable for enantiomeric separation and sufficiently accurate for the determination of enantiomeric purity of EAI045 in bulk drugs.


Assuntos
Benzenoacetamidas , Cromatografia Líquida/métodos , Tiazóis , Amilose/análogos & derivados , Amilose/química , Animais , Benzenoacetamidas/sangue , Benzenoacetamidas/química , Benzenoacetamidas/isolamento & purificação , Benzenoacetamidas/farmacocinética , Limite de Detecção , Modelos Lineares , Camundongos , Fenilcarbamatos/química , Reprodutibilidade dos Testes , Estereoisomerismo , Tiazóis/sangue , Tiazóis/química , Tiazóis/isolamento & purificação , Tiazóis/farmacocinética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA