Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 11.955
Filtrar
1.
Sci Rep ; 14(1): 10597, 2024 05 08.
Artigo em Inglês | MEDLINE | ID: mdl-38719924

RESUMO

Parotid lumps are a heterogeneous group of mainly benign but also malignant tumors. Preoperative imaging does not allow a differentiation between tumor types. Multispectral optoacoustic tomography (MSOT) may improve the preoperative diagnostics. In this first prospective pilot trial the ability of MSOT to discriminate between the two most frequent benign parotid tumors, pleomorphic adenoma (PA) and Warthin tumor (WT) as well as to normal parotid tissue was explored. Six wavelengths (700, 730, 760, 800, 850, 900 nm) and the parameters deoxygenated (HbR), oxygenated (HbO2), total hemoglobin (HbT), and saturation of hemoglobin (sO2) were analyzed. Ten patients with PA and fourteen with WT were included (12/12 female/male; median age: 51 years). For PA, the mean values for all measured wave lengths as well as for the hemoglobin parameters were different for the tumors compared to the healthy parotid (all p < 0.05). The mean MSOT parameters were all significantly higher (all p < 0.05) in the WT compared to healthy parotid gland except for HbT and sO2. Comparing both tumors directly, the mean values of MSOT parameters were not different between PA and WT (all p > 0.05). Differences were seen for the maximal MSOT parameters. The maximal tumor values for 900 nm, HbR, HbT, and sO2 were lower in PA than in WT (all p < 0.05). This preliminary MSOT parotid tumor imaging study showed clear differences for PA or WT compared to healthy parotid tissue. Some MSOT characteristics of PA and WT were different but needed to be explored in larger studies.


Assuntos
Neoplasias Parotídeas , Técnicas Fotoacústicas , Humanos , Feminino , Neoplasias Parotídeas/diagnóstico por imagem , Neoplasias Parotídeas/patologia , Pessoa de Meia-Idade , Masculino , Projetos Piloto , Estudos Prospectivos , Técnicas Fotoacústicas/métodos , Adulto , Idoso , Hemoglobinas/análise , Hemoglobinas/metabolismo , Adenolinfoma/diagnóstico por imagem , Adenolinfoma/patologia , Adenoma Pleomorfo/diagnóstico por imagem , Adenoma Pleomorfo/patologia , Tomografia/métodos , Glândula Parótida/diagnóstico por imagem , Glândula Parótida/patologia
2.
Physiol Meas ; 45(5)2024 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-38697210

RESUMO

Objective.Electrical impedance tomography (EIT) produces clinical useful visualization of the distribution of ventilation inside the lungs. The accuracy of EIT-derived parameters can be compromised by the cardiovascular signal. Removal of these artefacts is challenging due to spectral overlapping of the ventilatory and cardiovascular signal components and their time-varying frequencies. We designed and evaluated advanced filtering techniques and hypothesized that these would outperform traditional low-pass filters.Approach.Three filter techniques were developed and compared against traditional low-pass filtering: multiple digital notch filtering (MDN), empirical mode decomposition (EMD) and the maximal overlap discrete wavelet transform (MODWT). The performance of the filtering techniques was evaluated (1) in the time domain (2) in the frequency domain (3) by visual inspection. We evaluated the performance using simulated contaminated EIT data and data from 15 adult and neonatal intensive care unit patients.Main result.Each filter technique exhibited varying degrees of effectiveness and limitations. Quality measures in the time domain showed the best performance for MDN filtering. The signal to noise ratio was best for DLP, but at the cost of a high relative and removal error. MDN outbalanced the performance resulting in a good SNR with a low relative and removal error. MDN, EMD and MODWT performed similar in the frequency domain and were successful in removing the high frequency components of the data.Significance.Advanced filtering techniques have benefits compared to traditional filters but are not always better. MDN filtering outperformed EMD and MODWT regarding quality measures in the time domain. This study emphasizes the need for careful consideration when choosing a filtering approach, depending on the dataset and the clinical/research question.


Assuntos
Artefatos , Impedância Elétrica , Processamento de Sinais Assistido por Computador , Tomografia , Humanos , Tomografia/métodos , Razão Sinal-Ruído , Adulto , Análise de Ondaletas , Sistema Cardiovascular , Recém-Nascido
3.
Methods Cell Biol ; 187: 139-174, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38705623

RESUMO

Array tomography (AT) allows one to localize sub-cellular components within the structural context of cells in 3D through the imaging of serial sections. Using this technique, the z-resolution can be improved physically by cutting ultra-thin sections. Nevertheless, conventional immunofluorescence staining of those sections is time consuming and requires relatively large amounts of costly antibody solutions. Moreover, epitopes are only readily accessible at the section's surface, leaving the volume of the serial sections unlabeled. Localization of receptors at neuronal synapses in 3D in their native cellular ultrastructural context is important for understanding signaling processes. Here, we present in vivo labeling of receptors via fluorophore-coupled tags in combination with super-resolution AT. We present two workflows where we label receptors at the plasma membrane: first, in vivo labeling via microinjection with a setup consisting of readily available components and self-manufactured microscope table equipment and second, live receptor labeling by using a cell-permeable tag. To take advantage of a near-to-native preservation of tissues for subsequent scanning electron microscopy (SEM), we also apply high-pressure freezing and freeze substitution. The advantages and disadvantages of our workflows are discussed.


Assuntos
Sinapses , Tomografia , Animais , Sinapses/metabolismo , Sinapses/ultraestrutura , Tomografia/métodos , Imageamento Tridimensional/métodos , Coloração e Rotulagem/métodos , Camundongos , Microscopia Eletrônica de Varredura/métodos , Corantes Fluorescentes/química , Microinjeções/métodos , Neurônios/metabolismo , Ratos
4.
PLoS One ; 19(5): e0302476, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38709742

RESUMO

BACKGROUND: The Incentive Spirometer (IS) increases lung volume and improves gas exchange by visually stimulating patients to take slow, deep breaths. It prevents respiratory complications and treats postoperative atelectasis in patients undergoing abdominal, thoracic, and neurosurgical procedures. Its effectiveness has been validated in studies that support improved lung capacities and volumes in individuals with respiratory complications, postoperative thoracic surgery, upper abdominal surgery, and bariatric surgery. The modified Pachón incentive spirometer (MPIS) is a cost-effective alternative to branded IS. It is crucial to validate whether the MPIS distributes ventilation as effectively as commercial devices do. Ventilation distribution will be measured using electrical impedance tomography. OBJECTIVE: The aim is to compare the distribution of pulmonary ventilation between the MPIS and another commercial IS in healthy adults using electrical impedance tomography. METHODS: A crossover clinical trial is proposed to evaluate the measurement of pulmonary ventilation distribution using EIT in a sample of healthy adults. All participants will use a commercial flow IS and the MPIS, with the order of assignment randomized. This research will use electrical impedance tomography to validate the operation of the MPIS. CONCLUSIONS: This study protocol will compare two incentive spirometers' impact on pulmonary ventilation, potentially endorsing the adoption of a cost-effective device to enhance accessibility for targeted populations. TRIAL REGISTRATION: The study was registered in ClinicalTrials.gov (NTC05532748).


Assuntos
Impedância Elétrica , Ventilação Pulmonar , Espirometria , Tomografia , Humanos , Adulto , Espirometria/métodos , Espirometria/instrumentação , Tomografia/métodos , Ventilação Pulmonar/fisiologia , Masculino , Feminino , Voluntários Saudáveis , Estudos Cross-Over , Pulmão/fisiologia , Pessoa de Meia-Idade , Adulto Jovem
5.
Nat Commun ; 15(1): 4228, 2024 May 18.
Artigo em Inglês | MEDLINE | ID: mdl-38762498

RESUMO

Cross-modal analysis of the same whole brain is an ideal strategy to uncover brain function and dysfunction. However, it remains challenging due to the slow speed and destructiveness of traditional whole-brain optical imaging techniques. Here we develop a new platform, termed Photoacoustic Tomography with Temporal Encoding Reconstruction (PATTERN), for non-destructive, high-speed, 3D imaging of ex vivo rodent, ferret, and non-human primate brains. Using an optimally designed image acquisition scheme and an accompanying machine-learning algorithm, PATTERN extracts signals of genetically-encoded probes from photobleaching-based temporal modulation and enables reliable visualization of neural projection in the whole central nervous system with 3D isotropic resolution. Without structural and biological perturbation to the sample, PATTERN can be combined with other whole-brain imaging modalities to acquire the whole-brain image with both high resolution and morphological fidelity. Furthermore, cross-modal transcriptome analysis of an individual brain is achieved by PATTERN imaging. Together, PATTERN provides a compatible and versatile strategy for brain-wide cross-modal analysis at the individual level.


Assuntos
Encéfalo , Furões , Imageamento Tridimensional , Técnicas Fotoacústicas , Animais , Encéfalo/diagnóstico por imagem , Técnicas Fotoacústicas/métodos , Imageamento Tridimensional/métodos , Camundongos , Algoritmos , Aprendizado de Máquina , Tomografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Ratos , Masculino
6.
J Gastrointest Surg ; 28(4): 375-380, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38583886

RESUMO

PURPOSE: This study aimed to investigate the correlation between sarcopenia and adverse events (AEs) of postoperative imatinib therapy through computed tomography (CT) quantitative body composition for intermediate- and high-risk gastrointestinal stromal tumors (GISTs). METHODS: The study retrospectively analyzed the clinical data of 208 patients with intermediate- and high-risk GIST treated surgically and treated with imatinib afterward at the First Affiliated Hospital of Wenzhou Medical University between October 2011 and October 2021. Images of preoperative CT scans within 1 month were used to determine the body composition of the patients. On the basis of the L3 skeletal muscle index, patients were classified into sarcopenia and nonsarcopenia groups. In 2 groups, AEs related to imatinib were analyzed. RESULTS: The proportion of AEs related to imatinib in the sarcopenia group was higher, and this disparity had a significant statistical significance (P = .013). Sarcopenia was significantly associated with hemoglobin reduction compared with nonsarcopenia (P = .015). There was a significant difference between the sarcopenia group and the nonsarcopenia group in the ratio of severe AEs (grades 3-4). Hemoglobin content (odds ratio [OR], 0.981; 95% CI, 0.963-1.000; P = .045), sex (OR, 0.416; 95% CI, 0.192-0.904; P = .027), and sarcopenia (OR, 5.631; 95% CI, 2.262-14.014; P < .001) were the influential factors of imatinib severe AEs in patients with intermediate- and high-risk GIST within 1 year after imatinib treatment. CONCLUSION: Patients with preoperative sarcopenia have a higher incidence and severity of AEs during adjuvant imatinib therapy.


Assuntos
Antineoplásicos , Tumores do Estroma Gastrointestinal , Sarcopenia , Humanos , Mesilato de Imatinib/efeitos adversos , Tumores do Estroma Gastrointestinal/diagnóstico por imagem , Tumores do Estroma Gastrointestinal/tratamento farmacológico , Tumores do Estroma Gastrointestinal/cirurgia , Estudos Retrospectivos , Sarcopenia/induzido quimicamente , Sarcopenia/diagnóstico por imagem , Quimioterapia Adjuvante , Hemoglobinas , Tomografia , Antineoplásicos/efeitos adversos
7.
Int Braz J Urol ; 50(3): 250-260, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38598828

RESUMO

BACKGROUND: Success rates in endourological procedures, notably percutaneous nephrolithotomy (PCNL) and ureteroscopy (URS), have demonstrated suboptimal outcomes, leading to more reinterventions and radiation exposure. Recently, the use of intraoperative computed tomography (ICT) scans has been hypothesized as a promising solution for improving outcomes in endourology procedures. With this considered, we conducted a comprehensive systematic review and meta-analysis encompassing all available studies that evaluate the impact of the use of intraoperative CT scans on surgical outcomes compared to conventional fluoroscopic-guided procedures. METHODS: This systematic review was conducted in accordance with PRISMA guidelines. Multiple databases were systematically searched up to December of 2023. This study aimed to directly compare the use of an ICT scan with the standard non-ICT-guided procedure. The primary endpoint of interest was success rate, and the secondary endpoints were complications and reintervention rates, while radiation exposure was also evaluated. Data extraction and quality assessment were performed following Cochrane recommendations. Data was presented as an Odds ratio with 95%CI across trials and a random-effects model was selected for pooling of data. RESULTS: A comprehensive search yielded 533 studies, resulting in the selection of 3 cohorts including 327 patients (103 ICT vs 224 in non-ICT). Primary outcome was significantly higher in the experimental group versus the control group (84.5% vs 41.4% respectively, 307 patients; 95% CI [3.61, 12.72]; p<0.00001; I2=0). Reintervention rates also decreased from 32.6% in the control to 12.6% in the ICT group (OR 0.34; 95%CI [0.12,0.94]; p =0.04; I2= 48%), whereas complication rates did not exhibit significant differences. Radiation exposure was also significantly reduced in two of the included studies. CONCLUSION: This meta-analysis highlights a favorable outcome with intraoperative CT scan use in PCNL procedures, showing a considerable increase in SFR when compared to standard fluoroscopy and nephroscopy. Despite limited studies, our synthesis underscores the potential of ICT scans to significantly reduce residual stones and their consequences for endourology patients, as reinterventions and follow-up ionizing radiation studies.


Assuntos
Cálculos Renais , Nefrolitotomia Percutânea , Humanos , Cálculos Renais/diagnóstico por imagem , Cálculos Renais/cirurgia , Cálculos Renais/etiologia , Nefrolitotomia Percutânea/métodos , Rim , Ureteroscopia/métodos , Tomografia , Resultado do Tratamento
8.
Physiol Meas ; 45(4)2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38624240

RESUMO

Objective.Electrical impedance tomography (EIT) is a noninvasive imaging method whereby electrical measurements on the periphery of a heterogeneous conductor are inverted to map its internal conductivity. The EIT method proposed here aims to improve computational speed and noise tolerance by introducing sensitivity volume as a figure-of-merit for comparing EIT measurement protocols.Approach.Each measurement is shown to correspond to a sensitivity vector in model space, such that the set of measurements, in turn, corresponds to a set of vectors that subtend a sensitivity volume in model space. A maximal sensitivity volume identifies the measurement protocol with the greatest sensitivity and greatest mutual orthogonality. A distinguishability criterion is generalized to quantify the increased noise tolerance of high sensitivity measurements.Main result.The sensitivity volume method allows the model space dimension to be minimized to match that of the data space, and the data importance to be increased within an expanded space of measurements defined by an increased number of contacts.Significance.The reduction in model space dimension is shown to increasecomputational efficiency, accelerating tomographic inversion by several orders of magnitude, while the enhanced sensitivitytolerates higher noiselevels up to several orders of magnitude larger than standard methods.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Impedância Elétrica , Tomografia/métodos , Condutividade Elétrica
9.
Physiol Meas ; 45(4)2024 Apr 18.
Artigo em Inglês | MEDLINE | ID: mdl-38565126

RESUMO

Objective.The objective of this study was to propose a novel data-driven method for solving ill-posed inverse problems, particularly in certain conditions such as time-difference electrical impedance tomography for detecting the location and size of bubbles inside a pipe.Approach.We introduced a new layer architecture composed of three paths: spatial, spectral, and truncated spectral paths. The spatial path processes information locally, whereas the spectral and truncated spectral paths provide the network with a global receptive field. This unique architecture helps eliminate the ill-posedness and nonlinearity inherent in the inverse problem. The three paths were designed to be interconnected, allowing for an exchange of information on different receptive fields with varied learning abilities. Our network has a bottleneck architecture that enables it to recover signal information from noisy redundant measurements. We named our proposed model truncated spatial-spectral convolutional neural network (TSS-ConvNet).Main results.Our model demonstrated superior accuracy with relatively high resolution on both simulation and experimental data. This indicates that our approach offers significant potential for addressing ill-posed inverse problems in complex conditions effectively and accurately.Significance.The TSS-ConvNet overcomes the receptive field limitation found in most existing models that only utilize local information in Euclidean space. We trained the network on a large dataset covering various configurations with random parameters to ensure generalization over the training samples.


Assuntos
Tomografia Computadorizada por Raios X , Tomografia , Tomografia/métodos , Impedância Elétrica , Redes Neurais de Computação , Processamento de Imagem Assistida por Computador/métodos
10.
World J Urol ; 42(1): 238, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627315

RESUMO

BACKGROUND: Accurate estimation of the glomerular filtration rate (GFR) is clinically crucial for determining the status of obstruction, developing treatment strategies, and predicting prognosis in obstructive nephropathy (ON). We aimed to develop a deep learning-based system, named UroAngel, for non-invasive and convenient prediction of single-kidney function level. METHODS: We retrospectively collected computed tomography urography (CTU) images and emission computed tomography diagnostic reports of 520 ON patients. A 3D U-Net model was used to segment the renal parenchyma, and a logistic regression multi-classification model was used to predict renal function level. We compared the predictive performance of UroAngel with the Modification of Diet in Renal Disease (MDRD), Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equations, and two expert radiologists in an additional 40 ON patients to validate clinical effectiveness. RESULTS: UroAngel based on 3D U-Net convolutional neural network could segment the renal cortex accurately, with a Dice similarity coefficient of 0.861. Using the segmented renal cortex to predict renal function stage had high performance with an accuracy of 0.918, outperforming MDRD and CKD-EPI and two radiologists. CONCLUSIONS: We proposed an automated 3D U-Net-based analysis system for direct prediction of single-kidney function stage from CTU images. UroAngel could accurately predict single-kidney function in ON patients, providing a novel, reliable, convenient, and non-invasive method.


Assuntos
Aprendizado Profundo , Insuficiência Renal Crônica , Rim Único , Humanos , Estudos Retrospectivos , Rim/diagnóstico por imagem , Insuficiência Renal Crônica/diagnóstico , Taxa de Filtração Glomerular , Tomografia , Creatinina
11.
Zhonghua Yi Xue Za Zhi ; 104(15): 1247-1252, 2024 Apr 16.
Artigo em Chinês | MEDLINE | ID: mdl-38637164

RESUMO

Acute respiratory distress syndrome (ARDS) is a common and critical clinical condition characterized by diffuse damage to the lung interstitium, alveoli, and increased permeability of pulmonary blood vessels. CT can be used to assess the imaging features, severity, and prediction of ARDS, but it requires patient transportation to the CT room and is only a static examination. Electrical impedance tomography (EIT) is an increasingly widely used monitoring tool in clinical applications in recent years. It enables continuous real-time assessment of lung ventilation distribution at the bedside and has high clinical value in optimizing mechanical ventilation parameters for critically ill patients. This article introduces the basic principles of EIT and how to better utilize EIT technology to guide mechanical ventilation treatment for ARDS patients.


Assuntos
Respiração Artificial , Síndrome do Desconforto Respiratório , Humanos , Respiração Artificial/métodos , Impedância Elétrica , Tomografia/métodos , Síndrome do Desconforto Respiratório/terapia , Tomografia Computadorizada por Raios X/métodos , Pulmão
12.
Gen Dent ; 72(3): 50-55, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38640006

RESUMO

The objective of this retrospective study was to assess the bone quality of healing mandibular fracture sites by measuring the Hounsfield units (HU) on computed tomographic (CT) images obtained presurgery and postsurgery in patients treated with rigid internal fixation (RIF). The HU values of healing fracture sites were compared to those of corresponding nonfractured (control) sites on the opposing side and cervical vertebrae sites in the same patients. In total, 31 patients with 45 mandibular fractures treated with RIF underwent presurgical and postsurgical CT examinations. The scans performed after surgery (1, 3, 6, 12, or 18 months) were taken only when there was a need for radiographic evaluation due to a complaint of discomfort from the patient or when the surgeon needed to verify the postsurgical outcome, and each patient underwent only a single postsurgical CT. At the presurgical CT examination, the HU values were lower in the fracture sites than in the control sites. At 3 months postsurgery, the HU values in the fracture sites had increased as the mandibular bone healed. At 6 months postsurgery, the HU values in the fracture sites were higher than those of the control sites. At 12 and 18 months postsurgery, the HU values of both sites were similar. The HU values of the cervical vertebrae remained constant with time. These results suggest that, in patients who have been treated with RIF for mandibular bone fracture, HU values measured by CT vary across time, expressing the physiologic bone healing process.


Assuntos
Densidade Óssea , Fraturas Mandibulares , Humanos , Estudos Retrospectivos , Densidade Óssea/fisiologia , Fraturas Mandibulares/diagnóstico por imagem , Fraturas Mandibulares/cirurgia , Tomografia Computadorizada por Raios X/métodos , Tomografia
13.
Phys Med Biol ; 69(11)2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38640922

RESUMO

Objective.Modern medical imaging plays a vital role in clinical practice, enabling non-invasive visualization of anatomical structures. Dynamic contrast enhancement (DCE) imaging is a technique that uses contrast agents to visualize blood flow dynamics in a time-resolved manner. It can be applied to different modalities, such as computed tomography (CT) and electrical impedance tomography (EIT). This study aims to develop a common theoretical and practical hemodynamic extraction basis for DCE modelling across modalities, based on the gamma-variate function.Approach.The study introduces a framework to generate time-intensity curves for multiple DCE imaging modalities from user-defined hemodynamic parameters. Thus, extensive datasets were simulated for both DCE-CT and EIT, representing different hemodynamic scenarios. Additionally, gamma-variate extensions to account for several physiological effects were detailed in a modality-agnostic manner, and three corresponding fitting strategies, namely nonlinear, linear, and a novel hybrid approach, were implemented and compared on the basis of accuracy of parameter estimation, first pass reconstruction, speed of computation, and failure rate.Main results.As a result, we found the linear method to be the most modality-dependent, exhibiting the greatest bias, variance and failure rates, although remaining the fastest alternative. The hybrid method at least matches the state-of-the-art nonlinear method's accuracy, while improving its robustness and speed by 10 times.Significance.Our research suggests that the hybrid method may bring noteworthy accuracy and efficiency improvements in handling the high-dimensionality of DCE imaging in general, being a step towards real-time processing. Moreover, our generative model presents a potential asset to produce benchmarking and data augmentation datasets across modalities.


Assuntos
Meios de Contraste , Impedância Elétrica , Processamento de Imagem Assistida por Computador , Tomografia , Tomografia/métodos , Processamento de Imagem Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Humanos , Hemodinâmica
14.
Crit Care ; 28(1): 124, 2024 04 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627745

RESUMO

Extracorporeal Carbon Dioxide Removal (ECCO2R) is used in acute respiratory distress syndrome (ARDS) patients to facilitate lung-protective ventilatory strategies. Electrical Impedance Tomography (EIT) allows individual, non-invasive, real-time, bedside, radiation-free imaging of the lungs, providing global and regional dynamic lung analyses. To provide new insights for future ECCO2R research in ARDS, we propose a potential application of EIT to personalize End-Expiratory Pressure (PEEP) following each reduction in tidal volume (VT), as demonstrated in an illustrative case. A 72-year-old male with COVID-19 was admitted to the ICU for moderate ARDS. Monitoring with EIT was started to determine the optimal PEEP value (PEEPEIT), defined as the intersection of the collapse and overdistention curves, after each reduction in VT during ECCO2R. The identified PEEPEIT values were notably low (< 10 cmH2O). The decrease in VT associated with PEEPEIT levels resulted in improved lung compliance, reduced driving pressure and a more uniform ventilation pattern. Despite current Randomized Controlled Trials showing that ultra-protective ventilation with ECCO2R does not improve survival, the applicability of universal ultra-protective ventilation settings for all patients remains a subject of debate. Inappropriately set PEEP levels can lead to alveolar collapse or overdistension, potentially negating the benefits of VT reduction. EIT facilitates real-time monitoring of derecruitment associated with VT reduction, guiding physicians in determining the optimal PEEP value after each decrease in tidal volume. This original description of using EIT under ECCO2R to adjust PEEP at a level compromising between recruitability and overdistention could be a crucial element for future research on ECCO2R.


Assuntos
Respiração com Pressão Positiva , Síndrome do Desconforto Respiratório , Masculino , Humanos , Idoso , Impedância Elétrica , Respiração com Pressão Positiva/métodos , Pulmão , Tomografia Computadorizada por Raios X , Síndrome do Desconforto Respiratório/terapia , Volume de Ventilação Pulmonar , Tomografia/métodos
15.
Waste Manag ; 182: 215-224, 2024 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-38670005

RESUMO

Incidents of waste and biofuel fires are common at all stages of the waste recycling chain and have grave implications for business, employees, firefighters, society, and environment. An early detection of waste and biofuel fires in the smouldering stage could save precious lives, resources, and our environment. Existing fire detection methodologies e.g. handheld temperature sensors, IR cameras, gas sensors, and video and satellite-based monitoring techniques have inherent limitations to efficiently detect smouldering fires. An attempt was made to explore the potential of electrical resistivity tomography (ERT) as an alternate tool to address the problem. In the experiments an externally powered resistive wire was employed to initiate the smouldering fire inside the test material (wood pellets, wood shavings, wood fines). Time series of ERT that followed the initiation and development of smouldering were recorded using an automated monitoring instrument setup. The actual geometry of the experimental sample container and electrode setup was integrated in the 3D finite element method (FEM) model grid to perform inverse numerical modelling (inversion) and to develop resistivity tomographic images. The study shows a sharp increase in ratio of resistivity (R/Ro ≥ 50 %) in the test material in the region of smouldering hotspot and demonstrates the potential use of ERT technique for the detection of smouldering hotspots in silos and pile storage of organic material such as wood-based fuels, wood waste, coal, municipal solid waste (MSW), recyclables etc. More research is however required for enabling the use of this technique at the practical scale for different storage conditions.


Assuntos
Madeira , Incêndios , Reciclagem/métodos , Tomografia/métodos , Eliminação de Resíduos/métodos , Biocombustíveis/análise
16.
Phys Med Biol ; 69(11)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38648803

RESUMO

Objective.We present the first fully two-dimensional attenuation imaging technique developed for pulse-echo ultrasound systems. Unlike state-of-the-art techniques, which use line-by-line acquisitions, our method uses steered emissions to constrain attenuation values at each location with multiple crossing wave paths, essential to resolve the spatial variations of this tissue property.Approach.At every location, we compute normalized cross-correlations between the beamformed images that are obtained from emissions at different steering angles. We demonstrate that their log-amplitudes provide the changes between attenuation-induced amplitude losses undergone by the different incident waves. This allows us to formulate a linear tomographic problem, which we efficiently solve via a Tikhonov-regularized least-squares approach.Main results.The performance of our tomography technique is first validated in numerical examples and then experimentally demonstrated in custom-made tissue-mimicking phantoms with inclusions of varying size, echogenicity, and attenuation. We show that this technique is particularly good at resolving lateral variations in tissue attenuation and remains accurate in media with varying echogenicity.Significance.Based on a similar principle, this method can be easily combined with computed ultrasound tomography in echo mode for speed-of-sound imaging, paving the way towards a multi-modal ultrasound tomography framework characterizing multiple acoustic tissue properties simultaneously.


Assuntos
Imagens de Fantasmas , Tomografia , Ultrassonografia , Ultrassonografia/métodos , Tomografia/métodos , Processamento de Imagem Assistida por Computador/métodos
17.
Urolithiasis ; 52(1): 65, 2024 Apr 17.
Artigo em Inglês | MEDLINE | ID: mdl-38630281

RESUMO

Extracorporeal shock wave lithotripsy (ESWL) is a safe and efficient treatment option for urinary stone disease. The overall stone-free rate (SFR) varies significantly. This study aimed to assess the influence of stone size, location, stone density, and skin-to-stone distance (SSD), on the outcome of ESWL. We assessed whether pre-treatment non-contrast-enhanced CT scan (NCCT) confers significant advantages compared to kidney-ureter-bladder film (KUB) only. We reviewed the medical records of 307 cases (165 men, 142 women) with renal and ureteral stones treated consecutively at our institution with ESWL between 2020 and 2023. 44 of these underwent a NCCT. The outcome of ESWL was defined in two ways: visible stone fragmentation on KUB, and the need for further treatment. Overall success of fragmentation was 85% (261 patients). 61% of patients (n = 184) didn't need any further treatment. Stone size and location correlated significantly with treatment outcomes regarding the need for further treatment (p = 0.004) and stone fragmentation (p = 0.016), respectively. Unlike mean SSD (p = 0.462), the mean attenuation value (MAV) significantly correlated with the need for retreatment (p = 0.016). MAV seems to be a better predictor of treatment success (AUC of the ROC curve: 0.729), compared to stone size (AUC: 0.613). The difference between groups (with and without NCCT) in both treatment outcomes did not reach statistical significance. During decision-making, information regarding SSD and MAV can be useful in more dubious scenarios. However, it appears that their inclusion doesn't provide substantial advantages when compared to relying solely on KUB.


Assuntos
Litotripsia , Cálculos Ureterais , Masculino , Humanos , Feminino , Estudos Retrospectivos , Cálculos Ureterais/diagnóstico por imagem , Cálculos Ureterais/terapia , Rim , Computadores , Tomografia
18.
Eur Respir J ; 63(4)2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38636970

RESUMO

BACKGROUND: Up to 50% of those attending for low-dose computed tomography screening for lung cancer continue to smoke and co-delivery of smoking cessation services alongside screening may maximise clinical benefit. Here we present data from an opt-out co-located smoking cessation service delivered alongside the Yorkshire Lung Screening Trial (YLST). METHODS: Eligible YLST participants were offered an immediate consultation with a smoking cessation practitioner (SCP) at their screening visit with ongoing smoking cessation support over subsequent weeks. RESULTS: Of 2150 eligible participants, 1905 (89%) accepted the offer of an SCP consultation during their initial visit, with 1609 (75%) receiving ongoing smoking cessation support over subsequent weeks. Uptake of ongoing support was not associated with age, ethnicity, deprivation or educational level in multivariable analyses, although men were less likely to engage (adjusted OR (ORadj) 0.71, 95% CI 0.56-0.89). Uptake was higher in those with higher nicotine dependency, motivation to stop smoking and self-efficacy for quitting. Overall, 323 participants self-reported quitting at 4 weeks (15.0% of the eligible population); 266 were validated by exhaled carbon monoxide (12.4%). Multivariable analyses of eligible smokers suggested 4-week quitting was more likely in men (ORadj 1.43, 95% CI 1.11-1.84), those with higher motivation to quit and previous quit attempts, while those with a stronger smoking habit in terms of cigarettes per day were less likely to quit. CONCLUSIONS: There was high uptake for co-located opt-out smoking cessation support across a wide range of participant demographics. Protected funding for integrated smoking cessation services should be considered to maximise programme equity and benefit.


Assuntos
Abandono do Hábito de Fumar , Tabagismo , Masculino , Humanos , Abandono do Hábito de Fumar/métodos , Serviços de Saúde Comunitária , Pulmão , Tomografia
19.
BMC Complement Med Ther ; 24(1): 143, 2024 Apr 04.
Artigo em Inglês | MEDLINE | ID: mdl-38575891

RESUMO

BACKGROUND: This study aimed to determine the therapeutic efficacy of curcumin nanoemulsion (CUR-NE) in mice infected with Echinococcus granulosus sensu stricto protoscoleces. METHODS: Forty-two inbred BALB/c mice were divided into seven groups of six animals each. Six groups were inoculated intra-peritoneally with 1500 viable E. granulosus protoscoleces, followed for six months and used as infected groups. The infected groups were named as: CEI1 to CEI6 accordingly. The 7th group was not inoculated and was named cystic echinococcosis noninfected group (CENI7). CEI1 and CEI2 groups received 40 mg/kg/day and 20 mg/kg/day curcumin nanoemulsion (CUR-NE), respectively. CEI3 received nanoemulsion without curcumin (NE-no CUR), CEI4 received curcumin suspension (CUR-S) 40 mg/kg/day, CEI5 received albendazole 150 mg/kg/day and CEI6 received sterile phosphate-buffered saline (PBS). CENI7 group received CUR-NE 40 mg/kg/day. Drugs administration was started after six months post-inoculations of protoscoleces and continued for 60 days in all groups. The secondary CE cyst area was evaluated by computed tomography (CT) scan for each mouse before treatment and on the days 30 and 60 post-treatment. The CT scan measurement results were compared before and after treatment. After the euthanasia of the mice on the 60th day, the cyst area was also measured after autopsy and, the histopathological changes of the secondary cysts for each group were observed. The therapeutic efficacy of CUR-NE in infected groups was evaluated by two methods: CT scan and autopsied cyst measurements. RESULTS: Septal calcification in three groups of infected mice (CEI1, CEI2, and CEI4) was revealed by CT scan. The therapeutic efficacy of CUR-NE 40 mg/kg/day (CEI1 group) was 24.6 ± 26.89% by CT scan measurement and 55.16 ± 32.37% by autopsied cysts measurements. The extensive destructive effects of CUR-NE 40 mg/kg/day (CEI1 group) on the wall layers of secondary CE cysts were confirmed by histopathology. CONCLUSION: The current study demonstrated a significant therapeutic effect of CUR-NE (40 mg/kg/day) on secondary CE cysts in BALB/c mice. An apparent septal calcification of several cysts revealed by CT scan and the destructive effect on CE cysts observed in histopathology are two critical key factors that suggest curcumin nanoemulsion could be a potential treatment for cystic echinococcosis.


Assuntos
Curcumina , Cistos , Equinococose , Animais , Camundongos , Curcumina/farmacologia , Curcumina/uso terapêutico , Camundongos Endogâmicos BALB C , Equinococose/diagnóstico por imagem , Equinococose/tratamento farmacológico , Tomografia
20.
Respir Res ; 25(1): 179, 2024 Apr 25.
Artigo em Inglês | MEDLINE | ID: mdl-38664685

RESUMO

BACKGROUND: Prolonged weaning from mechanical ventilation is associated with poor clinical outcome. Therefore, choosing the right moment for weaning and extubation is essential. Electrical Impedance Tomography (EIT) is a promising innovative lung monitoring technique, but its role in supporting weaning decisions is yet uncertain. We aimed to evaluate physiological trends during a T-piece spontaneous breathing trail (SBT) as measured with EIT and the relation between EIT parameters and SBT success or failure. METHODS: This is an observational study in which twenty-four adult patients receiving mechanical ventilation performed an SBT. EIT monitoring was performed around the SBT. Multiple EIT parameters including the end-expiratory lung impedance (EELI), delta Tidal Impedance (ΔZ), Global Inhomogeneity index (GI), Rapid Shallow Breathing Index (RSBIEIT), Respiratory Rate (RREIT) and Minute Ventilation (MVEIT) were computed on a breath-by-breath basis from stable tidal breathing periods. RESULTS: EELI values dropped after the start of the SBT (p < 0.001) and did not recover to baseline after restarting mechanical ventilation. The ΔZ dropped (p < 0.001) but restored to baseline within seconds after restarting mechanical ventilation. Five patients failed the SBT, the GI (p = 0.01) and transcutaneous CO2 (p < 0.001) values significantly increased during the SBT in patients who failed the SBT compared to patients with a successful SBT. CONCLUSION: EIT has the potential to assess changes in ventilation distribution and quantify the inhomogeneity of the lungs during the SBT. High lung inhomogeneity was found during SBT failure. Insight into physiological trends for the individual patient can be obtained with EIT during weaning from mechanical ventilation, but its role in predicting weaning failure requires further study.


Assuntos
Impedância Elétrica , Tomografia , Desmame do Respirador , Humanos , Desmame do Respirador/métodos , Masculino , Feminino , Pessoa de Meia-Idade , Idoso , Tomografia/métodos , Monitorização Fisiológica/métodos , Adulto , Respiração Artificial/métodos , Respiração , Idoso de 80 Anos ou mais , Pulmão/fisiopatologia , Pulmão/diagnóstico por imagem , Pulmão/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA