Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 2.748
Filtrar
1.
J Nanobiotechnology ; 22(1): 239, 2024 May 12.
Artigo em Inglês | MEDLINE | ID: mdl-38735951

RESUMO

Widespread distribution of porcine epidemic diarrhea virus (PEDV) has led to catastrophic losses to the global pig farming industry. As a result, there is an urgent need for rapid, sensitive and accurate tests for PEDV to enable timely and effective interventions. In the present study, we develop and validate a floating gate carbon nanotubes field-effect transistor (FG CNT-FET)-based portable immunosensor for rapid identification of PEDV in a sensitive and accurate manner. To improve the affinity, a unique PEDV spike protein-specific monoclonal antibody is prepared by purification, and subsequently modified on FG CNT-FET sensor to recognize PEDV. The developed FET biosensor enables highly sensitive detection (LoD: 8.1 fg/mL and 100.14 TCID50/mL for recombinant spike proteins and PEDV, respectively), as well as satisfactory specificity. Notably, an integrated portable platform consisting of a pluggable FG CNT-FET chip and a portable device can discriminate PEDV positive from negative samples and even identify PEDV and porcine deltacoronavirus within 1 min with 100% accuracy. The portable sensing platform offers the capability to quickly, sensitively and accurately identify PEDV, which further points to a possibility of point of care (POC) applications of large-scale surveillance in pig breeding facilities.


Assuntos
Técnicas Biossensoriais , Nanotubos de Carbono , Vírus da Diarreia Epidêmica Suína , Vírus da Diarreia Epidêmica Suína/isolamento & purificação , Animais , Suínos , Técnicas Biossensoriais/métodos , Técnicas Biossensoriais/instrumentação , Nanotubos de Carbono/química , Limite de Detecção , Imunoensaio/métodos , Imunoensaio/instrumentação , Anticorpos Monoclonais/imunologia , Transistores Eletrônicos , Doenças dos Suínos/diagnóstico , Doenças dos Suínos/virologia , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , Infecções por Coronavirus/diagnóstico , Infecções por Coronavirus/veterinária , Infecções por Coronavirus/virologia , Anticorpos Antivirais/imunologia , Desenho de Equipamento
2.
J Phys Chem A ; 128(19): 3926-3933, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38712508

RESUMO

Nanopore field-effect transistor (NP-FET) devices hold great promise as sensitive single-molecule sensors, which provide CMOS-based on-chip readout and are also highly amenable to parallelization. A plethora of applications will therefore benefit from NP-FET technology, such as large-scale molecular analysis (e.g., proteomics). Due to its potential for parallelization, the NP-FET looks particularly well-suited for the high-throughput readout of DNA-based barcodes. However, to date, no study exists that unravels the bit-rate capabilities of NP-FET devices. In this paper, we design DNA-based barcodes by labeling a piece of double-stranded DNA with dumbbell-like DNA structures. We explore the impact of both the size of the dumbbells and their spacing on achievable bit-rates. The conformational fluctuations of this DNA-origami, as observed by molecular dynamics (MD) simulation, are accounted for when selecting label sizes. An experimentally informed 3D continuum nanofluidic-nanoelectronic device model subsequently predicts both the ionic current and FET signals. We present a barcode design for a conceptually generic NP-FET, with a 14 nm diameter pore, operating in conditions corresponding to experiments. By adjusting the spacing between the labels to half the length of the pore, we show that a bit-rate of 78 kbit·s-1 is achievable. This lies well beyond the state-of-the-art of ≈40 kbit·s-1, with significant headroom for further optimizations. We also highlight the advantages of NP-FET readout based on the larger signal size and sinusoidal signal shape.


Assuntos
DNA , Simulação de Dinâmica Molecular , Nanoporos , Transistores Eletrônicos , DNA/química
3.
Anal Chem ; 96(19): 7577-7584, 2024 May 14.
Artigo em Inglês | MEDLINE | ID: mdl-38696338

RESUMO

Owing to the separation of field-effect transistor (FET) devices from sensing environments, extended-gate FET (EGFET) biosensor features high stability and low cost. Herein, a highly sensitive EGFET biosensor based on a GaN micropillar array and polycrystalline layer (GMP) was fabricated, which was prepared by using simple one-step low-temperature MOCVD growth. In order to improve the sensitivity and detection limit of EGFET biosensor, the surface area and the electrical conductivity of extended-gate electrode can be increased by the micropillar array and the polycrystalline layer, respectively. The designed GMP-EGFET biosensor was modified with l-cysteine and applied for Hg2+ detection with a low limit of detection (LOD) of 1 ng/L, a high sensitivity of -16.3 mV/lg(µg/L) and a wide linear range (1 ng/L-24.5 µg/L). In addition, the detection of Hg2+ in human urine was realized with an LOD of 10 ng/L, which was more than 30 times lower than that of reported sensors. To our knowledge, it is the first time that GMP was used as extended-gate of EGFET biosensor.


Assuntos
Técnicas Biossensoriais , Limite de Detecção , Mercúrio , Humanos , Mercúrio/urina , Mercúrio/análise , Transistores Eletrônicos , Gálio/química , Eletrodos
4.
Biosens Bioelectron ; 258: 116336, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38692222

RESUMO

As pure antipodes may differ in biological interactions, pharmacology, and toxicity, discrimination of enantiomers is important in the pharmaceutical and agrochemical industries. Two major challenges in enantiomer determination are transducing and amplifying the distinct chiral-recognition signals. In this study, a light-sensitive organic photoelectrochemical transistor (OPECT) with homochiral character is developed for enantiomer discrimination. Demonstrated with the discrimination of glucose enantiomers, the photoelectrochemically active gate electrode is prepared by integrating Au nanoparticles (AuNPs) and a chiral Cu(II)-metal-organic framework (c-CuMOF) onto TiO2 nanotube arrays (TNT). The captured glucose enantiomers are oxidized to hydrogen peroxide (H2O2) by the oxidase-mimicking AuNPs-loaded c-CuMOF. Based on the confinement effect of the mesopocket structure of the c-CuMOF and the remarkable charge transfer ability of the 1D nanotubular architecture, variations in H2O2 yield are translated into significant changes in OPECT drain currents (ID) by inducing a catalytic precipitation reaction. Variations in ID confer a sensitive discrimination of glucose enantiomers with a limit of detection (LOD) of 0.07 µM for L-Glu and 0.05 µM for D-Glu. This enantiomer-driven gate electrode response strategy not only provides a new route for enantiomer identification, but also helps to understand the origin of the high stereoselectivity in living systems.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , Glucose , Ouro , Peróxido de Hidrogênio , Limite de Detecção , Nanopartículas Metálicas , Estruturas Metalorgânicas , Estruturas Metalorgânicas/química , Técnicas Biossensoriais/instrumentação , Ouro/química , Técnicas Eletroquímicas/instrumentação , Estereoisomerismo , Nanopartículas Metálicas/química , Glucose/análise , Glucose/química , Glucose/isolamento & purificação , Peróxido de Hidrogênio/química , Peróxido de Hidrogênio/análise , Titânio/química , Transistores Eletrônicos , Cobre/química , Luz , Monossacarídeos/análise , Monossacarídeos/química , Nanotubos/química
5.
Nanotechnology ; 35(32)2024 May 20.
Artigo em Inglês | MEDLINE | ID: mdl-38692268

RESUMO

An ion detection device that combines a DNA-origami nanopore and a field-effect transistor (FET) was designed and modeled to determine sensitivity of the nanodevice to the local cellular environment. Such devices could be integrated into a live cell, creating an abiotic-biotic interface integrated with semiconductor electronics. A continuum model is used to describe the behavior of ions in an electrolyte solution. The drift-diffusion equations are employed to model the ion distribution, taking into account the electric fields and concentration gradients. This was matched to the results from electric double layer theory to verify applicability of the model to a bio-sensing environment. The FET device combined with the nanopore is shown to have high sensitivity to ion concentration and nanopore geometry, with the electrical double layer behavior governing the device characteristics. A logarithmic relationship was found between ion concentration and a single FET current, generating up to 200 nA of current difference with a small applied bias.


Assuntos
DNA , Íons , Nanoporos , Transistores Eletrônicos , DNA/análise , DNA/química , Nanotecnologia/instrumentação , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos
6.
Biosens Bioelectron ; 258: 116368, 2024 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-38744114

RESUMO

Biosensing with biological field-effect transistors (bioFETs) is a promising technology toward specific, label-free, and multiplexed sensing in ultra-small samples. The current study employs the field-effect meta-nano-channel biosensor (MNC biosensor) for the detection of the enzyme N-acetyl-beta-D-glucosaminidase (NAGase), a biomarker for milk cow infections. The measurements are performed in a 0.5 µL drops of 3% commercial milk spiked with NAGase concentrations in the range of 30.3 aM-3.03 µM (Note that there is no background NAGase concentration in commercial milk). Specific and label-free sensing of NAGase is demonstrated with a limit-of-detection of 30.3 aM, a dynamic range of 11 orders of magnitude and with excellent linearity and sensitivity. Additional two important research outcomes are reported. First, the ionic strength of the examined milk is ∼120 mM which implies a bulk Debye screening length <1 nm. Conventionally, a 1 nm Debye length excludes the possibility of sensing with a recognition layer composed of surface bound anti-NAGase antibodies with a size of ∼10 nm. This apparent contradiction is removed considering the ample literature reporting antibody adsorption in a predominantly surface tilted configuration (side-on, flat-on, etc.). Secondly, milk contains a non-specific background protein concentration of 33 mg/ml, in addition to considerable amounts of micron-size heterogeneous fat structures. The reported sensing was performed without the customarily exercised surface blocking and without washing of the non-specific signal. This suggests that the role of non-specific adsorption to the BioFET sensing signal needs to be further evaluated. Control measurements are reported.


Assuntos
Acetilglucosaminidase , Técnicas Biossensoriais , Limite de Detecção , Leite , Técnicas Biossensoriais/métodos , Leite/química , Animais , Bovinos , Acetilglucosaminidase/análise , Concentração Osmolar , Transistores Eletrônicos , Desenho de Equipamento
7.
Chem Commun (Camb) ; 60(34): 4581-4584, 2024 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-38576349

RESUMO

A study of an integrated OPECT biosensor gate and the EC color-changing region on the same chip was carried out, achieving sensitive detection through bioetching-induced signal changes. Enzymatic bioetching enables specific alkaline phosphatase (ALP) detection by catalyzing the production of CdS, which modulates the channel current and generates a visual signal.


Assuntos
Fosfatase Alcalina , Técnicas Biossensoriais , Técnicas Eletroquímicas , Fosfatase Alcalina/metabolismo , Fosfatase Alcalina/análise , Transistores Eletrônicos , Compostos de Cádmio/química , Sulfetos/química , Processos Fotoquímicos
8.
Nanotechnology ; 35(29)2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38604130

RESUMO

Numerous efforts have been undertaken to mitigate the Debye screening effect of FET biosensors for achieving higher sensitivity. There are few reports that show sub-femtomolar detection of biomolecules by FET mechanisms but they either suffer from significant background noise or lack robust control. In this aspect, deformed/crumpled graphene has been recently deployed by other researchers for various biomolecule detection like DNA, COVID-19 spike proteins and immunity markers like IL-6 at sub-femtomolar levels. However, the chemical vapor deposition (CVD) approach for graphene fabrication suffers from various surface contamination while the transfer process induces structural defects. In this paper, an alternative fabrication methodology has been proposed where glass substrate has been initially texturized by wet chemical etching through the sacrificial layer of synthesized silver nanoparticles, obtained by annealing of thin silver films leading to solid state dewetting. Graphene has been subsequently deposited by thermal reduction technique from graphene oxide solution. The resulting deformed graphene structure exhibits higher sensor response towards glial fibrillary acidic protein (GFAP) detection with respect to flat graphene owing to the combined effect of reduced Debye screening and higher surface area for receptor immobilization. Additionally, another interesting aspect of the reported work lies in the biomolecule capture by dielectrophoretic (DEP) transport on the crests of the convex surfaces of graphene in a coplanar gated topology structure which has resulted in 10 aM and 28 aM detection limits of GFAP in buffer and undiluted plasma respectively, within 15 min of application of analyte. The detection limit in buffer is almost four decades lower than that documented for GFAP using biosensors which is is expected to pave way for advancing graphene FET based sensors towards ultrasensitive point-of-care diagnosis of GFAP, a biomarker for traumatic brain injury.


Assuntos
Técnicas Biossensoriais , Proteína Glial Fibrilar Ácida , Grafite , Humanos , Técnicas Biossensoriais/métodos , Eletroforese/métodos , Vidro/química , Proteína Glial Fibrilar Ácida/análise , Grafite/química , Limite de Detecção , Nanopartículas Metálicas/química , Prata/química , Transistores Eletrônicos
9.
Nature ; 629(8011): 335-340, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38658759

RESUMO

Flexible and large-area electronics rely on thin-film transistors (TFTs) to make displays1-3, large-area image sensors4-6, microprocessors7-11, wearable healthcare patches12-15, digital microfluidics16,17 and more. Although silicon-based complementary metal-oxide-semiconductor (CMOS) chips are manufactured using several dies on a single wafer and the multi-project wafer concept enables the aggregation of various CMOS chip designs within the same die, TFT fabrication is currently lacking a fully verified, universal design approach. This increases the cost and complexity of manufacturing TFT-based flexible electronics, slowing down their integration into more mature applications and limiting the design complexity achievable by foundries. Here we show a stable and high-yield TFT platform for the fabless manufacturing of two mainstream TFT technologies, wafer-based amorphous indium-gallium-zinc oxide and panel-based low-temperature polycrystalline silicon, two key TFT technologies applicable to flexible substrates. We have designed the iconic 6502 microprocessor in both technologies as a use case to demonstrate and expand the multi-project wafer approach. Enabling the foundry model for TFTs, as an analogy of silicon CMOS technologies, can accelerate the growth and development of applications and technologies based on these devices.


Assuntos
Silício , Transistores Eletrônicos , Silício/química , Eletrônica/instrumentação , Índio/química , Gálio/química , Óxido de Zinco/química , Desenho de Equipamento , Semicondutores
10.
Nat Commun ; 15(1): 3454, 2024 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658551

RESUMO

In artificial nervous systems, conductivity changes indicate synaptic weight updates, but they provide limited information compared to living organisms. We present the pioneering design and production of an electrochromic neuromorphic transistor employing color updates to represent synaptic weight for in-sensor computing. Here, we engineer a specialized mechanism for adaptively regulating ion doping through an ion-exchange membrane, enabling precise control over color-coded synaptic weight, an unprecedented achievement. The electrochromic neuromorphic transistor not only enhances electrochromatic capabilities for hardware coding but also establishes a visualized pattern-recognition network. Integrating the electrochromic neuromorphic transistor with an artificial whisker, we simulate a bionic reflex system inspired by the longicorn beetle, achieving real-time visualization of signal flow within the reflex arc in response to environmental stimuli. This research holds promise in extending the biomimetic coding paradigm and advancing the development of bio-hybrid interfaces, particularly in incorporating color-based expressions.


Assuntos
Besouros , Animais , Besouros/fisiologia , Transistores Eletrônicos , Biomimética/métodos , Biomimética/instrumentação , Redes Neurais de Computação , Cor , Vibrissas/fisiologia , Biônica/métodos , Biônica/instrumentação , Sinapses/fisiologia
11.
Biosensors (Basel) ; 14(4)2024 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-38667200

RESUMO

Organic electrochemical transistors appear as an alternative for relatively low-cost, easy-to-operate biosensors due to their intrinsic amplification. Herein, we present the fabrication, characterization, and validation of an immuno-detection system based on commercial sensors using gold electrodes where no additional surface treatment is performed on the gate electrode. The steady-state response of these sensors has been studied by analyzing different semiconductor organic channels in order to optimize the biomolecular detection process and its the application to monitoring human IgG levels due to SARS-CoV-2 infections. Detection levels of up to tens of µgmL-1 with sensitivities up to 13.75% [µg/mL]-1, concentration ranges of medical relevance in seroprevalence studies, have been achieved.


Assuntos
Técnicas Biossensoriais , COVID-19 , Técnicas Eletroquímicas , Imunoglobulina G , SARS-CoV-2 , Transistores Eletrônicos , Humanos , Técnicas Biossensoriais/instrumentação , Imunoglobulina G/sangue , SARS-CoV-2/imunologia , SARS-CoV-2/isolamento & purificação , COVID-19/diagnóstico , COVID-19/sangue , Ouro/química , Eletrodos , Anticorpos Antivirais , Imunoensaio
12.
PLoS One ; 19(4): e0301980, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38669276

RESUMO

This research introduces a new designing process and analysis of an innovative Silicon-on-Insulator Metal-Semiconductor Field-Effect (SOI MESFET) structure that demonstrates improved DC and RF characteristics. The design incorporates several modifications to control and reduce the electric field concentration within the channel. These modifications include relocating the transistor channel to sub-regions near the source and drain, adjusting the position of the gate electrode closer to the source, introducing an aluminum layer beneath the channel, and integrating an oxide layer adjacent to the gate. The results show that the AlOx-MESFET configuration exhibits a remarkable increase of 128% in breakdown voltage and 156% in peak power. Furthermore, due to enhanced conductivity and a significant reduction in gate-drain capacitance, there is a notable improvement of 53% in the cut-off frequency and a 28% increase in the maximum oscillation frequency. Additionally, the current gain experiences a boost of 15%. The improved breakdown voltage and peak power make it suitable for applications requiring robust performance under high voltage and power conditions. The increased maximum oscillation frequency and cut-off frequency make it ideal for high-frequency applications where fast signal processing is crucial. Moreover, the enhanced current gain ensures efficient amplification of signals. The introduced SOI MESFET structure with its modifications offers significant improvements in various performance metrics. It provides high oscillation frequency, better breakdown voltage and good cut-off frequency, and current gain compared to the traditional designs. These enhancements make it a highly desirable choice for applications that demand high-frequency and high-power capabilities.


Assuntos
Desenho de Equipamento , Silício , Silício/química , Semicondutores , Transistores Eletrônicos , Condutividade Elétrica , Fontes de Energia Elétrica , Metais/química
13.
Biosens Bioelectron ; 257: 116171, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38636317

RESUMO

The COVID-19 pandemic has highlighted the need for rapid and sensitive detection of SARS-CoV-2. Here, we report an ultrasensitive SARS-CoV-2 immunosensor by integration of an AlGaN/GaN high-electron-mobility transistor (HEMT) and anti-SARS-CoV-2 spike protein antibody. The AlGaN/GaN HEMT immunosensor has demonstrated the capability to detect SARS-CoV-2 spike proteins at an impressively low concentration of 10-22 M. The sensor was also applied to pseudoviruses and SARS-CoV-2 ΔN virions that display the Spike proteins with a single virion particle sensitivity. These features validate the potential of AlGaN/GaN HEMT biosensors for point of care tests targeting SARS-CoV-2. This research not only provides the first HEMT biosensing platform for ultrasensitive and label-free detection of SARS-CoV-2.


Assuntos
Técnicas Biossensoriais , COVID-19 , Gálio , SARS-CoV-2 , Glicoproteína da Espícula de Coronavírus , Transistores Eletrônicos , Vírion , SARS-CoV-2/isolamento & purificação , SARS-CoV-2/imunologia , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Glicoproteína da Espícula de Coronavírus/imunologia , Glicoproteína da Espícula de Coronavírus/análise , Humanos , COVID-19/diagnóstico , COVID-19/virologia , Gálio/química , Vírion/isolamento & purificação , Vírion/química , Limite de Detecção , Compostos de Alumínio/química , Desenho de Equipamento , Imunoensaio/instrumentação , Imunoensaio/métodos , Anticorpos Imobilizados/química , Anticorpos Antivirais
14.
Biosens Bioelectron ; 257: 116333, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38669846

RESUMO

Foodborne diseases caused by Salmonella enterica (S. enterica) and Staphylococcus aureus (S. aureus) significantly impact public health, underscoring the imperative for highly sensitive, rapid, and accurate detection technologies to ensure food safety and prevent human diseases. Nanomaterials hold great promise in the development of high-sensitivity transistor biosensors. In this work, field-effect transistor (FET) comprising high-purity carbon nanotubes (CNTs) were fabricated and modified with corresponding nucleic acid aptamers for the high-affinity and selective capture of S. enterica and S. aureus. The aptamer-functionalized CNT-FET biosensor demonstrated ultra-sensitive and rapid detection of these foodborne pathogens. Experimental results indicated that the biosensor could detect S. enterica at a limit of detection (LOD) as low as 1 CFU in PBS buffer, and S. aureus at an LOD of 1.2 CFUs, achieving single-cell level detection accuracy with exceptional specificity. The biosensor exhibited a rapid response time, completing single detections within 200 s. Even in the presence of interference from six complex food matrices, the biosensor maintained its ultra-sensitive (3.1 CFUs) and rapid response (within 200 s) characteristics for both pathogens. The developed aptamer-functionalized CNT-FET biosensor demonstrates a capability for low-cost, ultra-sensitive, label-free, and rapid detection of low-abundance S. enterica and S. aureus in both buffer solutions and complex environments. This innovation holds significant potential for applying this detection technology to on-site rapid testing scenarios, offering a promising solution to the pressing need for efficient and reliable pathogen monitoring in various settings.


Assuntos
Aptâmeros de Nucleotídeos , Técnicas Biossensoriais , Limite de Detecção , Nanotubos de Carbono , Salmonella enterica , Staphylococcus aureus , Transistores Eletrônicos , Nanotubos de Carbono/química , Salmonella enterica/isolamento & purificação , Staphylococcus aureus/isolamento & purificação , Técnicas Biossensoriais/instrumentação , Aptâmeros de Nucleotídeos/química , Humanos , Microbiologia de Alimentos/instrumentação , Análise de Célula Única/instrumentação
15.
Biosens Bioelectron ; 257: 116311, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38677018

RESUMO

One of the serious challenges facing modern point-of-care (PoC) molecular diagnostic platforms relate to reliable detection of low concentration biomarkers such as nucleic acids or proteins in biological samples. Non-specific analyte-receptor interactions due to competitive binding in the presence of abundant molecules, inefficient mass transport and very low number of analyte molecules in sample volume, in general pose critical hurdles for successful implementation of such PoC platforms for clinical use. Focusing on these specific challenges, this work reports a unique PoC biosensor that combines the advantages of nanoscale biologically-sensitive field-effect transistor arrays (BioFET-arrays) realized in a wafer-scale top-down nanofabrication as high sensitivity electrical transducers with that of sophisticated molecular programs (MPs) customized for selective recognition of analyte miRNAs and amplification resulting in an overall augmentation of signal transduction strategy. The MPs realize a programmable universal molecular amplifier (PUMA) in fluidic matrix on chip and provide a biomarker-triggered exponential release of small nucleic acid sequences easily detected by receptor-modified BioFETs. A common miRNA biomarker LET7a was selected for successful demonstration of this novel biosensor, achieving limit of detection (LoD) down to 10 fM and wide dynamic ranges (10 pM-10 nM) in complex physiological solutions. As the determination of biomarker concentration is implemented by following the electrical signal related to analyte-triggered PUMA in time-domain instead of measuring the threshold shifts of BioFETs, and circumvents direct hybridization of biomarkers at transducer surface, this new strategy also allows for multiple usage (>3 times) of the biosensor platform suggesting exceptional cost-effectiveness for practical use.


Assuntos
Técnicas Biossensoriais , Desenho de Equipamento , Limite de Detecção , MicroRNAs , Técnicas Biossensoriais/instrumentação , MicroRNAs/análise , Humanos , Biomarcadores , Transistores Eletrônicos , Sistemas Automatizados de Assistência Junto ao Leito , Dispositivos Lab-On-A-Chip
16.
Biosens Bioelectron ; 257: 116346, 2024 Aug 01.
Artigo em Inglês | MEDLINE | ID: mdl-38688230

RESUMO

The field of organic photoelectrochemical transistor (OPECT) is newly emerged, with increasing efforts attempting to utilize its properties in biological sensing. Advanced materials with new physicochemical properties have proven important to this end. Herein, we report a metal-organic polymers-gated OPECT biosensing exemplified by CuⅠ-arylacetylide polymers (CuAs)-modulated poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) channel. Both the photoelectrochemical properties and gating capability of CuAs are explored and optimized for high-efficacy photogating. Morever, based on its inherent structure, the specific reaction between CuAs and sulfur ions (S2-) is revealed and S2--mediated microRNA-21 detection is realized by linking with nucleic acid amplification and alkaline phosphatase catalytic chemistry. This work introduces metal-organic polymers as gating materials for OPECT biosensing.


Assuntos
Técnicas Biossensoriais , Técnicas Eletroquímicas , MicroRNAs , Polímeros , Poliestirenos , Transistores Eletrônicos , Técnicas Biossensoriais/instrumentação , Polímeros/química , Poliestirenos/química , MicroRNAs/análise , MicroRNAs/sangue , Cobre/química , Humanos , Fosfatase Alcalina/química , Limite de Detecção , Tiofenos
17.
J Hazard Mater ; 470: 134175, 2024 May 15.
Artigo em Inglês | MEDLINE | ID: mdl-38574662

RESUMO

Emerging organic photoelectrochemical transistors (OPECTs) with inherent amplification capabilities, good biocompatibility and even self-powered operation have emerged as a promising detection tool, however, they are still not widely studied for pollutant detection. In this paper, a novel OPECT dual-mode aptasensor was constructed for the ultrasensitive detection of di(2-ethylhexyl) phthalate (DEHP). MXene/In2S3/In2O3 Z-scheme heterojunction was used as a light fuel for ion modulation in sensitive gated OPECT biosensing. A transistor system based on poly(3,4-ethylenedioxythiophene):poly(styrene sulfonate) (PEDOT:PSS) converted biological events associated with photosensitive gate achieving nearly a thousand-fold higher current gain at zero bias voltage. This work quantified the target DEHP by aptamer-specific induction of CRISPR-Cas13a trans-cutting activity with target-dependent rolling circle amplification as the signal amplification unit, and incorporated the signal changes strategy of biocatalytic precipitation and TMB color development. Combining OPECT with the auxiliary validation of colorimetry (CM), high sensitivity and accurate detection of DEHP were achieved with a linear range of 0.1 pM to 200 pM and a minimum detection limit of 0.02 pM. This study not only provides a new method for the detection of DEHP, but also offers a promising prospect for the gating and application of the unique OPECT.


Assuntos
Técnicas Biossensoriais , Dietilexilftalato , Técnicas Eletroquímicas , Transistores Eletrônicos , Aptâmeros de Nucleotídeos/química , Técnicas Biossensoriais/métodos , Sistemas CRISPR-Cas , Dietilexilftalato/química , Dietilexilftalato/análise , Técnicas Eletroquímicas/instrumentação , Técnicas Eletroquímicas/métodos , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico , Poliestirenos/química , Tiofenos , Poluentes Químicos da Água/análise
18.
Anal Chem ; 96(17): 6847-6852, 2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38639290

RESUMO

Organic photoelectrochemical transistor (OPECT) has shown substantial potential in the development of next-generation bioanalysis yet is limited by the either-or situation between the photoelectrode types and the channel types. Inspired by the dual-photoelectrode systems, we propose a new architecture of dual-engine OPECT for enhanced signal modulation and its biosensing application. Exemplified by incorporating the CdS/Bi2S3 photoanode and Cu2O photocathode within the gate-source circuit of Ag/AgCl-gated poly(3,4-ethylenedioxythiophene):poly(styrenesulfonate) (PEDOT:PSS) channel, the device shows enhanced modulation capability and larger transconductance (gm) against the single-photoelectrode ones. Moreover, the light irritation upon the device effectively shifts the peak value of gm to zero gate voltage without degradation and generates larger current steps that are advantageous for the sensitive bioanalysis. Based on the as-developed dual-photoelectrode OPECT, target-mediated recycling and etching reactions are designed upon the CdS/Bi2S3, which could result in dual signal amplification and realize the sensitive microRNA-155 biodetection with a linear range from 1 fM to 100 pM and a lower detection limit of 0.12 fM.


Assuntos
Cobre , Técnicas Eletroquímicas , Sulfetos , Tiofenos , Técnicas Eletroquímicas/instrumentação , Cobre/química , Sulfetos/química , Compostos de Cádmio/química , Técnicas Biossensoriais/instrumentação , Bismuto/química , Transistores Eletrônicos , Processos Fotoquímicos , Poliestirenos/química , MicroRNAs/análise , Eletrodos , Polímeros/química
19.
ACS Sens ; 9(4): 1916-1926, 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38501291

RESUMO

Conductive metal-organic frameworks (MOFs) have received increasing attention in recent years and present high application potential as sensing elements in electronic sensors. In this study, flexible field-effect transistor (FET) sensors based on conductive MOF, i.e., Ni3(HHTP)2, have been constructed. This Ni3(HHTP)2 sensor has high sensitivity (detection limit of 56 ppb) as well as superior selectivity for NO2 detection at room temperature, which is demonstrated by accurate gas detection in a mixed gas atmosphere. Moreover, by employing six flexible substrates, i.e., polyimide (PI), tape (PET), facemask, paper cup, tablecloth, and take-out bag (textile), we successfully demonstrate the universality of the flexible sensor construction with conductive MOF as sensing film on various substrates. This study of conductive MOF-based flexible electronic sensors offers a new opportunity for a wide range of sensing applications with wearable and portable electronic devices.


Assuntos
Níquel , Transistores Eletrônicos , Níquel/química , Limite de Detecção , Estruturas Metalorgânicas/química , Dióxido de Nitrogênio/análise , Gases/análise , Gases/química
20.
Enzyme Microb Technol ; 177: 110428, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38547746

RESUMO

The sensing modified electrode was prepared using glucose oxidase immobilized onto vanadium pentoxide xerogel with glass/FTO as support electrode to evaluate the possibility to construct a V2O5/GOx Extended Gate Field Effect Transistor biosensor. Previously, our studies exhibited a sensitivity of V2O5 of 58.1 mV/pH. The use of Nafion® onto V2O5/GOx caused a decrease of mass loss after several cycles compared to the modified electrode without Nafion® during the EQCM and cyclic voltammetrics studies. Electrical characterization of V2O5/GOx demonstrated a tendency to stability after 200 s as a function of applied current. In presence of glucose and in different pH, the current decreased when the glucose concentration increased due to the lower active sites of enzyme. After ten voltammetric cycles, the total charge tends to structural stability. In pH = 5.0, the modified electrode based on V2O5/GOx Extended Gate Field Effect Transistor presented more tendency to sensitivity in different concentration of glucose.


Assuntos
Técnicas Biossensoriais , Eletrodos , Enzimas Imobilizadas , Glucose Oxidase , Glucose , Compostos de Vanádio , Técnicas Biossensoriais/instrumentação , Técnicas Biossensoriais/métodos , Enzimas Imobilizadas/metabolismo , Enzimas Imobilizadas/química , Glucose Oxidase/metabolismo , Glucose Oxidase/química , Glucose/análise , Compostos de Vanádio/química , Transistores Eletrônicos , Concentração de Íons de Hidrogênio , Técnicas Eletroquímicas/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA