1.
Georgian Med News ; (348): 44-46, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38807389

RESUMO

This research aims to characterize efficiency of a flexible ureteroscope that is of single use with regard to surgical time, absence of stone, and complications. From March 2022 to April 2023, the Basrah Urological Centre carried out this anticipated work. After excluding patients with untreated urinary tract infections, excessive blood urea, and ureteral strictures, the study involved ninety-eight patients. All patients were above 20 years of age. Patients were operated on by the same surgeon. This study involved 108 patients in this study composed of 42 (39.8%) men and 65 (60.2%) women. With a standard deviation of 10.9 years, the patient's mean age was 39.2 years. The total stone burden ranged from 6.9 to 14.5 mm, averaging 9.7±2.9 mm. The stone density ranged from 820-1411 HU, averaging 1000.8±279.3 HU. According to the current study, treating renal stones with a single-use flexible ureteroscope is less complicated and more successful.


Assuntos
Cálculos Renais , Litotripsia , Ureteroscópios , Humanos , Feminino , Masculino , Adulto , Cálculos Renais/cirurgia , Cálculos Renais/terapia , Litotripsia/instrumentação , Litotripsia/métodos , Pessoa de Meia-Idade , Equipamentos Descartáveis , Ureteroscopia/instrumentação , Ureteroscopia/métodos , Duração da Cirurgia
2.
Urolithiasis ; 52(1): 78, 2024 May 27.
Artigo em Inglês | MEDLINE | ID: mdl-38801419

RESUMO

This study aims to identify optimal parameters for using Thulium fiber lasers (TFL) in ureteral stone lithotripsy to ensure laser safety and maximize efficacy. Our goal is to improve the outcomes of single-use semi-rigid ureteroscopy for treating stones located in the proximal ureter. A clinically relevant thermal testing device was designed to investigate heating effects during TFL stone fragmentation. The device was utilized to identify safe power thresholds for TFL at various irrigation rates. Three other devices were used to assess varying pulse energy effects on stone fragmentation efficiency, dusting, retropulsion, and depth of tissue vaporization. Comparative experiments in fresh porcine renal units were performed to validate the efficacy and safety of optimal TFL parameters for semi-rigid ureteroscopy in proximal ureteral stone procedures. Our study found that the improved device generated a higher thermal effect. Furthermore, the safe power threshold for laser lithotripsy increased as the irrigation rate was raised. At an irrigation rate of 40 ml/min, it is safe to use an average power of less than 30 watts. Although increasing pulse energy has a progressively lower effect on fragmentation and dust removal efficiency, it did lead to a linear increase in stone displacement and tissue vaporization depth. Thermal testing showed 20 W (53.87 ± 2.67 °C) indicating potential urothelial damage. In our study of laser lithotripsy for proximal ureteral stones, the group treated with 0.3 J pulses had several advantages compared to the 0.8 J group: Fewer large fragments (> 4 mm): 0 vs. 1.67 fragments (1-2.25), p = 0.002, a lower number of collateral tissue injuries: 0.50 (0-1.25) vs. 2.67 (2-4), p = 0.011, and lower stone retropulsion grading: 0.83 (0.75-1) vs. 1.67 (1-2), p = 0.046. There was no significant difference in operating time between the groups (443.33 ± 78.30 s vs. 463.17 ± 75.15 s, p = 0.664). These findings suggest that TFL irradiation generates a greater thermal effect compared to non-irradiated stones. Furthermore, the thermal effect during laser lithotripsy is influenced by both power and irrigation flow rate. Our study suggests that using a power below 15 W with an irrigation flow rate of 20 ml/min is safe. Moreover, a pulse energy of 0.3 J appears to be optimal for achieving the best overall stone fragmentation effect.


Assuntos
Litotripsia a Laser , Túlio , Cálculos Ureterais , Cálculos Ureterais/terapia , Cálculos Ureterais/cirurgia , Litotripsia a Laser/métodos , Litotripsia a Laser/instrumentação , Litotripsia a Laser/efeitos adversos , Animais , Suínos , Lasers de Estado Sólido/uso terapêutico , Ureteroscopia/métodos , Ureteroscopia/instrumentação , Ureteroscopia/efeitos adversos
4.
Sci Rep ; 14(1): 9446, 2024 04 24.
Artigo em Inglês | MEDLINE | ID: mdl-38658694

RESUMO

To validate the feasibility of a fiber-optic pressure sensor-based pressure measurement device for monitoring intrarenal pressure and to analyze the effects of ureteral acess sheath (UAS) type, surgical location, perfusion flow rate, and measurement location on intrarenal pressure (IRP). The measurement deviations and response times to transient pressure changes were compared between a fiber-optic pressure sensing device and a urodynamic device IRP in an in vitro porcine kidney and in a water tank. Finally, pressure measurements were performed in anesthetized female pigs using fiber-optic pressure sensing device with different UAS, different perfusion flow rates, and different surgical positions at different renal calyces and ureteropelvic junctions (UPJ). According to our operation, the result is fiber optic pressure sensing devices are highly accurate and sensitive. Under the same conditions, IRP varied among different renal calyces and UPJ (P < 0.05). IRP was lowest at 50 ml/min and highest at 150 ml/min (P < 0.05). Surgical position had a significant effect on IRP (P < 0.05). 12/14 Fr UAS had a lower IRP than 11/13 Fr UAS. Therefore fiber optic pressure sensing devices are more advantageous for IRP measurements. In ureteroscopy, the type of ureteral sheath, the surgical position, the perfusion flow rate, and the location of the measurement all affect the intrarenal pressure value.


Assuntos
Tecnologia de Fibra Óptica , Rim , Pressão , Ureteroscopia , Animais , Tecnologia de Fibra Óptica/instrumentação , Suínos , Feminino , Rim/fisiologia , Ureteroscopia/instrumentação , Ureteroscopia/métodos , Fibras Ópticas , Urodinâmica
5.
BMC Urol ; 22(1): 24, 2022 Feb 23.
Artigo em Inglês | MEDLINE | ID: mdl-35197025

RESUMO

BACKGROUND: The current study aimed to assess a novel ureteroscopic technique developed for treating upper urinary calculi based on a specially designed lateral decubitus body position that could avoid stone loss by adjusting to the effects of gravity. METHODS: This retrospective study examined patients with upper urinary calculi who were surgically treated from November 2008 to January 2020, using a new body position and a rigid ureteroscope. Clinical outcomes, stone-free rates, operative times and complications were evaluated, and factors that could influence treatment success were determined. RESULTS: In total, 1080 patients were included, and 1145 operations were performed. The maximum calculus diameters were 11.22 ± 5.01 mm. Operative times were 48.60 ± 27.44 min. A total of 1042 cases were successfully treated, with a stone-free rate of 91.00%. Multivariate analysis showed that female sex (OR = 2.135, 95% CI 1.332-3.422, P = 0.002), thin scope standby (OR = 1.643, 95% CI 1.074-2.514, P = 0.022), laser lithotripsy (OR = 5.087, 95% CI 2.400-10.785, P = 0.000) and stone size (OR = 0.946, 95% CI 0.912-0.981, P = 0.003) were independently associated with stone-free outcomes. In total, 2 ureteral perforations, 2 ureteric avulsions and 4 urosepsis cases were observed, but were all cured without sequelae. CONCLUSIONS: Ureteroscopic lithotripsy in the lateral decubitus position is a safe and effective technique for treating upper urinary tract calculi, especially upper ureteral calculi.


Assuntos
Litotripsia/métodos , Cálculos Ureterais/terapia , Ureteroscópios , Ureteroscopia/instrumentação , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Desenho de Equipamento , Feminino , Humanos , Litotripsia/instrumentação , Litotripsia a Laser/métodos , Masculino , Pessoa de Meia-Idade , Posicionamento do Paciente , Postura , Estudos Retrospectivos , Fatores Sexuais , Ureteroscopia/métodos
6.
Urol Clin North Am ; 49(1): 119-128, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34776046

RESUMO

Although percutaneous nephrolithotomy (PCNL) is less morbid than open surgery, it still carries risks of significant complications as well as injury to the renal parenchyma. Flexible ureteroscopic stone removal, although causes no appreciable damage to the renal parenchyma, has limitations, most notably, a lower stone-free rate than PCNL. Advances in our knowledge regarding ureteral physiology combined with technical developments applied to ureteral access sheath deployment and size may well propel retrograde intrarenal surgery to the forefront of kidney stone removal, regardless of stone size or location.


Assuntos
Cálculos Renais/cirurgia , Litotripsia a Laser , Nefrolitotomia Percutânea/efeitos adversos , Nefrolitotomia Percutânea/métodos , Ureteroscopia , Humanos , Ureteroscopia/instrumentação
7.
Urol Int ; 105(11-12): 1039-1045, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34247163

RESUMO

INTRODUCTION: The primary aim of this study is to compare the efficacy and safety of retrograde intrarenal surgery (RIRS) among the children and adults with similar stone burdens and locations. Also, the secondary aim of this study is to identify the factors affecting the stone-free rates (SFRs) of RIRS. METHODS: We retrospectively compared perioperative results, SFRs, and complication rates (CRs) between pediatric (group 1, n: 55) and adult (group 2, n: 220) age groups diagnosed with kidney stones and treated by flexible ureterorenoscopy using the same instruments. Furthermore, multivariate analysis was performed to determine the factors affecting the SFR. RESULTS: A total of 275 patients (pediatric group: 55; adult group: 220) were included in this study. The mean age of pediatric and adult groups was 7.2 ± 5.3 and 43.9 ± 15.1, respectively. The mean stone size was 13.9 ± 6.6 mm in the pediatric group compared to 14.8 ± 6.7 mm in the adult group (p = 0.35). Stone localizations and number were similar. JJ stenting for passive dilatation and use of UAS were higher in the pediatric group (p = 0.002; p = 0.017). However, postoperative double pigtail stenting rate was higher in the adult group (p < 0.001). Total CR was 13.8% and mostly Clavien I-II, and no difference was observed between the 2 groups (p = 0.541). The SFRs between the groups were similar (pediatric group: 81.8%; adult group: 78.2%; p = 0.554). On multivariate analysis, stone size (p < 0.001) and lower calyx stone (p < 0.001) were the negative predictive factors for SFR. CONCLUSION: There are small technical differences between pediatric patients and adult patients in our study, but RIRS in children is as safe and efficient as it is in adults.


Assuntos
Nefrolitíase/cirurgia , Ureteroscopia , Urolitíase/cirurgia , Adolescente , Adulto , Fatores Etários , Idoso , Idoso de 80 Anos ou mais , Criança , Pré-Escolar , Feminino , Humanos , Lactente , Masculino , Pessoa de Meia-Idade , Nefrolitíase/diagnóstico por imagem , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Resultado do Tratamento , Ureteroscopia/efeitos adversos , Ureteroscopia/instrumentação , Urolitíase/diagnóstico por imagem , Adulto Jovem
8.
BJU Int ; 128(4): 408-423, 2021 10.
Artigo em Inglês | MEDLINE | ID: mdl-34242475

RESUMO

OBJECTIVES: The objective of this study was to identify, map and review scope-related and user-related parameters used to evaluate the quality of flexible ureterorenoscopes. Thereby identifying key items and variability in grading systems. METHODS: A literature search of four databases (MEDLINE [Ovid], EMBASE [Ovid], Web of Science, Google scholar and the Cochrane Library) was performed according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines encompassing articles published up to August 2020. A total of 2386 articles were screened. RESULTS: A total of 48 articles were included in this systematic scoping review. All studies had a prospective design. Five key items in the assessment of flexible ureterorenoscopy were distinguished: 'Manoeuvrability' (87.5%), 'Optics' (64.6%), 'Irrigation' (56.3%), 'Handling' (39.6%) and 'Durability' (35.4%). After regrouping, every key item could be divided into specific subcategories. However, the quality assessment showed a wide variation in denomination, method of measurement, circumstances of measurement, tools used during measurements, number of measurements performed, number of observers, and units of outcomes. CONCLUSION: The research field regarding quality assessment of ureterorenoscopes is heterogeneous. In this systematic scoping review we identified five key parameters: Manoeuvrability, Optics, Irrigation, Handling and Durability, used to grade flexible ureterorenoscopes. However, within these categories we found a wide variety in terms of method of measurements. A standardised, uniform grading tool is required to assess and compare the quality of flexible ureterorenoscopes in the future.


Assuntos
Estudos de Avaliação como Assunto , Ureteroscópios , Ureteroscopia/instrumentação , Humanos
9.
J Urol ; 206(5): 1232-1239, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34251886

RESUMO

PURPOSE: Residual fragments following retrograde intrarenal surgery can lead to future stone episodes. The lower pole of the kidney presents a unique challenge as it is the most difficult location for retrograde intrarenal surgery. We investigated a modified patient position to increase stone-free rate by analyzing presence of residual fragments. We randomized patients into standard position and the T-Tilt position (15° Trendelenburg and 15° airplane away from the surgical side kidney). MATERIALS AND METHODS: In this prospective, randomized study, patients were randomized into the standard or T-Tilt position. Demographics, comorbidities and operative parameters were collected. Stone-free rate was determined with renal ultrasound and x-ray at 1-month followup. Postoperative complications were recorded up to 1 month. Variables were compared using Kruskal-Wallis test for continuous variables and chi-square test for categorical variables. RESULTS: A total of 138 patients were analyzed: 75 standard patients and 63 T-Tilt patients. The groups had similar patient and stone factors. The most common stone position was the lower pole (68.0% standard, 74.6% T-Tilt). Stone-free rates were significantly different: standard position was 76.7% and T-Tilt position was 92.1% (p=0.015). Stone-free rates for isolated lower pole stones were significantly different as well: standard position was 68.2% and T-Tilt position was 95.6% (p <0.001). Clavien-Dindo scores did not differ significantly (p=0.262). CONCLUSIONS: The T-Tilt patient position was associated with higher stone-free rates. It is an atraumatic, cost-effective technique. These results suggest that modifying patient positioning during retrograde intrarenal surgery improves stone-free rates.


Assuntos
Nefrolitíase/cirurgia , Posicionamento do Paciente/métodos , Ureteroscopia/métodos , Idoso , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Complicações Pós-Operatórias , Estudos Prospectivos , Resultado do Tratamento , Ureteroscopia/instrumentação
10.
BJU Int ; 128(6): 734-743, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-34028166

RESUMO

OBJECTIVES: To compare the oncological outcomes of patients with upper tract urothelial carcinoma (UTUC) undergoing kidney-sparing surgery (KSS) with fibre-optic (FO) vs digital (D) ureteroscopy (URS). To evaluate the oncological impact of image-enhancement technologies such as narrow-band imaging (NBI) and Image1-S in patients with UTUC. PATIENTS AND METHODS: The Clinical Research Office of the Endourology Society (CROES)-UTUC registry is an international, multicentre, cohort study prospectively collecting data on patients with UTUC. Patients undergoing flexible FO- or D-URS for diagnostic or diagnostic and treatment purposes were included. Differences between groups in terms of overall survival (OS) and disease-free survival (DFS) were evaluated. RESULTS: The CROES registry included 2380 patients from 101 centres and 37 countries, of whom 401 patients underwent URS (FO-URS 186 and D-URS 215). FO-URS were performed more frequently for diagnostic purposes, while D-URS was peformed when a combined diagnostic and treatment strategy was planned. Intra- and postoperative complications did not differ between the groups. The 5-year OS and DFS rates were 91.5% and 66.4%, respectively. The mean OS was 42 months for patients receiving FO-URS and 39 months for those undergoing D-URS (P = 0.9); the mean DFS was 28 months in the FO-URS group and 21 months in the D-URS group (P < 0.001). In patients who received URS with treatment purposes, there were no differences in OS (P = 0.9) and DFS (P = 0.7). NBI and Image1-S technologies did not improve OS or DFS over D-URS. CONCLUSIONS: D-URS did not provide any oncological advantage over FO-URS. Similarly, no differences in terms of OS and DFS were found when image-enhancement technologies were compared to D-URS. These findings underline the importance of surgeon skills and experience, and reinforce the need for the centralisation of UTUC care.


Assuntos
Carcinoma de Células de Transição/diagnóstico por imagem , Carcinoma de Células de Transição/cirurgia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/cirurgia , Neoplasias Ureterais/diagnóstico por imagem , Neoplasias Ureterais/cirurgia , Ureteroscopia/métodos , Idoso , Intervalo Livre de Doença , Feminino , Humanos , Aumento da Imagem , Rim/cirurgia , Masculino , Pessoa de Meia-Idade , Imagem de Banda Estreita , Tratamentos com Preservação do Órgão , Sistema de Registros , Taxa de Sobrevida , Ureteroscopia/instrumentação
11.
Sci Rep ; 11(1): 10337, 2021 05 14.
Artigo em Inglês | MEDLINE | ID: mdl-33990648

RESUMO

Although many ureteral stents are commercially available, the actuality of encrustation is yet to be elucidated in humans. This study compared the Tria Ureteral Stent with PercuShield and the Polaris Ultra Ureteral Stent with HydroPlus Coating for short-term encrustation formation. Eighty-four patients, who required ureteral stent placement after ureteroscopy, were randomized into two stent groups. After stent removal on postoperative day 14, the encrustation volume on the stent surface was measured by micro-computed tomography. The primary outcome was the inner luminal encrustation volume. Secondary outcomes were encrustation volume on the outer or total surfaces and occurrence of adverse events. Clinical factors related to encrustation were also assessed as a post-hoc analysis. Finally, of the 82 patients analyzed, 75 (91.5%) had encrustation in the inner lumen of the stent. The difference in median inner encrustation volume between the Tria and Polaris Ultra stents was comparable (0.56 vs. 0.37 mm3, P = 0.183). There was no difference observed in the encrustation volume on the outer/total surfaces and stent-related adverse events. In both ureteral stents, the shaft body showed significant inner luminal encrustation compared to the proximal or distal loop (all, P < 0.05). Dyslipidemia (P = 0.027), elevated urine pH (P = 0.046), and crystalluria (P = 0.010) were associated with encrustation formation. The Tria and Polaris Ultra stents had similar efficacy for preventing encrustation in the short-term. Further studies are required to compare their long-term patency.


Assuntos
Stents/efeitos adversos , Ureteroscopia/instrumentação , Urolitíase/cirurgia , Idoso , Remoção de Dispositivo/estatística & dados numéricos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Stents/estatística & dados numéricos , Ureter/cirurgia , Ureteroscopia/efeitos adversos , Microtomografia por Raio-X/estatística & dados numéricos
12.
World J Urol ; 39(10): 3957-3962, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-33970313

RESUMO

PURPOSE: Single-use disposable digital flexible ureterorenoscope has become an attractive option to reusable scope with many advantages. Currently available single-use digital fURS have outer shaft diameter above 9 Fr which requires large access sheath insertion and sometimes double J stent placement. Recently, 7.5 Fr single-use digital fURS is introduced in market by Pusen. Objective of this study is to compare two Pusen single-use scopes in the clinical setting: 7.5 Fr Uscope PU3033A and 9.5 Fr Uscope PU3022A. METHODS: 30 patients, having renal stones < 2 cm, planned for RIRS were prospectively randomized to two groups: group 1 had 15 patients in which 7.5 Fr Uscope PU3033A and group 2 had 15 patients in which 9.5 Fr Uscope PU3022A was used. The various pre-operative, intra-operative, and post-operative parameters at 1 month along with complications were evaluated for both the scopes by a single surgical team. RESULTS: Pre-operative parameters including stone characteristics were comparable in both the groups. Three patients in group 2 needed ureteric dilatation prior to 11/13 access sheath insertion, while 10/12 Fr access sheath was placed in all patients in group 1 without manipulation (p = 0.06). Intra-operative vision was comparable in both scopes with an empty working channel and with laser. Hazy vision while lasing in two and one patient in group 1 and group 2, respectively (p = 0.54). In group 1, one had fever and UTI, while in group 2, one had fever post-operatively. CONCLUSION: 7.5 Fr Uscope PU3033A could be introduced with smaller access sheath. The vision, deflection, maneuverability is comparable to 9.5 Fr Uscope PU3022a.


Assuntos
Cálculos Renais/cirurgia , Complicações Pós-Operatórias/epidemiologia , Ureteroscópios , Ureteroscopia/instrumentação , Adulto , Desenho de Equipamento , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Estudos Prospectivos , Resultado do Tratamento , Ureteroscopia/efeitos adversos
13.
Comput Math Methods Med ; 2021: 6668415, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33815566

RESUMO

PURPOSE: Relieving obstruction and protecting renal function are the main therapeutic purposes of obstructive uropathy which often involve surgical treatment, and the ureter catheter is one of the surgical instruments commonly used in surgery. We aimed to explore the innovative use of a ureter catheter in the surgery of obstructive uropathy. METHODS: We used a ureteral catheter to innovate the surgical procedure of the most common causes of obstructive uropathy: ureteral calculi and stricture, establishing an internal circulation system (ICS), proposing a three-step dilatation method, and reviewing their effects on patients. Furthermore, we introduced a simple real-time intrapelvic pressure measurement device to monitor intrarenal pressure during operation. RESULTS: Postoperative laboratory examination showed that blood CRP, leukocyte neutrophil level, changes in the hemoglobin, urine occult blood, and positive rate of urine culture in the ICS group are significantly lower than those in the control group, corresponding to a lower incidence of bleeding and infection-related complications clinically. A three-month follow-up revealed 1/3 rate of ureteral stricture in the ICS group comparing to the control. We applied the three-step dilatation in patients with severe stenosis in which the balloon could not pass; the overall effective rate was 90.9%. The pressure of the renal pelvis was displayed on the monitor in real time. The surgeon could estimate the degree of filling of the renal pelvis and adjust the intake volume through the data. CONCLUSION: The innovative application of ureteral catheters in the operation of obstructive uropathy can realize the real-time monitor of intraoperative renal pelvis pressure, reduce the incidence of lithotripsy postoperative complications, and expand the indications of balloon dilatation in ureteral stricture, which has certain clinical significance.


Assuntos
Obstrução Ureteral/cirurgia , Ureteroscopia/instrumentação , Cateteres Urinários , Biologia Computacional , Dilatação/efeitos adversos , Dilatação/instrumentação , Feminino , Humanos , Invenções/estatística & dados numéricos , Litotripsia/efeitos adversos , Litotripsia/instrumentação , Litotripsia/métodos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Tomografia Computadorizada por Raios X , Ureteroscopia/efeitos adversos , Ureteroscopia/métodos , Urolitíase/diagnóstico por imagem , Urolitíase/cirurgia
14.
Arch Ital Urol Androl ; 93(1): 26-30, 2021 Mar 18.
Artigo em Inglês | MEDLINE | ID: mdl-33754605

RESUMO

INTRODUCTION: In the last years due to miniaturization of endoscopic instruments and percutaneous surgery, endourology has become very popular in paediatric urinary stone managment. We reported our single-centre experience in retrograde endoscopic procedures in children. Results and complications of URS/RIRS are discussed. MATERIALS AND METHODS: We retrospectively reviewed our experience in patients ≤ 16 years old affected by urinary stones who underwent URS/RIRS procedures performed by two surgeons with expertise in endourology. A total of 30 renal Units (RUs) underwent endoscopic procedures (URS, RIRS or both). Surgical complications according to the ClavienDindo's classification and stone-free rate were evaluated at 3 months follow-up. Success of URS was defined as stone-free status after single procedure while RIRS success rate was considered as presence of residual stone fragments smaller than 4 mm at first procedure. RESULTS: The mean age of our patients was 8 years, range 2- 16 years. A total of 30 renal units (RUs) underwent 40 endourological procedures (23 URS and 17 RIRS; 10 children underwent both procedures at the same time). 17/30 (56.6%) RUs were pre-stented before surgery. The stone-free status was achieved in 23/30 renal units treated, with a 76.6% success rate. The remaining 7 patients had residual stones greater than 4 mm and underwent further treatments. After a second surgery the stone-free rate turned out to be 93.3% (28/30 renal units). CONCLUSIONS: Rigid and flexible ureteroscopy (URS/RIRS) is a reliable technique for treatment of < 2 cm urinary stones in paediatric age group. It shows low rate of major complications and promising results in terms of stone-free rate.


Assuntos
Cálculos Renais/cirurgia , Ureteroscópios , Ureteroscopia/instrumentação , Adolescente , Criança , Pré-Escolar , Desenho de Equipamento , Feminino , Humanos , Itália , Masculino , Estudos Retrospectivos , Urolitíase
15.
Int J Med Sci ; 18(4): 1075-1081, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33456366

RESUMO

Catheter-related bladder discomfort (CRBD) associated with intraoperative urinary catheterization is a distressing symptom during recovery from anesthesia. Anticholinergics have been used to manage CRBD. Chlorpheniramine maleate (CPM) is a first-generation antihistamine, which also has anticholinergic effects. This study was undertaken to evaluate the efficacy of CPM in preventing CRBD. Seventy-six adults (19-65 years old) with American Society of Anesthesiologists physical status I, II, or III of either sex, undergoing elective ureteroscopic stone removal under general anesthesia were randomized into one of two groups (each n = 38). Group C (control) received a placebo, and group CPM received 8 mg of intravenous CPM before the induction of anesthesia. CRBD was assessed upon arrival in the post-anesthetic care unit at 0, 1, 2, and 6 h. The severity of CRBD was graded as none, mild, moderate, and severe. Tramadol was administered when the severity of CRBD was more than moderate. The incidence rate and overall severity of CRBD did not differ between the groups at any of the time points (р > 0.05). The incidence of moderate CRBD was higher in group C than in group CPM only at 0 h (26.3% vs. 5.3%, р = 0.025). However, fewer patients in the CPM group required rescue tramadol to relieve CRBD after surgery (31.6% vs. 60.5%, р = 0.011). CPM administration before the induction of anesthesia had little effect on the incidence and severity of CRBD after surgery, but it reduced the administration of tramadol required to control CRBD postoperatively.


Assuntos
Clorfeniramina/administração & dosagem , Antagonistas Muscarínicos/administração & dosagem , Dor Pós-Operatória/epidemiologia , Ureteroscopia/efeitos adversos , Cateterismo Urinário/efeitos adversos , Urolitíase/cirurgia , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Medição da Dor , Dor Pós-Operatória/diagnóstico , Dor Pós-Operatória/etiologia , Dor Pós-Operatória/prevenção & controle , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Ureteroscopia/instrumentação , Ureteroscopia/métodos , Bexiga Urinária/efeitos dos fármacos , Cateterismo Urinário/instrumentação , Cateterismo Urinário/métodos , Cateteres Urinários/efeitos adversos , Adulto Jovem
16.
Ren Fail ; 43(1): 264-272, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33491554

RESUMO

PURPOSE: To compare perioperative outcomes and long-term renal function changes between prior stenting (PS) and not prior stenting (NPS) before flexible ureteroscopy lithotripsy (f-URS) for solitary kidney patients. METHODS: Solitary kidney patients with 10-30 mm renal stones were enrolled in this historical control study. Perioperative parameters and complications were compared. Stone-free was defined as the absence of any residual stones on a CT scan. Renal function changes were evaluated by estimated glomerular filtration rate (eGFR) and adjusted for body surface area. A decrease in the eGFR over 20% was identified as 'deterioration' in renal function. The follow-up period was at least 6 months. Logistic regression was used to identify risk factors of renal function deterioration. RESULTS: Of the 76 patients included, 40 cases experienced prior stenting before f-URS. The average stone diameter was 16.8 ± 4.7 mm, ranging from 10.0 to 28.4 mm. Initial SFR was 85.0 and 83.3% in the PS and NPS groups, respectively (p = 0.842), while SFR after the second procedure was 97.5 and 94.4% (p = 0.926). Seven PS and 5 NPS patients developed complications (p = 0.666). At the postoperative 6 months, seven patients showed a deteriorated renal function. Surgical time in minutes was identified as a risk factor for renal function deterioration after the operation (OR = 1.061, 95% CI: 1.015-1.109, p = 0.009, per minute). CONCLUSION: It appears that one-stage f-URS without PS could be feasible for 10-30 mm renal stones in solitary kidney patients, and less surgical time might be beneficial to protect renal function.


Assuntos
Cálculos Renais/terapia , Litotripsia/efeitos adversos , Complicações Pós-Operatórias/epidemiologia , Rim Único/complicações , Ureteroscopia/efeitos adversos , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos de Viabilidade , Feminino , Taxa de Filtração Glomerular/fisiologia , Humanos , Cálculos Renais/complicações , Litotripsia/instrumentação , Litotripsia/métodos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/fisiopatologia , Estudos Retrospectivos , Fatores de Risco , Rim Único/fisiopatologia , Stents/efeitos adversos , Resultado do Tratamento , Ureteroscópios/efeitos adversos , Ureteroscopia/instrumentação , Ureteroscopia/métodos
17.
World J Urol ; 39(4): 1257-1262, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32556675

RESUMO

OBJECTIVES: To investigate the effect of different laser power settings on intra-renal temperature (IRT) under different irrigation conditions during flexible ureteroscopy (FURS) in a live-anesthetized porcine model. METHODS: Following ethics approval, 2 female pigs weighing ~ 28 kg were used. Under general anesthesia, a percutaneous access was obtained to fix a K-type thermocouple inside the pelvi-calyceal system for real-time recording of IRT during FURS without UAS, UAS-10/12, UAS-12/14, and UAS-14/16F. A high-power holmium laser was used and the IRT was recorded during laser activation for up to 60 s at a laser power of 20 W, 40 W, and 60 W under gravity irrigation and manual pump irrigation. RESULTS: Under gravity irrigation, FURS without UAS was associated with hazardous IRT at a laser power as low as 20 W for as short as 20 s of laser activation. The IRT was rendered borderline when UAS was used. This UAS buffering effect disappeared with the use of higher laser-power settings (40 W and 60 W) with the maximal IRT exceeding 60 °C. Moreover, laser activation at 60 W was associated with very rapid increase in IRT within few seconds. Under pump irrigation, laser activation at the highest power setting (60 W) for 60 s was associated with a safe IRT, even without the use of UAS. The maximal IRT was below 45 °C. CONCLUSION: The use of high-power Ho:YAG laser carries potentially harmful thermal effect when used under gravity irrigation, even when large-diameter UAS is used. High-power settings (> 40 W) require high irrigation flow. The use of UAS is advisable to reduce the IRT and balance any intra-renal pressure increase.


Assuntos
Temperatura Alta , Irrigação Terapêutica , Ureteroscópios , Ureteroscopia/instrumentação , Ureteroscopia/métodos , Animais , Desenho de Equipamento , Feminino , Rim , Suínos
19.
Urolithiasis ; 49(3): 239-245, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33005998

RESUMO

To test in-vitro and in-vivo the Flexor® Vue™ deflecting endoscopic system (FVDES) as a new technology able to improve the removal of residual intrarenal fragments.This is an observational prospective "proof of concept" study performed in patients with renal calculi treated with flexible ureteroscopy and Ho:YAG laser lithotripsy (f-URS) in Humanitas Research Hospital (Rozzano, Italy). We assessed feasibility, efficacy and safety of FVDES as an in-vivo tool for removing residual fragments after f-URS. The stone-free rate (SFR) at 30 days post-operatively was evaluated using CT. An in-vitro model was developed to evaluate the FVDES when used for this purpose.Eleven patients (M/F ratio: 7/4, mean age 63.5 ± 8.3) were treated. The stones were located in the lower calyces and the renal pelvis in 3 and 8 patients, respectively. Mean stone size was 18 ± 3.2 mm. The procedure with FVDES was feasible and effective in all the patients. Mean operative time was 82 ± 13.7 min and median hospitalization was of 1.5 days. The SFR after 90 days was 81% (9/11). We reported no relevant complications (Clavien-Dindo > 2); one patient had fever and was treated with antibiotics. The experimental in-vitro model demonstrated the efficacy of FVDES, allowing the removal of about 90% of fragments.Our study showed that FVDES is effective when used as a tool for retrieval of residual fragments at the end of f-URS. This technology could ensure a complete cleaning of the intrarenal collecting system and represent a safe alternative to basketing.


Assuntos
Cálculos Renais/cirurgia , Lasers de Estado Sólido/uso terapêutico , Litotripsia a Laser/métodos , Ureteroscópios/efeitos adversos , Ureteroscopia/instrumentação , Idoso , Estudos de Viabilidade , Feminino , Humanos , Cálculos Renais/diagnóstico , Cálices Renais/anatomia & histologia , Cálices Renais/cirurgia , Tempo de Internação/estatística & dados numéricos , Litotripsia a Laser/efeitos adversos , Litotripsia a Laser/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Modelos Anatômicos , Duração da Cirurgia , Estudo de Prova de Conceito , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento , Ureteroscopia/efeitos adversos , Ureteroscopia/estatística & dados numéricos
20.
World J Urol ; 39(6): 2169-2175, 2021 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-33025141

RESUMO

OBJECTIVES: A recently introduced device (LithoVue Empower™ or LE, Boston Scientifics, USA) allows the surgeon to directly control the stone-retrieving basket without the need of an assistant during flexible ureteroscopy. We aimed to evaluate the stone-retrieval performance of this device. METHODS: We used a bench-training model for flexible ureteroscopy, the Key-box (K-Box®, Porgès-Coloplast, France), to compare the LE configured with a 1.9F stone-retrieval tipless basket (ZeroTip™, Boston Scientific, USA) and a traditional assistant-maneuvered 1.9F stone-retrieval tipless basket. Seven experienced endo-urologists and seven residents-in-training retrieved a fake stone from three different renal cavities of the K-Box with increasing access complexity first with the traditional basket and then with the LE device. We recorded retrieval time and all the operators filled in the NASA Task Load Index (TLI) for the self-evaluation of their performance. We then compared the use of LE in terms of retrieval time, failure rates, and NASA-TLI scores. RESULTS: Stone retrieval times and failure rates were similar according to the retrieval technique, although residents had non-statistically significant shorter times with the LE. NASA-TLI scores revealed lower frustration (p = 0.03) when LE was used by experienced urologists as compared to the traditional basketing. When stratifying the analyses according to surgical experience, fully trained urologists performed faster stone retrieval and showed lower effort scores than residents-in-training (p < 0.05). CONCLUSIONS: The individually controlled retrieval system is an effective device assisting stone retrieval and does not necessitate specific training among experienced endo-urologists. Young residents might benefit from LE during their learning curve.


Assuntos
Cálculos Renais/cirurgia , Modelos Anatômicos , Treinamento por Simulação , Ureteroscopia/educação , Ureteroscopia/métodos , Humanos , Ureteroscopia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA