1.
Angew Chem Int Ed Engl ; 60(44): 23756-23762, 2021 10 25.
Artigo em Inglês | MEDLINE | ID: mdl-34448329

RESUMO

The longevity and reusability of N95-grade filtering facepiece respirators (N95 FFRs) are limited by consecutive donning and disinfection treatments. Herein, we developed stable N97 nanofibrous respirators based on chemically modified surface to enable remarkable filtration characteristics via polarity driven interaction. This was achieved by a thin-film coated polyacrylonitrile nanofibrous membrane (TFPNM), giving an overall long-lasting filtration performance with high quality factor at 0.42 Pa-1 (filtration efficiency: over 97 %; pressure drop: around 10 Pa), which is higher than that of the commercial N95 FFRs (0.10-0.41 Pa-1 ) tested with a flow rate of 5 L min-1 and the 0.26 µm NaCl aerosol. A coxsackie B4 virus filtration test demonstrated that TFPNM also had strong virus capture capacity of 97.67 %. As compared with N95 FFRs, the TFPNM was more resistant to a wider variety of disinfection protocols, and the overall filtration characteristics remained N97 standard.


Assuntos
Enterovirus Humano B/metabolismo , Nanofibras/química , Ventiladores Mecânicos/virologia
2.
Antimicrob Resist Infect Control ; 10(1): 82, 2021 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-34044893

RESUMO

Aerosolization may occur during reprocessing of medical devices. With the current coronavirus disease 2019 pandemic, it is important to understand the necessity of using respirators in the cleaning area of the sterile processing department. To evaluate the presence of severe acute respiratory syndrome coronavirus (SARS-CoV-2) in the air of the sterile processing department during the reprocessing of contaminated medical devices. Air and surface samples were collected from the sterile processing department of two teaching tertiary hospitals during the reprocessing of respiratory equipment used in patients diagnosed with coronavirus disease 2019 and from intensive care units during treatment of these patients. SARS-CoV-2 was detected only in 1 air sample before the beginning of decontamination process. Viable severe acute respiratory syndrome coronavirus 2 RNA was not detected in any sample collected from around symptomatic patients or in sterile processing department samples. The cleaning of respiratory equipment does not cause aerosolization of SARS-CoV-2. We believe that the use of medical masks is sufficient while reprocessing medical devices during the coronavirus disease 2019 pandemic.


Assuntos
Aerossóis , Descontaminação , Reutilização de Equipamento , Equipamento de Proteção Individual/virologia , SARS-CoV-2/isolamento & purificação , Microbiologia do Ar , Estudos Transversais , Equipamentos e Provisões Hospitalares/virologia , RNA Viral/isolamento & purificação , Centros de Atenção Terciária , Ventiladores Mecânicos/virologia
3.
J Microbiol Immunol Infect ; 54(1): 81-84, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32425995

RESUMO

Herein, we report that nosocomial infection of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) may be mitigated by using surgical masks and closed looped ventilation for both non-critical and critical patients. These preventive measures resulted in no viral contamination of surfaces in negative pressure environments.


Assuntos
COVID-19/prevenção & controle , Fômites/virologia , Unidades de Terapia Intensiva , Máscaras , Isoladores de Pacientes , Coronavírus Relacionado à Síndrome Respiratória Aguda Grave/isolamento & purificação , Ventiladores Mecânicos/virologia , Idoso , Idoso de 80 Anos ou mais , COVID-19/transmissão , Contaminação de Equipamentos , Feminino , Unidades Hospitalares , Humanos , Masculino
4.
Int J Infect Dis ; 104: 320-328, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33359951

RESUMO

OBJECTIVES: The coronavirus disease 2019 pandemic increased global demand for personal protective equipment (PPE) and resulted in shortages. The study evaluated the re-use of surgical masks and respirators by analysing their performance and safety before and after reprocessing using the following methods: oven, thermal drying, autoclave, and hydrogen peroxide plasma vapour. METHODS: In total, 45 surgical masks and 69 respirators were decontaminated. Visual integrity, air permeability, burst resistance, pressure differential and particulate filtration efficiency of new and decontaminated surgical masks and respirators were evaluated. In addition, 14 used respirators were analysed after work shifts before and after decontamination using reverse transcription polymerase chain reaction (RT-PCR) and viral culturing. Finally, reprocessed respirators were evaluated by users in terms of functionality and comfort. RESULTS: Oven decontamination (75 °C for 45 min) was found to be the simplest decontamination method. Physical and filtration assays indicated that all reprocessing methods were safe after one cycle. Oven decontamination maintained the characteristics of surgical masks and respirators for at least five reprocessing cycles. Viral RNA was detected by RT-PCR in two of the 14 used respirators. Four respirators submitted to viral culture were PCR-negative and culture-negative. Reprocessed respirators used in work shifts were evaluated positively by users, even after three decontamination cycles. CONCLUSION: Oven decontamination is a safe method for reprocessing surgical masks and respirators for at least five cycles, and is feasible in the hospital setting.


Assuntos
COVID-19/prevenção & controle , Descontaminação/métodos , Máscaras/virologia , Pandemias , Equipamento de Proteção Individual/virologia , SARS-CoV-2/isolamento & purificação , Ventiladores Mecânicos/virologia , COVID-19/epidemiologia , COVID-19/virologia , Reutilização de Equipamento , Hospitais , Temperatura Alta , Humanos , Peróxido de Hidrogênio/farmacologia , SARS-CoV-2/genética
5.
J Hosp Infect ; 108: 113-119, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-33157170

RESUMO

BACKGROUND: The coronavirus disease 2019 pandemic has caused problems with respirator supplies. Re-use may minimize the impact of the shortage, but requires the availability of an efficient and safe decontamination method. AIM: To determine whether low-temperature-steam-2%-formaldehyde (LTSF) sterilization is effective, preserves the properties of filtering facepiece (FFP) respirators and allows safe re-use. METHODS: Fourteen unused FFP2, FFP3 and N95 respirator models were subjected to two cycles of decontamination cycles. After the second cycle, each model was inspected visually and accumulated residual formaldehyde levels were analysed according to EN 14180. After one and two decontamination cycles, the fit factor (FF) of each model was tested, and penetration tests with sodium chloride aerosols were performed on five models. FINDINGS: Decontamination physically altered three of the 14 models. All of the residual formaldehyde values were below the permissible threshold. Irregular decreases and increases in FF were observed after each decontamination cycle. In the sodium chloride aerosol penetration test, three models obtained equivalent or superior results to those of the FFP classification with which they were marketed, both at baseline and after one and two cycles of decontamination, and two models had lower filtering capacity. CONCLUSION: One and two decontamination cycles using LTSF did not alter the structure of most (11/14) respirators tested, and did not degrade the fit or filtration capacity of any of the analysed respirators. The residual formaldehyde levels complied with EN 14180. This reprocessing method could be used in times of shortage of personal protective equipment.


Assuntos
Descontaminação/métodos , Formaldeído/farmacologia , Dispositivos de Proteção Respiratória/virologia , Esterilização/métodos , Adulto , Aerossóis/efeitos adversos , COVID-19/diagnóstico , COVID-19/epidemiologia , COVID-19/prevenção & controle , COVID-19/virologia , Reutilização de Equipamento , Formaldeído/análise , Humanos , Masculino , Máscaras/tendências , Máscaras/virologia , Equipamento de Proteção Individual/provisão & distribuição , Dispositivos de Proteção Respiratória/provisão & distribuição , SARS-CoV-2/genética , Cloreto de Sódio/análise , Vapor/efeitos adversos , Ventiladores Mecânicos/provisão & distribuição , Ventiladores Mecânicos/virologia
6.
Int J Infect Dis ; 100: 224-229, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32891736

RESUMO

OBJECTIVES: There are currently no studies that have examined whether one dosage can be uniformly applied to different respirator types to effectively decontaminate SARS-CoV-2 on N95 filtering facepiece respirators (FFRs). Health care workers have been using this disinfection method during the pandemic. Our objective was to determine the effect of UVC on SARS-CoV-2 inoculated N95 respirators and whether this was respirator material/model type dependent. METHODS: Four different locations (facepiece and strap) on five different N95 FFR models (3M 1860, 8210, 8511, 9211; Moldex 1511) were inoculated with a 10 µL drop of SARS-CoV-2 viral stock (8 × 107 TCID50/mL). The outside-facing and wearer-facing surfaces of the respirators were each irradiated with a dose of 1.5 J/cm2 UVC (254 nm). Viable SARS-CoV-2 was quantified by a median tissue culture infectious dose assay (TCID50). RESULTS: UVC delivered using a dose of 1.5 J/cm2, to each side, was an effective method of decontamination for the facepieces of 3M 1860 and Moldex 1511, and for the straps of 3M 8210 and the Moldex 1511. CONCLUSION: This dose is an appropriate decontamination method to facilitate the reuse of respirators for healthcare personnel when applied to specific models/materials. Also, some straps may require additional disinfection to maximize the safety of frontline workers. Implementation of widespread UVC decontamination methods requires careful consideration of model, material type, design, and fit-testing following irradiation.


Assuntos
Descontaminação/métodos , Máscaras/virologia , SARS-CoV-2/fisiologia , SARS-CoV-2/efeitos da radiação , Raios Ultravioleta , Ventiladores Mecânicos/virologia , Desinfecção/métodos , Relação Dose-Resposta à Radiação , Reutilização de Equipamento , Humanos , Pandemias
7.
Am J Infect Control ; 48(12): 1540-1542, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32763347

RESUMO

Bioaerosol samples were collected in an airborne infection isolation room, bathroom, and anteroom of a ventilated patient with coronavirus disease 2019. Twenty-eight samples were negative for severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) nucleic acid, possibly due to the patient being on a closed-circuit ventilator or the efficiency of the air exchanges in the room.


Assuntos
COVID-19/transmissão , RNA Viral/análise , SARS-CoV-2 , Ventiladores Mecânicos/virologia , Aerossóis , Microbiologia do Ar , COVID-19/virologia , Humanos , Posicionamento do Paciente , Quartos de Pacientes , Decúbito Ventral , Respiração Artificial
8.
Photodiagnosis Photodyn Ther ; 31: 101943, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32763473

RESUMO

BACKGROUND: To review the effect of ultraviolet germicidal irradiation (UVGI) as a disinfection method for filtering facepiece respirators (FFRs) to facilitate reuse during COVID-19 pandemic. METHODS: Systematic review of the research concerning UVGI for FFRs disinfection to facilitate reuse (also termed limited reuse) during respiratory infectious diseases where aerosol transmission is considered possible. RESULTS: UVGI is one possible method for respiratory disinfection to facilitate the reuse of dwindling supplies. Appropriate dose UVGI exposition could provide enough energy to effectively decontaminate respiratory viral agents and maintain respirator's integrity for reuse. There was not currently sufficient research evidence on the effect of UVGI to inactivate coronaviruses SARS-CoV-2, and the practical application of UVGI is still unclear. . CONCLUSION: Appropriate dose UVGI exposition could provide enough energy to effectively decontaminate respiratory viral agents and maintain respirator's integrity for reuse. Further evidence concerning UVGI as a decontamination technique specifically for SARS-CoV-2 isneeded.


Assuntos
Infecções por Coronavirus/prevenção & controle , Descontaminação/métodos , Contaminação de Equipamentos/prevenção & controle , Pandemias/prevenção & controle , Fotoquimioterapia/métodos , Pneumonia Viral/prevenção & controle , Terapia Ultravioleta/métodos , Ventiladores Mecânicos/virologia , COVID-19 , Infecções por Coronavirus/epidemiologia , Reutilização de Equipamento/estatística & dados numéricos , Humanos , Controle de Infecções/métodos , Pneumonia Viral/epidemiologia
9.
J Laryngol Otol ; 134(8): 732-734, 2020 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-32605665

RESUMO

BACKGROUND: Robust personal protective equipment is essential in preventing the transmission of coronavirus disease 2019 to head and neck surgeons who are routinely involved in aerosol generating procedures. OBJECTIVE: This paper describes the collective experience, across 3 institutes, of using a reusable half-face respirator in 72 head and neck surgery cases. METHOD: Cost analysis was performed to demonstrate the financial implications of using a reusable respirator compared to single-use filtering facepiece code 3 masks. CONCLUSION: The reusable respirator is a cost-effective alternative to disposable filtering facepiece code 3 respirators. Supplying reusable respirators to individual staff members may increase the likelihood of them having appropriate personal protective equipment during their clinical duties.


Assuntos
Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/transmissão , Reutilização de Equipamento/economia , Pandemias/prevenção & controle , Equipamento de Proteção Individual/economia , Pneumonia Viral/prevenção & controle , Pneumonia Viral/transmissão , Aerossóis , Betacoronavirus/isolamento & purificação , Líquidos Corporais/virologia , COVID-19 , Infecções por Coronavirus/epidemiologia , Infecções por Coronavirus/virologia , Análise Custo-Benefício/métodos , Desenho de Equipamento , Feminino , Humanos , Masculino , Exposição Ocupacional/prevenção & controle , Exposição Ocupacional/estatística & dados numéricos , Otolaringologia/estatística & dados numéricos , Procedimentos Cirúrgicos Otorrinolaringológicos/métodos , Procedimentos Cirúrgicos Otorrinolaringológicos/normas , Equipamento de Proteção Individual/provisão & distribuição , Pneumonia Viral/epidemiologia , Pneumonia Viral/virologia , SARS-CoV-2 , Cirurgiões/estatística & dados numéricos , Ventiladores Mecânicos/efeitos adversos , Ventiladores Mecânicos/virologia
10.
Emerg Infect Dis ; 26(9)2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32491983

RESUMO

The coronavirus pandemic has created worldwide shortages of N95 respirators. We analyzed 4 decontamination methods for effectiveness in deactivating severe acute respiratory syndrome coronavirus 2 virus and effect on respirator function. Our results indicate that N95 respirators can be decontaminated and reused, but the integrity of respirator fit and seal must be maintained.


Assuntos
Betacoronavirus , Infecções por Coronavirus/prevenção & controle , Descontaminação/métodos , Reutilização de Equipamento , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Ventiladores Mecânicos/virologia , COVID-19 , Infecções por Coronavirus/virologia , Humanos , Pneumonia Viral/virologia , SARS-CoV-2
11.
Am J Infect Control ; 48(8): 880-882, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-32479844

RESUMO

BACKGROUND: The need for protective masks greatly exceeds their global supply during the current COVID-19 pandemic. METHODS: We optimized the temperature used in the dry heat pasteurization method to destroy pathogens and decontaminate masks while retaining their filtering capacity. RESULTS: The current study showed that dry heat at both 60°C and 70°C for 1 hour could successfully kill 6 species of respiratory bacteria and one fungi species, and inactivate the H1N1 indicator virus. After being heated at 70°C for 1, 2, and 3 hours, the N95 respirators and surgical face masks showed no changes in their shape and components. The filtering efficiency of bacterial aerosol for N95 respirators were 98%, 98%, and 97% after being heated for 1, 2, and 3 hour, respectively, all of which were over the 95% efficiency required and similar to the value before being heated (99%). The filtering efficiency for surgical face masks was 97%, 97%, and 96% for 1, 2, and 3 hours of heating, respectively, all of which were also similar to the value before being heated (97%). CONCLUSIONS: This method can be used at home and can significantly resolve the current shortage of masks.


Assuntos
Descontaminação/métodos , Máscaras/virologia , Pasteurização/métodos , Dispositivos de Proteção Respiratória/virologia , Betacoronavirus/patogenicidade , COVID-19 , Infecções por Coronavirus/prevenção & controle , Infecções por Coronavirus/virologia , Temperatura Alta , Humanos , Vírus da Influenza A Subtipo H1N1/patogenicidade , Exposição Ocupacional/prevenção & controle , Pandemias/prevenção & controle , Pneumonia Viral/prevenção & controle , Pneumonia Viral/virologia , SARS-CoV-2 , Ventiladores Mecânicos/virologia
14.
Am J Infect Control ; 46(7): e49-e55, 2018 07.
Artigo em Inglês | MEDLINE | ID: mdl-29678452

RESUMO

BACKGROUND: Safe and effective decontamination and reuse of N95 filtering facepiece respirators (FFRs) has the potential to significantly extend FFR holdings, mitigating a potential shortage due to an influenza pandemic or other pandemic events. Ultraviolet germicidal irradiation (UVGI) has been shown to be effective for decontaminating influenza-contaminated FFRs. This study aims to build on past research by evaluating the UVGI decontamination efficiency of influenza-contaminated FFRs in the presence of soiling agents using an optimized UVGI dose. METHODS: Twelve samples each of 15 N95 FFR models were contaminated with H1N1 influenza (facepiece and strap), then covered with a soiling agent-artificial saliva or artificial skin oil. For each soiling agent, 3 contaminated FFRs were treated with 1 J/cm2 UVGI for approximately 1 minute, whereas 3 other contaminated FFRs remained untreated. All contaminated surfaces were cut out and virus extracted. Viable influenza was quantified using a median tissue culture infectious dose assay. RESULTS: Significant reductions (≥3 log) in influenza viability for both soiling conditions were observed on facepieces from 12 of 15 FFR models and straps from 7 of 15 FFR models. CONCLUSIONS: These data suggest that FFR decontamination and reuse using UVGI can be effective. Implementation of a UVGI method will require careful consideration of FFR model, material type, and design.


Assuntos
Descontaminação/métodos , Desinfecção/métodos , Vírus da Influenza A Subtipo H1N1/efeitos da radiação , Influenza Humana/prevenção & controle , Ventiladores Mecânicos/virologia , Reutilização de Equipamento , Humanos , Influenza Humana/virologia , Raios Ultravioleta
15.
Appl Environ Microbiol ; 79(7): 2148-55, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23335770

RESUMO

In the United States, the 2009 pandemic influenza A (H1N1) virus (pH1N1) infected almost 20% of the population and caused >200,000 hospitalizations and >10,000 deaths from April 2009 to April 2010. On 24 April 2009, the CDC posted interim guidance on infection control measures in health care settings explicitly for pH1N1 and recommended using filtering face respirators (FFRs) when in close contact with a suspected- or confirmed-to-be-infected individual, particularly when performing aerosol-generating procedures. The persistence and infectivity of pH1N1 were evaluated on FFRs, specifically N95 respirators, under various conditions of absolute humidity (AH) (4.1 × 10(5) mPa, 6.5 × 10(5) mPa, and 14.6 × 10(5) mPa), sample matrices (2% fetal bovine serum [FBS], 5 mg/ml mucin, and viral medium), and times (4, 12, 24, 48, 72, and 144 h). pH1N1 was distributed onto N95 coupons (3.8 to 4.2 cm(2)) and extracted by a vortex-centrifugation-filtration process, and the ability of the remaining virus to replicate was quantified using an enzyme-linked immunosorbent assay (ELISA) to determine the log10 concentration of the infectious virus per coupon. Overall, pH1N1 remained infectious for 6 days, with an approximately 1-log10 loss of virus concentrations over this time period. Time and AH both affected virus survival. We found significantly higher (P ≤ 0.01) reductions in virus concentrations at time points beyond 24 to 72 h (-0.52-log10 reduction) and 144 h (-0.74) at AHs of 6.5 × 10(5) mPa (-0.53) and 14.6 × 10(5) mPa (-0.47). This research supports discarding respirators after close contact with a person with suspected or confirmed influenza infection due to the virus's demonstrated ability to persist and remain infectious.


Assuntos
Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Viabilidade Microbiana , Ventiladores Mecânicos/virologia , Fatores de Tempo , Estados Unidos
17.
Am J Infect Control ; 39(1): e1-9, 2011 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-21145624

RESUMO

BACKGROUND: A major concern among health care experts is a projected shortage of N95 filtering facepiece respirators (FFRs) during an influenza pandemic. One option for mitigating an FFR shortage is to decontaminate and reuse the devices. Many parameters, including biocidal efficacy, filtration performance, pressure drop, fit, and residual toxicity, must be evaluated to verify the effectiveness of this strategy. The focus of this research effort was on evaluating the ability of microwave-generated steam, warm moist heat, and ultraviolet germicidal irradiation at 254 nm to decontaminate H1N1 influenza virus. METHODS: Six commercially available FFR models were contaminated with H1N1 influenza virus as aerosols or droplets that are representative of human respiratory secretions. A subset of the FFRs was treated with the aforementioned decontamination technologies, whereas the remaining FFRs were used to evaluate the H1N1 challenge applied to the devices. RESULTS: All 3 decontamination technologies provided >4-log reduction of viable H1N1 virus. In 93% of our experiments, the virus was reduced to levels below the limit of detection of the method used. CONCLUSIONS: These data are encouraging and may contribute to the evolution of effective strategies for the decontamination and reuse of FFRs.


Assuntos
Aerossóis , Infecção Hospitalar/prevenção & controle , Descontaminação/métodos , Vírus da Influenza A Subtipo H1N1/efeitos dos fármacos , Vírus da Influenza A Subtipo H1N1/isolamento & purificação , Influenza Humana/prevenção & controle , Ventiladores Mecânicos/virologia , Humanos , Influenza Humana/virologia , Viabilidade Microbiana
18.
Am J Infect Control ; 38(1): 9-17, 2010 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-19896238

RESUMO

BACKGROUND: Respiratory protective devices exposed to pathogenic microorganisms present a potential source of transmission of infection during handling. In this study, the efficacy of 4 antimicrobial respirators to decontaminate MS2, a surrogate for pathogenic viruses, was evaluated and compared with control N95 filtering face piece respirators, which did not contain any known antimicrobial components. METHODS: MS2 containing droplet nuclei were generated using a Collison nebulizer and loaded onto respirator coupons at a face velocity of 13.2 cm/seconds for 30 minutes. The coupons were incubated at 2 different temperature and relative humidity (RH) conditions and analyzed for viable MS2 at different time intervals. RESULTS: Results showed that log(10) reduction of MS2 was not statistically significant (P > .05) between the control and antimicrobial respirator coupons, when stored at 22 degrees C and 30% RH up to 20 hours. Coupons from 1 of the 4 antimicrobial respirators showed an average MS2 log(10) reduction of 3.7 at 37 degrees C and 80% RH for 4 hours, which was statistically significant (P < or = .05) compared with coupons from the control respirators. CONCLUSION: Results from this study suggest that MS2 virus decontamination efficacy of antimicrobial respirators is dependent on the antimicrobial agent and storage conditions.


Assuntos
Aerossóis , Desinfetantes/farmacologia , Desinfecção/métodos , Levivirus/efeitos dos fármacos , Viabilidade Microbiana/efeitos dos fármacos , Ventiladores Mecânicos/virologia , Humanos , Umidade , Levivirus/isolamento & purificação , Temperatura , Fatores de Tempo , Ensaio de Placa Viral
19.
Appl Environ Microbiol ; 75(23): 7303-9, 2009 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-19801477

RESUMO

The aim of this study was to develop a test system to evaluate the effectiveness of procedures for decontamination of respirators contaminated with viral droplets. MS2 coliphage was used as a surrogate for pathogenic viruses. A viral droplet test system was constructed, and the size distribution of viral droplets loaded directly onto respirators was characterized using an aerodynamic particle sizer. The sizes ranged from 0.5 to 15 mum, and the sizes of the majority of the droplets were the range from 0.74 to 3.5 mum. The results also showed that the droplet test system generated similar droplet concentrations (particle counts) at different respirator locations. The test system was validated by studying the relative efficiencies of decontamination of sodium hypochlorite (bleach) and UV irradiation with droplets containing MS2 virus on filtering facepiece respirators. It was hypothesized that more potent decontamination treatments would result in corresponding larger decreases in the number of viable viruses recovered from the respirators. Sodium hypochlorite doses of 2.75 to 5.50 mg/liter with a 10-min decontamination period resulted in approximately 3- to 4-log reductions in the level of MS2 coliphage. When higher sodium hypochlorite doses (> or =8.25 mg/liter) were used with the same contact time that was used for the dilute solutions containing 2.75 to 5.50 mg/liter, all MS2 was inactivated. For UV decontamination at a wavelength of 254 nm, an approximately 3-log reduction in the level of MS2 virus was achieved with dose of 4.32 J/cm(2) (3 h of contact time with a UV intensity of 0.4 mW/cm(2)), while with higher doses of UV irradiation (> or =7.20 J/cm(2); UV intensity, 0.4 mW/cm(2); contact times, > or =5 h), all MS2 was inactivated. These findings may lead to development of a standard method to test decontamination of respirators challenged by viral droplets.


Assuntos
Descontaminação/métodos , Descontaminação/normas , Desinfecção/métodos , Desinfecção/normas , Ventiladores Mecânicos/virologia , Desinfetantes/farmacologia , Levivirus/efeitos dos fármacos , Levivirus/isolamento & purificação , Levivirus/efeitos da radiação , Viabilidade Microbiana/efeitos dos fármacos , Viabilidade Microbiana/efeitos da radiação , Hipoclorito de Sódio/farmacologia , Fatores de Tempo , Raios Ultravioleta , Ensaio de Placa Viral
20.
Appl Environ Microbiol ; 75(6): 1500-7, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19139225

RESUMO

A chamber to apply aerosolized virus-containing particles to air-permeable substrates (coupons) was constructed and validated as part of a method to assess the virucidal efficacy of decontamination procedures for filtering facepiece respirators. Coliphage MS2 was used as a surrogate for pathogenic viruses for confirmation of the efficacy of the bioaerosol respirator test system. The distribution of virus applied onto and within the coupons was characterized, and the repeatability of applying a targeted virus load was examined. The average viable virus loaded onto 90 coupons over the course of 5 days was found to be 5.09 +/- 0.19 log(10) PFU/coupon (relative standard deviation, 4%). To determine the ability to differentiate the effectiveness of disinfecting procedures with different levels of performance, sodium hypochlorite and steam treatments were tested in experiments by varying the dose and time, respectively. The role of protective factors was assessed by aerosolizing the virus with various concentrations of the aerosol-generating medium. A sodium hypochlorite (bleach) concentration of 0.6% and steam treatments of 45 s and longer resulted in log reductions (>4 logs) which reached the detection limits for both levels of protective factors. Organic matter (ATCC medium 271) as a protective factor afforded some protection to the virus in the sodium hypochlorite experiments but was not a factor in the steam experiments. The evaluation of the bioaerosol respirator test system demonstrated a repeatable method for applying a targeted viral load onto respirator coupons and provided insight into the properties of aerosols that are of importance to the development of disinfection assays for air-permeable materials.


Assuntos
Descontaminação/métodos , Levivirus/isolamento & purificação , Ventiladores Mecânicos/virologia , Aerossóis , Desinfetantes/farmacologia , Temperatura Alta , Levivirus/efeitos dos fármacos , Levivirus/efeitos da radiação , Viabilidade Microbiana , Hipoclorito de Sódio/farmacologia
SELEÇÃO DE REFERÊNCIAS