Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 8.514
Filtrar
1.
J Vis ; 24(5): 4, 2024 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-38722274

RESUMO

Image differences between the eyes can cause interocular discrepancies in the speed of visual processing. Millisecond-scale differences in visual processing speed can cause dramatic misperceptions of the depth and three-dimensional direction of moving objects. Here, we develop a monocular and binocular continuous target-tracking psychophysics paradigm that can quantify such tiny differences in visual processing speed. Human observers continuously tracked a target undergoing Brownian motion with a range of luminance levels in each eye. Suitable analyses recover the time course of the visuomotor response in each condition, the dependence of visual processing speed on luminance level, and the temporal evolution of processing differences between the eyes. Importantly, using a direct within-observer comparison, we show that continuous target-tracking and traditional forced-choice psychophysical methods provide estimates of interocular delays that agree on average to within a fraction of a millisecond. Thus, visual processing delays are preserved in the movement dynamics of the hand. Finally, we show analytically, and partially confirm experimentally, that differences between the temporal impulse response functions in the two eyes predict how lateral target motion causes misperceptions of motion in depth and associated tracking responses. Because continuous target tracking can accurately recover millisecond-scale differences in visual processing speed and has multiple advantages over traditional psychophysics, it should facilitate the study of temporal processing in the future.


Assuntos
Percepção de Movimento , Psicofísica , Visão Binocular , Humanos , Percepção de Movimento/fisiologia , Psicofísica/métodos , Visão Binocular/fisiologia , Estimulação Luminosa/métodos , Adulto , Percepção de Profundidade/fisiologia , Masculino , Visão Monocular/fisiologia , Feminino , Adulto Jovem , Tempo de Reação/fisiologia
2.
Sci Rep ; 14(1): 11269, 2024 05 17.
Artigo em Inglês | MEDLINE | ID: mdl-38760410

RESUMO

Most binocular vision models assume that the two eyes sum incompletely. However, some facilitatory cortical neurons fire for only one eye, but amplify their firing rates if both eyes are stimulated. These 'binocular gate' neurons closely resemble subthreshold multisensory neurons. Binocular amplification for binocular gate neurons follows a power law, with a compressive exponent. Unexpectedly, this rule also applies to facilitatory true binocular neurons; although driven by either eye, binocular neurons are well modeled as gated amplifiers of their strongest monocular response, if both eyes are stimulated. Psychophysical data follows the same power law as the neural data, with a similar exponent; binocular contrast sensitivity can be modeled as a gated amplification of the more sensitive eye. These results resemble gated amplification phenomena in multisensory integration, and other non-driving modulatory interactions that affect sensory processing. Models of incomplete summation seem unnecessary for V1 facilitatory neurons or contrast sensitivity. However, binocular combination of clearly visible monocular stimuli follows Schrödinger's nonlinear magnitude-weighted average. We find that putatively suppressive binocular neurons closely follow Schrödinger's equation. Similar suppressive multisensory neurons are well documented but seldom studied. Facilitatory binocular neurons and mildly suppressive binocular neurons are likely neural correlates of binocular sensitivity and binocular appearance respectively.


Assuntos
Modelos Neurológicos , Visão Binocular , Visão Binocular/fisiologia , Animais , Neurônios/fisiologia , Humanos , Sensibilidades de Contraste/fisiologia , Estimulação Luminosa , Córtex Visual/fisiologia
3.
Zhonghua Yan Ke Za Zhi ; 60(5): 440-446, 2024 May 11.
Artigo em Chinês | MEDLINE | ID: mdl-38706082

RESUMO

Objective: To explore the differences in clinical characteristics and interocular interactions between patients with anisometropic amblyopia and ametropic amblyopia. Methods: Cross-sectional study. The newly diagnosed anisometropic (the binocular difference in spherical equivalent≥1.00 D) amblyopia patients and ametropic amblyopia patients (aged 4 to 6 years) in Beijing Tongren Hospital from January 2020 to December 2022 were involved. Patients were further categorized by the refractive status after cycloplegia, including hyperopia, myopia, astigmatism, hyperopia with astigmatism, myopia with astigmatism, mild anisometropia and severe anisometropia. Quantitative measurements of best-corrected visual acuity (logMAR), stereoacuity (transformed to log units), perceptual eye position and interocular suppression were performed, and the differences between groups were analyzed. The rank sum test was used for statistical evaluation. Results: The average age of 45 ametropic amblyopia patients (21 males and 24 females) and 84 anisometropic amblyopia patients (48 males and 36 females) was 5.0 (4.0, 5.0) years and 5.0 (4.0, 6.0) years, respectively. The interocular differences in spherical equivalent [2.56 (1.50, 4.19) D vs. 0.25 (0.13, 0.56) D] and best-corrected visual acuity [0.40 (0.18, 0.70) logMAR vs. 0.07 (0.00, 0.12) logMAR] were larger in patients with anisometropic amblyopia than those with ametropic amblyopia. The anisometropic amblyopia patients had worse stereoacuity [2.60 (2.00, 2.90) log arcsec vs. 2.00 (2.00, 2.30) log arcsec] and deeper suppression [20.0% (13.3%, 40.0%) vs. 10.0% (0, 23.3%)], compared with the ametropic amblyopia patients. The differences were all statistically significant (P<0.05). The suppression and stereoacuity between patients with hyperopic anisometropic amblyopia [suppression, 30.0% (17.5%, 50.0%); stereoacuity, 2.90 (2.30, 2.90) log arcsec] and astigmatic anisometropic amblyopia [suppression, 10.0% (0, 20.0%); stereoacuity, 2.00 (2.00, 2.30) log arcsec] were significantly different (P<0.05). The differences of suppression and stereoacuity between patients with severe (binocular difference in spherical equivalent>2.50 D) [suppression, 30.0% (20.0%, 53.3%); stereoacuity, 2.90 (2.57, 2.90) log arcsec] and mild anisometropia [suppression, 20.0% (0, 30.0%); stereoacuity, 2.00 (2.00, 2.90) log arcsec] were also statistically significant (P<0.05). Conclusions: Patients with anisometropic amblyopia have deeper binocular suppression, worse stereoacuity and more severe binocular interaction abnormality than those with ametropic amblyopia. The severity of anisometropia affects the degree of the interaction abnormality.


Assuntos
Ambliopia , Miopia , Visão Binocular , Humanos , Ambliopia/fisiopatologia , Masculino , Feminino , Estudos Transversais , Pré-Escolar , Miopia/complicações , Acuidade Visual , Criança , Astigmatismo , Anisometropia/complicações , Hiperopia/fisiopatologia
4.
Sci Rep ; 14(1): 10183, 2024 05 03.
Artigo em Inglês | MEDLINE | ID: mdl-38702452

RESUMO

The perception of halos and other night vision disturbances is a common complaint in clinical practice. Such visual disturbances must be assessed in order to fully characterize each patient's visual performance, which is particularly relevant when carrying out a range of daily tasks. Visual problems are usually assessed using achromatic stimuli, yet the stimuli encountered in daily life have very different chromaticities. Hence, it is important to assess the effect of the chromaticity of visual stimuli on night vision disturbances. The aim of this work is to study the influence of the chromaticity of different visual stimuli on night vision disturbances by analyzing straylight and visual discrimination under low-light conditions. For that, we assessed the monocular and binocular visual discrimination of 27 subjects under low illumination using the Halo test. The subjects' visual discrimination was assessed after exposure to different visual stimuli: achromatic, red, green, and blue, both at the monitor's maximum luminance and maintaining the same luminance value for the different visual stimuli. Monocular straylight was also measured for an achromatic, red, green, and blue stimuli. The blue stimulus had the greatest effect on halos in both monocular and binocular conditions. Visual discrimination was similar for the red, green, and achromatic stimuli, but worsened at lower luminance. The greatest influence of straylight was observed for the blue stimulus. In addition, visual discrimination correlated with straylight measurements for achromatic stimuli, wherein greater straylight values correlated with an increased perception of halos and other visual disturbances.


Assuntos
Estimulação Luminosa , Humanos , Masculino , Feminino , Adulto , Visão Noturna/fisiologia , Adulto Jovem , Luz , Visão Binocular/fisiologia , Percepção Visual/fisiologia , Percepção de Cores/fisiologia , Transtornos da Visão/fisiopatologia , Iluminação , Pessoa de Meia-Idade
5.
Sci Rep ; 14(1): 10494, 2024 05 07.
Artigo em Inglês | MEDLINE | ID: mdl-38714660

RESUMO

Binocular visual plasticity can be initiated via either bottom-up or top-down mechanisms, but it is unknown if these two forms of adult plasticity can be independently combined. In seven participants with normal binocular vision, sensory eye dominance was assessed using a binocular rivalry task, before and after a period of monocular deprivation and with and without selective attention directed towards one eye. On each trial, participants reported the dominant monocular target and the inter-ocular contrast difference between the stimuli was systematically altered to obtain estimates of ocular dominance. We found that both monocular light- and pattern-deprivation shifted dominance in favour of the deprived eye. However, this shift was completely counteracted if the non-deprived eye's stimulus was selectively attended. These results reveal that shifts in ocular dominance, driven by bottom-up and top-down selection, appear to act independently to regulate the relative contrast gain between the two eyes.


Assuntos
Dominância Ocular , Visão Binocular , Humanos , Visão Binocular/fisiologia , Dominância Ocular/fisiologia , Adulto , Masculino , Feminino , Adulto Jovem , Plasticidade Neuronal/fisiologia , Estimulação Luminosa , Visão Monocular/fisiologia , Percepção Visual/fisiologia , Atenção/fisiologia
6.
PLoS One ; 19(4): e0300222, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38558003

RESUMO

Locomotion has been shown to impact aspects of visual processing in both humans and animal models. In the current study, we assess the impact of locomotion on the dynamics of binocular rivalry. We presented orthogonal gratings, one contrast-modulating at 0.8 Hz (matching average step frequency) and the other at 3.2 Hz, to participants using a virtual reality headset. We compared two conditions: stationary and walking. We continuously monitored participants' foot position using tracking devices to measure the step cycle. During the walking condition, participants viewed the rivaling gratings for 60-second trials while walking on a circular path in a virtual reality environment. During the stationary condition, observers viewed the same stimuli and environment while standing still. The task was to continuously indicate the dominant percept via button press using handheld controllers. We found no significant differences between walking and standing for normalized dominance duration distributions, mean normalized dominance distributions, mean alternation rates, or mean fitted frequencies. Although our findings do not align with prior research highlighting distinctions in normalized dominance distributions between walking and standing, our study contributes unique evidence indicating that alternation rates vary across the step cycle. Specifically, we observed that the number of alternations is at its lowest during toe-off phases and reaches its peak at heel strike. This novel insight enhances our understanding of the dynamic nature of alternation patterns throughout the step cycle.


Assuntos
Realidade Virtual , Visão Binocular , Humanos , Disparidade Visual , Percepção Visual , Caminhada , Estimulação Luminosa
7.
Invest Ophthalmol Vis Sci ; 65(4): 2, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38558094

RESUMO

Purpose: To investigate the relationship between unilateral metamorphopsia, characterized by visual distortions in one eye, and impaired stereopsis. Methods: Utilizing both near and distance measurements through advanced testing systems, including 4K smartphones and an active shutter three-dimensional system, we simulated varying degrees of unilateral metamorphopsia in 30 healthy young adults aged between 21 and 29 years. Two types of contour-based stereotest symbols, lines and squares, were developed. Distortions were classified into six distinct patterns, each further divided into eight grades of severity. Participants were tasked with identifying visual targets, and their stereothresholds were determined under different conditions of induced distortion. Stereopsis was measured within a range of 2.9 to 1.0 log arcsec, at 0.2 log arcsec intervals. Stereopsis changes under different distortion scenarios were analyzed using the generalized estimating equations, with a sequential Bonferroni adjustment applied for pairwise comparisons. Results: A direct and quantifiable correlation was observed between the severity of metamorphopsia and reductions in stereopsis. As the degree of visual distortion increased, notably in both frequency and amplitude, there was a corresponding decline in stereopsis. This relationship held true in both near and distance measurements of stereopsis. Statistical analyses further reinforced these findings, highlighting a significant detrimental effect of distortion components on stereoacuity. Conclusions: The findings highlight the clinical significance of understanding the interplay between unilateral metamorphopsia and stereopsis. Early interventions in conditions leading to metamorphopsia might be critical to maintaining optimal stereopsis.


Assuntos
Percepção de Profundidade , Visão Binocular , Adulto Jovem , Humanos , Adulto , Acuidade Visual , Transtornos da Visão/etiologia , Nível de Saúde
8.
Elife ; 132024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568729

RESUMO

Primates rely on two eyes to perceive depth, while maintaining stable vision when either one eye or both eyes are open. Although psychophysical and modeling studies have investigated how monocular signals are combined to form binocular vision, the underlying neuronal mechanisms, particularly in V1 where most neurons exhibit binocularity with varying eye preferences, remain poorly understood. Here, we used two-photon calcium imaging to compare the monocular and binocular responses of thousands of simultaneously recorded V1 superficial-layer neurons in three awake macaques. During monocular stimulation, neurons preferring the stimulated eye exhibited significantly stronger responses compared to those preferring both eyes. However, during binocular stimulation, the responses of neurons preferring either eye were suppressed on the average, while those preferring both eyes were enhanced, resulting in similar neuronal responses irrespective of their eye preferences, and an overall response level similar to that with monocular viewing. A neuronally realistic model of binocular combination, which incorporates ocular dominance-dependent divisive interocular inhibition and binocular summation, is proposed to account for these findings.


Assuntos
Dominância Ocular , Olho , Animais , Visão Binocular , Macaca , Neurônios
9.
BMC Ophthalmol ; 24(1): 169, 2024 Apr 15.
Artigo em Inglês | MEDLINE | ID: mdl-38622543

RESUMO

BACKGROUND: Convergence insufficiency is a common issue in the field of binocular vision. Various treatment options have been suggested for managing this condition, but their efficacy in individuals with presbyopia remains unclear. The objective of this study is to compare the effectiveness of home-based vision therapy and prism prescription, in presbyopic patients with convergence insufficiency. METHODS/DESIGN: It is a randomized, prospective, double-blind clinical trial, with total of 150 participants randomly assigned to the three groups. The Control Group will receive a new near glasses as a conventional prescription, along with aimless and random eye movement exercises that do not have any convergence or accommodation effects. The Home Vision Therapy Group will receive new near glasses with accommodative and convergence eye exercises. The Prism Group will receive a near prismatic glasses prescribed using the Sheard's criterion. All treatments will be administered for a period of 2 months, and measurements of the modified convergence insufficiency symptoms survey (CISS), near point convergence, near phoria, and positive fusional vergence will be taken at baseline, one month later, and at the end of the treatment. DISCUSSION: We aim to identify which component - either the prism prescription or the home vision therapy - is more effective in improving binocular abilities and reducing patients' symptom scores. TRIAL REGISTRATION: ClinicalTrials.gov NCT05311917 with last update on 04/22/2023.


Assuntos
Transtornos da Motilidade Ocular , Estrabismo , Humanos , Transtornos da Motilidade Ocular/terapia , Estudos Prospectivos , Estrabismo/terapia , Movimentos Oculares , Ortóptica/métodos , Visão Binocular , Acomodação Ocular , Convergência Ocular , Ensaios Clínicos Controlados Aleatórios como Assunto
10.
Optom Vis Sci ; 101(4): 195-203, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684062

RESUMO

SIGNIFICANCE: Spatio-Temporal Optical Phase technology utilizes film pairs containing optical elements applied to standard single-vision spectacle lenses. This technology provides a dynamic optical cue that may have efficacy in reducing the rate of myopia progression, but the visual performance of this technology is unknown. PURPOSE: This study aimed to assess the visual performance of film pairs containing optical elements (tests) and a film pair with no optical elements (control). METHODS: In this randomized, single-masked, bilateral wear study, 42 participants aged 18 to 40 years wore four test designs (E, F-1, G, and F-2) and the control. Subjective data (subjective ratings [1 to 10 scale]: clarity of vision [far-away, intermediate, near] and vision [at night, while walking, overall satisfaction], and willingness to purchase [yes/no response]) were collected after 3 days. Visual acuity (VA)-based measures (monocular high/low-contrast VA [6 m], contrast sensitivity [6 m], and binocular high-contrast VA [6 m and 40 cm]) were collected at dispensing. Visual acuity-based measures were also collected while wearing spectacles with no film. Analyses were performed using linear mixed models and the χ2 test. Significance was set at 5%. RESULTS: The control performed better than any test for all subjective ratings (mean differences, 1.6 to 3.1 units: p<0.001), willingness to purchase (p<0.001), and designs F-1 and F-2 for binocular high-contrast VA at 40 cm (p=0.001 and p=0.01, respectively). Clarity of vision was significantly worse with F-2 compared with F-1 and G (p<0.001 and p=0.02, respectively). There were no differences between tests for any other subjective rating (p>0.1), willingness to purchase (p=0.11), or any VA-based measure (p>0.08). There were no differences between control and spectacles with no film for any VA-based measure (p>0.08). CONCLUSIONS: All four test film pairs reduced visual performance compared with control to a degree comparable with other myopia management devices. There was no difference in visual performance between three of the four test film pairs.


Assuntos
Óculos , Acuidade Visual , Humanos , Adulto , Acuidade Visual/fisiologia , Adulto Jovem , Feminino , Masculino , Adolescente , Sensibilidades de Contraste/fisiologia , Miopia/fisiopatologia , Miopia/terapia , Método Simples-Cego , Visão Binocular/fisiologia , Desenho de Equipamento , Refração Ocular/fisiologia
11.
Jpn J Ophthalmol ; 68(3): 183-191, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38598144

RESUMO

PURPOSE: To assess the impact of glaucoma on perceiving three-dimensional (3D) shapes based on monocular depth cues. STUDY DESIGN: Clinical observational study. METHODS: Twenty glaucoma patients, subjected to binocular visual-field sensitivity (binocular-VFS) tests using a Humphrey Visual Field Analyzer, and 20 age-matched healthy volunteers, underwent two tasks: identifying the nearest vertex of a 3D shape using monocular shading (3D-SfS), texture (3D-SfT), or motion (3D-SfM) cues, and distinguishing elementary one-dimensional (1D) features of these cues. The association of the visual-field index (VFI) of binocular-VFS with 3D shape perception in glaucoma patients was also examined. RESULTS: Glaucoma patients demonstrated reduced accuracy in distinguishing 1D luminance brightness and a larger "error-in-depth" between the perceived and actual depths for 3D-SfM and 3D-SfS compared to healthy volunteers. Six glaucoma patients with a 100% VFI for binocular-VFS exhibited a similar error-in-depth to the other fourteen glaucoma patients; they had a larger error-in-depth for 3D-SfM compared to healthy volunteers. No correlation between the error-in-depth values and the VFI values of binocular-VFS was observed. CONCLUSIONS: The 3D shape perception in glaucoma patients varies based on the depth cue's characteristics. Impaired 1D discrimination and larger thresholds for 3D-SfM in glaucoma patients with a 100% VFI for binocular-VFS indicate more pronounced perceptual deficits of lower-level elementary features for 3D-SfS and higher-level visual processing of 3D shapes for 3D-SfM. The effects of the location and degree of binocular visual-field defects on 3D shape perception remain to be elucidated. Our research provides insights into the 3D shape extraction mechanism in glaucoma.


Assuntos
Sinais (Psicologia) , Percepção de Profundidade , Glaucoma , Visão Binocular , Visão Monocular , Campos Visuais , Humanos , Masculino , Feminino , Percepção de Profundidade/fisiologia , Visão Binocular/fisiologia , Campos Visuais/fisiologia , Pessoa de Meia-Idade , Idoso , Glaucoma/fisiopatologia , Glaucoma/diagnóstico , Visão Monocular/fisiologia , Testes de Campo Visual , Pressão Intraocular/fisiologia , Percepção de Forma/fisiologia , Adulto
12.
Turk J Ophthalmol ; 54(2): 63-68, 2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38644781

RESUMO

Objectives: To evaluate the clinical results of a new trifocal intraocular lens (IOL) with sinusoidal design by comparing with a traditional trifocal IOL. Materials and Methods: A total of 79 patients undergoing uneventful microincisional cataract surgery with bilateral implantation of one of two types of trifocal IOLs, the Acriva Trinova IOL (VSY) or Acrysof IQ PanOptix IOL (Alcon), were enrolled in this prospective study. Visual and refractive outcomes, contrast sensitivity (CS), and defocus curve were assessed at 3 months after surgery. Patient satisfaction and incidence of photic phenomena were also evaluated. Results: The number of patients/eyes were 48/96 in the Trinova group and 31/62 in the PanOptix group. There were no significant differences between the groups for monocular and binocular corrected/uncorrected distance or intermediate (at 60 cm) and near visual acuities (VA) postoperatively. The Trinova group had statistically significantly better intermediate VA at 80 cm than the PanOptix group (p<0.05). The CS results of both groups were within the normal limits. In the binocular defocus curve of both IOLs, we observed a peak of good VA at 0.0 diopters defocus and a useful wide range for intermediate distances. The incidence of photic phenomena in the Trinova group was lower at postoperative 1 month (p<0.05) but this difference disappeared at 3 months. A total of 47 patients (97.9%) in the Trinova group and 30 patients (96.7%) in the PanOptix group stated that they would recommend the same IOL. Conclusion: Both trifocal IOLs provide good visual quality outcomes and patient satisfaction.


Assuntos
Lentes Intraoculares Multifocais , Presbiopia , Desenho de Prótese , Refração Ocular , Acuidade Visual , Humanos , Estudos Prospectivos , Feminino , Masculino , Acuidade Visual/fisiologia , Idoso , Pessoa de Meia-Idade , Presbiopia/fisiopatologia , Presbiopia/cirurgia , Refração Ocular/fisiologia , Visão Binocular/fisiologia , Satisfação do Paciente , Sensibilidades de Contraste/fisiologia , Facoemulsificação , Seguimentos , Implante de Lente Intraocular/métodos , Lentes Intraoculares
13.
Transl Vis Sci Technol ; 13(4): 25, 2024 Apr 02.
Artigo em Inglês | MEDLINE | ID: mdl-38639931

RESUMO

Purpose: The purpose of this study was to determine and compare binocular summation (BiS) of conventional visual acuity (cVA) versus hyperacuity (hVA) for photopic and scotopic luminance conditions as a potential biomarker to assess the outcome of interventions on binocular function. Methods: Sixteen young adults (age range [years] = 21-31; 8 women; cVA logMAR < 0.0) participated in this study. The Freiburg Visual Acuity Test (FrACT) was used for VA testing and retested on another day. Both cVA and hVA were determined for dark grey optotypes on light grey background. Participants underwent 40 minutes of dark adaptation prior to scotopic VA testing. Binocular and monocular VA testing was performed. The eye with better VA over the 2 days of testing was selected, the BiS was quantified (binocular VA - better monocular VA) and repeated measures ANOVAs were performed. Results: Binocular VA exceeded monocular VA for all luminance conditions, VA-types, and sessions. We report BiS estimates for photopic and scotopic cVA and hVA, (logMAR BiS ± SEM [decimal BiS]): photopic = -0.01 ± 0.01 [1.03] and -0.06 ± 0.03 [1.15]; and scotopic = -0.05 ± 0.01 [1.12] and -0.11 ± 0.04 [1.28], respectively). Improvement for binocular vision estimates ranged from 0.01 to 0.11 logMAR. A repeated-measures ANOVA (RM ANOVA) did not reveal significant effects of LUMINANCE or VA TYPE on BiS, albeit a trend for strongest BiS for scotopic hVA (15% vs. 28%, photopic versus scotopic, respectively) and weakest for photopic cVA (3% vs. 12%, photopic versus scotopic conditions, respectively). Conclusions: Our results indicate that BiS of VA is relevant to scotopic and photopic hVA and cVA. It appears therefore a plausible candidate biomarker to assess the outcome of retinal therapies restoring rod or cone function on binocular vision. Translational Relevance: Binocular summation of visual acuity might serve as a clinical biomarker to monitor therapy outcome on binocular rod and cone-mediated vision.


Assuntos
Testes Visuais , Visão Binocular , Adulto Jovem , Humanos , Feminino , Adulto , Acuidade Visual , Testes Visuais/métodos , Visão Ocular , Biomarcadores
14.
Zhonghua Yan Ke Za Zhi ; 60(4): 312-315, 2024 Apr 11.
Artigo em Chinês | MEDLINE | ID: mdl-38583053

RESUMO

Infantile esotropia is a common ophthalmic disease in children. A lot of clinical and basic research evidence suggests that early surgery enhances sensory and ocular motor development. However, the proper timing of surgery has been debated for decades. In addition, there is more likely instability of deviation in the preoperative evaluation of infants, and even if the patient achieved alignment after surgery, the defects in binocular vision may accompany for a lifetime. This article analyzes the difficulties and key points of early intervention for infantile esotropia, aiming to provide scientific ideas for the early treatment of children with infantile esotropia in China.


Assuntos
Esotropia , Criança , Lactente , Humanos , Esotropia/cirurgia , Visão Ocular , Visão Binocular , China , Face , Músculos Oculomotores/cirurgia
15.
J Refract Surg ; 40(4): e270-e277, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38593255

RESUMO

PURPOSE: To investigate the effect of age on visual outcomes after the bilateral implantation of trifocal intraocular lenses (IOLs). METHODS: A total of 290 patients (580 eyes) who underwent bilateral implantation of a trifocal IOL were enrolled in this retrospective case-control study. Patients were divided into five age groups: 45 to 49, 50 to 54, 55 to 59, 60 to 64, and 65 years and older. Postoperative monocular uncorrected and corrected distance visual acuity (UDVA and CDVA, respectively), uncorrected near visual acuity (UNVA), binocular distance-corrected defocus curve, spectacle dependence for near and distance vision, and patient satisfaction scores were compared among the five groups. RESULTS: The 45 to 49 years group had significantly better mean UDVA (0.02 ± 0.05 logMAR) and UNVA (0.02 ± 0.04 logMAR) than the 65 years and older group (0.06 ± 0.09 and 0.09 ± 0.09 logMAR; P = .029 and P < .001; respectively). However, no significant differences were observed in the mean CDVA among the groups. Binocular visual performance of the 45 to 49 years group was better than that of the 65 years and older age group at defocuses of +1.00, +0.50, -1.00, and -3.00 D. No significant differences were observed in spectacle dependence for near and distance vision or in patient satisfaction scores among the five groups. CONCLUSIONS: Bilateral implantation of trifocal IOLs can provide excellent near and distance vision in both young and older patients. However, UDVA and UNVA revealed considerably worse results in the older group, although no significant difference was observed in CDVA and postoperative refractive errors by age. [J Refract Surg. 2024;40(4):e270-e277.].


Assuntos
Lentes Intraoculares , Facoemulsificação , Humanos , Idoso , Pessoa de Meia-Idade , Refração Ocular , Implante de Lente Intraocular , Óculos , Estudos Retrospectivos , Estudos de Casos e Controles , Visão Binocular , Satisfação do Paciente , Desenho de Prótese
16.
Vision Res ; 219: 108401, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38569223

RESUMO

Interocular grouping during binocular rivalry occurs when two images presented to each eye combine into a coherent pattern. The experience of interocular grouping is thought to be influenced by both eye-of-origin, which involves excitatory lateral connections among monocular neurons, and pattern coherence, which results from top-down intervention from higher visual areas. However, it remains unclear which factor plays a more significant role in the interocularly-grouped percepts during binocular rivalry. The current study employed an individual difference approach to investigate whether grouping dynamics are mainly determined by eye-of-origin or pattern coherence. We found that participants who perceived interocularly-driven coherent percepts for a longer duration also tended to experience longer periods of monocularly-driven coherent percepts. In contrast, participants who experienced non-coherent piecemeal percepts for an extended duration in conventional rivalry also had longer duration of non-coherent percepts in the interocular coherence setting. This individual differences in experiencing interocular grouping suggest that pattern coherence exerts a stronger influence on grouping dynamics during binocular rivalry compared to eye-of-origin factors.


Assuntos
Disparidade Visual , Visão Binocular , Humanos , Visão Binocular/fisiologia , Masculino , Feminino , Disparidade Visual/fisiologia , Adulto , Adulto Jovem , Individualidade , Estimulação Luminosa/métodos , Reconhecimento Visual de Modelos/fisiologia
17.
Cont Lens Anterior Eye ; 47(3): 102171, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38631934

RESUMO

PURPOSE: To determine the relationship between changes in accommodative and binocular function with myopia progression in myopic children over a two-year follow-up period, and to determine when changes in visual functions stabilized after switching from spectacles to orthokeratology (Ortho-K). METHODS: This prospective, self-controlled study followed thirty-six participants (aged 8-14 years) for two years after they switched from spectacles to Ortho-K. Accommodative and binocular function were assessed prior to and 1, 3, 6, 12, 18 and 24 months after commencing Ortho-K. Measurements included accommodative amplitude, accommodative response, accommodative facility, accommodative convergence/accommodation (AC/A), ocular alignment, positive relative accommodation (PRA), negative relative accommodation (NRA), horizontal vergence range, reading ability and stereoacuity. Myopia progression was quantified by the change in axial length. RESULTS: Ocular alignment, monocular and binocular accommodative facility, and PRA stabilized after 1 month. The distance blur point in the convergence range, the distance break and recovery point in the divergence range, accommodative amplitude, calculated AC/A, stereoacuity and reading ability stabilized within 6 months. After two years of Ortho-K, NRA significantly increased (p = 0.044), while it showed no significant difference after one-year of lens wear (p = 0.49). The distance break point in the convergence range showed no significant difference (p = 0.20), but significantly decreased after one-year (p = 0.005). There were no significant correlations between the change in axial length with changes in accommodative or binocular function (p > 0.05). CONCLUSION: Accommodative and binocular function changed significantly after switching from spectacles to Ortho-K and most of the parameters stabilized within the first 6 months. There was no association between the change in accommodative or binocular function and myopia progression.


Assuntos
Acomodação Ocular , Progressão da Doença , Óculos , Miopia , Procedimentos Ortoceratológicos , Visão Binocular , Humanos , Criança , Acomodação Ocular/fisiologia , Masculino , Feminino , Adolescente , Visão Binocular/fisiologia , Miopia/fisiopatologia , Miopia/terapia , Estudos Prospectivos , Acuidade Visual/fisiologia , Refração Ocular/fisiologia , Resultado do Tratamento
18.
BMC Ophthalmol ; 24(1): 170, 2024 Apr 16.
Artigo em Inglês | MEDLINE | ID: mdl-38627750

RESUMO

BACKGROUND: This study aimed to compare the results of the Chronos binocular/monocular refraction system, that measures objective and subjective ocular refraction in one unit, to objective findings obtained from a conventional autorefractometer and a conventional subjective ocular refraction using a trial-frame in real space. METHODS: Twenty-eight healthy volunteers (21.2 ± 1.5 years old) were included in this study. Objective ocular refraction was measured using two tests: the Chronos binocular/monocular refraction system under binocular conditions and a conventional autorefractometer under monocular conditions. Subjective ocular refraction was measured using three tests: Chronos binocular/monocular refraction system under binocular, monocular conditions, and trial-frame in the real space under monocular conditions. The measurement distance was set to 5.0 m for each test. All ocular refractions were converted into spherical equivalents (SEs). RESULTS: The objective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 4.08 ± 2.76 D) than with the conventional autorefractometer under monocular condition (- 3.85 ± 2.66 D) (P = 0.002). Although, the subjective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (- 3.55 ± 2.67 D) than with the trial-frame in the real space under monocular condition (- 3.33 ± 2.75 D) (P = 0.002), Chronos binocular/monocular refraction system under monocular condition (- 3.17 ± 2.57 D) was not significantly different from that in trial-frame in real space under monocular condition (P = 0.33). CONCLUSION: These findings suggest that the Chronos binocular/monocular refraction system, which can complete both objective and subjective ocular refraction tests in a single unit, is suitable for screening ocular refraction, although it produces slightly more myopic results. Furthermore, subjective ocular refraction testing accuracy in Chronos binocular/monocular refraction system can be equivalent to trial-frame in real-space testing by switching from binocular to monocular condition.


Assuntos
Refração Ocular , Visão Binocular , Humanos , Adulto Jovem , Adulto , Acuidade Visual , Testes Visuais , Olho
19.
Eye (Lond) ; 38(Suppl 1): 15-20, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38580742

RESUMO

PURPOSE: To evaluate the tolerance to refractive errors of a new purely refractive extended depth of focus (EDF) intraocular lens (IOL) using preclinical and clinical metrics. METHODS: Preclinical evaluation included computer simulations of visual acuity (sVA) and dysphotopsia profile of different IOL designs (refractive EDF, diffractive EDF, multifocal, standard, and enhanced monofocals) using an appropriate eye model with and without ±0.50 D defocus and/or +0.75 D of astigmatism. Patients bilaterally implanted with a refractive EDF (Model ZEN00V) or an enhanced monofocal (Model ICB00) IOL from a prospective, randomized study were included. At the 6-month postoperative visit, uncorrected and corrected distance vision (UDVA and CDVA), visual symptoms, satisfaction and dependency on glasses were evaluated in a subgroup of patients with absolute residual refractive error of >0.25 D in one or both eyes. RESULTS: In the presence of defocus and astigmatism, sVA was comparable for all except the multifocal IOL design. The refractive EDF was more tolerant to myopic outcomes and maintained a monofocal-like dysphotopsia profile with defocus. Binocular logMAR UDVA was -0.03 ± 0.08 for ZEN00V and -0.02 ± 0.11 for ICB00. 100% ZEN00V and 97% ICB00 patients did not need glasses and were satisfied with their distance vision. Monocular CDVA, contrast sensitivity and visual symptoms were also similar between both groups. CONCLUSIONS: The clinical outcomes of the refractive EDF IOL demonstrated high quality distance vision and dysphotopsia comparable to a monofocal IOL, even in the presence of refractive error, thus matching the design expectations of the EDF IOL.


Assuntos
Implante de Lente Intraocular , Lentes Intraoculares , Desenho de Prótese , Acuidade Visual , Humanos , Acuidade Visual/fisiologia , Estudos Prospectivos , Feminino , Masculino , Pessoa de Meia-Idade , Idoso , Percepção de Profundidade/fisiologia , Pseudofacia/fisiopatologia , Erros de Refração/fisiopatologia , Facoemulsificação , Satisfação do Paciente , Simulação por Computador , Refração Ocular/fisiologia , Astigmatismo/fisiopatologia , Visão Binocular/fisiologia
20.
Optom Vis Sci ; 101(4): 204-210, 2024 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-38684063

RESUMO

SIGNIFICANCE: A wearable optical apparatus that compensates for eye misalignment (strabismus) to correct for double vision (diplopia) is proposed. In contrast to prism lenses, commonly used to compensate for horizontal and/or vertical misalignment, the proposed approach is able to compensate for any combination of horizontal, vertical, and torsional misalignment. PURPOSE: If the action of the extraocular muscles is compromised (e.g., by nerve damage), a patient may lose their ability to maintain visual alignment, negatively affecting their binocular fusion and stereo depth perception capability. Torsional misalignment cannot be mitigated by standard Fresnel prism lenses. Surgical procedures intended to correct torsional misalignment may be unpredictable. A wearable device able to rectify visual alignment and restore stereo depth perception without surgical intervention could potentially be of great value to people with strabismus. METHODS: We propose a novel lightweight wearable optical device for visual alignment correction. The device comprises two mirrors and a Fresnel prism, arranged in such a way that together they rotationally shift the view seen by the affected eye horizontally, vertically, and torsionally. The extent of the alignment correction on each axis can be arbitrarily adjusted according to the patient's particular misalignment characteristics. RESULTS: The proposed approach was tested by computer simulation, and a prototype device was manufactured. The prototype device was tested by a strabismus patient exhibiting horizontal and torsional misalignment. In these tests, the device was found to function as intended, allowing the patient to enjoy binocular fusion and stereo depth perception while wearing the device for daily activities over a period of several months. CONCLUSIONS: The proposed device is effective in correcting arbitrary horizontal, vertical, and torsional misalignment of the eyes. The results of the initial testing performed are highly encouraging. Future study is warranted to formally assess the effectiveness of the device on multiple test patients.


Assuntos
Desenho de Equipamento , Músculos Oculomotores , Estrabismo , Visão Binocular , Dispositivos Eletrônicos Vestíveis , Humanos , Estrabismo/fisiopatologia , Estrabismo/cirurgia , Estrabismo/terapia , Visão Binocular/fisiologia , Músculos Oculomotores/fisiopatologia , Músculos Oculomotores/cirurgia , Percepção de Profundidade/fisiologia , Óculos , Movimentos Oculares/fisiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA