Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 215
Filtrar
1.
Leg Med (Tokyo) ; 22: 42-8, 2016 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27591538

RESUMO

This study was to compare the suitability and precision of xerographic and computer-assisted methods for bite mark investigations. Eleven subjects were asked to bite on their forearm and the bite marks were photographically recorded. Alginate impressions of the subjects' dentition were taken and their casts were made using dental stone. The overlays generated by xerographic method were obtained by photocopying the subjects' casts and the incisal edge outlines were then transferred on a transparent sheet. The bite mark images were imported into Adobe Photoshop® software and printed to life-size. The bite mark analyses using xerographically generated overlays were done by comparing an overlay to the corresponding printed bite mark images manually. In computer-assisted method, the subjects' casts were scanned into Adobe Photoshop®. The bite mark analyses using computer-assisted overlay generation were done by matching an overlay and the corresponding bite mark images digitally using Adobe Photoshop®. Another comparison method was superimposing the cast images with corresponding bite mark images employing the Adobe Photoshop® CS6 and GIF-Animator©. A score with a range of 0-3 was given during analysis to each precision-determining criterion and the score was increased with better matching. The Kruskal Wallis H test showed significant difference between the three sets of data (H=18.761, p<0.05). In conclusion, bite mark analysis using the computer-assisted animated-superimposition method was the most accurate, followed by the computer-assisted overlay generation and lastly the xerographic method. The superior precision contributed by digital method is discernible despite the human skin being a poor recording medium of bite marks.


Assuntos
Mordeduras Humanas , Odontologia Legal , Processamento de Imagem Assistida por Computador/métodos , Pele , Xerorradiografia/métodos , Dentição , Humanos , Radiografia Dentária
2.
Clin Exp Dermatol ; 34(1): 39-42, 2009 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-18627391

RESUMO

Calciphylaxis is a rare, life-threatening cause of skin necrosis. The condition is primarily reported in patients with end-stage renal disease, and is associated with significant morbidity and mortality. Treatment has mainly been empirical. We report a case of calciphylaxis in a patient with normal renal function and hypoparathyroidism, who responded to treatment with sodium thiosulfate. To our knowledge, this is the first reported case of the use of sodium thiosulfate to treat calciphylaxis in a patient with normal renal function.


Assuntos
Calciofilaxia/tratamento farmacológico , Quelantes/uso terapêutico , Rim/fisiologia , Tiossulfatos/uso terapêutico , Parede Abdominal , Adulto , Anticoagulantes/efeitos adversos , Calciofilaxia/diagnóstico por imagem , Calciofilaxia/patologia , Cálcio/efeitos adversos , Feminino , Humanos , Hipoparatireoidismo/complicações , Obesidade/complicações , Resultado do Tratamento , Varfarina/efeitos adversos , Xerorradiografia/métodos
3.
Zhongguo Yi Liao Qi Xie Za Zhi ; 25(6): 357-8, 351, 2001 Nov.
Artigo em Chinês | MEDLINE | ID: mdl-12583273

RESUMO

This paper introduces briefly xeroradiography, computed radiography system, x-ray dryview laser imaging series system and its products, digitized diagnostic technique, as well as the electronic radiography etc.


Assuntos
Diagnóstico por Computador/métodos , Xerorradiografia/métodos , Conversão Análogo-Digital , Humanos , Lasers , Selênio , Xerorradiografia/instrumentação
4.
Acta otorrinolaringol ; 8(1): 13-8, mayo 1996. tab
Artigo em Espanhol | LILACS | ID: lil-193577

RESUMO

La Estenosis Subglótica Adquirida es una entidad que afecta a tejidos blandos y estructuras cartilaginosas del espacio subglótico. Desde enero de 1987 hasta agosto de 1995, ingresaron al servicio de ORL del Hospital de Niños "J.M de Los Ríos" 80 pacientes con esta patología. El 87 por ciento (70) ameritaron traqueotomía y el 13 por ciento (10) no necesito tratamiento alguno. De los 70 pacientes traqueotomisados el 77 por ciento (60), se les realizó dilatación más infiltración de esteroides. al 10 por ciento (8), se les practicó laringotraqueoplastia, 2 pacientes fallecieron. El 75 por ciento (45) de los traqueotomisados fueron decanulados y dados de alta. El 25 por ciento (15) de los pacientes se mantienen en tratamiento. Fueron decanulados el 75 por ciento (6) de los 8 pacientes a los cuales se les realizó laringotraqueoplastia; y el 25 por ciento (2) no han podido ser decanulados por regresión de la estenosis.


Assuntos
Criança , Adolescente , Humanos , Masculino , Feminino , Laringoscopia/estatística & dados numéricos , Laringoestenose/cirurgia , Otolaringologia/métodos , Traqueostomia/estatística & dados numéricos , Xerorradiografia/métodos
5.
J Forensic Sci ; 40(2): 303-5, 1995 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7602296

RESUMO

The location of 19 fractures of 15 hyoid bones was studied from 13 cases of manual strangulation and two cases of hanging. The precise location of the fractures were determined by xeroradiography of isolated hyoid bones. To classify the location of the fractures, the greater cornu was divided into anterior, middle, and posterior thirds and the frequency of fracture occurrence in these locations was determined. In addition, the angle of curvature of the greater cornu was determined at the fracture site to ascertain if specific points along the greater cornu were more susceptible to fracture. Fractures were found with equal frequency in the posterior and middle thirds of the hyoid greater cornu (9/19, 47% for both posterior and middle) but were rare in the anterior portion (1/19, 5%). However, all fractures occurred between 30 degrees and 60 degrees of curvature of the hyoid and most fractures (approximately 60%) were found at approximately 50 degrees. These results indicate that fractures of the hyoid occur at vulnerable angles of curvature of the hyoid bone which, due to anatomic variation in hyoid shape, do not necessarily occur at specific segments of the hyoid bone. On this basis, although the presence of the hyoid fracture in strangulation is determined by the rigidity of the bone, the specific location is determined by the shape of the greater cornu.


Assuntos
Obstrução das Vias Respiratórias/diagnóstico por imagem , Medicina Legal/métodos , Fraturas Ósseas/diagnóstico por imagem , Osso Hioide/lesões , Violência , Xerorradiografia/métodos , Homicídio , Humanos
6.
Radiol Med ; 86(1-2): 116-26, 1993.
Artigo em Italiano | MEDLINE | ID: mdl-8346342

RESUMO

This paper reports on the cooperative work of the Department of Radiology of the Catholic University, Rome, and of the Italian Institute for Middle and Far East. The study was aimed at using xeroradiography and digital luminescence radiography for the archeometric evaluation of ancient ceramics and at assessing the imaging potentials of the two techniques. Some manufacturing techniques are reported which were used in the ancient world and societies for pottery making--i.e., coil building (the superimposition of clay rings), paddle and anvil beating and throwing of the wheel. Such techniques leave, on the vessel's wall, clear traces which can be detected by X-ray imaging. After discussing the main semiologic features, we present 4 case studies from the project archive. Each vase underwent xeroradiography and digital luminescence radiography. The former technique was useful in detailing minor phase transitions--e.g., pores and inclusions--while the latter, thanks to both its wide dynamic range and its image processing potentials, was optimal in defining very gradual thickness transitions due to the different techniques used to join the clay parts. By combining the two techniques, the manufacturing technology of the artifacts could be defined. The interactive processing of radiographic images at the system console was seen to be of major importance: it allowed the best results to be obtained thanks to the integration of the radiologists' and archeologists' know-how during the actual analytical stages.


Assuntos
Cerâmica , Intensificação de Imagem Radiográfica , Xerorradiografia , Arqueologia/métodos , Irã (Geográfico) , Medições Luminescentes , Intensificação de Imagem Radiográfica/instrumentação , Intensificação de Imagem Radiográfica/métodos , Tailândia , Xerorradiografia/instrumentação , Xerorradiografia/métodos
7.
Clin Mater ; 12(2): 83-7, 1993.
Artigo em Inglês | MEDLINE | ID: mdl-10148334

RESUMO

Th dynamics of the setting expansion of gypsum-bonded investment is complicated by many variables and not well understood. The purposes of this study were to examine the fluid mechanics of the flow of investment during setting and to determine if the presence of wax patterns influences effective setting expansion. Mesial-occlusal-distal (MOD) inlay wax patterns were invested at six different radial positions and four different axial positions in plastics casting rings. Total expansion was determined by using xeroradiography. Combined results of radial expansion data at different axial and radial locations within casting rings suggest that expansion of gypsum-bonded investment may represent a variant of the laminar flow of a viscous fluid.


Assuntos
Revestimento para Fundição Odontológica/química , Dentaduras , Moldagem de Cera para Incrustações/química , Colagem Dentária , Humanos , Teste de Materiais , Xerorradiografia/métodos
10.
Oral Surg Oral Med Oral Pathol ; 67(4): 443-8, 1989 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-2726205

RESUMO

The purpose of this study was to compare the quality of images obtained with dental xeroradiography to that obtained with conventional dental radiography during performance of root canal therapy on maxillary molars. For each step requiring radiographic information during endodontic treatment of 12 maxillary molars, a conventional radiograph and a xeroradiograph were made. This produced four pairs of images for each tooth treated as follows: (1) preoperative, (2) initial files for length determination, (3) master cones fitted, and (4) completed obturation of the root canal systems. The same x-ray machine was used as the source of radiation for all exposures with a setting of 70 kVp and 15 mA and with near identical projection for each pair of images achieved through use of a modified film holder and a custom positioning occlusal index made for each patient. Exposure time for the radiographs was 60 impulses (1 impulse = 1/60 second) and for the xeroradiographs it was 42 impulses. Images of structures and items important in endodontic diagnosis and treatment were rated as unacceptable (0), poor (1), adequate (2), or optimal (3) by four independent evaluators. Analysis of data showed the following: images of bone trabeculae, periodontal ligament spaces, root morphology, root apices, and fine bony abnormalities were judged to be significantly better in the radiographs than in the xeroradiographs (p less than 0.01) whereas there were no significant differences in image quality of pulp chamber morphology, root canal morphology, metallic measuring instruments, or endodontic filling materials.


Assuntos
Dente Molar/diagnóstico por imagem , Tratamento do Canal Radicular , Xerorradiografia , Adulto , Idoso , Processo Alveolar/diagnóstico por imagem , Feminino , Humanos , Masculino , Maxila , Pessoa de Meia-Idade , Ligamento Periodontal/diagnóstico por imagem , Pulpectomia , Intensificação de Imagem Radiográfica , Obturação do Canal Radicular , Raiz Dentária/diagnóstico por imagem , Xerorradiografia/instrumentação , Xerorradiografia/métodos
11.
Med Radiol (Mosk) ; 34(2): 28-34, 1989 Feb.
Artigo em Russo | MEDLINE | ID: mdl-2783991

RESUMO

A combined method of xeroradiographic scanning (ERS) was used for the recognition of tumors of different organs. Altogether 645 cancer patients were investigated: 98 with head and neck tumors, 102--with pulmonary and mediastinal tumors, 254--with liver tumors, 86--with renal tumors, 52--with bone tumors, and 53--with prostatic tumors. Special methods of investigation and tumoritropic radiopharmaceuticals 75Se-methionine, 67Ga-citrate, 85Sr, 113In, 99Tc, etc. were used. Statistical data processing was done using Olivetti computer M-24. ERS was shown to be the most effective method for the detection of cancer of the lung mediastinum (90%), head and neck (89%), and prostate (89%). The method is particularly valuable for tumors developing in anatomical regions inaccessible for examination, biopsy, and x-ray findings are not sufficiently clear. The use of ERS excludes possible errors in diagnosing disease on the edges of an organ, especially in liver and kidney investigation. The method also proved to be valuable for the assessment of therapeutic efficacy and correction of fields of irradiation.


Assuntos
Neoplasias/diagnóstico por imagem , Tomografia Computadorizada de Emissão/métodos , Xerorradiografia/métodos , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Fatores de Tempo , Tomografia Computadorizada de Emissão/instrumentação , Xerorradiografia/instrumentação
13.
Oral Surg Oral Med Oral Pathol ; 66(3): 359-64, 1988 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-3174071

RESUMO

Xeroradiographs and conventional radiographs were made of a dentulous human cadaver maxilla that was still covered with soft tissue. The times of exposure for the xeroradiographs started at 6 impulses (1 impulse = 1/60 second) and were increased by increments of 3 impulses through 48 for subsequent images, while the radiographs were made with D-speed film and exposure times of from 21 through 63 impulses, again at every third reading. The same x-ray machine, operated at 70 kVp and 15 mA, was used as the source of radiation for all images. Film/cassette-to-jaw relationship and focal-spot-to-film/cassette distance were standardized. Transmission optical density of the resulting images was determined. The results showed that radiographs with transmission optical densities comparable to those of xeroradiographs could be produced with exposure times approximately 3 times those used for xeroradiographs in the lower part of the range observed. This factor decreased to approximately 1.3 as optical density increased.


Assuntos
Radiografia Dentária/métodos , Xerorradiografia/métodos , Humanos , Maxila/diagnóstico por imagem , Intensificação de Imagem Radiográfica , Fatores de Tempo , Filme para Raios X
15.
Oral Surg Oral Med Oral Pathol ; 65(5): 618-25, 1988 May.
Artigo em Inglês | MEDLINE | ID: mdl-3163790

RESUMO

A method of superimposing a film on a xeroradiographic (XR) cassette for simultaneous intraoral exposure is evaluated for use as an imaging technique in clinical studies comparing Ektaspeed film and XR images. Sandwich images were indistinguishable from those produced by conventional technique. Pilot studies were conducted with 104 patients who had symptomatic dental problems. No significant differences were found in diagnostic usefulness or image quality between XR and film radiographs when sign test analysis was used. The sandwich technique yielded film and XR images with duplicate image geometry while reducing patient exposures to one half of that used in conventional image comparison protocols.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Radiografia Dentária/métodos , Filme para Raios X , Xerorradiografia/métodos , Estudos de Avaliação como Assunto , Humanos , Modelos Estruturais , Projetos Piloto , Doses de Radiação , Radiografia Dentária/instrumentação , Xerorradiografia/instrumentação
20.
Oral Surg Oral Med Oral Pathol ; 64(2): 241-8, 1987 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-3476902

RESUMO

The Xerox 110 dental system employs rigid beveled-edge cassettes containing charged selenium-alloy plates for intraoral xeroradiography. This study evaluates the ability of a skilled operator to position these cassettes accurately within the oral cavity as compared to the ability to position conventional film packets using two types of image holders. Results indicate that xeroradiographic cassettes are significantly more difficult to use for complete-mouth radiographs than comparable conventional film packets. Also, the use of xeroradiographic cassettes causes a slight increase in patient discomfort. In addition, two types of rectangular collimating devices were shown to be useful. The greatest shortcoming of the xeroradiographic cassette is not its greater thickness or rigidity but the reduced dimensions of its internal surface area.


Assuntos
Comportamento do Consumidor , Radiografia Dentária/métodos , Filme para Raios X , Xerorradiografia/métodos , Desenho de Equipamento , Humanos , Xerorradiografia/instrumentação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA