Your browser doesn't support javascript.
loading
Desempenho no treinamento auditivo computadorizado Performance in computerized auditory training / Computer-based auditory training: different type of performance analysis
Boaz, Ândrea de Melo; Biaggio, Eliara Pinto Vieira.
Afiliação
  • Boaz, Ândrea de Melo; Universidade Federal de Santa Maria. Programa de Pós-graduação em Distúrbios da Comunicação Humana. Santa Maria. BR
  • Biaggio, Eliara Pinto Vieira; Universidade Federal de Santa Maria. Programa de Pós-graduação em Distúrbios da Comunicação Humana. Santa Maria. BR
Audiol., Commun. res ; 24: e1942, 2019. tab
Artigo em Português | LILACS | ID: biblio-1011374
Biblioteca responsável: BR663.1
RESUMO
RESUMO Objetivo Analisar e correlacionar o desempenho auditivo na etapa de avaliação existente no software escolhido e respostas eletrofisiológicas pré e pós-treinamento auditivo computadorizado. Métodos Trata-se de um estudo longitudinal, comparativo, clínico e experimental, realizado após aprovação do comitê de ética. A amostra foi composta por sete crianças, com idade entre 7 anos e 8 anos e 11 meses, de ambos os gêneros, diagnosticadas com transtorno do processamento auditivo. A intervenção terapêutica foi baseada no treinamento com o software Escuta Ativa® e composta por 12 sessões, realizadas duas vezes por semana, com duração aproximada de 30 minutos cada. Analisou-se a pontuação nas etapas de avaliação existente no software escolhido e os achados da medida eletrofisiológica potencial evocado auditivo de longa latência, especificamente o componente P3, pré e pós-treinamento, por meio de estudo estatístico adequado. Resultados Dentre as três etapas de avaliação pelo software, não houve resultado estatisticamente significativo pós-treinamento. Quanto ao componente P3, 3 das 4 crianças com ausência do componente passaram a tê-lo, pós-intervenção terapêutica. Na busca de correlação entre resultados comportamentais e eletrofisiológicos, não houve significância estatística, em ambos os momentos de avaliação. Conclusão Não foi possível verificar diferença significativa entre os períodos pré e pós-treinamento, usando a etapa de avaliação do próprio software, mostrando necessidade de mais estudos de investigação para verificar a utilização desta ferramenta de avaliação em ambiente clínico. Percebeu-se efeito da plasticidade pós-treinamento, com o surgimento do componente P3 em algumas crianças. Não houve correlação entre as etapas de avaliação pelo software e a mensuração eletrofisiológica.
ABSTRACT
ABSTRACT Purpose Analyze and correlate the auditory performance in the evaluation stage in the chosen software and electrophysiological responses pre and post computer-based auditory training. Methods This is a longitudinal, comparative, clinical and experimental study, performed after the approval of the ethics committee. The sample consisted of seven children, aged 7 to 8 years and 11 months, from both genders, diagnosed with auditory processing disorder. The therapeutic intervention was based on the training with the Escuta Ativa® software and composed of 12 sessions, perforned twice a week, lasting approximately 30 minutes each. The score in the evaluation stage in the chosen software and the findings of the electrophysiological measurement on Long-Latency Potential Evoked Auditory, specifically P3 component, pre and post-training, were analyzed through an adequate statistical study. Results Among the three stages of the evaluation by the software, there was no statistically significant post-training result. As for the P3 component, 3 out of the 4 children started to have it post-intervention therapy. In the search for correlation between behavioral and electrophysiological results, there was no statistical significance in either moments of the evaluation. Conclusion It was not possible to verify a significant difference between the pre and post-training periods in the evaluation stage of the software itself, showing the need for further studies to verify the use of this evaluation tool in a clinical setting. An effect of post-training plasticity with the appearance of P3 component was noted in some children. There was no correlation between the evaluation steps by the software and the electrophysiological measurement.
Assuntos

Texto completo: Disponível Base de dados: LILACS Assunto: Percepção Auditiva / Transtornos da Percepção Auditiva / Potenciais Evocados P300 / Potenciais Evocados Auditivos Tipo de estudo: Estudo observacional Limite: Criança / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Audiol., Commun. res Ano de publicação: 2019 Tipo de documento: Artigo / Documento de projeto

Similares

MEDLINE

...
LILACS

LIS


Texto completo: Disponível Base de dados: LILACS Assunto: Percepção Auditiva / Transtornos da Percepção Auditiva / Potenciais Evocados P300 / Potenciais Evocados Auditivos Tipo de estudo: Estudo observacional Limite: Criança / Feminino / Humanos / Masculino País/Região como assunto: América do Sul / Brasil Idioma: Português Revista: Audiol., Commun. res Ano de publicação: 2019 Tipo de documento: Artigo / Documento de projeto