RESUMO
O objetivo deste estudo foi avaliar a influência da canaleta metálica e do tipo de bráquete estético, se convencional ou autoligado, na intensidade da força de atrito. Foram utilizados três tipos de bráquetes ortodônticos estéticos convencional sem canaleta metálica (Morelli®), convencional com canaleta metálica (Tecnident®) e autoligados sem canaleta metálica (Eurodonto®). Os bráquetes foram associados a fios de duas dimensões, 0.017'' x 0.025'' e 0.019''x 0.025'' (Morelli®), retangulares, originando seis diferentes grupos de acordo com o tipo de bráquete/fio (n=10). De acordo com os resultados, observou-se que o maior atrito foi gerado pelo bráquete autoligado sem canaleta metálica, seguido pelo convencional com canaleta metálica (p 0,05). Concluiu-se que os bráquetes estéticos convencionais sem canaleta metálica apresentaram a menor força de atrito. (AU)
ABSTRACT
The aim of this study was to evaluate the influence of the metal channel and the type of aesthetic bracket, whether conventional or self-ligating, the magnitude of the frictional force. Three types of aesthetic orthodontic brackets were used conventional without metal channel (Morelli®), conventional with metal channel (Tecnident®), and self-ligating without metal channel (Eurodonto®). The brackets were associated with two dimensions yarn, 0.017'' x 0.025'' and 0,019" x 0.025 (Morelli®), rectangular, producing six different groups according to the type of bracket/wire (n=10). According to the results, it was observed that the greater friction generated by self-ligating was bracket without metallic channel, followed by conventional channel with metallic (p 0.05). It was concluded that conventional aesthetic brackets without metal channel had the lowest friction force. (AU)
Assuntos
Palavras-chave
Buscar no Google
Base de dados: BBO Assunto principal: Ortodontia / Braquetes Ortodônticos / Atrito Dentário Idioma: Pt Ano de publicação: 2018 Tipo de documento: Article
Buscar no Google
Base de dados: BBO Assunto principal: Ortodontia / Braquetes Ortodônticos / Atrito Dentário Idioma: Pt Ano de publicação: 2018 Tipo de documento: Article