Shear bond strength of metallic brackets: influence of saliva contamination
Retamoso, Luciana Borges; Collares, Fabrício Mezzomo; Ferreira, Eduardo Silveira; Samuel, Susana Maria Werner.
Afiliação
  • Retamoso, Luciana Borges; s.af
  • Collares, Fabrício Mezzomo; Federal University of Rio Grande do Sul. Dental School. Dental Materials Laboratory. Porto Alegre. BR
  • Ferreira, Eduardo Silveira; Federal University of Rio Grande do Sul. Dental School. Discipline of Orthodontics. Porto Alegre. BR
  • Samuel, Susana Maria Werner; Federal University of Rio Grande do Sul. Dental School. Dental Materials Laboratory. Discipline of Dental Materials. Porto Alegre. BR
J. appl. oral sci ; 17(3): 190-194, May-June 2009. graf, tab
Article em En | LILACS | ID: lil-514031
Biblioteca responsável: BR1.1
ABSTRACT

OBJECTIVE:

To evaluate the influence of saliva contamination on shear bond strength and the bond failure pattern of 3 adhesive systems (Transbond XT, AdheSE and Xeno III) on orthodontic metallic brackets bonded to human enamel. MATERIAL AND

METHODS:

Seventy-two permanent human molars were cut longitudinally in a mesiodistal direction, producing seventy-two specimens randomly divided into six groups. Each system was tested under 2 different enamel conditions no contamination and contaminated with saliva. In T, A and X groups, the adhesive systems were applied to the enamel surface in accordance with manufacturer's instructions. In TS, AS and XS groups, saliva was applied to enamel surface followed by adhesive system application. The samples were stored in distilled water at 37ºC for 24 h, and then tested for shear bond strength in a universal testing machine (Emic, DL 2000) running at a crosshead speed of 1 mm/min. After bond failure, the enamel surfaces were observed under an optical microscope at 40x magnification.

RESULTS:

The control and contaminated groups showed no significant difference in shear bond strength for the same adhesive system. However, shear bond strength of T group (17.03±4.91) was significantly higher than that of AS (8.58±1.73) and XS (10.39±4.06) groups (p<0.05). Regarding the bond failure pattern, TS group had significantly higher scores of no adhesive remaining on the tooth in the bonding area than other groups considering the adhesive remnant index (ARI) used to evaluate the amount of adhesive left on the enamel.

CONCLUSIONS:

Saliva contamination showed little influence on the 24-h shear bond strength of orthodontic brackets.