Automated calculation of the centerline of the human colon on CT images.
Acad Radiol
; 6(6): 352-9, 1999 Jun.
Article
em En
| MEDLINE
| ID: mdl-10376066
ABSTRACT
RATIONALE AND OBJECTIVES:
This article presents an evaluation of an automated technique for determining the colon centerline with computed tomographic (CT) data sets. MATERIALS ANDMETHODS:
The technique proceeds as follows. After indication of a voxel in the rectum, voxels corresponding to air were segmented. Points along the colon centerline were estimated on the basis of centers of mass of grown voxels. A second segmentation and centerline calculation was initiated at the cecum. These two centerlines were then averaged. The resulting average was refined by using lumen data obtained perpendicular to the average centerline. The accuracy of the technique was investigated with simulation phantoms. The technique was also evaluated for 40 clinical colon cases. Calculated centerline points were compared with those indicated by radiologists for a randomly selected clinical case.RESULTS:
In the simulation studies, the calculated centerline points were, on average, within 2.5 mm of the true centerlines but differed by up to 4 mm in regions of deep folds or sharp turns. In the clinical colon study, 40% of the centerlines were computed with a single seed point and 25% with two seed points. Average centerlines were computed in 1 minute. The root mean square difference between the computed centerline points and those indicated by the radiologists was 4-5 mm (comparable to interobserver variations).CONCLUSION:
Accurate centerlines can be determined from colon CT data with this automated technique.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Processamento de Imagem Assistida por Computador
/
Tomografia Computadorizada por Raios X
/
Colo
Idioma:
En
Ano de publicação:
1999
Tipo de documento:
Article