Your browser doesn't support javascript.
loading
Posterior epidural space depth: safety of the loss of resistance and hanging drop techniques.
Hoffmann, V L; Vercauteren, M P; Vreugde, J P; Hans, G H; Coppejans, H C; Adriaensen, H A.
Afiliação
  • Hoffmann VL; Department of Anaesthesiology, University Hospital Antwerp, Edegem, Belgium.
Br J Anaesth ; 83(5): 807-9, 1999 Nov.
Article em En | MEDLINE | ID: mdl-10690148
ABSTRACT
We have compared skin to epidural space distance (SED) and tip to tip distance (TTD), a measure of posterior epidural space depth (PESD), in 40 patients with a 27-gauge Whitacre needle after identification of the epidural space using the hanging drop (HD) or loss of resistance (LOR) to air technique. After the LOR technique, TTD was found to be 2 mm greater than that after the HD technique, whereas SED was the same. We conclude that identification of the epidural space can be performed successfully with both techniques, but with a diminished risk of dural damage after LOR compared with the HD technique.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Espaço Epidural / Anestesia Epidural Idioma: En Ano de publicação: 1999 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Espaço Epidural / Anestesia Epidural Idioma: En Ano de publicação: 1999 Tipo de documento: Article