Comparison of effectiveness of an 8-mm versus a 4-mm tip electrode catheter for radiofrequency ablation of typical atrial flutter.
Kasai, A; Anselme, F; Teo, W S; Cribier, A; Saoudi, N.
Afiliação
  • Kasai A; Department of Cardiology, Rouen University Hospital, France.
Am J Cardiol ; 86(9): 1029-32, A10, 2000 Nov 01.
Article em En | MEDLINE | ID: mdl-11053723
ABSTRACT
An 8-mm catheter does not appear superior to 4-mm tip electrode for atrial flutter ablation. The potential advantage of allowing higher energy delivery on a larger surface is compensated by the lack of consistent contact with the endocardial surface.