Your browser doesn't support javascript.
loading
Analysis of regulatory phosphorylation sites in ZAP-70 by capillary high-performance liquid chromatography coupled to electrospray ionization or matrix-assisted laser desorption ionization time-of-flight mass spectrometry.
Miliotis, T; Ericsson, P O; Marko-Varga, G; Svensson, R; Nilsson, J; Laurell, T; Bischoff, R.
Afiliação
  • Miliotis T; Department of Analytical Chemistry, Lund University, Sweden.
J Chromatogr B Biomed Sci Appl ; 752(2): 323-34, 2001 Mar 10.
Article em En | MEDLINE | ID: mdl-11270871
A methodology for the rapid and quantitative analysis of phosphorylation sites in proteins is presented. The coupling of capillary high-performance liquid chromatography (HPLC) to electrospray ionization mass spectrometry (ESI-MS) allowed one to distinguish phosphorylation sites based on retention time and mass difference from complex peptide mixtures. The methodology was first evaluated and validated for a mixture of non-, mono-, and dityrosine-phosphorylated synthetic peptides, corresponding to the tryptic fragment 485-496 (ALGADDSYYTAR) of the human protein tyrosine kinase ZAP-70. The limits of detection for the non-, mono- and diphosphorylated peptides were about 15, 40 and 100 fmol, respectively, when using a 300 microm I.D. column. Application of the method was extended to identify phosphopeptides generated from a trypsin digest of recombinant autophosphorylated ZAP-70, in particular with respect to quantifying the status at the regulatory phosphorylation sites Tyr-492 and Tyr-493. Combination of chromatographic and on-line tandem mass spectrometry data allowed one to ascertain the identity of the detected peptides, a prerequisite to analyses in more complex biological samples. As an extension to the methodology described above, we evaluated the feasibility of interfacing capillary HPLC to matrix assisted laser desorption ionisation time-of-flight mass spectrometry (MALDI-TOF-MS), using a micromachined piezoelectric flow-through dispenser as the interface. This enabled direct arraying of chromatographically separated components onto a target plate that was precoated with matrix for subsequent analysis by MALDI-TOF-MS without further sample handling.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Proteínas Tirosina Quinases / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas por Ionização por Electrospray Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Proteínas Tirosina Quinases / Cromatografia Líquida de Alta Pressão / Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz / Espectrometria de Massas por Ionização por Electrospray Idioma: En Ano de publicação: 2001 Tipo de documento: Article