Your browser doesn't support javascript.
loading
LabHEART: an interactive computer model of rabbit ventricular myocyte ion channels and Ca transport.
Puglisi, J L; Bers, D M.
Afiliação
  • Puglisi JL; Department of Physiology and Biophysics, University of Illinois at Chicago, Stritch School of Medicine, Maywood, Illinois 60153, USA.
Am J Physiol Cell Physiol ; 281(6): C2049-60, 2001 Dec.
Article em En | MEDLINE | ID: mdl-11698264
ABSTRACT
An interactive computer program, LabHEART, was developed to simulate the action potential (AP), ionic currents, and Ca handling mechanisms in a rabbit ventricular myocyte. User-oriented, its design allows switching between voltage and current clamp and easy on-line manipulation of key parameters to change the original formulation. The model reproduces normal rabbit ventricular myocyte currents, Ca transients, and APs. We also changed parameters to simulate data from heart failure (HF) myocytes, including reduced transient outward (I(to)) and inward rectifying K currents (I(K1)), enhanced Na/Ca exchange expression, and reduced sarcoplasmic reticulum Ca-ATPase function, but unaltered Ca current density. These changes caused reduced Ca transient amplitude and increased AP duration (especially at lower frequency) as observed experimentally. The model shows that the increased Na/Ca exchange current (I(NaCa)) in HF lowers the intracellular [Ca] threshold for a triggered AP from 800 to 540 nM. Similarly, the decrease in I(K1) reduces the threshold to 600 nM. Changes in I(to) have no effect. Combining enhanced Na/Ca exchange with reduced I(K1) (as in HF) lowers the threshold to trigger an AP to 380 nM. These changes reproduce experimental results in HF, where the contributions of different factors are not readily distinguishable. We conclude that the triggered APs that contribute to nonreentrant ventricular tachycardia in HF are due approximately equally (and nearly additively) to alterations in I(NaCa) and I(K1). A free copy of this software can be obtained at http//www.meddean.luc.edu/lumen/DeptWebs/physio/bers.html.
Assuntos
Palavras-chave
Buscar no Google
Base de dados: MEDLINE Assunto principal: Simulação por Computador / Cálcio / Ventrículos do Coração / Canais Iônicos / Modelos Cardiovasculares / Miocárdio Idioma: En Ano de publicação: 2001 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Simulação por Computador / Cálcio / Ventrículos do Coração / Canais Iônicos / Modelos Cardiovasculares / Miocárdio Idioma: En Ano de publicação: 2001 Tipo de documento: Article