ABSTRACT

INTRODUCTION:

A direct or tubular communication between the systemic venous system and the systemic atrium, generally called fenestration, is surgically created to improve the postoperative period of patients undergoing total cavopulmonary connection. However, a fenestration prompts a potentially deleterious right to left shunt, and is generally closed after the postoperative period. Direct fenestrations can be closed using coils, or devices designed for atrial septal defect closure. However, no devices have been designed for closure of extracardiac fenestrations. We report our experience concerning the closure of extracardiac Fontan fenestration by the Amplatzer duct occluder (ADO).

METHODS:

From January 2001 to December 2002, we closed extracardiac Fontan fenestrations using the ADO device in 10 consecutive patients. Indications to fenestration closure were low velocity shunt through the fenestration, mild desaturation, and absence of effusions.

RESULTS:

All patients had a successful closure of the fenestration. The procedure was performed through the femoral vein in 7 cases and through the right jugular vein in 3. Mean central venous pressure increased not significantly from 12 to 13-mmHg. Mean oxygen saturation increased significantly from 90 to 97% (p<0.001). Immediate shut abolition was obtained in 9 cases. No complications were observed. At a median follow-up of 12 months (range 6-18 months), all patients are free of symptoms and have a normal oxygen saturation at rest as well as at exertion.

CONCLUSION:

The ADO device allowed closing the extracardiac Fontan fenestration in all patients with no mortality, no morbidity and a rate of 100% of complete closure at mid-term follow-up.