Your browser doesn't support javascript.
loading
Standardization of tritiated water by two improved methods.
Stanga, D; Moreau, I; Cassette, P.
Afiliação
  • Stanga D; National Institute of R&D for Physics and Nuclear Engineering Horia Hulubei IFIN-HH, P.O.Box MG-6, Bucharest-Magurele, R-077125, Romania. doru@ifin.nipne.ro
Appl Radiat Isot ; 64(10-11): 1203-6, 2006.
Article em En | MEDLINE | ID: mdl-16563779
ABSTRACT
Tritiated water has been standardized in the framework of a French-Romanian cooperation by two improved

methods:

liquid scintillation counting based on the triple to double coincidence ratio method and the internal gas proportional counting used in conjunction with a tritium generator for chemical reduction of water. The uncertainties of measurement for both methods were smaller than 0.6% and the two results were consistent within these uncertainties, indicating that either method is equally suited for standardizing tritiated water.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Contagem de Cintilação / Trítio / Água / Monitoramento de Radiação Idioma: En Ano de publicação: 2006 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Contagem de Cintilação / Trítio / Água / Monitoramento de Radiação Idioma: En Ano de publicação: 2006 Tipo de documento: Article