HPLC determination of a novel aroylhydrazone iron chelator (o-108) in rabbit plasma and its application to a pilot pharmacokinetic study.
Kovaríková, Petra; Klimes, Jirí; Sterba, Martin; Popelová, Olga; Gersl, Vladimír; Ponka, Premysl.
Afiliação
  • Kovaríková P; Department of Pharmaceutical Chemistry and Drug Control, Faculty of Pharmacy in Hradec Králové, Charles University in Prague, Heyrovského 1203, 500 05 Hradec Králové, Czech Republic. Petra.Kovarikova@faf.cuni.cz
Article em En | MEDLINE | ID: mdl-16725389
ABSTRACT
A high performance liquid chromatographic method for the determination of a biocompatible iron chelator, pyridoxal 2-chlorobenzoyl hydrazone (o-108), in rabbit plasma was developed and validated. The separation was achieved on a C18 column with the mobile phase composed of a mixture of 0.01 M phosphate buffer (pH 6) with the addition of EDTA (2 mM), methanol and acetonitrile (422414; v/v/v). The method was validated with respect to selectivity, linearity (0.8-150 microg/mL), intra- and inter-day variability and stability. This method was successfully applied to the analysis of the samples obtained from a pilot pharmacokinetic experiment, in which the chelator was administered intravenously to rabbits.