Biodosimetry using chromosome aberrations in human lymphocytes.
Radiat Prot Dosimetry
; 123(2): 241-5, 2007.
Article
em En
| MEDLINE
| ID: mdl-16954150
In vitro dose-response calibration curves for (60)Co gamma rays have been established for unstable chromosome aberrations in human peripheral blood lymphocytes. The observed dose-response data were fitted to a linear quadratic model. The calibration curve parameters were used to estimate the equivalent whole-body dose and dose to the irradiated region in partial body irradiation of cancer patients. The derived partial body doses and fractions of lymphocytes irradiated were in agreement with those estimated from the radiotherapy regimes.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Linfócitos
/
Monitoramento de Radiação
/
Aberrações Cromossômicas
/
Cromossomos Humanos
/
Neoplasias
Idioma:
En
Ano de publicação:
2007
Tipo de documento:
Article