Your browser doesn't support javascript.
loading
Effects of sequential changes from conventional ventilation to high-frequency oscillatory ventilation at increasing mean airway pressures in an ovine model of combined lung and head injury.
O'Rourke, J; Sheeran, P; Heaney, M; Talbot, R; Geraghty, M; Costello, J; McDonnell, C; Newell, J; Mannion, D.
Afiliação
  • O'Rourke J; Beaumont Hospital, Department of Anaesthesia and Intensive Care Medicine, Dublin, Ireland. jandeands@gmail.com
Eur J Anaesthesiol ; 24(5): 454-63, 2007 May.
Article em En | MEDLINE | ID: mdl-17261210
ABSTRACT

BACKGROUND:

The objective of this study was to determine the intracranial, cardiovascular and respiratory changes induced by conversion to high-frequency oscillator ventilation from conventional mechanical ventilation at increasing airway pressures.

METHODS:

In this study, 11 anaesthetized sheep had invasive cardiovascular and intracranial monitors placed. Lung injury was induced by saline lavage and head injury was induced by inflation of an intracranial balloon catheter. All animals were sequentially converted from conventional mechanical ventilation to high-frequency oscillator ventilation at target mean airway pressures of 16, 22, 28, 34 and 40 cm H(2)O. The mean airway pressure was achieved by adjusting positive end expiratory pressure while on conventional mechanical ventilation, and continuous distending pressures while on high-frequency oscillator ventilation. Cerebral lactate production, oxygen consumption and venous oximetry were measured and analysed in relation to changes in transcranial Doppler flow velocity. Transcranial Doppler profiles together with other physiological parameters were measured at each airway pressure.

RESULTS:

Cerebral perfusion pressure was significantly lower during high-frequency oscillator ventilation than during conventional mechanical ventilation (CMV 45, 34, 22, 6, 9 mmHg vs. HFOV 33, 20, 19, 5, 5 mmHg at airway pressures mentioned above, P = 0.02). Intracranial pressure and cerebrovascular resistance increased with increasing intrathoracic pressures (P = 0.001). Cerebral metabolic indices demonstrated an initial increase in anaerobic metabolism followed by a decrease in cerebral oxygen consumption progressing to cerebral infarction as intrathoracic pressures were further increased in a stepwise fashion. Arterial PaCO(2) increased significantly after converting from conventional mechanical ventilation to high-frequency oscillator ventilation (P = 0.001). However, no difference was observed between conventional mechanical ventilation and high-frequency oscillator ventilation when intracranial pressure, metabolic and transcranial Doppler indices were compared at equivalent mean airway pressures.

CONCLUSIONS:

The use of high positive end expiratory pressure with conventional mechanical ventilation or high continuous distending pressure with high-frequency oscillator ventilation increased intracranial pressure and adversely affected cerebral metabolic indices in this ovine model. Transcranial Doppler is a useful adjunct to intracranial pressure and intracranial venous saturation monitoring when major changes in ventilation strategy are adopted.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Ventilação de Alta Frequência / Traumatismos Craniocerebrais Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Respiração Artificial / Síndrome do Desconforto Respiratório / Ventilação de Alta Frequência / Traumatismos Craniocerebrais Idioma: En Ano de publicação: 2007 Tipo de documento: Article