Brazilian gutta-percha points. Part II: thermal properties.
Braz Oral Res
; 21(1): 29-34, 2007.
Article
em En
| MEDLINE
| ID: mdl-17384852
This study was undertaken to explore the effect of heating on gutta-percha, analyzing the occurrence of endothermic peaks corresponding to the transformation that occurs in the crystalline structure of the polymer during thermal manipulation. This study also sought to determine the temperature at which these peaks occur, causing a transformation from the beta- to the alpha-form, and from the alpha- to the amorphous phase. Eight nonstandardized gutta-percha points commercially available in Brazil (Konne, Tanari, Endopoint, Odous, Dentsply 0.04, Dentsply 0.06, Dentsply TP, Dentsply FM) and pure gutta-percha (control) were analysed using differential scanning calorimetry (DSC) and thermogravimetry analysis (TGA). The transition temperatures were determined and analysed. With the exception of Dentsply 0.04 and Dentsply 0.06, the majority of the products showed thermal behaviour typical of beta-gutta-percha, with two endothermic peaks, exhibiting two crystalline transformations upon heating from ambient temperature to 130 degrees. Upon cooling and reheating, few samples presented two endothermic peaks. It was concluded that heating dental gutta-percha to 130 degrees C causes changes to its chemical structure which permanently alter its physical properties.
Buscar no Google
Base de dados:
MEDLINE
Assunto principal:
Tratamento do Canal Radicular
/
Teste de Materiais
/
Guta-Percha
Idioma:
En
Ano de publicação:
2007
Tipo de documento:
Article