Your browser doesn't support javascript.
loading
The impact of continuous positive airway pressure on blood pressure in patients with obstructive sleep apnea syndrome: evidence from a meta-analysis of placebo-controlled randomized trials.
Haentjens, Patrick; Van Meerhaeghe, Alain; Moscariello, Antonio; De Weerdt, Sonia; Poppe, Kris; Dupont, Alain; Velkeniers, Brigitte.
Afiliação
  • Haentjens P; Center for Outcomes Research and Laboratory for Experimental Surgery, Endocrinology, Pharmacology, and General Internal Medicine, Universitair Ziekenhuis Brussel, Vrije Universiteit Brussel, Brussels, Belgium. patrick.haentjens@uzbrussel.be
Arch Intern Med ; 167(8): 757-64, 2007 Apr 23.
Article em En | MEDLINE | ID: mdl-17452537
BACKGROUND: Continuous positive airway pressure (CPAP) in patients with obstructive sleep apnea syndrome (OSAS) might lower blood pressure, but evidence from clinical studies is inconsistent, perhaps as a result of small sample size or heterogeneity in study design. This study aimed to assess whether CPAP reduces ambulatory blood pressure in patients with OSAS, to quantify the effect size with precision, and to identify trial characteristics associated with the greatest blood pressure reductions. METHODS: We identified randomized controlled trials of CPAP vs placebo in patients with OSAS specifically reporting 24-hour ambulatory mean blood pressure (MBP). RESULTS: We included a total of 572 patients from 12 randomized controlled trials. According to a random-effects model, the pooled estimate of the effect of the CPAP intervention was a net decrease of 1.69 mm Hg in 24-hour MBP (95% confidence interval, -2.69 to -0.69). Statistical heterogeneity was moderate (I(2) = 41%). Predefined metaregression analyses estimated that 24-hour MBP would decrease by 0.89 mm Hg per 10-point increase in apnea-hypopnea index at entry (P = .006), by 0.74 mm Hg for each increase of 10 arousal events per hour slept (P = .008), and by 1.39 mm Hg for each 1-hour increase in effective nightly use of the CPAP device (P = .01). CONCLUSIONS: Among patients with OSAS, CPAP reduces 24-hour ambulatory MBP, with greater treatment-related reductions in ambulatory MBP among patients with a more severe degree of OSAS and a better effective nightly use of the CPAP device. These reductions in blood pressure are likely to contribute to a better prognosis in terms of adverse cardiovascular events.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Síndromes da Apneia do Sono / Pressão Sanguínea / Pressão Positiva Contínua nas Vias Aéreas Idioma: En Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Síndromes da Apneia do Sono / Pressão Sanguínea / Pressão Positiva Contínua nas Vias Aéreas Idioma: En Ano de publicação: 2007 Tipo de documento: Article