Your browser doesn't support javascript.
loading
[Diagnostic value of 99mTc-N-NOET myocardial perfusion imaging during exercise for coronary artery disease].
Tian, Yue-qin; Zhang, Wan-chun; Dou, Ke-fei; Wang, Xue-bin; Tang, Zhi-gang; Hou, Qing; Zhang, Jun-bo; Zhang, Hai-long; Qiao, Shu-bin; He, Zuo-xiang.
Afiliação
  • Tian YQ; Department of Nuclear Medicine, Cardiovascular Institute and Fu Wai Hospital, Chinese Academy of Medical Science and Peking Union Medical College, Beijing 100037, China.
Zhonghua Xin Xue Guan Bing Za Zhi ; 35(3): 248-50, 2007 Mar.
Article em Zh | MEDLINE | ID: mdl-17582291
ABSTRACT

OBJECTIVE:

To assess the value of (99m)Tc-N-NOET ((99m)Tc-N-ethoxy-N-ethyl dithiocarbamato-nitrito) myocardial perfusion SPECT for the diagnosis of coronary artery disease.

METHODS:

A total of 42 patients [mean age (54 +/- 9) years, 35 men] with suspected chest pain were included in this study. 740 MBq of (99m)Tc-N-NOET was injected intravenously during bicycle exercise when the heart rate attained reached more than 85% of the expected maximum, or in cases of angina pectoris, severe arrhythmias and ischemic ST segment changes. (99m)Tc-N-NOET 740 MBq, SPECT myocardial imaging acquisitions were obtained at 15 minutes and 2 hours after (99m)Tc-N-NOET injection. Coronary angiography was performed in all patients.

RESULTS:

Coronary artery stenosis was detected in 26 patients and normal coronary angiography was shown in 16 patients. (99m)Tc-N-NOET myocardial perfusion imaging was abnormal in twenty-one patients out of the 26 patients with significant coronary artery stenosis (sensitivity, 81%); 14 out of 16 patients with normal angiography had a normal myocardial perfusion imaging (specificity, 88%). The positive predictive value, negative predictive value and predictive accuracy of (99m)Tc-N-NOET myocardial perfusion imaging for detection of CAD was 91%, 74% and 83%, respectively. The sensitivity of the imaging for detecting single vessel, double vessels and triple vessels disease were 60% (6/10), 86% (6/7) and 100% (9/9), respectively. There was mild (99m)Tc-N-NOET lung uptake in patients with coronary artery stenosis 15 minutes post (99m)Tc-N-NOET injection.

CONCLUSION:

SPECT myocardial perfusion imaging with (99m)Tc-N-NOET supplied an important diagnostic tool for detecting coronary artery disease. Lung uptake with stress (99m)Tc-N-NOET might be related to coronary artery disease.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Tiocarbamatos / Doença da Artéria Coronariana / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Teste de Esforço Idioma: Zh Ano de publicação: 2007 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Tiocarbamatos / Doença da Artéria Coronariana / Compostos de Organotecnécio / Tomografia Computadorizada de Emissão de Fóton Único / Teste de Esforço Idioma: Zh Ano de publicação: 2007 Tipo de documento: Article