Effect of the differential geometric form factor on differential absorption lidar measurements with topographical targets.
Bellecci, C; De Donato, F.
Afiliação
  • Bellecci C; Department of Physics, Istituto Nazionale di Fisica della Materia, Calabria University, 87036 Arcavacata di Rende, Cosenza 87036, Italy. bellecci@pobox.unical.it
Appl Opt ; 38(24): 5212-7, 1999 Aug 20.
Article em En | MEDLINE | ID: mdl-18324020
ABSTRACT
When the integrated differential absorption lidar (DIAL) technique is used to perform concentration measurements over long distances, the alignment between on and off laser beams becomes important. Here, through analysis of alignment error and of the corresponding differential geometric form factor, the effect of misalignment between off and on lines on performance of integrated concentration measurements by a coaxial DIAL system is considered.