Dichroic filters to protect milliwatt far-infrared detectors from megawatt ECRH radiation.
Bertschinger, G; Endres, C P; Lewen, F; Oosterbeek, J W.
Afiliação
  • Bertschinger G; Institut für Energieforschung-Plasmaphysik, Forschungszentrum Jülich, Association EURATOM-FZJ, Trilateral Euregio Cluster, 52425 Jülich, Germany. g.bertschinger@fz-juelich.de
Rev Sci Instrum ; 79(10): 10E709, 2008 Oct.
Article em En | MEDLINE | ID: mdl-19044527
ABSTRACT
Dichroic filters have been used to shield effectively the far infrared (FIR) detectors at the interferometer/polarimeter on TEXTOR. The filters consist of metal foils with regular holes, the hole diameter, the mutual spacing and the thickness of the foils are chosen to transmit radiation at the design frequency with transmission >90%. The attenuation at the low frequency end of the bandpass filter is about 30 dB per octave, the high frequency transmission is between 20% and 40%. The filters have been used to block the stray radiation from the megawatt microwave heating beam to the detectors of the FIR interferometer, operating with power on the detector in the milliwatt range. If required, the low frequency attenuation can be still enhanced, without compromising the transmission in the passband. The FIR interferometer used for plasma density and position control is no longer disturbed by electromagnetic waves used for plasma heating.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2008 Tipo de documento: Article