Dislocation of a double-lumen tunneled hemodialysis catheter causing dysfunction and bleeding.
Haid, B; Zitt, E; Meusburger, E; Wöss, E; Lhotta, K.
Afiliação
  • Haid B; Department of Nephrology and Dialysis, Academic Teaching Hospital Feldkirch, Feldkirch, Austria.
Blood Purif ; 27(2): 172-3, 2009.
Article em En | MEDLINE | ID: mdl-19141995
ABSTRACT
Dislocation of tunneled hemodialysis catheters is rare. This report describes displacement of a split catheter with the tip of the arterial limb outside and the venous limb inside the jugular vein. Use of the catheter with the limbs in inverse fashion caused severe hemorrhage along the catheter tunnel. To avoid this complication, a short subcutaneous catheter tunnel is recommended in adipose patients.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cateterismo Venoso Central / Cateteres de Demora / Diálise Renal / Hemorragia / Obesidade Idioma: En Ano de publicação: 2009 Tipo de documento: Article