Your browser doesn't support javascript.
loading
Three-dimensional coronary artery microscopy by intracoronary optical frequency domain imaging.
Tearney, Guillermo J; Waxman, Sergio; Shishkov, Milen; Vakoc, Benjamin J; Suter, Melissa J; Freilich, Mark I; Desjardins, Adrien E; Oh, Wang-Yul; Bartlett, Lisa A; Rosenberg, Mireille; Bouma, Brett E.
Afiliação
  • Tearney GJ; Wellman Center for Photomedicine, Massachusetts General Hospital, Department of Pathology, Harvard Medical School, Boston, Massachusetts 02114, USA. gtearney@partners.org
JACC Cardiovasc Imaging ; 1(6): 752-61, 2008 Nov.
Article em En | MEDLINE | ID: mdl-19356512
ABSTRACT

OBJECTIVES:

We present the first clinical experience with intracoronary optical frequency domain imaging (OFDI) in human patients.

BACKGROUND:

Intracoronary optical coherence tomography (OCT) is a catheter-based optical imaging modality that is capable of providing microscopic (approximately 7-microm axial resolution, approximately 30-microm transverse resolution), cross-sectional images of the coronary wall. Although the use of OCT has shown substantial promise for imaging coronary microstructure, blood attenuates the OCT signal, necessitating prolonged, proximal occlusion to screen long arterial segments. OFDI is a second-generation form of OCT that is capable of acquiring images at much higher frame rates. The increased speed of OFDI enables rapid, 3-dimensional imaging of long coronary segments after a brief, nonocclusive saline purge.

METHODS:

Volumetric OFDI images were obtained in 3 patients after intracoronary stent deployment. Imaging was performed in the left anterior descending and right coronary arteries with the use of a nonocclusive saline purge rates ranging from 3 to 4 ml/s and for purge durations of 3 to 4 s. After imaging, the OFDI datasets were segmented using previously documented criteria and volume rendered.

RESULTS:

Good visualization of the artery wall was obtained in all cases, with clear viewing lengths ranging from 3.0 to 7.0 cm at pullback rates ranging from 5 to 20 mm/s. A diverse range of microscopic features were identified in 2 and 3 dimensions, including thin-capped fibroatheromas, calcium, macrophages, cholesterol crystals, bare stent struts, and stents with neointimal hyperplasia. There were no complications of the OFDI procedure.

CONCLUSIONS:

Our results demonstrate that OFDI is a viable method for imaging the microstructure of long coronary segments in patients. Given its ability to provide microscopic information in a practical manner, this technology may be useful for studying human coronary pathophysiology in vivo and as a clinical tool for guiding the management of coronary artery disease.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Vasos Coronários / Imageamento Tridimensional / Tomografia de Coerência Óptica Idioma: En Ano de publicação: 2008 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Doença da Artéria Coronariana / Vasos Coronários / Imageamento Tridimensional / Tomografia de Coerência Óptica Idioma: En Ano de publicação: 2008 Tipo de documento: Article