Re-examining minimal luminal diameter relocation and quantitative coronary angiography--intravascular ultrasound correlations in stented saphenous vein grafts: methodological insights from the randomised RRISC trial.
Semeraro, Oscar; Agostoni, Pierfrancesco; Verheye, Stefan; Van Langenhove, Glenn; Van den Heuvel, Paul; Convens, Carl; Van den Branden, Frank; Bruining, Nico; Vermeersch, Paul.
Afiliação
  • Semeraro O; Antwerp Cardiovascular Institute Middelheim, Ziekenhuis Netwerk Antwerpen, Antwerp, Belgium.
EuroIntervention ; 4(5): 633-40, 2009 Mar.
Article em En | MEDLINE | ID: mdl-19378685
ABSTRACT

AIMS:

Angiographic parameters (such as late luminal loss) are common endpoints in drug-eluting stent trials, but their correlation with the neointimal process and their reliability in predicting restenosis are debated. METHODS AND

RESULTS:

Using quantitative coronary angiography (QCA) data (49 bare metal stent and 44 sirolimus-eluting stent lesions) and intravascular ultrasound (IVUS) data (39 bare metal stent and 34 sirolimus-eluting stent lesions) from the randomised Reduction of Restenosis In Saphenous vein grafts with Cypher stent (RRISC) trial, we analysed the "relocation phenomenon" of QCA-based in-stent minimal luminal diameter (MLD) between post-procedure and follow-up and we correlated QCA-based and IVUS-based restenotic parameters in stented saphenous vein grafts. We expected the presence of MLD relocation for low late loss values, as MLD can "migrate" along the stent if minimal re-narrowing occurs, while we anticipated follow-up MLD to be located close to post-procedural MLD position for higher late loss. QCA-based MLD relocation occurred frequently the site of MLD shifted from post-procedure to follow-up an "absolute" distance of 5.8 mm [2.5-10.2] and a "relative" value of 29% [10-46]. MLD relocation failed to correlate with in-stent late loss (rho = 0.14 for "absolute" MLD relocation [p = 0.17], and rho=0.03 for "relative" relocation [p = 0.811). Follow-up QCA-based and IVUS-based MLD values well correlated in the overall population (rho = 0.76, p < 0.001), but QCA underestimated MLD on average 0.55 +/- 0.49 mm, and this was mainly evident for lower MLD values. Conversely, the location of QCA-based MLD failed to correlate with the location of IVUS-based MLD (rho = 0.01 for "absolute" values--in mm [p = 0.911, rho = 0.19 for "relative" values--in % [p = 0.111). Overall, the ability of late loss to "predict" IVUS parameters of restenosis (maximum neointimal hyperplasia diameter, neointimal hyperplasia index and maximum neointimal hyperplasia area) was moderate (rho between 0.46 and 0.54 for the 3 IVUS parameters).

CONCLUSIONS:

These findings suggest the need for a critical re-evaluation of angiographic parameters (such as late loss) as endpoints for drug-eluting stent trials and the use of more precise techniques to describe accurately and properly the restenotic process.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Veia Safena / Grau de Desobstrução Vascular / Angioplastia Coronária com Balão / Stents / Ponte de Artéria Coronária / Angiografia Coronária / Ultrassonografia de Intervenção / Reestenose Coronária / Oclusão de Enxerto Vascular Idioma: En Ano de publicação: 2009 Tipo de documento: Article
Buscar no Google
Base de dados: MEDLINE Assunto principal: Veia Safena / Grau de Desobstrução Vascular / Angioplastia Coronária com Balão / Stents / Ponte de Artéria Coronária / Angiografia Coronária / Ultrassonografia de Intervenção / Reestenose Coronária / Oclusão de Enxerto Vascular Idioma: En Ano de publicação: 2009 Tipo de documento: Article