Real-time gas-correlation imaging employing thermal background radiation.
Opt Express ; 6(4): 92-103, 2000 Feb 14.
Article em En | MEDLINE | ID: mdl-19401749
ABSTRACT
Real-time imaging of gas leaks was demonstrated using an IR camera employing outdoor thermal background radiation. Ammonia, ethylene and methane detection was demonstrated in the spectral region 7-13 microm. Imaging was accomplished using an optical filter and a gas-correlation cell matching the absorption band of the gas. When two gases, such as ammonia and ethylene, are absorbing in the same wavelength region it is possible to isolate one for display by using gas-correlation multispectral imaging. Results from a field test on a leaking gas tanker are presented as QuickTime movies. A detection limit of 200 ppm x meter for ammonia was accomplished in this setup when the temperature difference between the background and the gas was 18 K and the frame rate was 15 Hz.
Buscar no Google
Base de dados: MEDLINE Idioma: En Ano de publicação: 2000 Tipo de documento: Article