Effect of 2-octyl-cyanoacrylate on ischemic anastomosis of the left colon.
Irkorucu, Oktay; Ucan, Bulent Hamdi; Cakmak, Guldeniz Karadeniz; Tascilar, Oge; Emre, Ali Ugur; Ofluoglu, Ebru; Bahadir, Burak; Karakaya, Kemal; Demirtas, Canan; Pasaoglu, Hatice; Ankarali, Handan; Comert, Mustafa.
Afiliação
  • Irkorucu O; Department of General Surgery, Zonguldak Karaelmas University, Medical School Zonguldak, Turkey. oktaytip@yahoo.com
J Invest Surg ; 22(3): 188-94, 2009.
Article em En | MEDLINE | ID: mdl-19466656
ABSTRACT

INTRODUCTION:

2-octyl-cyanoacrylate may be a good alternative in ischemic colon anastomosis without impairment of tissue perfusion.

METHODS:

Forty male Wistar albino rats were randomized into four experimental groups (n = 10 in each group). In group 1 (control), a well-perfused left colonic segment was transected, and free ends were anastomosed by propylene sutures. In groups 2, 3, and 4, the animals underwent a standardized surgical procedure to induce ischemic left colon anastomosis. In group 2, an end-to-end anastomosis was created using six interrupted 6-0 polypropylene sutures between ischemic edges. In group 3, after approximating the mesenteric and antimesenteric edges of the anastomosis with two 6-0 polypropylene sutures, 2-octyl-cyanoacrylate was applied between the edges. In group 4, anastomosis was created by the same technique as described in group 2, and additionally 2-octyl-cyanoacrylate was applied on suture line. Rats were killed on day 4 following operation. Anastomotic integrity, intraperitoneal adhesion scores, anastomotic bursting pressures, and tissue hydroxyproline levels were recorded. Histopathological examination of the anastomosis was also performed.

RESULTS:

There were no statistically significant differences among groups with respect to anastomotic integrity (p =.142). The mean bursting pressure values were 81.1 +/- 23.83, 43.3 +/- 26.06, 15.8 +/- 11.3, and 17.6 +/- 18.02 in groups 1, 2, 3, and 4, respectively. There were no statistically significant differences among groups 2, 3, and 4 with respect to tissue hydroxyproline levels and bursting pressure levels. The highest adhesion scores were observed in groups 3 and 4.

DISCUSSION:

2-octyl cyanoacrylate does not have additional advantages in the healing of experimental ischemic colon anastomosis.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Adesivos Teciduais / Colo / Cianoacrilatos / Isquemia Idioma: En Ano de publicação: 2009 Tipo de documento: Article