Your browser doesn't support javascript.
loading
Thyromental distance measurement--fingers don't rule.
Baker, P A; Depuydt, A; Thompson, J M D.
Afiliação
  • Baker PA; Department of Anaesthesia, Starship Children's Health, Auckland, New Zealand. paul@airwayskills.co.nz
Anaesthesia ; 64(8): 878-82, 2009 Aug.
Article em En | MEDLINE | ID: mdl-19604192
ABSTRACT
Thyromental distance (TMD) measurement is commonly used to predict difficult intubation. We surveyed anaesthetists to determine how this test was being performed. Comparative accuracy of ruler measurement and other forms of measurement were also assessed in a meta-analysis of published literature. Of respondents, 72% used fingers for TMD measurement and also considered three finger widths the minimum acceptable TMD. In terms of distance, the minimum acceptable TMD was felt to be 6.5 cm by 55% of respondents. However, the actual width of three fingers was (range) 4.6-7.0 cm (mean 5.9 cm), with significant differences between genders and between proximal and distal interphalangeal joints. The meta-analysis showed ruler measurement increased test sensitivity (48% (95% CI 43-53) vs 16% (95% CI 14-19) without a ruler), when predicting difficult intubation.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cartilagem Tireóidea / Queixo / Dedos / Intubação Intratraqueal Idioma: En Ano de publicação: 2009 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Cartilagem Tireóidea / Queixo / Dedos / Intubação Intratraqueal Idioma: En Ano de publicação: 2009 Tipo de documento: Article