Your browser doesn't support javascript.
loading
A pilot study to assess the feasibility of measurement of adrenal gland volume by magnetic resonance imaging.
Grant, Lee A; Napolitano, Antonella; Miller, Sam; Stephens, Kimberley; McHugh, Simon M; Dixon, Adrian K.
Afiliação
  • Grant LA; Department of Radiology, Cambridge University Teaching Hospitals NHS Foundation Trust, Cambridge, United Kingdom. leegrant100@gmail.com
Acta Radiol ; 51(1): 117-20, 2010 Feb.
Article em En | MEDLINE | ID: mdl-20088645
ABSTRACT

BACKGROUND:

Repeated computed tomography (CT) assessment of the adrenal glands is associated with a significant radiation burden. The increasing capabilities of magnetic resonance (MR) volumetric analysis of the adrenals make this a potentially alternative technique in man.

PURPOSE:

To determine whether MR imaging could be used to measure adrenal volume, and to determine the intra- and interobserver variation and repeatability of MR volume imaging of adrenals in healthy human subjects. MATERIAL AND

METHODS:

This was a single-cohort, sequential design, three-part study involving four MRI examinations per subject following ethical approval and informed consent. Information was collected on four healthy subjects (three male and one female). Two different investigators estimated the area of the adrenal gland for each of the 3-mm contiguous slices (and consequently adrenal volume). In order to estimate inter- and intrareader variability, a repeated-measures mixed model was fitted with adrenal volume as the dependent variable. In order to estimate any bias between readers, Bland-Altman methodology was applied.

RESULTS:

Intraobserver variation for adrenal gland volume is approximately 5% of a 3-cm(3 )adrenal gland. Interobserver variation is approximately 9% of a 3-cm(3) adrenal gland. Potential variation in measurement for adrenal volume from all sources equates to approximately 14% of a 3-cm(3) adrenal gland. Verification of image reading by a second investigator (consensus reading) reduces variability.

CONCLUSION:

Analysis of adrenal gland volume using MRI is a potentially reliable technique that could be used to assess a pathological change in adrenal size.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Glândulas Suprarrenais Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Imageamento por Ressonância Magnética / Glândulas Suprarrenais Idioma: En Ano de publicação: 2010 Tipo de documento: Article