Does combing the scalp reduce scalp electrode impedances?
J Neurosci Methods
; 188(2): 287-9, 2010 May 15.
Article
em En
| MEDLINE
| ID: mdl-20211649
ABSTRACT
Electrical activity from the human brain can be recorded via electrodes on the scalp. It is important to reduce the impedance of each electrode to minimize unwanted noise in the recording. Electrode impedance can be improved by abrading the skin to remove dead skin cells. In this experiment, we tested if abrading the skin by combing the scalp leads to a significant reduction in electrode impedance. We compared the mean electrode impedance values of 20 subjects whose scalps were combed prior to electrode cap placement, with 20 subjects whose scalps were not combed. Combing significantly reduced the impedances at central, right, and left areas of the scalp. This finding supports the use of scalp combing to reduce the time and subject discomfort that can be associated with placing scalp electrodes. This is particularly important for experiments testing children.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Couro Cabeludo
/
Artefatos
/
Impedância Elétrica
/
Eletroencefalografia
Idioma:
En
Ano de publicação:
2010
Tipo de documento:
Article