QEC values of the superallowed beta emitters 34Cl and 38Km.
Eronen, T; Elomaa, V-V; Hakala, J; Hardy, J C; Jokinen, A; Moore, I D; Reponen, M; Rissanen, J; Saastamoinen, A; Weber, C; Aystö, J.
Afiliação
  • Eronen T; Department of Physics, P.O. Box 35 (YFL), FI-40014, University of Jyväskylä, Finland. tommi.eronen@phys.jyu.fi
Phys Rev Lett ; 103(25): 252501, 2009 Dec 18.
Article em En | MEDLINE | ID: mdl-20366251
ABSTRACT
The superallowed beta-decay Q(EC) values of (34)Cl and (38)K(m) have been measured with an online Penning trap to be 5491.662(47) keV and 6044.223(41) keV, respectively. The new values are more precise than the previous high-precision reaction-based values but are consistent with them and establish that there are no significant systematic differences between the two types of measurements.