Your browser doesn't support javascript.
loading
Funnel-and-gate remediation systems augmented with passive filter wells.
Hudak, Paul F.
Afiliação
  • Hudak PF; Department of Geography and Environmental Science Program, University of North Texas, Denton, Texas 76203-5279, USA. hudak@unt.edu
Article em En | MEDLINE | ID: mdl-20694882
ABSTRACT
The objective of this study was to evaluate the ability of funnel-and-gate structures augmented with passive wells containing filter cartridges to capture contaminated groundwater in hypothetical, homogeneous and heterogeneous, unconfined aquifers. Perpendicular to groundwater flow, linear structures were 15 m wide, 1 m thick, and keyed into the base of the aquifer. Gates occupied 4 m of the total width of each simulated structure; one gate was 5 m from a contaminant plume's leading tip, while others occupied cross-gradient margins of the plume. Results suggest a modest reduction in remediation timeframes, up to 425 d per well added in these simulations; however, incremental benefits are highly variable and case specific.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluição da Água / Purificação da Água / Recuperação e Remediação Ambiental Idioma: En Ano de publicação: 2010 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluição da Água / Purificação da Água / Recuperação e Remediação Ambiental Idioma: En Ano de publicação: 2010 Tipo de documento: Article