Your browser doesn't support javascript.
loading
Short wavelength fundus autofluorescence versus near-infrared fundus autofluorescence, with microperimetric correspondence, in patients with geographic atrophy due to age-related macular degeneration.
Pilotto, Elisabetta; Vujosevic, Stela; Melis, Riccardo; Convento, Enrica; Sportiello, Patrik; Alemany-Rubio, Ernesto; Segalina, Sara; Midena, Edoardo.
Afiliação
  • Pilotto E; Department of Ophthalmology, University of Padua, via Giustiniani 2, Padua 35128, Italy. elisabetta.pilotto@unipd.it
Br J Ophthalmol ; 95(8): 1140-4, 2011 Aug.
Article em En | MEDLINE | ID: mdl-20974627
ABSTRACT

AIM:

To compare standard short-wavelength fundus autofluorescence (SW-FAF) and near infrared-wavelength fundus autofluorescence (NIR-FAF) in detecting geographic atrophy (GA) secondary to age-related macular degeneration, and its retinal sensitivity impairment.

METHODS:

Twenty-five consecutive patients (36 eyes) affected by GA were studied by means of fundus autofluorescence imaging, using both SW-FAF (excitation 488 nm, emission >500 nm) and NIR-FAF (excitation 787 nm, emission >800 nm). All patients underwent microperimetry to assess fixation characteristics and retinal sensitivity.

RESULTS:

In the extrafoveal region, the total hypoautofluorescent (hypo-FAF) area was significantly wider with NIR-FAF than with SW-FAF (8.03±6.68 mm(2) vs 7.37±6.34 mm(2) respectively; p=0.005). In the foveal area, the total hypo-FAF area was smaller with NIR-FAF than with SW-FAF (0.19±0.03 mm(2) versus 0.42±0.12 mm(2) respectively; p=0.008). Foveal sparing was larger at NIR-FAF compared with SW-FAF (p=0.021). In nine cases (25%) the site of fixation was hypoautofluorescent on SW-FAF, but normal on NIR-FAF with preserved retinal sensitivity.

CONCLUSIONS:

Standard SW-FAF may overestimate GA in the foveal area, correctly detected by NIR-FAF. In the extrafoveal area, SW-FAF may underestimate GA. Standard SW-FAF should be integrated with NIR FAF when detecting and following GA to avoid inconsistent results and misinterpretation, from both a morphological and functional perspective. Microperimetry helps to quantify retinal sensitivity in GA.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Atrofia Geográfica / Testes de Campo Visual / Degeneração Macular Idioma: En Ano de publicação: 2011 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Oftalmoscopia / Atrofia Geográfica / Testes de Campo Visual / Degeneração Macular Idioma: En Ano de publicação: 2011 Tipo de documento: Article