Your browser doesn't support javascript.
loading
Redoing a bioprosthetic tricuspid valve replacement with pacemaker wire through the ruined bioprosthetic valve orifice.
Guo, Hong-wei; Pan, Shi-wei; Song, Yun-hu; Hu, Sheng-shou.
Afiliação
  • Guo HW; Department of Surgery, Fuwai Hospital, Chinese Academy of Medical Sciences and Peking Union Medical college, Beijing 100037, China.
Chin Med J (Engl) ; 124(6): 958-60, 2011 Mar.
Article em En | MEDLINE | ID: mdl-21518613
Severe tricuspid regurgitation with permanent pacemaker wire passing through the orifice of bioprosthetic tricuspid valve is extremely rare. We present a case of such kind of patient and redid bioprosthetic tricuspid valve replacement. A hawk mouth forceps for bone surgery was used to cut off the mental ring of ruined bioprosthetic tricuspid valve and the ruined valve was removed. A new bioprosthetic tricuspid valve was implanted and the wire of permanent pacemaker was left outside the ring of bioprosthetic tricuspid valve. This method may be helpful for such kind of patient.
Assuntos
Buscar no Google
Base de dados: MEDLINE Assunto principal: Marca-Passo Artificial / Valva Tricúspide Idioma: En Ano de publicação: 2011 Tipo de documento: Article
Buscar no Google