Comparison of efficacy between continuous hemodiafiltration with a PMMA high-performance membrane dialyzer and a PAN membrane hemofilter in the treatment of septic shock patients with acute renal failure.
Contrib Nephrol
; 173: 182-190, 2011.
Article
em En
| MEDLINE
| ID: mdl-21865791
The aim of this study was to investigate whether continuous hemodiafiltration (CHDF) with a high-performance membrane dialyzer made of polymethylmethacrylate (PMMA-CHDF) in the treatment of septic shock patients with acute renal failure (ARF) is clinically relevant. 30 patients were treated with PMMA-CHDF. 13 patients treated with CHDF used a hemofilter made of polyacrylonitrile membrane (PAN-CHDF). Systolic blood pressure significantly increased in the PMMA-CHDF group following 24 h of treatment (p < 0.01), whereas it did not improve in the PAN-CHDF group. Urine volume significantly increased in the PMMA-CHDF group following 24 h of treatment which was more than in the PAN-CHDF group (p < 0.05). 28-day survival was 83.3% in the PMMA-CHDF group and 30.8% in the PAN-CHDF group, respectively (p < 0.01). We can assume that PMMA-CHDF in the treatment of septic shock patients with ARF is clinically relevant.
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Choque Séptico
/
Resinas Acrílicas
/
Hemofiltração
/
Hemodiafiltração
/
Polimetil Metacrilato
/
Injúria Renal Aguda
/
Membranas Artificiais
Idioma:
En
Ano de publicação:
2011
Tipo de documento:
Article