Your browser doesn't support javascript.
loading
Positive predictive value of the Xpert MRSA assay diagnostic for universal patient screening at hospital admission: influence of the local ecology.
Roisin, S; Laurent, C; Nonhoff, C; Deplano, A; Hallin, M; Byl, B; Struelens, M J; Denis, O.
Afiliação
  • Roisin S; Department of Clinical Microbiology and National MRSA Reference Laboratory, Erasme Hospital, Université Libre de Bruxelles, Brussels, Belgium. sandrine.roisin@erasme.ulb.ac.be
Eur J Clin Microbiol Infect Dis ; 31(5): 873-80, 2012 May.
Article em En | MEDLINE | ID: mdl-21874398
The purpose of this study was to assess the accuracy of the Xpert MRSA assay (XP) for the detection of methicillin-resistant Staphylococcus aureus (MRSA) carriage upon hospital admission. Nasal swabs were prospectively collected for MRSA screening from 1,891 patients admitted to a teaching hospital. XP results were compared to chromogenic agar culture results. MRSA was cultured in 61 specimens (3%). Compared with culture, XP had a sensitivity, specificity, positive, and negative predictive value of 60.7, 97.3, 37.8, and 98.9%, respectively. The median turnaround time (TAT) for the results was 3 h. Of 24 MRSA isolated from XP-negative samples, three harbored composite SCCmec. Among 61 samples with culture-negative but XP-positive results, 15 methicillin-susceptible S. aureus (MSSA) isolates tested positive by XP on pure colony lysates. These MSSA included: (i) strains with SCCmec deletion encompassing mecA and (ii) multilocus sequence typing (MLST) clonal complex (CC) 1 strains harboring a chromosomal sequence homologous to one of the orfX-SCCmec junction sequences targeted by XP. On account of the low sensitivity and positive predictive value in a hospital patient population with moderate prevalence of MRSA, culture still appears to be necessary in order to confirm polymerase chain reaction (PCR) results. The emergence of new SCCmec variants and the presence of MSSA harboring cross-reactive SCCmec-like elements may challenge the successful implementation of such detection systems.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Portador Sadio / Programas de Rastreamento / Técnicas Bacteriológicas / Técnicas de Diagnóstico Molecular / Testes Diagnósticos de Rotina / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2012 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Infecções Estafilocócicas / Portador Sadio / Programas de Rastreamento / Técnicas Bacteriológicas / Técnicas de Diagnóstico Molecular / Testes Diagnósticos de Rotina / Staphylococcus aureus Resistente à Meticilina Idioma: En Ano de publicação: 2012 Tipo de documento: Article